AOAndreia Sofia Oliveira

Andreia Sofia Oliveira

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Andreia Sofia Oliveira has a total of 59 co-authors. Here are the top co-authors by number of shared publications:

  • Ana Paula Serro

    Centro de Química Estrutural (CQE), Chemical Engineering Department and Institute of Molecular Sciences, Instituto Superior Técnico, University of Lisbon, Av. Rovisco Pais 1, 1049-001 Lisbon, Portugal; Egas Moniz Centre for Interdisciplinary Research (CiiEM), Egas Moniz School of Health & Science, Campus Universitário, Quinta da Granja, 2829-511 Monte de Caparica, Almada, Portugal

    10 shared publications
  • Rogerio Colaco

    Instituto Superior Técnico, University of Lisbon, Av. Rovisco Pais, 1049-001 Lisboa, Portugal

    7 shared publications
  • Ana Catarina Branco

    CQE, Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal; CDP2T, Escola Superior de Tecnologia de Setúbal, Instituto Politécnico de Setúbal, Setúbal, Portugal

    3 shared publications
  • Ana Clara Marques

    Universidade de Lisboa

    3 shared publications
  • Ana Topete

    Centro de Química Estrutural, Instituto Superior Técnico, Universidade de Lisboa, Portugal; CIIEM, Centro de Investigação Interdisciplinar Egas Moniz, Instituto Universitário Egas Moniz, Caparica, Portugal

    3 shared publications
  • Célio Gabriel Figueiredo-Pina

    Escola Superior de Tecnologia de Setúbal Instituto Politécnico de Setúbal Setúbal Portugal

    3 shared publications

Latest Publications

  • Open Access

    Tribomechanical Properties of PVA/Nomex® Composite Hydrogels for Articular Cartilage Repair

    by Francisco Santos, Carolina Marto-Costa, Ana Catarina Branco, Andreia Sofia Oliveira, Rui Galhano dos Santos, Madalena Salema-Oom, Roberto Leonardo Diaz, Sophie Williams, Rogério Colaço, Célio Figueiredo-Pina, et al.

    Due to the increasing prevalence of articular cartilage diseases and limitations faced by current therapeutic methodologies, there is an unmet need for new materials to replace damaged cartilage. In this work, poly(vinyl alcohol) (PVA) hydrogels were reinforced with different amounts of Nomex® (known for its high mechanical toughness, flexibility, and resilience) and sterilized by gamma irradiation. Samples were studied concerning morphology, chemical structure, thermal behavior, water content, wettability, mechanical properties, and rheological and tribological behavior. Overall, it was found that the incorporation of aramid nanostructures improved the hydrogel’s mechanical performance, likely due to the reinforcement’s intrinsic strength and hydrogen bonding to PVA chains. Additionally, the sterilization of the materials also led to superior mechanical properties, possibly related to the increased crosslinking density through the hydrogen bonding caused by the irradiation. The water content, wettability, and tribological performance of PVA hydrogels were not compromised by either the reinforcement or the sterilization process. The best-performing composite, containing 1.5% wt. of Nomex®, did not induce cytotoxicity in human chondrocytes. Plugs of this hydrogel were inserted in porcine femoral heads and tested in an anatomical hip simulator. No significant changes were observed in the hydrogel or cartilage, demonstrating the material’s potential to be used in cartilage replacement.


  • Open Access

    Super‐Strong Hydrogel Composites Reinforced with PBO Nanofibers for Cartilage Replacement

    by Andreia S. Oliveira, João C. Silva, Mónica V. Loureiro, Ana C. Marques, Nicholas A. Kotov, Rogério Colaço, Ana P. Serro

    Cartilage replacement materials exhibiting a set of demanding properties such as high water content, high mechanical stiffness, low friction, and excellent biocompatibility are quite difficult to achieve. Here, poly(p‐phenylene‐2,6‐benzobisoxazole) (PBO) nanofibers are combined with polyvinyl alcohol (PVA) to form a super‐strong structure with a performance that surpasses the vast majority of previously existing hydrogels. PVA–PBO composites with water contents in the 59–76% range exhibit tensile and compressive moduli reaching 20.3 and 4.5 MPa, respectively, and a coefficient of friction below 0.08. Further, they are biocompatible and support the viability of chondrocytes for 1 week, with significant improvements in cell adhesion, proliferation, and differentiation compared to PVA. The new composites can be safely sterilized by steam heat or gamma radiation without compromising their integrity and overall performance. In addition, they show potential to be used as local delivery platforms for anti‐inflammatory drugs. These attractive features make PVA–PBO composites highly competitive engineered materials with remarkable potential for use in the design of load‐bearing tissues. Complementary work has also revealed that these composites will be interesting alternatives in other industrial fields where high thermal and mechanical resistance are essential requirements, or which can take advantage of the pH responsiveness functionality.


  • Open Access

    Effects of Non-Conventional Sterilisation Methods on PBO-Reinforced PVA Hydrogels for Cartilage Replacement

    by Tomás Pires, Andreia Sofia Oliveira, Ana Clara Marques, Madalena Salema-Oom, Célio G. Figueiredo-Pina, Diana Silva, Ana Paula Serro

    Articular cartilage (AC) degradation is a recurrent pathology that affects millions of people worldwide. Polyvinyl alcohol (PVA) hydrogels have been widely explored for AC replacement. However, their mechanical performance is generally inadequate, and these materials need to be reinforced. Moreover, to be used in a clinical setting, such materials must undergo effective sterilisation. In this work, a PVA hydrogel reinforced with poly(p-phenylene-2,6-benzobisoxazole) (PBO) nanofibres was submitted to three non-conventional sterilisation methods: microwave (MW), high hydrostatic pressure (HHP), and plasma (PM), in order to evaluate their impact on the properties of the material. Sterilisation was achieved in all cases. Properties such as water content and hydrophilicity were not affected. FTIR analysis indicated some changes in crystallinity and/or crosslinking in all cases. MW was revealed to be the most suitable method, since, unlike to PM and HHP, it led to a general improvement of the materials’ properties: increasing the hardness, stiffness (both in tensile and compression), and shear modulus, and also leading to a decrease in the coefficient of friction against porcine cartilage. Furthermore, the samples remained non-irritant and non-cytotoxic. Moreover, this method allows terminal sterilisation in a short time (3 min) and using accessible equipment.


  • High-performance bilayer composites for the replacement of osteochondral defects

    by A. S. Oliveira, J. C. Silva, L. Figueiredo, F. C. Ferreira, N. A. Kotov, R. Colaço, A. P. Serro

    Two novel bilayer constructs for the repair of osteochondral defects were developed from nanofibers and ceramic particles embedded into PVA matrices, exhibiting multiple promising properties similar to those of corresponding natural tissues.


  • Development of polycarbonate urethane‐based materials with controlled diclofenac release for cartilage replacement

    by Andreia S. Oliveira, Inês Ferreira, Ana C. Branco, João C. Silva, Carolina Costa, Pedro Nolasco, Ana C. Marques, Diana Silva, Rogério Colaço, Célio G. Figueiredo‐Pina, et al.

    Hydrogels are very promising human cartilage replacement materials since they are able to mimic its structure and properties. Besides, they can be used as platforms for drug delivery to reduce inflammatory postsurgical reactions. Polycarbonate urethane (PCU) has been used in orthopedic applications due to its long‐term biocompatibility and bio‐durability. In this work, PCU‐based hydrogels with the ability to release an anti‐inflammatory (diclofenac) were developed, for the first time, for such purpose. The materials were reinforced with different amounts of cellulose acetate (CA, 10%, 15%, and 25% w/w) or carbon nanotubes (CNT, 1% and 2% w/w) in order to improve their mechanical properties. Samples were characterized in terms of compressive and tensile mechanical behavior. It was found that 15% CA and 2% CNT reinforcement led to the best mechanical properties. Thus, these materials were further characterized in terms of morphology, wettability, and friction coefficient (CoF). Contrarily to CNTs, the addition of CA significantly increased the material's porosity. Both materials became more hydrophilic, and the CoF slightly increased for PCU + 15%CA. The materials were loaded by soaking with diclofenac, and drug release experiments were conducted. PCU, PCU + 15%CA and PCU + 2%CNT presented similar release profiles, being able to ensure a controlled release of DFN for at least 4 days. Finally, in vitro cytotoxicity tests using human chondrocytes were also performed and confirmed a high biocompatibility for the three studied materials.


  • Open Access

    PVA-Based Hydrogels Loaded with Diclofenac for Cartilage Replacement

    by Ana C. Branco, Andreia S. Oliveira, Inês Monteiro, Pedro Nolasco, Diana C. Silva, Célio G. Figueiredo-Pina, Rogério Colaço, Ana P. Serro

    Polyvinyl alcohol (PVA) hydrogels have been widely studied for cartilage replacement due to their biocompatibility, chemical stability, and ability to be modified such that they approximate natural tissue behavior. Additionally, they may also be used with advantages as local drug delivery systems. However, their properties are not yet the most adequate for such applications. This work aimed to develop new PVA-based hydrogels for this purpose, displaying improved tribomechanical properties with the ability to control the release of diclofenac (DFN). Four types of PVA-based hydrogels were prepared via freeze-thawing: PVA, PVA/PAA (by polyacrylic acid (PAA) addition), PVA/PAA+PEG (by polyethylene glycol (PEG) immersion), and PVA/PAA+PEG+A (by annealing). Their morphology, water uptake, mechanical and rheological properties, wettability, friction coefficient, and drug release behavior were accessed. The irritability of the best-performing material was investigated. The results showed that the PAA addition increased the swelling and drug release amount. PEG immersion led to a more compact structure and significantly improved the material’s tribomechanical performance. The annealing treatment led to the material with the most suitable properties: besides presenting a low friction coefficient, it further enhanced the mechanical properties and ensured a controlled DFN release for at least 3 days. Moreover, it did not reveal irritability potential for biological tissues.


  • Open Access

    Hydrogels based on poly(vinyl alcohol) for cartilage substitution

    by A. S. Oliveira, R. Colaço, A. P. Serro

    Cartilage damage is an important concern because of the tissue's limited ability to repair itself [ 1 Karuppal R. Current concepts in the articular cartilage repair and regeneration. J Orthop. 2017;14:A1–3. [Crossref], [PubMed], [Web of Science ®] , [Google Scholar] , 2 Oliveira AS , Seidi O , Ribeiro N , et al. Tribomechanical comparison between PVA hydrogels obtained using different processing conditions and human cartilage. Materials. 2019;12(20):3413. [Crossref], [Web of Science ®] , [Google Scholar] ]. Among the existing strategies to replace cartilage, hydrogels have been widely considered due to their ability to easily mimic the natural tissue [ 1 Karuppal R. Current concepts in the articular cartilage repair and regeneration. J Orthop. 2017;14:A1–3. [Crossref], [PubMed], [Web of Science ®] , [Google Scholar] , 2 Oliveira AS , Seidi O , Ribeiro N , et al. Tribomechanical comparison between PVA hydrogels obtained using different processing conditions and human cartilage. Materials. 2019;12(20):3413. [Crossref], [Web of Science ®] , [Google Scholar] ]. Poly(vinyl alcohol) (PVA) based hydrogels have been the focus of a large number of studies as they are easy to produce, have excellent biocompatibility, low toxicity, high water content, and stability [ 2 Oliveira AS , Seidi O , Ribeiro N , et al. Tribomechanical comparison between PVA hydrogels obtained using different processing conditions and human cartilage. Materials. 2019;12(20):3413. [Crossref], [Web of Science ®] , [Google Scholar] ]. The aim of this study was to evaluate the effect of different preparation conditions of PVA hydrogels on the properties of the materials. PVA (MW 145000 Da) aqueous solutions (15% w/v) were prepared at 95 °C for 6 h, poured into flat moulds and cooled down to room temperature. Cast drying samples (CD4 and CD30) samples were dried at 4 and 30 °C until they reach a constant weight. Freeze-thawing samples (FT0 and FTNaCl) were prepared with 5 cycles of 10 h at −20 °C and 2 h at room temperature. For FTNaCl samples, an aqueous solution of NaCl (25% w/w) was pre-added to the initial polymer solution in a proportion of 1:10 (v/v) relative to PVA. The hydrogels were characterised concerning equilibrium water content (EWC), surface morphology (analysed by Scanning Electron Microscopy (SEM, JEOL JSM-7001F)), thermotropic behaviour (studied by differential scanning calorimeter (NETZSCH 200 F3 Maia) with thermograms being recorded over the range of 20–280 °C at a heating rate of 10 °C/min), mechanical performance (evaluated by uniaxial tensile and unconfined compression tests carried out in a TA.XT Express Texture Analyzer) and friction behaviour (pin-on-disc tests done in linear reciprocal oscillation mode using stainless steel 316 L balls as counter-bodies, with loads of 10 and 20 N, in phosphate buffered saline (PBS) solution and simulated synovial fluid (SSF) solution with hyaluronic acid and bovine serum albumin). CD4 and CD30 showed an EWC in the range of 63–66% while that of FT0 and FTNaCl varied between 87–89%. SEM micrographs revealed different structures for CD and FT samples. The surface of CD gels was smoother with no evident porosity, while FT materials exhibited holes in different porosity patterns. FTNaCl presented smaller pores than FT0, although a minor number of large pores coexist. The degree of crystallinity (35–36%), glass transition temperature (43–44 °C), and melting transition temperature (214–216 °C) were similar for all samples. Regarding mechanical performance, the elastic modulus in both compression and tensile, was inferior for the FT materials, in particular for FTNaCl. In tensile experiments, CD gels had the highest ultimate tensile strength and toughness. Concerning tribology behaviour, the friction coefficients (CoF) of all samples were low and similar in PBS solution when 10 N of force was applied. For 20 N, the CoF values of the CD materials decreased. In SSF solution, CD samples presented higher CoF with both tested forces. The properties of the PVA hydrogels were strongly influenced by the preparation conditions. CD method proved to be more suitable for producing PVA cartilage substitutes. It led to more compact, rigid, and resistant materials with adequate values of EWC and CoF.


  • Open Access

    Physically crosslinked polyvinyl alcohol hydrogels as synthetic cartilage materials

    by S. Schweizer, I. Monteiro, A.S Oliveira, P. Nolasco, R. Colaço, A.P Serro

    Polyvinyl alcohol (PVA) hydrogels have been considered very promising materials for the replacement of cartilage tissues due to their biocompatibility, chemical resistance, swelling capacity, and t...


  • Open Access

    Tough and Low Friction Polyvinyl Alcohol Hydrogels Loaded with Anti-inflammatories for Cartilage Replacement

    by Andreia Sofia Oliveira, Sara Schweizer, Pedro Nolasco, Isabel Barahona, Jorge Saraiva, Rogério Colaço, Ana Paula Serro

    The development of new materials that mimic cartilage and its function is an unmet need that will allow replacing the damaged parts of the joints, instead of the whole joint. Polyvinyl alcohol (PVA) hydrogels have raised special interest for this application due to their biocompatibility, high swelling capacity and chemical stability. In this work, the effect of post-processing treatments (annealing, high hydrostatic pressure (HHP) and gamma-radiation) on the performance of PVA gels obtained by cast-drying was investigated and, their ability to be used as delivery vehicles of the anti-inflammatories diclofenac or ketorolac was evaluated. HHP damaged the hydrogels, breaking some bonds in the polymeric matrix, and therefore led to poor mechanical and tribological properties. The remaining treatments, in general, improved the performance of the materials, increasing their crystallinity. Annealing at 150 °C generated the best mechanical and tribological results: higher resistance to compressive and tensile loads, lower friction coefficients and ability to support higher loads in sliding movement. This material was loaded with the anti-inflammatories, both without and with vitamin E (Vit.E) or Vit.E + cetalkonium chloride (CKC). Vit.E + CKC helped to control the release of the drugs which occurred in 24 h. The material did not induce irritability or cytotoxicity and, therefore, shows high potential to be used in cartilage replacement with a therapeutic effect in the immediate postoperative period.


  • Moxifloxacin-loaded acrylic intraocular lenses: In vitro and in vivo performance

    by Helena P. Filipe, Dimitriya Bozukova, Andreia Pimenta, Ana Paula Vieira, Andreia Sofia Oliveira, Raquel Galante, Ana Topete, Már Masson, Patrícia Alves, Patrícia Coimbra, et al.

    To assess the possibility of using acrylic intraocular lenses (IOLs) to ensure controlled and sustained release of moxifloxacin, an antibiotic commonly used for endophthalmitis prophylaxis after cataract surgery. Academic, industrial, and clinical partners from Portugal, Belgium, Iceland, and the United States. Experimental study. The physical properties of IOLs loaded with moxifloxacin by soaking were characterized. In vitro drug-release studies were performed under hydrodynamic conditions similar to those of the eye, and the activity of the released drug was tested. In vitro cytotoxicity was evaluated, and the in vivo efficacy of the devices was assessed through rabbit experiments in which the effects of topical moxifloxacin drops (control) and moxifloxacin-loaded IOLs were compared. The presence of moxifloxacin in the IOLs had little effect on the evaluated physical properties and did not induce cytotoxicity. In vitro drug release experiments showed that the IOLs provided controlled release of moxifloxacin for approximately 2 weeks. The drug remained active against the tested microorganisms during that period. Moxifloxacin-loaded IOLs and the control treatment induced similar in vivo behavior in terms of inflammatory reactions, capsular bag opacification scores, and uveal and capsule biocompatibility. The drug concentration in the aqueous humor after 1 week was similar in both groups; however, the concentration with the loaded IOLs was less variable. The moxifloxacin-loaded IOLs released the drug in a controlled manner, providing therapeutic levels.