Sascha Rolf
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sascha Rolf has a total of 68 co-authors. Here are the top co-authors by number of shared publications:
Gerhard Hindricks
Department of Electrophysiology, Heart Center, University of Leipzig, Leipzig, Germany
7 shared publicationsArash Arya
Department of Electrophysiology, Heart Center, University of Leipzig, Leipzig, Germany
6 shared publicationsPhilipp Sommer
Department of Electrophysiology, Heart Center, University of Leipzig, Leipzig, Germany
6 shared publications- Philipp Sommer
Universität Leipzig – Herzzentrum
6 shared publications Andreas Bollmann
Department of Electrophysiology, Heart Center, University of Leipzig, Leipzig, Germany
5 shared publicationsChristopher Piorkowski
From the Department of Electrophysiology, University of Leipzig-Heart Center, Leipzig, Germany (S.R., S.K., A.A., C.E., P.S., S.R., A.B., C.P., G.H.); Department of Electrophysiology, University of Dresden-Heart Center, Dresden, Germany (T.G., C.P.); and Department of Cardiology, Kantonsspital St. Gallen, St. Gallen, Switzerland (D.A.).
4 shared publications
Latest Publications
- 27 September 2024
- Published by Springer Nature in Herzschrittmachertherapie + Elektrophysiologie
- Vol. 35 (4) , 268-273
Erstablation von Vorhofflimmern − reicht nur eine Pulmonalvenenisolation?
- 27 September 2024
- Published by Springer Nature in Herzschrittmachertherapie + Elektrophysiologie
- Vol. 35 (4) , 268-273
Erstablation von Vorhofflimmern − reicht nur eine Pulmonalvenenisolation?
- 18 September 2018
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 54 (1) , 35-42
Catheter ablation of atrial fibrillation with nonfluoroscopic catheter visualization—a prospective randomized comparison
The application of a novel platform for nonfluoroscopic catheter sensor tracking within pre-recorded x-ray loops in the context of catheter ablation of atrial fibrillation (AF) demonstrated significant potential for reduction of fluoroscopy. We sought to provide the first prospective randomized comparison of fluoroscopy needs, procedure times, and complications in AF catheter ablation with or without additional use of nonfluoroscopic catheter visualization (NFCV).
- 18 September 2018
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 54 (1) , 35-42
Catheter ablation of atrial fibrillation with nonfluoroscopic catheter visualization—a prospective randomized comparison
The application of a novel platform for nonfluoroscopic catheter sensor tracking within pre-recorded x-ray loops in the context of catheter ablation of atrial fibrillation (AF) demonstrated significant potential for reduction of fluoroscopy. We sought to provide the first prospective randomized comparison of fluoroscopy needs, procedure times, and complications in AF catheter ablation with or without additional use of nonfluoroscopic catheter visualization (NFCV).
- 18 December 2015
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 27 (1) , 31-33
Voltage-Based Ablation: The Growing Evidence for the Role of Individually Tailored Substrate Modification for Atrial Fibrillation
- 18 December 2015
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 27 (1) , 31-33
Voltage-Based Ablation: The Growing Evidence for the Role of Individually Tailored Substrate Modification for Atrial Fibrillation
- Open Access
- 29 January 2015
- Published by Wiley in BioMed Research International
- Vol. 2015, 1-6
Irrigated Tip Catheters for Radiofrequency Ablation in Ventricular Tachycardia
Radiofrequency (RF) ablation with irrigated tip catheters decreases the likelihood of thrombus and char formation and enables the creation of larger lesions. Due to the potential dramatic consequences, the prevention of thromboembolic events is of particular importance for left-sided procedures. Although acute success rates of ventricular tachycardia (VT) ablation are satisfactory, recurrence rate is high. Apart from the progress of the underlying disease, reconduction and the lack of effective transmural lesions play a major role for VT recurrences. This paper reviews principles of lesion formation with radiofrequency and the effect of tip irrigation as well as recent advances in new technology. Potential areas of further development of catheter technology might be the improvement of mapping by better substrate definition and resolution, the introduction of bipolar and multipolar ablation techniques into clinical routine, and the use of alternative sources of energy.
- 29 January 2015
- Published by Wiley in BioMed Research International
- Vol. 2015, 1-6
Open AccessIrrigated Tip Catheters for Radiofrequency Ablation in Ventricular Tachycardia
Radiofrequency (RF) ablation with irrigated tip catheters decreases the likelihood of thrombus and char formation and enables the creation of larger lesions. Due to the potential dramatic consequences, the prevention of thromboembolic events is of particular importance for left-sided procedures. Although acute success rates of ventricular tachycardia (VT) ablation are satisfactory, recurrence rate is high. Apart from the progress of the underlying disease, reconduction and the lack of effective transmural lesions play a major role for VT recurrences. This paper reviews principles of lesion formation with radiofrequency and the effect of tip irrigation as well as recent advances in new technology. Potential areas of further development of catheter technology might be the improvement of mapping by better substrate definition and resolution, the introduction of bipolar and multipolar ablation techniques into clinical routine, and the use of alternative sources of energy.
- Top Cited Papers
- 1 October 2014
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 7 (5) , 825-833
Tailored Atrial Substrate Modification Based on Low-Voltage Areas in Catheter Ablation of Atrial Fibrillation
Background—: Reduced electrogram amplitude has been shown to correlate with diseased myocardium. We describe a novel individualized approach for catheter ablation of atrial fibrillation (AF) based on low-voltage areas (LVAs) in the left atrium (LA). We sought to assess (1) the incidence of LVAs in patients undergoing AF catheter ablation, (2) the distribution of LVAs within the LA, and (3) the effect of an individualized ablation strategy on long-term rhythm outcomes. Methods and Results—: In 178 patients with paroxysmal or persistent AF, LA voltage maps were created during sinus rhythm after circumferential pulmonary vein isolation. Subsequent substrate modification was confined to the presence of LVA (P =0.3). Success rate in a comparison group of 26 LVA patients without further substrate modification was 27%. Conclusions—: LVAs can be found at preferred sites in 10% of patients with paroxysmal AF and in 35% of patients with persistent AF. This is the first clinical report describing a consistent voltage-based approach for substrate modification in addition to circumferential pulmonary vein isolation irrespective of AF type. Application of this limited individualized approach may have the potential to compensate for the impaired 12-month outcome of patients with endocardial structural defects.
- 1 October 2014
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 7 (5) , 825-833
Top Cited PapersTailored Atrial Substrate Modification Based on Low-Voltage Areas in Catheter Ablation of Atrial Fibrillation
Background—: Reduced electrogram amplitude has been shown to correlate with diseased myocardium. We describe a novel individualized approach for catheter ablation of atrial fibrillation (AF) based on low-voltage areas (LVAs) in the left atrium (LA). We sought to assess (1) the incidence of LVAs in patients undergoing AF catheter ablation, (2) the distribution of LVAs within the LA, and (3) the effect of an individualized ablation strategy on long-term rhythm outcomes. Methods and Results—: In 178 patients with paroxysmal or persistent AF, LA voltage maps were created during sinus rhythm after circumferential pulmonary vein isolation. Subsequent substrate modification was confined to the presence of LVA (P =0.3). Success rate in a comparison group of 26 LVA patients without further substrate modification was 27%. Conclusions—: LVAs can be found at preferred sites in 10% of patients with paroxysmal AF and in 35% of patients with persistent AF. This is the first clinical report describing a consistent voltage-based approach for substrate modification in addition to circumferential pulmonary vein isolation irrespective of AF type. Application of this limited individualized approach may have the potential to compensate for the impaired 12-month outcome of patients with endocardial structural defects.
- 17 September 2014
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 26 (2) , 167-175
Sensor‐Based Electromagnetic Navigation to Facilitate Implantation of Left Ventricular Leads in Cardiac Resynchronization Therapy
Introduction Implantation of cardiac resynchronization therapy (CRT) devices can be challenging, time consuming, and fluoroscopy intense. To facilitate placement of left ventricular (LV) leads, a novel electromagnetic navigation system (MediGuide™, St. Jude Medical, St. Paul, MN, USA) has been developed, displaying real‐time 3‐D location of sensor‐embedded delivery tools superimposed on prerecorded X‐ray cine‐loops of coronary sinus venograms. We report our experience and advanced progress in the use of this new electromagnetic tracking system to guide LV lead implantation. Methods and Results Between January 2012 and December 2013, 71 consecutive patients (69 ± 9 years, 76% male) were implanted with a CRT device using the new electromagnetic tracking system. Demographics, procedural data, and periprocedural adverse events were gathered. The impact of the operator's experience, optimized workflow, and improved software technology on procedural data were analyzed. LV lead implantation was successfully achieved in all patients without severe adverse events. Total procedure time measured 87 ± 37 minutes and the median total fluoroscopy time (skin‐to‐skin) was 4.9 (2.5–7.8) minutes with a median dose‐area‐product of 476 (260–1056) cGy*cm2. An additional comparison with conventional CRT device implantations showed a significant reduction in fluoroscopy time from 8.0 (5.8; 11.5) to 4.5 (2.8; 7.3) minutes (P = 0.016) and radiation dose from 603 (330; 969) to 338 (176; 680) cGy*cm2, respectively (P = 0.044 ). Conclusion Use of the new navigation system enables safe and successful LV lead placement with improved orientation and significantly reduced radiation exposure during CRT implantation.
- 17 September 2014
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 26 (2) , 167-175
Sensor‐Based Electromagnetic Navigation to Facilitate Implantation of Left Ventricular Leads in Cardiac Resynchronization Therapy
Introduction Implantation of cardiac resynchronization therapy (CRT) devices can be challenging, time consuming, and fluoroscopy intense. To facilitate placement of left ventricular (LV) leads, a novel electromagnetic navigation system (MediGuide™, St. Jude Medical, St. Paul, MN, USA) has been developed, displaying real‐time 3‐D location of sensor‐embedded delivery tools superimposed on prerecorded X‐ray cine‐loops of coronary sinus venograms. We report our experience and advanced progress in the use of this new electromagnetic tracking system to guide LV lead implantation. Methods and Results Between January 2012 and December 2013, 71 consecutive patients (69 ± 9 years, 76% male) were implanted with a CRT device using the new electromagnetic tracking system. Demographics, procedural data, and periprocedural adverse events were gathered. The impact of the operator's experience, optimized workflow, and improved software technology on procedural data were analyzed. LV lead implantation was successfully achieved in all patients without severe adverse events. Total procedure time measured 87 ± 37 minutes and the median total fluoroscopy time (skin‐to‐skin) was 4.9 (2.5–7.8) minutes with a median dose‐area‐product of 476 (260–1056) cGy*cm2. An additional comparison with conventional CRT device implantations showed a significant reduction in fluoroscopy time from 8.0 (5.8; 11.5) to 4.5 (2.8; 7.3) minutes (P = 0.016) and radiation dose from 603 (330; 969) to 338 (176; 680) cGy*cm2, respectively (P = 0.044 ). Conclusion Use of the new navigation system enables safe and successful LV lead placement with improved orientation and significantly reduced radiation exposure during CRT implantation.
- 22 August 2014
- Vol. 78 (10) , 2402-7
Comparison of dabigatran and uninterrupted warfarin in patients with atrial fibrillation undergoing cardiac rhythm device implantations. Case-control study.
The incidence of postoperative complications following pacemaker or implantable cardioverter-defibrillator implantations in patients treated with new oral anticoagulation agents has not been studied. Here we present a first comparison of complications after cardiac rhythm device (CRD) implantations in patients with atrial fibrillation (AF) treated with dabigatran or uninterrupted warfarin. Using a case-control study design, we compared complications within 30 days after 236 CRD procedures performed under uninterrupted warfarin (n=118) or interrupted dabigatran (n=118).There were no significant differences in the baseline characteristics of both groups. In the warfarin group, 9 (8%) pocket hematomas were observed vs. 3 (3%) in the dabigatran group (P=0.075). Two complications in the warfarin group necessitated surgical intervention as opposed to none in the dabigatran group (P=0.156). The postprocedural blood loss expressed as a drop in hemoglobin was significantly greater in the warfarin group (-0.9±0.7 vs. -0.5±0.4 mmol/L, P=0.023). In the dabigatran group, 1 case of transient ischemic attack occurred. The mean time to hospital discharge was shorter in patients treated with dabigatran (2.5±2.3 vs. 3.8±4.1 days, P=0.02). The incidence and severity of bleeding complications may be lower in patients treated with periprocedurally discontinued dabigatran when compared with uninterrupted warfarin therapy. Further evaluation of peri-interventional complications and establishment of an optimal anticoagulation management protocol are needed.
- 22 August 2014
- Vol. 78 (10) , 2402-7
Comparison of dabigatran and uninterrupted warfarin in patients with atrial fibrillation undergoing cardiac rhythm device implantations. Case-control study.
The incidence of postoperative complications following pacemaker or implantable cardioverter-defibrillator implantations in patients treated with new oral anticoagulation agents has not been studied. Here we present a first comparison of complications after cardiac rhythm device (CRD) implantations in patients with atrial fibrillation (AF) treated with dabigatran or uninterrupted warfarin. Using a case-control study design, we compared complications within 30 days after 236 CRD procedures performed under uninterrupted warfarin (n=118) or interrupted dabigatran (n=118).There were no significant differences in the baseline characteristics of both groups. In the warfarin group, 9 (8%) pocket hematomas were observed vs. 3 (3%) in the dabigatran group (P=0.075). Two complications in the warfarin group necessitated surgical intervention as opposed to none in the dabigatran group (P=0.156). The postprocedural blood loss expressed as a drop in hemoglobin was significantly greater in the warfarin group (-0.9±0.7 vs. -0.5±0.4 mmol/L, P=0.023). In the dabigatran group, 1 case of transient ischemic attack occurred. The mean time to hospital discharge was shorter in patients treated with dabigatran (2.5±2.3 vs. 3.8±4.1 days, P=0.02). The incidence and severity of bleeding complications may be lower in patients treated with periprocedurally discontinued dabigatran when compared with uninterrupted warfarin therapy. Further evaluation of peri-interventional complications and establishment of an optimal anticoagulation management protocol are needed.
- 27 February 2014
- Published by Elsevier in Heart Rhythm
- Vol. 11 (5) , 871-876
Adenosine sensitivity of retrograde fast pathway conduction in patients with slow-fast atrioventricular nodal reentrant tachycardia: A prospective study
- 27 February 2014
- Published by Elsevier in Heart Rhythm
- Vol. 11 (5) , 871-876
Adenosine sensitivity of retrograde fast pathway conduction in patients with slow-fast atrioventricular nodal reentrant tachycardia: A prospective study