SJSoraia Pilon Jürgensen

Soraia Pilon Jürgensen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Soraia Pilon Jürgensen has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Reliability and validity of six-minute step test in patients with heart failure

    by R.S. Marinho, S.P. Jürgensen, J.F. Arcuri, C.L. Goulart, P.B. dos Santos, M.G. Roscani, R.G. Mendes, C.R. de Oliveira, F.R. Caruso, A. Borghi-Silva

    Exercise intolerance is the hallmark consequence of advanced chronic heart failure (HF). The six-minute step test (6MST) has been considered an option for the six-minute walk test because it is safe, inexpensive, and can be applied in small places. However, its reliability and concurrent validity has still not been investigated in participants with HF with reduced ejection fraction (HFrEF). Clinically stable HFrEF participants were included. Reliability and error measurement were calculated by comparing the first with the second 6MST result. Forty-eight hours after participants underwent the 6MST, they were invited to perform a cardiopulmonary exercise test (CPET) on a cycle ergometer. Concurrent validity was assessed by correlation between number of steps and peak oxygen uptake (V̇O2 peak) at CPET. Twenty-seven participants with HFrEF (60±8 years old and left ventricle ejection fraction of 41±6%) undertook a mean of 94±30 steps in the 6MST. Intra-rater reliability was excellent for 6MST (ICC=0.9), with mean error of 4.85 steps and superior and inferior limits of agreement of 30.6 and -20.9 steps, respectively. In addition, strong correlations between number of steps and CPET workload (r=0.76, P<0.01) and peak V̇O2 (r=0.71, P<0.01) were observed. From simple linear regression the following predictive equations were obtained with 6MST results: V̇O2 peak (mL/min) = 350.22 + (7.333 × number of steps), with R2=0.51, and peak workload (W) = 4.044 + (0.772 × number of steps), with R2=0.58. The 6MST was a reliable and valid tool to assess functional capacity in HFrEF participants and may moderately predict peak workload and oxygen uptake of a CPET.


  • Open Access

    Validation of the two-minute step test in obese with comorbibities and morbidly obese patients

    by P.A. Ricci, R. Cabiddu, S.P. Jürgensen, L.D. André, C.R. Oliveira, L. Di Thommazo-Luporini, F.P. Ortega, A. Borghi-Silva

    Cardiopulmonary fitness assessment is a valuable resource to obtain quantitative indicators of an individual's physical performance. The cardiopulmonary exercise test (CPX), considered the gold standard test for this evaluation, is costly and difficult to be accessed by the general population. In order to make this evaluation more accessible, and to better reflect the performance of daily life activities, alternative tests were proposed. Morbidly obese patients present limitations that impair physical performance assessment and could benefit from a test of shorter duration, provided it is validated. This observational study aimed to validate the two-minute step test (2MST) as a tool to evaluate functional capacity (FC) in obese with comorbidities and morbidly obese patients, compared the 2MST with CPX as a measure of physical performance, and developed a predictive equation to estimate peak oxygen uptake (VO2) in the 2MST. The CPX and the 2MST were performed and metabolic and ventilatory parameters were recorded in 31 obese individuals (BMI>35 kg/m2). Pearson correlation and multiple linear regression analyses were performed to evaluate the peak VO2 best predictors. Bland-Altman analysis was performed to assess the agreement between the two methods. Peak VO2 measured by CPX and 2MST showed a strong correlation (r=0.70, P2 of the 2MST and the number of up-and-down step cycles (UDS) (r=0.55; P=0.01). The reference equation obtained was: VO2 (mL·kg-1·min-1) = 13.341 + 0.138 × total UDS – (0.183 × BMI), with an estimated standard error of 1.3 mL·kg-1·min-1. The 2MST is a viable, practical, and easily accessible test for FC. UDS and BMI can predict peak VO2 satisfactorily.