Philipp Hoess
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Philipp Hoess has a total of 146 co-authors. Here are the top co-authors by number of shared publications:
- Jonas Ries
Max Perutz Labs, University of Vienna, Dr. Bohr-Gasse 9, 1030, Vienna, Austria
26 shared publications - Jan Ellenberg
Cell Biology and Biophysics Unit, European Molecular Biology Laboratory, Heidelberg, Germany
12 shared publications - Ulf Matti
Cell Biology and Biophysics Unit, European Molecular Biology Laboratory (EMBL), Heidelberg, Germany
10 shared publications - Markus Mund
Cell Biology and Biophysics Unit, European Molecular Biology Laboratory (EMBL), Heidelberg, Germany
9 shared publications - Bianca Nijmeijer
EMBL, Cell Biology and Biophysics, Heidelberg, Germany
7 shared publications - Yiming Li
Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen, China
7 shared publications
Latest Publications
- Top Cited Papers
- 10 March 2023
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 379 (6636) , 1010-1015
Direct observation of motor protein stepping in living cells using MINFLUX
Dynamic measurements of molecular machines can provide invaluable insights into their mechanism, but these measurements have been challenging in living cells. Here, we developed live-cell tracking of single fluorophores with nanometer spatial and millisecond temporal resolution in two and three dimensions using the recently introduced super-resolution technique MINFLUX. Using this approach, we resolved the precise stepping motion of the motor protein kinesin-1 as it walked on microtubules in living cells. Nanoscopic tracking of motors walking on the microtubules of fixed cells also enabled us to resolve the architecture of the microtubule cytoskeleton with protofilament resolution.
- 10 March 2023
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 379 (6636) , 1010-1015
Top Cited PapersDirect observation of motor protein stepping in living cells using MINFLUX
Dynamic measurements of molecular machines can provide invaluable insights into their mechanism, but these measurements have been challenging in living cells. Here, we developed live-cell tracking of single fluorophores with nanometer spatial and millisecond temporal resolution in two and three dimensions using the recently introduced super-resolution technique MINFLUX. Using this approach, we resolved the precise stepping motion of the motor protein kinesin-1 as it walked on microtubules in living cells. Nanoscopic tracking of motors walking on the microtubules of fixed cells also enabled us to resolve the architecture of the microtubule cytoskeleton with protofilament resolution.
- 15 December 2022
- Published by Springer Nature in Nature Methods
- Vol. 20 (1) , 52-54
Reply to: Assessment of 3D MINFLUX data for quantitative structural biology in cells
- 15 December 2022
- Published by Springer Nature in Nature Methods
- Vol. 20 (1) , 52-54
Reply to: Assessment of 3D MINFLUX data for quantitative structural biology in cells
- Open Access
- 15 December 2022
- Published by Springer Nature in Nature Methods
- Vol. 20 (1) , 139-148
Maximum-likelihood model fitting for quantitative analysis of SMLM data
Quantitative data analysis is important for any single-molecule localization microscopy (SMLM) workflow to extract biological insights from the coordinates of the single fluorophores. However, current approaches are restricted to simple geometries or require identical structures. Here, we present LocMoFit (Localization Model Fit), an open-source framework to fit an arbitrary model to localization coordinates. It extracts meaningful parameters from individual structures and can select the most suitable model. In addition to analyzing complex, heterogeneous and dynamic structures for in situ structural biology, we demonstrate how LocMoFit can assemble multi-protein distribution maps of six nuclear pore components, calculate single-particle averages without any assumption about geometry or symmetry, and perform a time-resolved reconstruction of the highly dynamic endocytic process from static snapshots. We provide extensive simulation and visualization routines to validate the robustness of LocMoFit and tutorials to enable any user to increase the information content they can extract from their SMLM data.
- 15 December 2022
- Published by Springer Nature in Nature Methods
- Vol. 20 (1) , 139-148
Open AccessMaximum-likelihood model fitting for quantitative analysis of SMLM data
Quantitative data analysis is important for any single-molecule localization microscopy (SMLM) workflow to extract biological insights from the coordinates of the single fluorophores. However, current approaches are restricted to simple geometries or require identical structures. Here, we present LocMoFit (Localization Model Fit), an open-source framework to fit an arbitrary model to localization coordinates. It extracts meaningful parameters from individual structures and can select the most suitable model. In addition to analyzing complex, heterogeneous and dynamic structures for in situ structural biology, we demonstrate how LocMoFit can assemble multi-protein distribution maps of six nuclear pore components, calculate single-particle averages without any assumption about geometry or symmetry, and perform a time-resolved reconstruction of the highly dynamic endocytic process from static snapshots. We provide extensive simulation and visualization routines to validate the robustness of LocMoFit and tutorials to enable any user to increase the information content they can extract from their SMLM data.
- Open Access
Direct observation of motor protein stepping in living cells using MINFLUX
Dynamic measurements of molecular machines can provide invaluable insights into their mechanism, but have been challenging in living cells. Here, we developed live-cell tracking of single fluorophores with nanometer spatial and millisecond temporal resolution in 2D and 3D using the recently introduced super-resolution technique MINFLUX. This allowed us to resolve the precise stepping motion of the motor protein kinesin-1 as it walks on microtubules in living cells. In addition, nanoscopic tracking of motors on microtubule of fixed cells enabled us to resolve their spatial organization with protofilament resolution. Our approach will enable future in vivo studies of motor protein kinetics in complex environments and super-resolution mapping of dense microtubule arrays, and pave the way towards monitoring functional conformational changes of protein machines at high spatiotemporal resolution in living systems.
Open AccessDirect observation of motor protein stepping in living cells using MINFLUX
Dynamic measurements of molecular machines can provide invaluable insights into their mechanism, but have been challenging in living cells. Here, we developed live-cell tracking of single fluorophores with nanometer spatial and millisecond temporal resolution in 2D and 3D using the recently introduced super-resolution technique MINFLUX. This allowed us to resolve the precise stepping motion of the motor protein kinesin-1 as it walks on microtubules in living cells. In addition, nanoscopic tracking of motors on microtubule of fixed cells enabled us to resolve their spatial organization with protofilament resolution. Our approach will enable future in vivo studies of motor protein kinetics in complex environments and super-resolution mapping of dense microtubule arrays, and pave the way towards monitoring functional conformational changes of protein machines at high spatiotemporal resolution in living systems.
- Open Access
MicroFPGA: an affordable FPGA platform for microscope control
Modern microscopy relies increasingly on microscope automation to improve throughput, ensure reproducibility or observe rare events. Automation requires in particular computer control of the important elements of the microscope. Furthermore, optical elements that are usually fixed or manually movable can be placed on electronically-controllable elements. In most cases, a central electronics board is necessary to generate the control signals they require and to communicate with the computer. Fur such tasks, Arduino microcontrollers are widely used due to their low cost and programming entry barrier. However, they are limiting in their performance for applications that require high-speed or multiple parallel processes. Field programmable gate arrays (FPGA) are the perfect technology for high-speed microscope control, as they are capable of processing signals in parallel and with high temporal precision. While plummeting price made the technology available to consumers, a major hurdle remains the complex languages used to configure them. In this work, we used an affordable FPGA, delivered with an open-source and friendly-to-use programming language, to create a versatile microscope control platform called MicroFPGA. It is capable of synchronously triggering cameras and multiple lasers following complex patterns, as well as generating various signals used to control microscope elements such as filter wheels, servomotor stages, flip-mirrors, laser power or acoustooptic modulators. MicroFPGA is open-source and we provide online Micro-Manager, Java, Python and LabVIEW libraries, together with blueprints and tutorials.
Open AccessMicroFPGA: an affordable FPGA platform for microscope control
Modern microscopy relies increasingly on microscope automation to improve throughput, ensure reproducibility or observe rare events. Automation requires in particular computer control of the important elements of the microscope. Furthermore, optical elements that are usually fixed or manually movable can be placed on electronically-controllable elements. In most cases, a central electronics board is necessary to generate the control signals they require and to communicate with the computer. Fur such tasks, Arduino microcontrollers are widely used due to their low cost and programming entry barrier. However, they are limiting in their performance for applications that require high-speed or multiple parallel processes. Field programmable gate arrays (FPGA) are the perfect technology for high-speed microscope control, as they are capable of processing signals in parallel and with high temporal precision. While plummeting price made the technology available to consumers, a major hurdle remains the complex languages used to configure them. In this work, we used an affordable FPGA, delivered with an open-source and friendly-to-use programming language, to create a versatile microscope control platform called MicroFPGA. It is capable of synchronously triggering cameras and multiple lasers following complex patterns, as well as generating various signals used to control microscope elements such as filter wheels, servomotor stages, flip-mirrors, laser power or acoustooptic modulators. MicroFPGA is open-source and we provide online Micro-Manager, Java, Python and LabVIEW libraries, together with blueprints and tutorials.
- Open Access
Assessment of 3D MINFLUX data for quantitative structural biology in cells revisited
Prakash and Curd provide a re-analysis 1 of individual datasets taken from our report 2 demonstrating MINFLUX 3D imaging in cells. Their evaluation confirms the unique localization precision provided by MINFLUX 2,3 featuring a standard deviation of σ = 1-3 nm. We appreciate their confirmation and also welcome the opportunity to clarify their remaining points. The hitherto almost unconceivable 3D localization precision attained by MINFLUX is likely to hold the key to an all-optical dynamical structural biology.
Open AccessAssessment of 3D MINFLUX data for quantitative structural biology in cells revisited
Prakash and Curd provide a re-analysis 1 of individual datasets taken from our report 2 demonstrating MINFLUX 3D imaging in cells. Their evaluation confirms the unique localization precision provided by MINFLUX 2,3 featuring a standard deviation of σ = 1-3 nm. We appreciate their confirmation and also welcome the opportunity to clarify their remaining points. The hitherto almost unconceivable 3D localization precision attained by MINFLUX is likely to hold the key to an all-optical dynamical structural biology.
- 21 September 2021
- Published by Springer Nature in Nature Methods
- Vol. 18 (11) , 1410
Publisher Correction: Deep learning enables fast and dense single-molecule localization with high accuracy
- 21 September 2021
- Published by Springer Nature in Nature Methods
- Vol. 18 (11) , 1410
Publisher Correction: Deep learning enables fast and dense single-molecule localization with high accuracy
- Top Cited Papers
- 3 September 2021
- Published by Springer Nature in Nature Methods
- Vol. 18 (9) , 1082-1090
Deep learning enables fast and dense single-molecule localization with high accuracy
Single-molecule localization microscopy (SMLM) has had remarkable success in imaging cellular structures with nanometer resolution, but standard analysis algorithms require sparse emitters, which limits imaging speed and labeling density. Here, we overcome this major limitation using deep learning. We developed DECODE (deep context dependent), a computational tool that can localize single emitters at high density in three dimensions with highest accuracy for a large range of imaging modalities and conditions. In a public software benchmark competition, it outperformed all other fitters on 12 out of 12 datasets when comparing both detection accuracy and localization error, often by a substantial margin. DECODE allowed us to acquire fast dynamic live-cell SMLM data with reduced light exposure and to image microtubules at ultra-high labeling density. Packaged for simple installation and use, DECODE will enable many laboratories to reduce imaging times and increase localization density in SMLM.
- 3 September 2021
- Published by Springer Nature in Nature Methods
- Vol. 18 (9) , 1082-1090
Top Cited PapersDeep learning enables fast and dense single-molecule localization with high accuracy
Single-molecule localization microscopy (SMLM) has had remarkable success in imaging cellular structures with nanometer resolution, but standard analysis algorithms require sparse emitters, which limits imaging speed and labeling density. Here, we overcome this major limitation using deep learning. We developed DECODE (deep context dependent), a computational tool that can localize single emitters at high density in three dimensions with highest accuracy for a large range of imaging modalities and conditions. In a public software benchmark competition, it outperformed all other fitters on 12 out of 12 datasets when comparing both detection accuracy and localization error, often by a substantial margin. DECODE allowed us to acquire fast dynamic live-cell SMLM data with reduced light exposure and to image microtubules at ultra-high labeling density. Packaged for simple installation and use, DECODE will enable many laboratories to reduce imaging times and increase localization density in SMLM.
- Open Access
Maximum-likelihood model fitting for quantitative analysis of SMLM data
Quantitative analysis is an important part of any single-molecule localization microscopy (SMLM) data analysis workflow to extract biological insights from the coordinates of the single fluorophores, but current approaches are restricted to simple geometries or do not work on heterogenous structures. Here, we present LocMoFit ( Loc alization Mo del Fit ), an open-source framework to fit an arbitrary model directly to the localization coordinates in SMLM data. Using maximum likelihood estimation, this tool extracts the most likely parameters for a given model that best describe the data, and can select the most likely model from alternative models. We demonstrate the versatility of LocMoFit by measuring precise dimensions of the nuclear pore complex and microtubules. We also use LocMoFit to assemble static and dynamic multi-color protein density maps from thousands of snapshots. In case an underlying geometry cannot be postulated, LocMoFit can perform single-particle averaging of super-resolution structures without any assumption about geometry or symmetry. We provide extensive simulation and visualization routines to validate the robustness of LocMoFit and tutorials based on example data to enable any user to increase the information content they can extract from their SMLM data.
Open AccessMaximum-likelihood model fitting for quantitative analysis of SMLM data
Quantitative analysis is an important part of any single-molecule localization microscopy (SMLM) data analysis workflow to extract biological insights from the coordinates of the single fluorophores, but current approaches are restricted to simple geometries or do not work on heterogenous structures. Here, we present LocMoFit ( Loc alization Mo del Fit ), an open-source framework to fit an arbitrary model directly to the localization coordinates in SMLM data. Using maximum likelihood estimation, this tool extracts the most likely parameters for a given model that best describe the data, and can select the most likely model from alternative models. We demonstrate the versatility of LocMoFit by measuring precise dimensions of the nuclear pore complex and microtubules. We also use LocMoFit to assemble static and dynamic multi-color protein density maps from thousands of snapshots. In case an underlying geometry cannot be postulated, LocMoFit can perform single-particle averaging of super-resolution structures without any assumption about geometry or symmetry. We provide extensive simulation and visualization routines to validate the robustness of LocMoFit and tutorials based on example data to enable any user to increase the information content they can extract from their SMLM data.
- Open Access
Systematic Tuning of Rhodamine Spirocyclization for Super-Resolution Microscopy
Rhodamines are the most important class of fluorophores for applications in live-cell fluorescence microscopy. This is mainly because rhodamines exist in a dynamic equilibrium between a fluorescent zwitterion and a non-fluorescent but cell-permeable spirocyclic form. Different imaging applications require different positions of this dynamic equilibrium, which poses a challenge for the design of suitable probes. We describe here how the conversion of the ortho -carboxy moiety of a given rhodamine into substituted acyl benzenesulfonamides and alkylamides permits the systematic tuning of the equilibrium of spirocyclization with unprecedented accuracy and over a large range. This allows to transform the same rhodamine into either a highly fluorogenic and cell-permeable probe for live-cell stimulated emission depletion (STED) microscopy, or into a spontaneously blinking dye for single molecule localization microscopy (SMLM). We used this approach to generate differently colored probes optimized for different labeling systems and imaging applications.
Open AccessSystematic Tuning of Rhodamine Spirocyclization for Super-Resolution Microscopy
Rhodamines are the most important class of fluorophores for applications in live-cell fluorescence microscopy. This is mainly because rhodamines exist in a dynamic equilibrium between a fluorescent zwitterion and a non-fluorescent but cell-permeable spirocyclic form. Different imaging applications require different positions of this dynamic equilibrium, which poses a challenge for the design of suitable probes. We describe here how the conversion of the ortho -carboxy moiety of a given rhodamine into substituted acyl benzenesulfonamides and alkylamides permits the systematic tuning of the equilibrium of spirocyclization with unprecedented accuracy and over a large range. This allows to transform the same rhodamine into either a highly fluorogenic and cell-permeable probe for live-cell stimulated emission depletion (STED) microscopy, or into a spontaneously blinking dye for single molecule localization microscopy (SMLM). We used this approach to generate differently colored probes optimized for different labeling systems and imaging applications.