MFMagalie Faivre

Magalie Faivre

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Magalie Faivre has a total of 58 co-authors. Here are the top co-authors by number of shared publications:

  • Manouk Abkarian

    Centre de Biochimie Structurale, CNRS UMR 5048-INSERM UMR 1054, University of Montpellier, 34090 Montpellier, France

    5 shared publications
  • Rosaria Ferrigno

    Institut des Nanotechnologies de Lyon INL-UMR5270 CNRS, Université Lyon 1, F-69622 Villeurbanne, France

    3 shared publications
  • Anne-Laure Deman

    Institut des Nanotechnologies de Lyon (INL), CNRS UMR 5270, Université de Lyon 1, Université de Lyon , Villeurbanne F-69622, France

    2 shared publications
  • Howard A. Stone

    Department of Mechanical and Aerospace Engineering, Princeton University, Princeton, New Jersey 08544

    2 shared publications
  • Howard A. Stone

    Harvard University

    2 shared publications
  • Thomas Ward

    Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, North Carolina 27695-7910, USA

    2 shared publications

Latest Publications

  • Open Access

    Mechanical Signature of Red Blood Cells Flowing Out of a Microfluidic Constriction Is Impacted by Membrane Elasticity, Cell Surface-to-Volume Ratio and Diseases

    by Magalie Faivre, Céline Renoux, Amel Bessaa, Lydie Da Costa, Philippe Joly, Alexandra Gauthier, Philippe Connes

    Despite the fact that Red Blood Cells (RBCs) have been intensively studied in the past 50 years to characterize mechanical phenotypes associated with both healthy and pathological states, only ektacytometry (i.e., laser diffractometry) is currently used by hematologists to screen for RBC membrane disorders. Therefore, the development of new diagnostic tools able to perform analysis at the scale of a single cell, over a statistically relevant population, would provide important complementary information. But these new diagnostic tools would have to be able to discriminate between different disorders causing a change in RBCs mechanical properties. We evaluated the mechanical response of artificially rigidified RBCs flowing through a microfluidic constriction. The geometry consists in a 50 μm wide channel with a succession of 14 tooth-like patterns, each composed of a 5 μm wide and 10 μm long constriction, associated with a 25 μm wide and 10 μm long enlargement. RBCs deformability was altered using two chemical treatments, known to affect RBCs membrane surface area and membrane deformability, lysolecithine (LPC) and diamide, respectively. Differences between samples were highlighted by the representation of the inverse of the shape recovery time (1/τr), versus the extension at the exit of the constriction, Dout. The results demonstrate that our approach is able to provide a direct signature of RBCs membrane composition and architecture, as it allows discriminating the effect of changes in RBCs membrane surface area from changes in RBCs membrane deformability. Finally, in order to evaluate the potential of our microsystem to detect pathological cells, we have performed preliminary experiments on patients with Hereditary Spherocytosis (HS) or Sickle Cell Anemia (SCA).


  • Open Access

    Dual shape recovery of red blood cells flowing out of a microfluidic constriction

    by A. Amirouche, J. Esteves, A. Lavoignat, S. Picot, R. Ferrigno, M. Faivre

    Micropipette aspiration, optical tweezers, rheometry, or ecktacytometry have been used to study the shape recovery of healthy human Red Blood Cells (RBCs) and measure associated relaxation times of the order of 100–300 ms. These measurements are in good agreement with the Kelvin–Voigt model, which describes the cell as a visco-elastic material, predicting that its relaxation time only depends on cell intrinsic properties. However, such mechanical solicitation techniques are far from being relevant regarding RBC solicitation in vivo. In this paper, we report for the first time the existence of two different behaviors of the RBC shape recovery while flowing out of a microfluidic constricted channel. The calculation of the viscous stress corresponding to the frontier between the two recovery modes confirms that the RBC resistance to shear μ is the elastic property dominating the transition between the two recovery behaviors. We also quantified associated recovery times τ r and report values as low as 4 ms—which is almost two decades smaller than the typical RBC relaxation time—at high viscosity and flow velocity of the carrier fluid. Although we cannot talk about relaxation time because the cell is never at rest, we believe that the measured shape recovery time arises from the coupling of the cell intrinsic deformability and the hydrodynamic stress. Depending on the flow conditions, the cell mechanics becomes dominant and drives the shape recovery process, allowing the measurement of recovery times of the same order of magnitude than relaxation times previously published. Finally, we demonstrated that the measurement of the shape recovery time can be used to distinguish Plasmodium falciparum (causing malaria) infected RBCs from healthy RBCs.


  • Mechanics for Fluidics and Bio-Devices

    by Luis Guillermo Villanueva, Annalisa De Pastina, Magalie Faivre

  • Open Access

    Comparison of ITO and IrOx-Modified ITO Interdigitated Electrodes for Electrical Cell-Substrate Impedance Sensing (ECIS) Applications

    by Jaime Martinez, Amalric Montalibet, Eric McAdams, Magalie Faivre, Rosaria Ferrigno

    This study compares the sensitivity of interdigitated electrodes (IDEs) used in Electrical Cell-Substrate Impedance Sensing (ECIS). IDEs made of indium tin oxide (ITO) and ITO coated with iridium oxide (IrOx) were used for ECIS measurements with the human breast cancer cell line, MCF-7. The results indicate that IrOx-modified ITO electrodes provide both biocompatibility and higher cell sensitivity compared to ITO electrodes. We also found that the quantity of IrOx required to generate such a sensitivity improvement is sufficiently low to not interfere with the visualization of the cells under study. IrOx-modified ITO electrodes are therefore promising sensors for ECIS applications.


  • Open Access

    Impact of Channel Geometry on the Discrimination of Mechanically Impaired Red Blood Cells in Passive Microfluidics

    by Amin Amirouche, Rosaria Ferrigno, Magalie Faivre

    In this work, we aimed at the discrimination of mechanically impaired red blood cells (RBCs) using passive microfluidic approaches. We investigated the impact of the channel geometry on the behavior of healthy RBCs (hRBCs) and thermally rigidified RBCs (T-rRBCs) flowing in (i) a Unique and Long Constriction (ULC) and (ii) a series of Oscillating Width Constrictions (OWC). To confront the two geometries, we evaluated potential biomarkers for cell discrimination such as their speed V, deformation index D and relaxation time τ.


  • Dielectrophoretic capture of low abundance cell population using thick electrodes

    by Julien Marchalot, Jean-François Chateaux, Magalie Faivre, Hichem C. Mertani, Rosaria Ferrigno, Anne-Laure Deman

    Enrichment of rare cell populations such as Circulating Tumor Cells (CTCs) is a critical step before performing analysis. This paper presents a polymeric microfluidic device with integrated thick Carbon-PolyDimethylSiloxane composite (C-PDMS) electrodes designed to carry out dielectrophoretic (DEP) trapping of low abundance biological cells. Such conductive composite material presents advantages over metallic structures. Indeed, as it combines properties of both the matrix and doping particles, C-PDMS allows the easy and fast integration of conductive microstructures using a soft-lithography approach while preserving O2 plasma bonding properties of PDMS substrate and avoiding a cumbersome alignment procedure. Here, we first performed numerical simulations to demonstrate the advantage of such thick C-PDMS electrodes over a coplanar electrode configuration. It is well established that dielectrophoretic force (FDEP ) decreases quickly as the distance from the electrode surface increases resulting in coplanar configuration to a low trapping efficiency at high flow rate. Here, we showed quantitatively that by using electrodes as thick as a microchannel height, it is possible to extend the DEP force influence in the whole volume of the channel compared to coplanar electrode configuration and maintaining high trapping efficiency while increasing the throughput. This model was then used to numerically optimize a thick C-PDMS electrode configuration in terms of trapping efficiency. Then, optimized microfluidic configurations were fabricated and tested at various flow rates for the trapping of MDA-MB-231 breast cancer cell line. We reached trapping efficiencies of 97% at 20 μl/h and 78.7% at 80 μl/h, for 100 μm thick electrodes. Finally, we applied our device to the separation and localized trapping of CTCs (MDA-MB-231) from a red blood cells sample (concentration ratio of 1:10).


  • Magnetophoretic manipulation in microsystem using carbonyl iron-polydimethylsiloxane microstructures

    by Magalie Faivre, Renaud Gelszinnis, Jérôme Degouttes, Nicolas Terrier, Charlotte Rivière, Rosaria Ferrigno, Anne-Laure Deman

    This paper reports the use of a recent composite material, noted hereafter i-PDMS, made of carbonyl iron microparticles mixed in a PolyDiMethylSiloxane (PDMS) matrix, for magnetophoretic functions such as capture and separation of magnetic species. We demonstrated that this composite which combine the advantages of both components, can locally generate high gradients of magnetic field when placed between two permanent magnets. After evaluating the magnetic susceptibility of the material as a function of the doping ratio, we investigated the molding resolution offered by i-PDMS to obtain microstructures of various sizes and shapes. Then, we implemented 500 μm i-PDMS microstructures in a microfluidic channel and studied the influence of flow rate on the deviation and trapping of superparamagnetic beads flowing at the neighborhood of the composite material. We characterized the attraction of the magnetic composite by measuring the distance from the i-PDMS microstructure, at which the beads are either deviated or captured. Finally, we demonstrated the interest of i-PDMS to perform magnetophoretic functions in microsystems for biological applications by performing capture of magnetically labeled cells.


  • Gel Phase Vesicles Buckle into Specific Shapes

    by François Quemeneur, Catherine Quilliet, Magalie Faivre, Annie Viallat, Brigitte Pépin-Donat

    Osmotic deflation of giant vesicles in the rippled gel phase P$\beta${}$'${} gives rise to a large variety of novel faceted shapes. These shapes are also found from a numerical approach by using an elastic surface model. A shape diagram is proposed based on the model that accounts for the vesicle size and ratios of three mechanical constants: in-plane shear elasticity and compressibility (usually neglected) and out-of-plane bending of the membrane. The comparison between experimental and simulated vesicle morphologies reveals that they are governed by a typical elasticity length, of the order of 1\,\hskip0.056em\hskip0.056em$\mu${}m, and must be described with a large Poisson's ratio.


  • Ultrasound internal tattooing

    by Olivier Couture, Magalie Faivre, Nicolas Pannacci, Avin Babataheri, Vincent Servois, Patrick Tabeling, Mickael Tanter

    Purpose: The ability of remotely tagging tissues in a controlled and three‐dimensional manner during preoperative imaging could greatly help surgeons to identify targets for resection. The authors' objective is to selectively and noninvasively deposit markers under image guidance for such internal tattooing.Methods: This study describes the production of new ultrasound‐inducible droplets carrying large payloads of fluorescent markers and thein vivo proof of concept of their remote and controlled deposition via focused ultrasound. The droplets are monodispersed multiple emulsions produced in a microfluidic system, consisting of aqueous fluorescein in perfluorocarbon in water. Their conversion (either by vaporization or cavitation) is performed remotely using a clinical ultrasonic imaging probe.Results: When submitted to 5 MHz imaging pulses, the droplets vaporizein vitro at 1.4 MPa peak‐negative pressure and eject their content. After several seconds, a brightly fluorescent spot (0.5 mm diameter) is observed at the focus of the transducer. Experiments in the chorioallantoique membrane of chicken eggs and chicken embryo demonstrate that the spot is stable and is easily seen by naked eye.Conclusions: These ultrasound‐inducible multiple emulsions could be used to deliver large amounts of contrast agents, chemotherapy, and genetic materialsin vivo using a conventional ultrasound scanner.


  • Open Access

    Coagulation dynamics of a blood sample by multiple scattering analysis

    by Magalie Faivre, Philippe Peltié, Anne Planat-ChrétIen, Marie-Line Cosnier, Myriam Cubizolles, Christophe Nougier, Claude NégRier, Patrick Pouteau

    Coagulation is an important part of the haemostasis process corresponding to the cessation of blood loss from a damaged vessel. The coagulation mechanism implies a complex series of cascading enzymatic reactions involving proteins, referred to as coagulation factors. In order to diagnose disorders in these coagulation factors, different biological tests have been developed (prothrombin time, activated partial thromboplastin time, activated cephalin clotting time, etc.). Coagulation disorders can lead to an increased risk of haemorrhage or thrombosis. Moreover, according to the International Self-Monitoring Association of Oral Anticoagulated Patients (ISMAAP), nearly four milion people are under oral anticoagulant therapy in Europe and need to monitor their coagulation time daily to self-adjust the dosage of their treatment and thus maintain the optimal therapeutic range.