Peter Wakholi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Peter Wakholi has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Thorkild Tylleskär
University of Bergen
5 shared publications - Alice Mugisha
University of Bergen
3 shared publications - Ankica Babic
University of Bergen
3 shared publications - Michael S. Balikuddembe
Centre for International Health, University of Bergen, P O Box 7800, 5020, Bergen, Norway.
3 shared publications - Nazarius Mbona Tumwesigye
Department of Epidemiology and Biostatistics, School of Public Health, College of Health Sciences, Makerere University, Kampala P.O. Box 7072, Uganda
3 shared publications
Latest Publications
- Open Access
- 18 November 2019
- Published by JMIR Publications Inc. in JMIR Public Health and Surveillance
A childbirth monitoring algorithm with fewer variables than the modified WHO partograph: design and expert validation. (Preprint)
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: After determining the key childbirth monitoring items from experts in childbirth, we designed an algorithm to represent the experts’ suggestions and we validated it. Objective: In this paper we describe the abridged algorithm for labour and delivery (LaD) management and use theoretical case to compare its performance to human childbirth experts. Methods: The LaD algorithm encompasses the tracking of six of the 12 childbirth parameters monitored using the World Health Organisation partograph. It has recommendations on how to manage a patient when parameters are outside the normal ranges. We validated the algorithm with purposively selected experts selecting actions for a stratified sample of patient case scenarios. The experts’ selections were compared to get pairwise sensitivity and false positive rates (FPR) between them and the algorithm. Results: The mean weighted pairwise sensitivity among experts was 68.2% (StD. 6.95; CI. 59.6, 76.8) while that between the experts and LaD algorithm was 69.4% (StD. 17.95; CI. 47.1, 91.7). The pairwise FPR amongst the experts ranged from 12% to 33% with a mean of 23.9% (CI. 12.6, 35.2) and that between the experts and the algorithm ranged from 18% to 43% (mean 26.3%; CI. 13.3, 39.3). The was a correlation (mean of 0.67) in the actions selected by the expert pairs for the different patient cases with a reliability coefficient 0.91. Conclusions: The LaD algorithm and the childbirth experts were not statistically different. An electronic tool for childbirth monitoring with fewer than WHO-recommended parameters may not be inferior to human experts in labour and delivery clinical decision support.
- 18 November 2019
- Published by JMIR Publications Inc. in JMIR Public Health and Surveillance
Open AccessA childbirth monitoring algorithm with fewer variables than the modified WHO partograph: design and expert validation. (Preprint)
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: After determining the key childbirth monitoring items from experts in childbirth, we designed an algorithm to represent the experts’ suggestions and we validated it. Objective: In this paper we describe the abridged algorithm for labour and delivery (LaD) management and use theoretical case to compare its performance to human childbirth experts. Methods: The LaD algorithm encompasses the tracking of six of the 12 childbirth parameters monitored using the World Health Organisation partograph. It has recommendations on how to manage a patient when parameters are outside the normal ranges. We validated the algorithm with purposively selected experts selecting actions for a stratified sample of patient case scenarios. The experts’ selections were compared to get pairwise sensitivity and false positive rates (FPR) between them and the algorithm. Results: The mean weighted pairwise sensitivity among experts was 68.2% (StD. 6.95; CI. 59.6, 76.8) while that between the experts and LaD algorithm was 69.4% (StD. 17.95; CI. 47.1, 91.7). The pairwise FPR amongst the experts ranged from 12% to 33% with a mean of 23.9% (CI. 12.6, 35.2) and that between the experts and the algorithm ranged from 18% to 43% (mean 26.3%; CI. 13.3, 39.3). The was a correlation (mean of 0.67) in the actions selected by the expert pairs for the different patient cases with a reliability coefficient 0.91. Conclusions: The LaD algorithm and the childbirth experts were not statistically different. An electronic tool for childbirth monitoring with fewer than WHO-recommended parameters may not be inferior to human experts in labour and delivery clinical decision support.
- Open Access
- 18 November 2019
- Published by JMIR Publications Inc. in JMIR Preprints
An Algorithm (LaD) for Monitoring Childbirth in Settings Where Tracking All Parameters in the World Health Organization Partograph Is Not Feasible: Design and Expert Validation (Preprint)
BACKGROUND After determining the key childbirth monitoring items from experts, we designed an algorithm (LaD) to represent the experts’ suggestions and validated it. In this paper we describe an abridged algorithm for labor and delivery management and use theoretical case to compare its performance with human childbirth experts. OBJECTIVE The objective of this study was to describe the LaD algorithm, its development, and its validation. In addition, in the validation phase we wanted to assess if the algorithm was inferior, equivalent, or superior to human experts in recommending the necessary clinical actions during childbirth decision making. METHODS The LaD algorithm encompasses the tracking of 6 of the 12 childbirth parameters monitored using the World Health Organization (WHO) partograph. It has recommendations on how to manage a patient when parameters are outside the normal ranges. We validated the algorithm with purposively selected experts selecting actions for a stratified sample of patient case scenarios. The experts’ selections were compared to obtain pairwise sensitivity and false-positive rates (FPRs) between them and the algorithm. RESULTS The mean weighted pairwise sensitivity among experts was 68.2% (SD 6.95; 95% CI 59.6-76.8), whereas that between experts and the LaD algorithm was 69.4% (SD 17.95; 95% CI 47.1-91.7). The pairwise FPR among the experts ranged from 12% to 33% with a mean of 23.9% (SD 9.14; 95% CI 12.6-35.2), whereas that between experts and the algorithm ranged from 18% to 43% (mean 26.3%; SD 10.4; 95% CI 13.3-39.3). The was a correlation (mean 0.67 [SD 0.06]) in the actions selected by the expert pairs for the different patient cases with a reliability coefficient (α) of .91. CONCLUSIONS The LaD algorithm was more sensitive, but had a higher FPR than the childbirth experts, although the differences were not statistically significant. An electronic tool for childbirth monitoring with fewer WHO-recommended parameters may not be inferior to human experts in labor and delivery clinical decision support.
- 18 November 2019
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessAn Algorithm (LaD) for Monitoring Childbirth in Settings Where Tracking All Parameters in the World Health Organization Partograph Is Not Feasible: Design and Expert Validation (Preprint)
BACKGROUND After determining the key childbirth monitoring items from experts, we designed an algorithm (LaD) to represent the experts’ suggestions and validated it. In this paper we describe an abridged algorithm for labor and delivery management and use theoretical case to compare its performance with human childbirth experts. OBJECTIVE The objective of this study was to describe the LaD algorithm, its development, and its validation. In addition, in the validation phase we wanted to assess if the algorithm was inferior, equivalent, or superior to human experts in recommending the necessary clinical actions during childbirth decision making. METHODS The LaD algorithm encompasses the tracking of 6 of the 12 childbirth parameters monitored using the World Health Organization (WHO) partograph. It has recommendations on how to manage a patient when parameters are outside the normal ranges. We validated the algorithm with purposively selected experts selecting actions for a stratified sample of patient case scenarios. The experts’ selections were compared to obtain pairwise sensitivity and false-positive rates (FPRs) between them and the algorithm. RESULTS The mean weighted pairwise sensitivity among experts was 68.2% (SD 6.95; 95% CI 59.6-76.8), whereas that between experts and the LaD algorithm was 69.4% (SD 17.95; 95% CI 47.1-91.7). The pairwise FPR among the experts ranged from 12% to 33% with a mean of 23.9% (SD 9.14; 95% CI 12.6-35.2), whereas that between experts and the algorithm ranged from 18% to 43% (mean 26.3%; SD 10.4; 95% CI 13.3-39.3). The was a correlation (mean 0.67 [SD 0.06]) in the actions selected by the expert pairs for the different patient cases with a reliability coefficient (α) of .91. CONCLUSIONS The LaD algorithm was more sensitive, but had a higher FPR than the childbirth experts, although the differences were not statistically significant. An electronic tool for childbirth monitoring with fewer WHO-recommended parameters may not be inferior to human experts in labor and delivery clinical decision support.
- Open Access
- 22 March 2019
- Published by JMIR Publications Inc. in JMIR Human Factors
- Vol. 6 (1) , e11852
High-Fidelity Prototyping for Mobile Electronic Data Collection Forms Through Design and User Evaluation
Background: Mobile data collection systems are often difficult to use for nontechnical or novice users. This can be attributed to the fact that developers of such tools do not adequately involve end users in the design and development of product features and functions, which often creates interaction challenges. Objective: The main objective of this study was to assess the guidelines for form design using high-fidelity prototypes developed based on end-user preferences. We also sought to investigate the association between the results from the System Usability Scale (SUS) and those from the Study Tailored Evaluation Questionnaire (STEQ) after the evaluation. In addition, we sought to recommend some practical guidelines for the implementation of the group testing approach particularly in low-resource settings during mobile form design. Methods: We developed a Web-based high-fidelity prototype using Axure RP 8. A total of 30 research assistants (RAs) evaluated this prototype in March 2018 by completing the given tasks during 1 common session. An STEQ comprising 13 affirmative statements and the commonly used and validated SUS were administered to evaluate the usability and user experience after interaction with the prototype. The STEQ evaluation was summarized using frequencies in an Excel sheet while the SUS scores were calculated based on whether the statement was positive (user selection minus 1) or negative (5 minus user selection). These were summed up and the score contributions multiplied by 2.5 to give the overall form usability from each participant. Results: Of the RAs, 80% (24/30) appreciated the form progress indication, found the form navigation easy, and were satisfied with the error messages. The results gave a SUS average score of 70.4 (SD 11.7), which is above the recommended average SUS score of 68, meaning that the usability of the prototype was above average. The scores from the STEQ, on the other hand, indicated a 70% (21/30) level of agreement with the affirmative evaluation statements. The results from the 2 instruments indicated a fair level of user satisfaction and a strong positive association as shown by the Pearson correlation value of .623 (P<.01). Conclusions: A high-fidelity prototype was used to give the users experience with a product they would likely use in their work. Group testing was done because of scarcity of resources such as costs and time involved especially in low-income countries. If embraced, this approach could help assess user needs of the diverse user groups. With proper preparation and the right infrastructure at an affordable cost, usability testing could lead to the development of highly usable forms. The study thus makes recommendations on the practical guidelines for the implementation of the group testing approach particularly in low-resource settings during mobile form design.
- 22 March 2019
- Published by JMIR Publications Inc. in JMIR Human Factors
- Vol. 6 (1) , e11852
Open AccessHigh-Fidelity Prototyping for Mobile Electronic Data Collection Forms Through Design and User Evaluation
Background: Mobile data collection systems are often difficult to use for nontechnical or novice users. This can be attributed to the fact that developers of such tools do not adequately involve end users in the design and development of product features and functions, which often creates interaction challenges. Objective: The main objective of this study was to assess the guidelines for form design using high-fidelity prototypes developed based on end-user preferences. We also sought to investigate the association between the results from the System Usability Scale (SUS) and those from the Study Tailored Evaluation Questionnaire (STEQ) after the evaluation. In addition, we sought to recommend some practical guidelines for the implementation of the group testing approach particularly in low-resource settings during mobile form design. Methods: We developed a Web-based high-fidelity prototype using Axure RP 8. A total of 30 research assistants (RAs) evaluated this prototype in March 2018 by completing the given tasks during 1 common session. An STEQ comprising 13 affirmative statements and the commonly used and validated SUS were administered to evaluate the usability and user experience after interaction with the prototype. The STEQ evaluation was summarized using frequencies in an Excel sheet while the SUS scores were calculated based on whether the statement was positive (user selection minus 1) or negative (5 minus user selection). These were summed up and the score contributions multiplied by 2.5 to give the overall form usability from each participant. Results: Of the RAs, 80% (24/30) appreciated the form progress indication, found the form navigation easy, and were satisfied with the error messages. The results gave a SUS average score of 70.4 (SD 11.7), which is above the recommended average SUS score of 68, meaning that the usability of the prototype was above average. The scores from the STEQ, on the other hand, indicated a 70% (21/30) level of agreement with the affirmative evaluation statements. The results from the 2 instruments indicated a fair level of user satisfaction and a strong positive association as shown by the Pearson correlation value of .623 (P<.01). Conclusions: A high-fidelity prototype was used to give the users experience with a product they would likely use in their work. Group testing was done because of scarcity of resources such as costs and time involved especially in low-income countries. If embraced, this approach could help assess user needs of the diverse user groups. With proper preparation and the right infrastructure at an affordable cost, usability testing could lead to the development of highly usable forms. The study thus makes recommendations on the practical guidelines for the implementation of the group testing approach particularly in low-resource settings during mobile form design.
- Open Access
- 7 August 2018
- Published by JMIR Publications Inc. in JMIR Preprints
High-Fidelity Prototyping for Mobile Electronic Data Collection Forms Through Design and User Evaluation (Preprint)
BACKGROUND Mobile data collection systems are often difficult to use for nontechnical or novice users. This can be attributed to the fact that developers of such tools do not adequately involve end users in the design and development of product features and functions, which often creates interaction challenges. OBJECTIVE The main objective of this study was to assess the guidelines for form design using high-fidelity prototypes developed based on end-user preferences. We also sought to investigate the association between the results from the System Usability Scale (SUS) and those from the Study Tailored Evaluation Questionnaire (STEQ) after the evaluation. In addition, we sought to recommend some practical guidelines for the implementation of the group testing approach particularly in low-resource settings during mobile form design. METHODS We developed a Web-based high-fidelity prototype using Axure RP 8. A total of 30 research assistants (RAs) evaluated this prototype in March 2018 by completing the given tasks during 1 common session. An STEQ comprising 13 affirmative statements and the commonly used and validated SUS were administered to evaluate the usability and user experience after interaction with the prototype. The STEQ evaluation was summarized using frequencies in an Excel sheet while the SUS scores were calculated based on whether the statement was positive (user selection minus 1) or negative (5 minus user selection). These were summed up and the score contributions multiplied by 2.5 to give the overall form usability from each participant. RESULTS Of the RAs, 80% (24/30) appreciated the form progress indication, found the form navigation easy, and were satisfied with the error messages. The results gave a SUS average score of 70.4 (SD 11.7), which is above the recommended average SUS score of 68, meaning that the usability of the prototype was above average. The scores from the STEQ, on the other hand, indicated a 70% (21/30) level of agreement with the affirmative evaluation statements. The results from the 2 instruments indicated a fair level of user satisfaction and a strong positive association as shown by the Pearson correlation value of .623 (P<.01). CONCLUSIONS A high-fidelity prototype was used to give the users experience with a product they would likely use in their work. Group testing was done because of scarcity of resources such as costs and time involved especially in low-income countries. If embraced, this approach could help assess user needs of the diverse user groups. With proper preparation and the right infrastructure at an affordable cost, usability testing could lead to the development of highly usable forms. The study thus makes recommendations on the practical guidelines for the implementation of the group testing approach particularly in low-resource settings during mobile form design.
- 7 August 2018
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessHigh-Fidelity Prototyping for Mobile Electronic Data Collection Forms Through Design and User Evaluation (Preprint)
BACKGROUND Mobile data collection systems are often difficult to use for nontechnical or novice users. This can be attributed to the fact that developers of such tools do not adequately involve end users in the design and development of product features and functions, which often creates interaction challenges. OBJECTIVE The main objective of this study was to assess the guidelines for form design using high-fidelity prototypes developed based on end-user preferences. We also sought to investigate the association between the results from the System Usability Scale (SUS) and those from the Study Tailored Evaluation Questionnaire (STEQ) after the evaluation. In addition, we sought to recommend some practical guidelines for the implementation of the group testing approach particularly in low-resource settings during mobile form design. METHODS We developed a Web-based high-fidelity prototype using Axure RP 8. A total of 30 research assistants (RAs) evaluated this prototype in March 2018 by completing the given tasks during 1 common session. An STEQ comprising 13 affirmative statements and the commonly used and validated SUS were administered to evaluate the usability and user experience after interaction with the prototype. The STEQ evaluation was summarized using frequencies in an Excel sheet while the SUS scores were calculated based on whether the statement was positive (user selection minus 1) or negative (5 minus user selection). These were summed up and the score contributions multiplied by 2.5 to give the overall form usability from each participant. RESULTS Of the RAs, 80% (24/30) appreciated the form progress indication, found the form navigation easy, and were satisfied with the error messages. The results gave a SUS average score of 70.4 (SD 11.7), which is above the recommended average SUS score of 68, meaning that the usability of the prototype was above average. The scores from the STEQ, on the other hand, indicated a 70% (21/30) level of agreement with the affirmative evaluation statements. The results from the 2 instruments indicated a fair level of user satisfaction and a strong positive association as shown by the Pearson correlation value of .623 (P<.01). CONCLUSIONS A high-fidelity prototype was used to give the users experience with a product they would likely use in their work. Group testing was done because of scarcity of resources such as costs and time involved especially in low-income countries. If embraced, this approach could help assess user needs of the diverse user groups. With proper preparation and the right infrastructure at an affordable cost, usability testing could lead to the development of highly usable forms. The study thus makes recommendations on the practical guidelines for the implementation of the group testing approach particularly in low-resource settings during mobile form design.
- 30 May 2018
- Published by Springer Nature
- p. 463-466
Design Features for Usable Mobile Electronic Data Capturing Forms: The Form Developers’ Perspective
- 30 May 2018
- Published by Springer Nature
- p. 463-466
Design Features for Usable Mobile Electronic Data Capturing Forms: The Form Developers’ Perspective
- Open Access
- 15 June 2017
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 5 (2) , e14
Computerized Childbirth Monitoring Tools for Health Care Providers Managing Labor: A Scoping Review
Clinical informatics, decision support for health professionals, electronic health records, and ehealth infrastructures.
- 15 June 2017
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 5 (2) , e14
Open AccessComputerized Childbirth Monitoring Tools for Health Care Providers Managing Labor: A Scoping Review
Clinical informatics, decision support for health professionals, electronic health records, and ehealth infrastructures.