Rachana Kumar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Rachana Kumar has a total of 95 co-authors. Here are the top co-authors by number of shared publications:
- Pramod Kumar
Indian Institute of Information Technology Allahabad
18 shared publications Samya Naqvi
Natl Measurement Inst India, Natl Phys Lab, CSIR, Photovolta Metrol Grp,Adv Mat & Devices Metrol Di, Dr KS Krishnan Marg, New Delhi 110012, India
14 shared publications- Mahesh Kumar
Academy of Scientific and Innovative Research
8 shared publications Mehak Ahuja
6 shared publications- Kavindra Kandpal
Department of Electronics and Communication Engineering, Indian Institute of Information Technology, Allahabad, India
5 shared publications Komal Bhardwaj
5 shared publications
Latest Publications
- Open Access
- 2 November 2026
- Published by Royal Society of Chemistry (RSC) in Materials Advances
- Vol. 7 (21) , 10630-10638
Measurement-mode-controlled conductive filament growth enabling full-state programmability in organic multilevel memristors
Inter-quantized-state switching among discrete conductance levels (L0 → L1 → L2 → L3) demonstrates multilevel memory functionality, enabling reversible transitions between stable states for high-density data storage and multilevel computing.
- 2 November 2026
- Published by Royal Society of Chemistry (RSC) in Materials Advances
- Vol. 7 (21) , 10630-10638
Open AccessMeasurement-mode-controlled conductive filament growth enabling full-state programmability in organic multilevel memristors
Inter-quantized-state switching among discrete conductance levels (L0 → L1 → L2 → L3) demonstrates multilevel memory functionality, enabling reversible transitions between stable states for high-density data storage and multilevel computing.
- Open Access
- 2 May 2026
- Published by Springer Nature in Journal of Materials Science: Materials in Engineering
- Vol. 21 (1)
Creatinine detection in artificial urine using perylenediimide probe single split resonator device
Quick, cost effective, sensitive, reusable biosensors are the requirement of current time to detect biomarkers at low levels for early diagnosis of diseases. Metamaterial biosensors have shown their potential for quantitative detection of biomolecules with minimal sample size and processing requirement. In the current work, single split resonator (SSR) biosensor is developed for the detection of creatinine biomarker in artificial urine (AU) using perylenediimide probe molecule. Creatinine is critical biomarker to be diagnosed both at high and low levels. The reported SSR device can detect creatinine in the range of 0.01–750 µM in artificial urine with limit of detection of 0.015 µM. The device shows high sensitivity and Figure-of-merit (FoM) of ~ 73 MHz/DCU and ~ 167 respectively using PDI as probe molecule in artificial urine. To the best of our knowledge, this is the first study conducted for quantitative detection of creatinine in artificial urine using probe molecule using SSR device. The absorption and fluorescence spectroscopy studies have also been performed and compared for sensitivity. SSR based biosensor with high sensitivity and reusability for detection of low to high concentration of creatinine in artificial urine using PDI as probe molecule is demonstrated as potential point of use biomedical device.
- 2 May 2026
- Published by Springer Nature in Journal of Materials Science: Materials in Engineering
- Vol. 21 (1)
Open AccessCreatinine detection in artificial urine using perylenediimide probe single split resonator device
Quick, cost effective, sensitive, reusable biosensors are the requirement of current time to detect biomarkers at low levels for early diagnosis of diseases. Metamaterial biosensors have shown their potential for quantitative detection of biomolecules with minimal sample size and processing requirement. In the current work, single split resonator (SSR) biosensor is developed for the detection of creatinine biomarker in artificial urine (AU) using perylenediimide probe molecule. Creatinine is critical biomarker to be diagnosed both at high and low levels. The reported SSR device can detect creatinine in the range of 0.01–750 µM in artificial urine with limit of detection of 0.015 µM. The device shows high sensitivity and Figure-of-merit (FoM) of ~ 73 MHz/DCU and ~ 167 respectively using PDI as probe molecule in artificial urine. To the best of our knowledge, this is the first study conducted for quantitative detection of creatinine in artificial urine using probe molecule using SSR device. The absorption and fluorescence spectroscopy studies have also been performed and compared for sensitivity. SSR based biosensor with high sensitivity and reusability for detection of low to high concentration of creatinine in artificial urine using PDI as probe molecule is demonstrated as potential point of use biomedical device.
- Open Access
- 2 March 2026
- Published by Elsevier in SSRN Electronic Journal
Selective detection of lead in water and food matrix using band gap-controlled graphene oxide by optical and electrochemical methods
In this work, graphene oxides (GO) with controlled electronic band gap have been synthesized through a tailored mild-oxidation strategy to establish the structure-property relationship for Pb²⁺ ion recognition. The GO variants, exhibiting band gaps of 1.8, 1.5, and 1.35 eV, are thoroughly examined using absorption spectroscopy and electrochemical methods to uncover their interaction behavior with metal ions in water and food matrix. mGO-1 with band gap of 1.5 eV delivered selective detection of lead metal ion, achieving a remarkably low detection limit of 0.008 nM. The applicability of mGO-1 for lead metal detection is also explored in food matrix in turmeric and compared with the conventional method of analysis. The findings provide clear evidence that engineering the band gap of GO can strategically enhance its sensing capability, offering a powerful platform for lead detection in environmental and food matrices.
- 2 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessSelective detection of lead in water and food matrix using band gap-controlled graphene oxide by optical and electrochemical methods
In this work, graphene oxides (GO) with controlled electronic band gap have been synthesized through a tailored mild-oxidation strategy to establish the structure-property relationship for Pb²⁺ ion recognition. The GO variants, exhibiting band gaps of 1.8, 1.5, and 1.35 eV, are thoroughly examined using absorption spectroscopy and electrochemical methods to uncover their interaction behavior with metal ions in water and food matrix. mGO-1 with band gap of 1.5 eV delivered selective detection of lead metal ion, achieving a remarkably low detection limit of 0.008 nM. The applicability of mGO-1 for lead metal detection is also explored in food matrix in turmeric and compared with the conventional method of analysis. The findings provide clear evidence that engineering the band gap of GO can strategically enhance its sensing capability, offering a powerful platform for lead detection in environmental and food matrices.
- 4 August 2024
- Published by Elsevier in Journal of Molecular Structure
- Vol. 1319
High electrical conductivity induced by charge transfer interactions in naphthalenediimide derivatives
- 4 August 2024
- Published by Elsevier in Journal of Molecular Structure
- Vol. 1319
High electrical conductivity induced by charge transfer interactions in naphthalenediimide derivatives
- Open Access
- 25 May 2024
- Published by Elsevier in Carbon Trends
- Vol. 15
Effect of band gap of graphene oxide on interaction with bovine serum albumin: Correlation of band gap with sensitivity
- 25 May 2024
- Published by Elsevier in Carbon Trends
- Vol. 15
Open AccessEffect of band gap of graphene oxide on interaction with bovine serum albumin: Correlation of band gap with sensitivity
- 24 December 2023
- Published by Elsevier in Journal of Molecular Structure
- Vol. 1301
Symmetry breaking charge transfer behaviour in D-A-D triad system by selective excitation
- 24 December 2023
- Published by Elsevier in Journal of Molecular Structure
- Vol. 1301
Symmetry breaking charge transfer behaviour in D-A-D triad system by selective excitation
- 25 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (23) , 28579-28586
Single Split Resonance Sensor Device for Detection of Bovine Serum Albumin Using Water Soluble Perylenediimide as Probe
Perylenediimides (PDI) are organic n-type semiconductor molecules with special photophysical and device properties. These molecules are underutilized in biomedical applications. In the current work, a water-soluble PDI substituted with ethylenediamine at N-imide position (PDI-EDAQ) is used as a probe molecule and studied for its interaction with bovine serum albumin (BSA) quantitatively. Single split resonator (SSR) devices are fabricated and studied for interaction in the range of 300 MHz to 1 GHz with high accuracy and resolution for quantitative identification of BSA using PDI as probe. SSR device shows high sensitivity, Q-factor and figure of merit (FoM) with sequential shift in resonance frequency for increasing concentration of BSA on using PDI as probe. Without PDI, no shift was observed on increasing the amount of BSA. The mechanism of interaction between PDI and BSA is interpreted using absorption, fluorescence and transient absorption spectroscopy (TAS) studies. Charge separated species appears at 775 nm (1.6 eV) with lifetime of 220 fs after 2.3 ps delay of excitation in TAS spectra due to formation of donor-acceptor charge transfer complex between BSA and PDI and response in SSR devices are obtained for this C-T complex. PDI probe-based SSR devices are envisaged as potential electronic diagnosis devices with high sensitivity.
- 25 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (23) , 28579-28586
Single Split Resonance Sensor Device for Detection of Bovine Serum Albumin Using Water Soluble Perylenediimide as Probe
Perylenediimides (PDI) are organic n-type semiconductor molecules with special photophysical and device properties. These molecules are underutilized in biomedical applications. In the current work, a water-soluble PDI substituted with ethylenediamine at N-imide position (PDI-EDAQ) is used as a probe molecule and studied for its interaction with bovine serum albumin (BSA) quantitatively. Single split resonator (SSR) devices are fabricated and studied for interaction in the range of 300 MHz to 1 GHz with high accuracy and resolution for quantitative identification of BSA using PDI as probe. SSR device shows high sensitivity, Q-factor and figure of merit (FoM) with sequential shift in resonance frequency for increasing concentration of BSA on using PDI as probe. Without PDI, no shift was observed on increasing the amount of BSA. The mechanism of interaction between PDI and BSA is interpreted using absorption, fluorescence and transient absorption spectroscopy (TAS) studies. Charge separated species appears at 775 nm (1.6 eV) with lifetime of 220 fs after 2.3 ps delay of excitation in TAS spectra due to formation of donor-acceptor charge transfer complex between BSA and PDI and response in SSR devices are obtained for this C-T complex. PDI probe-based SSR devices are envisaged as potential electronic diagnosis devices with high sensitivity.
- 24 August 2023
- Published by Springer Nature
- p. 651-678
Indian Reference Materials for Calibration of Sophisticated Instruments
- 24 August 2023
- Published by Springer Nature
- p. 651-678
Indian Reference Materials for Calibration of Sophisticated Instruments
- Open Access
- 12 December 2022
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 12 (55) , 35977-35988
Covalently linked benzothiadiazole-fullerene adducts for organic optoelectronic devices: synthesis and characterization
Covalently-bonded acceptor and donor units: Tuning the properties of benzothiadiazole-based fullerene moleculesviadifferent chemistries.
- 12 December 2022
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 12 (55) , 35977-35988
Open AccessCovalently linked benzothiadiazole-fullerene adducts for organic optoelectronic devices: synthesis and characterization
Covalently-bonded acceptor and donor units: Tuning the properties of benzothiadiazole-based fullerene moleculesviadifferent chemistries.