FLFrederic Lamare

Frederic Lamare

*This is an algorithmically generated author record based on publicly available information.

Frederic Lamare has a total of 239 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • PET respiratory motion correction: quo vadis?

    by F Lamare, A Bousse, K Thielemans, C Liu, T Merlin, H Fayad, D Visvikis

    Positron emission tomography (PET) respiratory motion correction has been a subject of great interest for the last twenty years, prompted mainly by the development of multimodality imaging devices such as PET/computed tomography (CT) and PET/magnetic resonance imaging (MRI). PET respiratory motion correction involves a number of steps including acquisition synchronization, motion estimation and finally motion correction. The synchronization steps include the use of different external device systems or data driven approaches which have been gaining ground over the last few years. Patient specific or generic motion models using the respiratory synchronized datasets can be subsequently derived and used for correction either in the image space or within the image reconstruction process. Similar overall approaches can be considered and have been proposed for both PET/CT and PET/MRI devices. Certain variations in the case of PET/MRI include the use of MRI specific sequences for the registration of respiratory motion information. The proposed review includes a comprehensive coverage of all these areas of development in field of PET respiratory motion for different multimodality imaging devices and approaches in terms of synchronization, estimation and subsequent motion correction. Finally, a section on perspectives including the potential clinical usage of these approaches is included.


  • Quantification of Hypoxia in Human Glioblastoma using PET with 18F-FMISO

    by Redha-Alla Abdo, Frédéric Lamare, Philippe Fernandez, M’hAmed Bentourkia

    Purpose This study aimed to investigate the results of compartmental modeling (CM) and spectral analysis (SA) generated with dynamic 18F-FMISO tumor images. Besides, the regular tissue-to-blood ratio (TBR) images were derived and compared with the dynamic models. Methods Nine subjects with glioblastoma underwent PET/CT imaging with the 18F-FMISO tracer. The protocol for PET imaging began with 15 min in dynamic mode and two 10-min duration static images at 120 min and 180 min post-injection. We used the two-tissue compartmental model for CM at the voxel basis, and we conducted SA to estimate the 18F-FMISO accumulation within each voxel. We also investigated the usual tumor-to-blood ratio (TBR) for comparison. Results The images of the tumor showed different patterns of hypoxia and necrosis as a function of PET scanning times, while CM and SA methods based on dynamic PET imaging equally located tumor hypoxia. The mean correlation of Ki images of all subjects between CM and SA was 0.63 ± 0.19 (0.24-0.86). CM produced less noisy Ki images than SA, and, in the contrary, SA produced accumulation component images more clear than with CM. CM-Ki and SA-Ki images were correlated with TBR images (r = 0.72 ± 0.20 and 0.56 ± 0.26, respectively). In the only subject having a continuously increasing tumor time-activity curve, the k3 image showed a high uptake in the necrosis region which was not apparent in TBR or Ki images. Conclusion Based on these results, the combination of CM and SA approaches was found more appropriate in generating voxel-based hypoxia images.


  • Combining 3′-Deoxy-3′-[18F] fluorothymidine and MRI increases the sensitivity of glioma volume detection

    by Philippe Fernandez, Paolo Zanotti-Fregonara, Sandrine Eimer, Edouard Gimbert, Pascal Monteil, Guillaume Penchet, Frédéric Lamare, Paul Perez, Delphine Vimont, Sylvain Ledure, et al.

    3′-Deoxy-3′-[18F] fluorothymidine (18F-FLT) is a marker of cell proliferation and displays a high tumor-to-background ratio in brain tumor lesions. We determined whether combining 18F-FLT PET and MRI study improves the detection of tumoral tissue compared to MRI alone and whether 18F-FLT uptake has a prognostic value by studying its association with histopathological features. Thirteen patients with a supratentorial malignant glioma were recruited and scheduled for surgery. The tumor volume was defined in all patients on both 18F-FLT PET and MRI images. The images were coregistered and uploaded onto a neuronavigation system. During surgery, an average of 11 biopsies per patient were taken in regions of the brain that were positive to one or both imaging modalities, as well as from control peritumoral regions. The standardized uptake values (SUVs) of each biopsy region were correlated to histopathological data (i.e., proliferation index and number of mitoses) and the SUV values of high and low-grade samples were compared. Out of a total of 149 biopsies, 109 contained tumoral tissue at histopathological analysis. The positive predictive value was 93.1% for MRI alone and 78.3% for MRI and PET combined. In addition, 40% of the biopsy samples taken from areas of the brain that were negative at both PET and MRI had evidence of malignancy at pathology. The SUV values were not significantly correlated to either the proliferation index or the number of mitoses, and could not differentiate between high- and low-grade samples. In patients with newly diagnosed glioma, a combination of MRI and 18F-FLT-PET detects additional tumoral tissue and this may lead to a more complete surgical resection. Also, the addition of a negative PET to a negative MRI increases the negative predictive value. However, 18F-FLT still underestimated the margins of the lesion and did not correlate with histopathological features.


  • Analysis of hypoxia in human glioblastoma tumors with dynamic 18F-FMISO PET imaging

    by Redha-Alla Abdo, Frédéric Lamare, Philippe Fernandez, M’hAmed Bentourkia

    Gliomas are the most common type of primary brain tumors and are classified as grade IV. Necrosis and hypoxia are essential diagnostic features which result in poor prognosis of gliomas. The aim of this study was to report quantitative temporal analyses aiming at determining the hypoxic regions in glioblastoma multiforme and to suggest an optimal time for the clinical single scan of hypoxia. Nine subjects were imaged with PET and 18F-FMISO in dynamic mode for 15 min followed with static scans at 2, 3 and 4 h post-injection. Spectral analysis, tumor-to-blood ratio (TBR) and tumor-to-normal tissue ratio (TNR) were used to delimit perfused and hypoxic tumor regions. TBR and TNR images were further scaled by thresholding at 1.2, 1.4, 2 and 2.5 levels. The images showed a varying tumor volume with time. TBR produced broader images of the tumor than TNR considering the same thresholds on intensity. Spectral analysis reliably determined hypoxia with different degrees of perfusion. By comparing TBR and TNR with spectral analysis images, weak to moderate correlation coefficients were found for most thresholding values and imaging times (range: 0 to 0.69). Hypoxic volume (HV) estimated from the net uptake rate (Ki) were changing among imaging times. The minimum HV changes were found between 3 h and 4 h, confirming that after 3 h, there was a very low exchange of 81F-FMISO between blood and tumor. On the other hand, hypoxia started to dominate the perfused tissue at 90 min, suggesting this time is suitable for a single scan acquisition irrespective of tumor status being highly hypoxic or perfused. At this time, TBR and TNR were respectively found in the nine subjects as 1.72 ± 0.22 and 1.74 ± 0.19.


  • Top Cited Papers

    CASToR: a generic data organization and processing code framework for multi-modal and multi-dimensional tomographic reconstruction

    by Thibaut Merlin, Simon Stute, Didier Benoit, Julien Bert, Thomas Carlier, Claude Comtat, Marina Filipovic, Frédéric Lamare, Dimitris Visvikis

    In tomographic medical imaging (PET, SPECT, CT), differences in data acquisition and organization are a major hurdle for the development of tomographic reconstruction software. The implementation of a given reconstruction algorithm is usually limited to a specific set of conditions, depending on the modality, the purpose of the study, the input data, or on the characteristics of the reconstruction algorithm itself. It causes restricted or limited use of algorithms, differences in implementation, code duplication, impractical code development, and difficulties for comparing different methods. This work attempts to address these issues by proposing a unified and generic code framework for formatting, processing and reconstructing acquired multi-modal and multi-dimensional data. The proposed iterative framework processes in the same way elements from list-mode (i.e. events) and histogrammed (i.e. sinogram or other bins) data sets. Each element is processed separately, which opens the way for highly parallel execution. A unique iterative algorithm engine makes use of generic core components corresponding to the main parts of the reconstruction process. Features that are specific to different modalities and algorithms are embedded into specific components inheriting from the generic abstract components. Temporal dimensions are taken into account in the core architecture. The framework is implemented in an open-source C++ parallel platform, called CASToR (customizable and advanced software for tomographic reconstruction). Performance assessments show that the time loss due to genericity remains acceptable, being one order of magnitude slower compared to a manufacturer’s software optimized for computational efficiency for a given system geometry. Specific optimizations were made possible by the underlying data set organization and processing and allowed for an average speed-up factor ranging from 1.54 to 3.07 when compared to more conventional implementations. Using parallel programming, an almost linear speed-up increase (factor of 0.85 times number of cores) was obtained in a realistic clinical PET setting. In conclusion, the proposed framework offers a substantial flexibility for the integration of new reconstruction algorithms while maintaining computation efficiency.


  • Dynamic PET image reconstruction integrating temporal regularization associated with respiratory motion correction for applications in oncology

    by Thibaut Merlin, Dimitris Visvikis, Philippe Fernandez, Frédéric Lamare

    Respiratory motion reduces both the qualitative and quantitative accuracy of PET images in oncology. This impact is more significant for quantitative applications based on kinetic modeling, where dynamic acquisitions are associated with limited statistics due to the necessity of enhanced temporal resolution. The aim of this study is to address these drawbacks, by combining a respiratory motion correction approach with temporal regularization in a unique reconstruction algorithm for dynamic PET imaging. Elastic transformation parameters for the motion correction are estimated from the non-attenuation-corrected PET images. The derived displacement matrices are subsequently used in a list-mode based OSEM reconstruction algorithm integrating a temporal regularization between the 3D dynamic PET frames, based on temporal basis functions. These functions are simultaneously estimated at each iteration, along with their relative coefficients for each image voxel. Quantitative evaluation has been performed using dynamic FDG PET/CT acquisitions of lung cancer patients acquired on a GE DRX system. The performance of the proposed method is compared with that of a standard multi-frame OSEM reconstruction algorithm. The proposed method achieved substantial improvements in terms of noise reduction while accounting for loss of contrast due to respiratory motion. Results on simulated data showed that the proposed 4D algorithms led to bias reduction values up to 40% in both tumor and blood regions for similar standard deviation levels, in comparison with a standard 3D reconstruction. Patlak parameter estimations on reconstructed images with the proposed reconstruction methods resulted in 30% and 40% bias reduction in the tumor and lung region respectively for the Patlak slope, and a 30% bias reduction for the intercept in the tumor region (a similar Patlak intercept was achieved in the lung area). Incorporation of the respiratory motion correction using an elastic model along with a temporal regularization in the reconstruction process of the PET dynamic series led to substantial quantitative improvements and motion artifact reduction. Future work will include the integration of a linear FDG kinetic model, in order to directly reconstruct parametric images.


  • Open Access

    Imaging of hypoxia in human glioblastoma with dynamic 18F-fluoromisonidazole PET

    by Redha-Alla Abdo, Frédéric Lamare, Philippe Fernandez, M’hAmed Bentourkia

    Cancer Drug Resistance is an open access journal, focusing on pharmacological aspects of drug resistance and its reversal, molecular mechanisms of drug resistance and drug classes, etc. Both clinical and experimental aspects of drug resistance in cancer are included.


  • Open Access

    123I-Iodobenzovesamicol SPECT Imaging of Cholinergic Systems in Dementia with Lewy Bodies

    by Joachim Mazère, Frédéric Lamare, Michele Allard, Philippe Fernandez, Willy Mayo

    Cholinergic alterations in Dementia with Lewy bodies (DLB) are widely documented in post mortem studies whereas in vivo studies are sparse, particularly at subcortical level. We used 123I-iodobenzovesamicol, a single Photon Emission Computed Tomography (SPECT) radiotracer of the Vesicular Acetylcholine Transporter (VAChT), to evaluate in vivo in DLB the integrity of the three main cholinergic pathways: the Ch1 (septo-hippocampal), the Ch4 (innominato-cortical) and the Ch5 (ponto-thalamic) cholinergic pathways, as well as the striatal cholinergic interneurons. Secondarily, the involvement of the cholinergic system in cognitive and neuropsychiatric disorders of DLB patients was assessed. Methods: Twelve healthy volunteers (age = 72±6.25 years) and 11 DLB patients (age = 76±10.50 years) underwent a dynamic 123I-iodobenzovesamicol SPECT scan and a magnetic resonance imaging (MRI) scan. MR images were automatically segmented, providing the volumes of several regions of interest (ROIs), including striatum and cholinergic terminals in Ch1 (hippocampus), Ch4 (cortical lobes) and Ch5 (thalamus). For each ROI and each subject, a pharmacokinetic modeling led to the calculation of 123I-iodobenzovesamicol to VAChT nondisplaceable binding potential (BPND) value. A neuropsychological evaluation of participants was performed, using the MMSE, Grober and Buchske, Isaac Set test, visual Discrimination and Wechsler tests. Cognitive fluctuations and apathy were assessed with the Walker and the Neuropsychiatric Inventory scales respectively. Results: Compared to healthy subjects, BPND values for DLB were significantly decreased In the Ch4 terminal regions of the anterior cingulate, superior and inferior parietal cortices (P = 0.0006, 0.0015, and 0.0023 respectively), in the Ch5 projecting region of thalamus (P = 0.0003) and in the striatum (P = 0.0042). All of the neuropsychological test scores were significantly lower in DLB patients than in healthy subjects. Four DLB patients with apathy and 4 DLB patients without apathy were identified. In the anterior cingulate cortex, BPND values were significantly decreased in patients with apathy (P = 0.004) and unchanged in patients without apathy compared to healthy subjects. Conclusion: Our results confirm the existence of cholinergic alterations in DLB, reaching both cortical and subcortical levels including the Ch5 pathway and the striatum. The alteration of the cholinergic transmission in the anterior cingulate cortex could be closely associated with the development of apathy.


    • 17 November 2015
      • Vol. 60  (1) , 12-24

    Motion correction using anatomical information in PET/CT and PET/MR hybrid imaging.

    by Hadi Fayad, Frederic Lamare, Thibaut Merlin, Dimitris Visvikis

    Respiratory and cardiac motion causes qualitative and quantitative inaccuracies in whole body multi-modality imaging such as positron emission tomography coupled with computed tomography (PET/CT) and positron emission tomography/magnetic resonance imaging (PET/MRI). Solutions presented to date include motion synchronized PET and corresponding anatomical acquisitions (four dimensional [4D] PET/CT, 4D PET/MR), frequently referred to as the gating approach. This method is based on the acquisition of an external surrogate using an external device (pressure belt, optical monitoring system, spirometer etc.), subsequently used to bin PET and CT or MR anatomical data into a number of gates. A first limitation of this method is the low signal to noise ratio (SNR) of the resulting motion synchronized PET frames, given that every reconstructed frame contains only part of the count statistics available throughout a motion average PET acquisition. Another limitation is that the complex motion of internal organs cannot be fully estimated, characterized and modelled using a mono-dimensional motion signal. In order to resolve such issues, many advanced techniques have been proposed which include three consecutive major steps. These are based on firstly acquiring an external or internal motion surrogate, estimating or modelling the internal motion using anatomical information extracted from 4D anatomical images (CT and/or MR) and finally correcting for motion either in the PET raw data space, the image space or incorporate it within the PET image reconstruction which is the most optimal based motion correction method in PET/CT and in PET/MR imaging. Current research efforts are concentrating on combining the last two steps within a joint motion estimation/motion correction approach, the exploitation of MRI specific motion characterization sequences and the combination of both respiratory and cardiac motion corrections. The goal of this review is to present and discuss the different steps of all these motion correction methods in PET/CT and PET/MR imaging for whole body applications.


  • Open Access

    SUVpeak Performance in Lung Cancer: Comparison to Average SUV from the 40 Hottest Voxels

    by Eric Laffon, Irene A. Burger, Frederic Lamare, Henri de Clermont, Roger Marthan

    The performance of an average standard uptake value (SUV) over a 1-mL-volume sphere within an 18F-FDG-positive lesion resulting in the highest possible value (SUVpeakW), was compared to that of an average SUV computed from the 40 hottest voxels, irrespective of their location within the lesion (SUVmax–40). Methods: A PET dynamic acquisition performed in 20 lung cancer lesions yielded for each SUV metric its mean value, relative measurement error and repeatability (MEr–R). Results: SUVpeakW mean value was significantly 9.66% lower than that of SUVmax–40 (Pmax–40 MEr–R were significantly lower than MEr-R of SUVmax (the hottest voxel): 9.35–13.21%, 8.84–12.49% versus 13.86–19.59% respectively (95%-CL; Pmax–40 MEr–R (P = 0.086). Conclusion: SUVmax–40 is more likely to represent the most metabolically active portions of tumors than SUVpeakW, with close variability performance.