TMTaketoshi Mori

Taketoshi Mori

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Taketoshi Mori has a total of 276 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Generative Artificial Intelligence for Enhancing Nursing Educators’ Awareness and Attitudes

    by Tomoko Majima, Asahiko Higashitsuji, Tomoko Otsuka, Taketoshi Mori, Shinichiroh Yokota, Yuria Yamasaki, Aya Ishii, Shu Chun Chien, Yoshiko Wazumi

  • Open Access

    Factors Associated with Callus Formation in the Plantar Region through Gait Measurement in Patients with Diabetic Neuropathy: An Observational Case-Control Study

    by Ayumi Amemiya, Hiroshi Noguchi, Makoto Oe, Kimie Takehara, Yumiko Ohashi, Ryo Suzuki, Toshimasa Yamauchi, Takashi Kadowaki, Hiromi Sanada, Taketoshi Mori

    Callus has been identified as a risk factor leading to severe diabetic foot ulcer; thus, it is necessary to prevent its formation. Callus formation under the first, second, and fifth metatarsal heads (MTHs) is associated with external forces (pressure and shear stress) during walking. However, the gait factors increasing the external forces remain undetermined. Thus, this study aims to identify the factors increasing the external forces to prevent callus formation. In 59 patients with diabetic neuropathy wearing their usual shoes, the external forces, and the lower extremity joint angles were measured using MEMS force sensors and motion sensors. The external forces and their relationship with the lower extremity joint angles and footwear size were determined. Risk factors causing high external forces on the first MTH included small flexion of the knee joint (p = 0.015) and large ankle pronation motion (p = 0.034) to obtain propulsion. For the second MTH, wearing excessively long footwear was identified (p = 0.026). For the fifth MTH, high external force was related to tight width footwear (p = 0.005). An effective intervention for preventing callus formation for the first MTH would involve assisting the push-off foot motion using rocker-sole footwear or gait training. For the second and fifth MTHs, wearing appropriate size footwear would be effective.


  • Catheter tips are a possible resource for biological study on catheter failure

    by Toshiaki Takahashi, Takeo Minematsu, Ryoko Murayama, Gojiro Nakagami, Taketoshi Mori, Hiromi Sanada

    Few studies have investigated the molecular mechanisms of catheter failure (CF). Herein, we performed histological and molecular biological analyses of the catheter tip to demonstrate its potential as a resource for biological investigation. Additionally, we searched for risk factors for the development of inflammation and coagulation, which are pathological conditions clarified by biological analysis. The CF group included 30 failed catheters involving thrombus and subcutaneous edema identified by ultrasonography. The No-CF group included 26 catheters with no complications. The removed catheter tips were fixed for hematoxylin-eosin (HE) staining with the application of a real-time reverse transcriptase polymerase chain reaction for eukaryotic 18S ribosomal RNA (rRNA), interleukin 1β, tumor necrosis factor α, tissue plasminogen activator, and plasminogen activator inhibitor 1 (SERPINE1). HE staining identified attached nuclear cells on the inner surfaces of both CF and No-CF catheters. The 18S rRNA was amplified in all samples. The expression level of SERPINE1 was significantly higher in the CF group than in the No-CF group (p = 0.01), whereas the expression levels of other genes did not differ between the groups. Symptoms of CF associated with the expression of SERPINE1 were analyzed. The catheter being in contact with blood vessels during placement was a suggested factor related to the high expression of SERPINE1 (p = 0.04). Catheter tips are a potential resource for biological investigation, and expression analysis of the attached cells can reflect the pathological condition of the catheterized tissue. Further studies using catheter tips are required to elucidate the molecular mechanisms of CF.


  • Unintentional body movement parameters and pulse rate variability parameters are associated with the desire to void

    by Shuhei Noyori, Gojiro Nakagami, Hiroshi Noguchi, Taketoshi Mori, Hiromi Sanada

    Urinary incontinence is highly prevalent in elderly populations with physical and cognitive impairment. For the assessment and care of urinary incontinence, the desire to void is important. We have developed a bed sensor system that non-invasively and unconstrainedly measures the parameter changes of unintentional body movements. This study is aimed to evaluate the validity of measurement by the sensor system and parameters in healthy adults. We conducted experiments on 29 healthy adult volunteers. The parameters were unintentional body movement derived from changes in center of gravity and pulse rate variability (PRV) based on pulse wave measurements using a finger probe; further the relationship between the desire to void and measured parameters were examined. The body movement parameters at the buttock and thigh were associated with the desire to void (p < 0.050). All the PRV parameters trended significantly with desire to void as well (p < 0.050). The parameters achieved sensitivities of 0.18-0.88 in estimating strong desire to void, and 7 among 14 sensitivity measurements included in the receiver operating characteristic analysis exceeded 0.70. The body movement parameters and PRV parameters were useful in the estimation of the desire to void in healthy adults. To achieve accurate estimation, a combination of the PRV parameters and body movement parameters is required.

  • Open Access

    Examination of the Effect of Suitable Size of Shoes under the Second Metatarsal Head and Width of Shoes under the Fifth Metatarsal Head for the Prevention of Callus Formation in Healthy Young Women

    by Ryutaro Kase, Ayumi Amemiya, Rena Okonogi, Hiroki Yamakawa, Hisayoshi Sugawara, Yuji L. Tanaka, Masatoshi Komiyama, Taketoshi Mori

    Excessive pressure and shear stress while walking cause a risk of callus formation, which eventually causes foot ulcers in patients with diabetes mellitus. Callus under the second metatarsal head (MTH) has been associated with increased shear stress/pressure ratios (SPR). Callus under the fifth MTH has been associated with increased peak shear stress (PSS). The purpose of this study is to examine whether the effect of the suitable size and width of shoes prevents diabetic foot ulcers under the second and fifth MTH. We measured the pressure and shear stress by testing three kinds of sizes and two types of width of shoes. Significant difference was not observed in the SPR under the second MTH among different sizes of shoes. However, the pressure and shear stress were significantly lower when putting on shoes of fit size compared with larger sizes. The PSS under the fifth MTH was significantly smaller when putting on shoes of fit width compared with those of narrow width. Wearing shoes of fit size and width has the potential to prevent callus formation by reducing the pressure and shear stress constituting SPR under the second MTH and PSS under the fifth MTH.


  • Acceptance and Practical Use of Assistive Technologies for Frail Seniors and Caregivers: Interview Surveys on Nursing Homes

    by Akihiko Kamesawa, Reina Yoshizaki, Shiho Hirose, Nana Shinozaki, Ren Komatsu, Satomi Kitamura, Ou Fu, Ningjia Yang, Ayako Ishii, Yuka Sumikawa, et al.


  • Development of Personalized Fitting Device With 3-Dimensional Solution for Prevention of NIV Oronasal Mask-Related Pressure Ulcers

    by Maiko Shikama, Gojiro Nakagami, Hiroshi Noguchi, Taketoshi Mori, Hiromi Sanada

    BACKGROUND: Pressure ulcers related to oronasal masks used with noninvasive ventilation (NIV), along with patient discomfort, occur due to improper fit of the mask. We developed a personalized fitting device using a 3-dimensional (3D) scanning solution to prevent the formation of NIV mask-related pressure ulcers. This study aimed to evaluate the effectiveness of the proposed personalized fitting device. METHODS: We conducted a randomized crossover experimental study of 20 healthy participants to study the use of this personalized fitting device between the face and an NIV mask designed with 3D solutions. The fitting device was not used under the NIV mask for the control. The outcome measures were the presence of blanchable erythema, standardized redness intensity, discomfort level, and contact pressure. RESULTS: The incidence of blanchable erythema and standardized redness intensity values were significantly lower for subjects who used the fitting device when worn for 30 min ( P < .001). The discomfort levels at the forehead, nasal bridge, and both cheeks, as well as leakage, were significantly reduced as well ( P = .008, P < .001, P = .001, P = .002, P = .001, P = .02, P < .001, P < .001, P < .001). Contact pressure at the nasal bridge, where pressure ulcers most frequently develop, was significantly decreased with the fitting device ( P < .001). CONCLUSIONS: Personalized fitting devices that incorporate 3D scanning solutions may contribute to the prevention of NIV mask-related pressure ulcers and the reduction of discomfort.


  • Open Access

    A Randomized Controlled Trial to Investigate the Effectiveness of the Prevention of Aspiration Pneumonia Using Recommendations for Swallowing Care Guided by Ultrasound Examination

    by Yuka Miura, Gojiro Nakagami, Koichi Yabunaka, Haruka Tohara, Hiroshi Noguchi, Taketoshi Mori, Hiromi Sanada

    Prevention for aspiration pneumonia requires assessment of aspiration and adequate swallowing care. This randomized controlled trial aimed to investigate the effectiveness of ultrasound examination and recommendations for swallowing care for the reduction of aspiration and pharyngeal post-swallow residue as compared with standard swallowing care. Twenty-three participants were randomized to the intervention group and 23 to the control group. The intervention consisted of four ultrasound examinations during mealtimes and recommendations for swallowing care every 2 weeks during an 8 week period. No recommendations concerning swallowing care based on ultrasound examinations were provided to the control group. The frequency of aspiration or residue was defined as x/y × 100% when aspiration or residue were detected x times from y times concerning the total ultrasound measurements. The proportion of the residents with reduced frequency of aspiration which was detected by ultrasonography at eight weeks were 4.3% in the intervention group and 0% in the control group. The median reduction in the frequency of aspiration and residue in the intervention group was 31%, and that in the control group was 11%. In conclusion, swallowing care guided by frequent ultrasound examinations during mealtimes had a trend of reducing the frequency of aspiration and residue during an 8-week period in individuals relative to standard swallowing care alone.


  • The external force associated with callus formation under the first metatarsal head is reduced by wearing rocker sole shoes

    by Ayumi Amemiya, Rena Okonogi, Hiroki Yamakawa, Kaori Susumu, Tatsuya Jitsuishi, Hisayoshi Sugawara, Yuji L. Tanaka, Masatoshi Komiyama, Taketoshi Mori

    Introduction: Callus is one of the main causes of diabetic foot ulcers. Therefore, preventing callus formation is very important. In a previous study, it was clarified that callus formation under the first metatarsal head (MTH) is associated with high shear stress time integral/pressure time integral (SPR-i). another study, it was clarified that rocker sole shoes are effective in reducing peak pressure under the first MTH. Therefore, we hypothesized that rocker sole shoes reduce SPR-i under the first MTH. This study aimed to clarify the effect of rocker sole shoes for external forces and leg motions in comparison with that of the normal sole shoes. Methods: In-shoe external forces and leg motions were measured during walking wearing the normal sole shoes or the rocker sole shoes in healthy participants. As the external forces, the peak plantar pressure (PP), pressure time integral (PI), peak shear stress (PSS), and shear stress integral (SSI) of each gait cycle were calculated. Additionally, shear stress-pressure ratios (SPR) were calculated by dividing shear stress by pressure; concretely, peak values (SPR-p) and time integral values (SPR-i). As the leg motion, hip and knee joint motions were analyzed for the axis of flexion- extension. Three axes of ankle joint motion (inversion-eversion, plantar flexion-dorsiflexion, and adduction-abduction) were analyzed. Results and Discussion: Six participants attended, and twelve feet were analyzed. When wearing the rocker sole shoes, the SPR-i under the first MTH was significantly smaller than when wearing the normal sole shoes. The SPR-i higher than 0.60 is associated with callus formation under the first MTH. In three of five feet with callus, SPR-i exceeded 0.60 in the normal sole shoes. The SPR-i of all three feet became smaller than 0.60 when wearing the rocker sole shoes. Although the knee (flexion-extension) and ankle (plantar flexion-dorsiflexion) joint motion became smaller when wearing the rocker sole shoes, there was no significant difference in walking speed. It is considered that propulsion was maintained by the push-off support provided by rocker sole shoes. Conclusion: It was suggested that rocker sole shoes are effective preventing callus formation under the first MTH.