Jesus Benito-Ruiz
Research Subjects
Jesus Benito-Ruiz has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Laura Salvador-Miranda
Antiaging Group Barcelona, Barcelona, Spain
2 shared publicationsAlberto Redondo
Clínica Estética Córdoba, Córdoba, Spain
1 shared publicationAndre Cervantes
Patient Safety Committee, International Society of Aesthetic Plastic Surgery (ISAPS), Mount Royal, USA
1 shared publicationAngel Ferreres
1 shared publicationAnna Carreras
1 shared publicationEmma Ribas Rabert
Antiaging Group Barcelona. Clínica Tres Torres
1 shared publication
Latest Publications
- 8 April 2026
- Published by Springer Nature in Aesthetic Plastic Surgery
Postoperative Displacement of the Inframammary Fold in Breast Augmentation: A 12-Month Observational Study
The inframammary fold (IMF) plays a central role in breast augmentation surgery, yet its long-term positional stability following implant placement remains insufficiently characterized. Accurate prediction of IMF location is essential for aesthetic outcomes, particularly when selecting surgical approaches or implant types. A retrospective observational study was conducted on 156 breasts (78 patients) who underwent augmentation between 2018 and 2022, with a minimum follow-up of 12 months. Pre- and postoperative measurements were obtained using 3D imaging in arm-adducted position. Variables included SN-Ni, Ni-Ni, Ni-IMF, SN-Nimid, Ni-IMFmid, and SN-IMFmid. Patients were stratified by implant shape (anatomic vs. round), placement plane (submuscular, subfascial, dual plane II), and incision type. Statistical analyses were performed to evaluate IMF displacement and associated factors. The IMF was displaced by more than 10 mm from the planned position in 53.8% of cases. Anatomic implants demonstrated slightly less fold displacement than round implants (3 ± 14.7 mm vs. 8.1 ± 14 mm), although this was not statistically significant. Submuscular placement significantly increased lower pole expansion and IMF descent compared to subfascial placement (p < 0.05). There was no significant difference in fold stability based on incision type, including inframammary incisions where reinforcement sutures were used. Caudal displacement of the IMF is common following breast augmentation. Submuscular placement contributes significantly to this effect. Anatomic implants may offer improved fold stability. Preoperative planning using the implant radius from the sternal midline is reliable. IMF reinforcement appears non-essential but warrants further study. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
- 8 April 2026
- Published by Springer Nature in Aesthetic Plastic Surgery
Postoperative Displacement of the Inframammary Fold in Breast Augmentation: A 12-Month Observational Study
The inframammary fold (IMF) plays a central role in breast augmentation surgery, yet its long-term positional stability following implant placement remains insufficiently characterized. Accurate prediction of IMF location is essential for aesthetic outcomes, particularly when selecting surgical approaches or implant types. A retrospective observational study was conducted on 156 breasts (78 patients) who underwent augmentation between 2018 and 2022, with a minimum follow-up of 12 months. Pre- and postoperative measurements were obtained using 3D imaging in arm-adducted position. Variables included SN-Ni, Ni-Ni, Ni-IMF, SN-Nimid, Ni-IMFmid, and SN-IMFmid. Patients were stratified by implant shape (anatomic vs. round), placement plane (submuscular, subfascial, dual plane II), and incision type. Statistical analyses were performed to evaluate IMF displacement and associated factors. The IMF was displaced by more than 10 mm from the planned position in 53.8% of cases. Anatomic implants demonstrated slightly less fold displacement than round implants (3 ± 14.7 mm vs. 8.1 ± 14 mm), although this was not statistically significant. Submuscular placement significantly increased lower pole expansion and IMF descent compared to subfascial placement (p < 0.05). There was no significant difference in fold stability based on incision type, including inframammary incisions where reinforcement sutures were used. Caudal displacement of the IMF is common following breast augmentation. Submuscular placement contributes significantly to this effect. Anatomic implants may offer improved fold stability. Preoperative planning using the implant radius from the sternal midline is reliable. IMF reinforcement appears non-essential but warrants further study. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
- 7 November 2025
- Published by Springer Nature in Aesthetic Plastic Surgery
- Vol. 49 (24) , 6831-6837
ISAPS Patient Safety Update: Deep Venous: Thrombosis and Pulmonary Embolism: Stratification and Prophylaxis in Aesthetic Surgery
- 7 November 2025
- Published by Springer Nature in Aesthetic Plastic Surgery
- Vol. 49 (24) , 6831-6837
ISAPS Patient Safety Update: Deep Venous: Thrombosis and Pulmonary Embolism: Stratification and Prophylaxis in Aesthetic Surgery
- Open Access
- 16 June 2025
- Published by Oxford University Press (OUP) in Aesthetic Surgery Journal Open Forum
- Vol. 7
Argon Plasma-Assisted Liposuction (APAL) for Arm Contouring: Safety, Efficacy and Skin Tightening Outcomes
Background: Brachioplasty remains the gold standard for addressing excess skin on the arms. However, due to visible scarring and potential complications, new technologies have been explored to enhance skin tightening in combination with liposuction. Objectives: To evaluate the safety and efficacy of Argon plasma-assisted liposuction (APAL) for upper-arm contouring by quantifying changes in ptosis reduction, arm diameter, and skin elasticity. Methods: Fifteen patients (30 arms) were included in the study. All patients underwent power-assisted liposuction combined with Argon plasma at 50 W for 3 minutes per arm. Follow-ups were conducted at 10, 30, and 180 days post-procedure. Cutaneous temperature was measured before treatment and at 1 and 5 minutes after Argon plasma application. The variables assessed at the maximal point of convexity of the abducted arm included thickness (measured via ultrasound), ptosis, diameter (measured using a 3D camera), and elasticity (measured with a Cutometer). Patient satisfaction was evaluated using the ARM-Q test. Results: Compared to preoperative levels, there was a significant reduction in all parameters (ptosis, diameter, thickness, and skin elasticity) at each follow-up point. Results stabilized from day 30 onward. By the end of the study, the mean reduction was 29% for ptosis, 15% for diameter, and 42.7% for thickness. Patient satisfaction (ARM-Q) was notably high, with an average increase from 1.6 to 3 (85%). No major complications were observed, and skin heating remained within a safe threshold. Conclusions: Argon Plasma-assisted liposuction may be a safe and effective technique for upper-arm contouring, particularly in patients with mild to moderate skin laxity.
- 16 June 2025
- Published by Oxford University Press (OUP) in Aesthetic Surgery Journal Open Forum
- Vol. 7
Open AccessArgon Plasma-Assisted Liposuction (APAL) for Arm Contouring: Safety, Efficacy and Skin Tightening Outcomes
Background: Brachioplasty remains the gold standard for addressing excess skin on the arms. However, due to visible scarring and potential complications, new technologies have been explored to enhance skin tightening in combination with liposuction. Objectives: To evaluate the safety and efficacy of Argon plasma-assisted liposuction (APAL) for upper-arm contouring by quantifying changes in ptosis reduction, arm diameter, and skin elasticity. Methods: Fifteen patients (30 arms) were included in the study. All patients underwent power-assisted liposuction combined with Argon plasma at 50 W for 3 minutes per arm. Follow-ups were conducted at 10, 30, and 180 days post-procedure. Cutaneous temperature was measured before treatment and at 1 and 5 minutes after Argon plasma application. The variables assessed at the maximal point of convexity of the abducted arm included thickness (measured via ultrasound), ptosis, diameter (measured using a 3D camera), and elasticity (measured with a Cutometer). Patient satisfaction was evaluated using the ARM-Q test. Results: Compared to preoperative levels, there was a significant reduction in all parameters (ptosis, diameter, thickness, and skin elasticity) at each follow-up point. Results stabilized from day 30 onward. By the end of the study, the mean reduction was 29% for ptosis, 15% for diameter, and 42.7% for thickness. Patient satisfaction (ARM-Q) was notably high, with an average increase from 1.6 to 3 (85%). No major complications were observed, and skin heating remained within a safe threshold. Conclusions: Argon Plasma-assisted liposuction may be a safe and effective technique for upper-arm contouring, particularly in patients with mild to moderate skin laxity.
- 23 July 2024
- Published by Springer Nature in Aesthetic Plastic Surgery
- Vol. 49 (1) , 224-233
Breast Implant Removal-Only: The Role of Targeted Compression
Background The number of women seeking explantation of their breast implants has increased in recent years. Anxiety due to potential health problems has been one of the major catalysts. Mastopexy with or without autoaugmentation and fat grafting are the main techniques used in breast implant removal surgery. Objectives To analyse the aesthetic and satisfactory outcomes after simple breast implant removal assisted by targeted compression. Methods Twenty-eight patients were included in the series. Targeted compression of the breast after implant removal was performed during the 1st month. A satisfaction survey using a Likert scale was used before and after the final visit. The patients were followed up for 1 year. Results The mean age of the patients was 41 years old, and the mean time between implantation and removal was 10 years. Subjective reasons for removal (46.4% of the patients) were more frequent in women with less time since implantation (5 years) versus 15 years for implant-related problems. A total of 57.14% of the women were satisfied with the aesthetic result, and 42.86% were very satisfied. Only 17.8% of the total would consider an aesthetic refinement. Conclusions Simple breast implant removal yields good aesthetic outcomes, and patients are satisfied with the results. Good management of compression of the breast and close follow-up to treat any collection in the pocket provides good adhesion and allows for effective management of the process of deflation and setting of the breast mound. Level of Evidence IV This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266
- 23 July 2024
- Published by Springer Nature in Aesthetic Plastic Surgery
- Vol. 49 (1) , 224-233
Breast Implant Removal-Only: The Role of Targeted Compression
Background The number of women seeking explantation of their breast implants has increased in recent years. Anxiety due to potential health problems has been one of the major catalysts. Mastopexy with or without autoaugmentation and fat grafting are the main techniques used in breast implant removal surgery. Objectives To analyse the aesthetic and satisfactory outcomes after simple breast implant removal assisted by targeted compression. Methods Twenty-eight patients were included in the series. Targeted compression of the breast after implant removal was performed during the 1st month. A satisfaction survey using a Likert scale was used before and after the final visit. The patients were followed up for 1 year. Results The mean age of the patients was 41 years old, and the mean time between implantation and removal was 10 years. Subjective reasons for removal (46.4% of the patients) were more frequent in women with less time since implantation (5 years) versus 15 years for implant-related problems. A total of 57.14% of the women were satisfied with the aesthetic result, and 42.86% were very satisfied. Only 17.8% of the total would consider an aesthetic refinement. Conclusions Simple breast implant removal yields good aesthetic outcomes, and patients are satisfied with the results. Good management of compression of the breast and close follow-up to treat any collection in the pocket provides good adhesion and allows for effective management of the process of deflation and setting of the breast mound. Level of Evidence IV This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266
- 22 August 2023
- Published by Springer Nature in Aesthetic Plastic Surgery
- Vol. 48 (5) , 943-945
Invited Discussion: Use of Radiofrequency Assisted Liposuction (Bodytite) for Upper Arms Lifting
- 22 August 2023
- Published by Springer Nature in Aesthetic Plastic Surgery
- Vol. 48 (5) , 943-945
Invited Discussion: Use of Radiofrequency Assisted Liposuction (Bodytite) for Upper Arms Lifting
- 12 April 2023
- Published by Oxford University Press (OUP) in Aesthetic Surgery Journal
- Vol. 43 (10) , NP751-NP762
The Position of the Nipple-Areola Complex in Breast Augmentation
Background: There is some controversy regarding whether the nipple-areola complex (NAC) is elevated, remains stable, or is lowered in breast augmentation. There is a general belief that one can modulate its position depending on the implant chosen. In addition, many preoperative markings include elevating the arms to predict the final position of the NAC. Objectives: The aim of this study was to investigate changes in the position of the NAC and determine whether the postoperative position of the NAC can be predicted preoperatively by elevating the arms. Methods: The study included 45 patients. A 3-dimensional scan was performed to take basal (preoperative) and 12-month measurements with the patient's arms in abduction and elevated over the head. The distances measured were the sternal notch-nipple (SN-Ni), nipple-nipple (Ni-Ni), and nipple-inframammary fold (Ni-IMF) distances. Results: With arms abducted, the SN-Ni distance increased by 6% when measured linearly, 8.5% when measured on the skin surface, and 1% to 2% when measured on the sternal line. The Ni-Ni distance increased by 9% (linear) and 15% (over the surface). The Ni-IMF increased by 44%. With arms adducted, the SN-Ni distance increased by 9% (linear), 12% (on the skin surface), and 0.5% at the sternal midline projection. The Ni-Ni distance increased 11% (linear) and 19% (on the surface). The Ni-IMF distance increased by 53%. The postoperative position of the NAC with the arms abducted increased by 17% compared with the preoperative position in adduction. Conclusions: Implants do not elevate the NAC; its position remains nearly unaltered. The SN-Ni distance was increased in 90% of the patients. Lifting the arms for preoperative markings does not help to predict the postoperative position of the NAC. Level of Evidence: 4:
- 12 April 2023
- Published by Oxford University Press (OUP) in Aesthetic Surgery Journal
- Vol. 43 (10) , NP751-NP762
The Position of the Nipple-Areola Complex in Breast Augmentation
Background: There is some controversy regarding whether the nipple-areola complex (NAC) is elevated, remains stable, or is lowered in breast augmentation. There is a general belief that one can modulate its position depending on the implant chosen. In addition, many preoperative markings include elevating the arms to predict the final position of the NAC. Objectives: The aim of this study was to investigate changes in the position of the NAC and determine whether the postoperative position of the NAC can be predicted preoperatively by elevating the arms. Methods: The study included 45 patients. A 3-dimensional scan was performed to take basal (preoperative) and 12-month measurements with the patient's arms in abduction and elevated over the head. The distances measured were the sternal notch-nipple (SN-Ni), nipple-nipple (Ni-Ni), and nipple-inframammary fold (Ni-IMF) distances. Results: With arms abducted, the SN-Ni distance increased by 6% when measured linearly, 8.5% when measured on the skin surface, and 1% to 2% when measured on the sternal line. The Ni-Ni distance increased by 9% (linear) and 15% (over the surface). The Ni-IMF increased by 44%. With arms adducted, the SN-Ni distance increased by 9% (linear), 12% (on the skin surface), and 0.5% at the sternal midline projection. The Ni-Ni distance increased 11% (linear) and 19% (on the surface). The Ni-IMF distance increased by 53%. The postoperative position of the NAC with the arms abducted increased by 17% compared with the preoperative position in adduction. Conclusions: Implants do not elevate the NAC; its position remains nearly unaltered. The SN-Ni distance was increased in 90% of the patients. Lifting the arms for preoperative markings does not help to predict the postoperative position of the NAC. Level of Evidence: 4:
- 17 January 2023
- Published by Springer Nature in Aesthetic Plastic Surgery
- Vol. 47 (2) , 714-716
Invited Discussion: Rhinofiller—Fat Grafting (Surgical) Versus Hyaluronic Acid (Nonsurgical)
- 17 January 2023
- Published by Springer Nature in Aesthetic Plastic Surgery
- Vol. 47 (2) , 714-716
Invited Discussion: Rhinofiller—Fat Grafting (Surgical) Versus Hyaluronic Acid (Nonsurgical)
- 18 March 2022
- Published by Springer Nature in Aesthetic Plastic Surgery
- Vol. 46 (6) , 2665-2668
Invited Discussion: Endoscope-Assisted Minimally Invasive Surgery for the Treatment of Glandular Gynecomastia
- 18 March 2022
- Published by Springer Nature in Aesthetic Plastic Surgery
- Vol. 46 (6) , 2665-2668
Invited Discussion: Endoscope-Assisted Minimally Invasive Surgery for the Treatment of Glandular Gynecomastia
- 8 February 2022
- Published by Springer Nature in Aesthetic Plastic Surgery
- Vol. 46 (2) , 920-922
Invited Discussion on: Effect of Diameter and Fenestration Area of the Liposuction Cannula in the Viability of the Adipocytes
- 8 February 2022
- Published by Springer Nature in Aesthetic Plastic Surgery
- Vol. 46 (2) , 920-922
Invited Discussion on: Effect of Diameter and Fenestration Area of the Liposuction Cannula in the Viability of the Adipocytes
- 4 February 2021
- Published by Springer Nature in Aesthetic Plastic Surgery
- Vol. 45 (3) , 893-894
Invited Discussion on: A Modified Superior Pedicle Mastopexy Technique with an Inferolateral-Based Autoaugmentation Flap
- 4 February 2021
- Published by Springer Nature in Aesthetic Plastic Surgery
- Vol. 45 (3) , 893-894
Invited Discussion on: A Modified Superior Pedicle Mastopexy Technique with an Inferolateral-Based Autoaugmentation Flap