Fabrizio Capuani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Fabrizio Capuani has a total of 188 co-authors. Here are the top co-authors by number of shared publications:
- A. De Caro
Dipartimento di Fisica ‘E.R. Caianiello’ dell’Università and Gruppo Collegato INFN
6 shared publications - A. Paladino
INFN Sezione di Bologna, Bologna
6 shared publications - Alessandro Lonardo
INFN Sezione di Roma 1, Roma
6 shared publications - Alessandro Saputi
INFN Sezione di Ferrara
6 shared publications - Andrea Biagioni
INFN Sezione di Roma 1, Roma
6 shared publications - B Rajesh Achari
INFN Sezione di Bologna, Bologna
6 shared publications
Latest Publications
- Open Access
- 1 June 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (06) , C06003
ALCOR, a mixed-signal ASIC for SiPM readout of the ePIC-dRICH detector at the EIC
ALCOR is a mixed-signal ASIC developed for the readout of silicon photomultiplier (SiPM) sensors in the ePIC dual-radiator RICH (dRICH) detector at the future Electron-Ion Collider (EIC). The current design integrates 32 channels in an 8×4 pixel array, providing high-precision timestamping with single-photon sensitivity, data-push architecture and fully digital output. Each channel features an analog front-end compatible with both signal polarities, comprising a low-impedance input stage, four selectable gain settings, and two leading-edge discriminators with independent 6-bit DAC thresholds. Precise timing is achieved by quad-buffered, low-power TDCs with analog interpolation and 20–40 ps time bin. Additional operating modes, including time-over-threshold and slew-rate, provide indirect amplitude measurements and effective time-walk correction. The power consumption of the full channel is 12 mW with default settings. Fabricated in 110 nm CMOS technology, ALCOR has been thoroughly validated in standalone operation and coupled with multiple SiPM models. Laboratory tests using single-photon laser pulses and HPK S13360 devices demonstrated an overall time resolution below 150 ps RMS. Two beam test campaigns at CERN-PS in 2023 and 2024, employing a dRICH prototype instrumented with 2048 3×3 mm 2 SiPMs read out by ALCOR, confirmed its suitability for ring-imaging and particle-identification. A new version of the ASIC, named ALCOR-64, was designed and submitted for fabrication in April 2025. This version doubles the channel count to 64, integrates the ASIC in a ball grid array package and addresses specific EIC-driven requirements, including a programmable-width hardware shutter to inhibit events digitization and thus suppress the SiPM out-of-time DCR-induced background.
- 1 June 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (06) , C06003
Open AccessALCOR, a mixed-signal ASIC for SiPM readout of the ePIC-dRICH detector at the EIC
ALCOR is a mixed-signal ASIC developed for the readout of silicon photomultiplier (SiPM) sensors in the ePIC dual-radiator RICH (dRICH) detector at the future Electron-Ion Collider (EIC). The current design integrates 32 channels in an 8×4 pixel array, providing high-precision timestamping with single-photon sensitivity, data-push architecture and fully digital output. Each channel features an analog front-end compatible with both signal polarities, comprising a low-impedance input stage, four selectable gain settings, and two leading-edge discriminators with independent 6-bit DAC thresholds. Precise timing is achieved by quad-buffered, low-power TDCs with analog interpolation and 20–40 ps time bin. Additional operating modes, including time-over-threshold and slew-rate, provide indirect amplitude measurements and effective time-walk correction. The power consumption of the full channel is 12 mW with default settings. Fabricated in 110 nm CMOS technology, ALCOR has been thoroughly validated in standalone operation and coupled with multiple SiPM models. Laboratory tests using single-photon laser pulses and HPK S13360 devices demonstrated an overall time resolution below 150 ps RMS. Two beam test campaigns at CERN-PS in 2023 and 2024, employing a dRICH prototype instrumented with 2048 3×3 mm 2 SiPMs read out by ALCOR, confirmed its suitability for ring-imaging and particle-identification. A new version of the ASIC, named ALCOR-64, was designed and submitted for fabrication in April 2025. This version doubles the channel count to 64, integrates the ASIC in a ball grid array package and addresses specific EIC-driven requirements, including a programmable-width hardware shutter to inhibit events digitization and thus suppress the SiPM out-of-time DCR-induced background.
- Open Access
- 1 April 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (04) , C04039
Radiation tolerance tests on key components of the ePIC-dRICH readout card
The dual-radiator RICH (dRICH) detector of the ePIC experiment will employ over 300000 SiPM pixels as photosensors, organized into more than 1000 Photon Detection Units. Each PDU is a compact module, approximately 5 × 5 × 12 cm 3 in size, including four custom ASICs connected to 256 SiPMs and an FPGA-based readout card (RDO) responsible for data acquisition and control. Considering the moderately harsh radiation environment expected in the dRICH detector, this study reports on proton irradiation tests performed on key components of the RDO card to assess their tolerance to cumulative Total Ionizing Dose (TID) and Single Event Effects (SEE). All tested components demonstrated radiation tolerance beyond the TID levels expected for the dRICH environment, with the exception of the ATtiny817 microcontroller, which showed destructive failure. Furthermore, as expected, the observed Single Event Upset (SEU) rates call for appropriate mitigation strategies in the final system design.
- 1 April 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (04) , C04039
Open AccessRadiation tolerance tests on key components of the ePIC-dRICH readout card
The dual-radiator RICH (dRICH) detector of the ePIC experiment will employ over 300000 SiPM pixels as photosensors, organized into more than 1000 Photon Detection Units. Each PDU is a compact module, approximately 5 × 5 × 12 cm 3 in size, including four custom ASICs connected to 256 SiPMs and an FPGA-based readout card (RDO) responsible for data acquisition and control. Considering the moderately harsh radiation environment expected in the dRICH detector, this study reports on proton irradiation tests performed on key components of the RDO card to assess their tolerance to cumulative Total Ionizing Dose (TID) and Single Event Effects (SEE). All tested components demonstrated radiation tolerance beyond the TID levels expected for the dRICH environment, with the exception of the ATtiny817 microcontroller, which showed destructive failure. Furthermore, as expected, the observed Single Event Upset (SEU) rates call for appropriate mitigation strategies in the final system design.
- Open Access
- 1 January 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (01) , C01031
The SiPM readout plane for the ePIC-dRICH photo-detector at the EIC: overview and beam test results
The dual-radiator (dRICH) detector of the ePIC experiment at the future Electron-Ion Collider (EIC) will make use of SiPM sensors for the detection of the emitted Cherenkov light. The photo-detector will cover ∼3 m 2 with 3×3 mm 2 pixels, for a total of more than 300000 readout channels, and will be the first application of SiPMs for single-photon detection in a collider experiment. SiPMs are chosen for their low cost and high photon detection efficiency, which remains unaffected even in the presence of a high magnetic field. However, since they are not radiation-hard, careful attention is required to preserve their single-photon counting capabilities and to keep the dark count rate (DCR) under control throughout the years of operation of the ePIC experiment. DCR control can be achieved by operating SiPMs at low temperatures and by recovering radiation damage through high-temperature annealing cycles. We present an overview of the ePIC-dRICH photo-detector system. Special focus is given to development and beam test results of a large-area prototype SiPM readout plane consisting of a total of up to 2048 3×3 mm 2 sensors. The photo-detector prototype is modular and based on a novel EIC-driven photo-detection unit (PDU) developed by INFN, which integrates 256 SiPM pixel sensors, cooling and TDC electronics in a volume of ∼5×5×14 cm 3 . The prototype has been successfully tested with particle beams at CERN-PS in October 2023 and in May 2024. Results on ring images reconstructed, beam momentum scan and particle identification using the dual radiator configuration are presented. In addition, studies on radiation-induced defects using emission microscopy, and on annealing cycles used to recover radiation damage, are shown.
- 1 January 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (01) , C01031
Open AccessThe SiPM readout plane for the ePIC-dRICH photo-detector at the EIC: overview and beam test results
The dual-radiator (dRICH) detector of the ePIC experiment at the future Electron-Ion Collider (EIC) will make use of SiPM sensors for the detection of the emitted Cherenkov light. The photo-detector will cover ∼3 m 2 with 3×3 mm 2 pixels, for a total of more than 300000 readout channels, and will be the first application of SiPMs for single-photon detection in a collider experiment. SiPMs are chosen for their low cost and high photon detection efficiency, which remains unaffected even in the presence of a high magnetic field. However, since they are not radiation-hard, careful attention is required to preserve their single-photon counting capabilities and to keep the dark count rate (DCR) under control throughout the years of operation of the ePIC experiment. DCR control can be achieved by operating SiPMs at low temperatures and by recovering radiation damage through high-temperature annealing cycles. We present an overview of the ePIC-dRICH photo-detector system. Special focus is given to development and beam test results of a large-area prototype SiPM readout plane consisting of a total of up to 2048 3×3 mm 2 sensors. The photo-detector prototype is modular and based on a novel EIC-driven photo-detection unit (PDU) developed by INFN, which integrates 256 SiPM pixel sensors, cooling and TDC electronics in a volume of ∼5×5×14 cm 3 . The prototype has been successfully tested with particle beams at CERN-PS in October 2023 and in May 2024. Results on ring images reconstructed, beam momentum scan and particle identification using the dual radiator configuration are presented. In addition, studies on radiation-induced defects using emission microscopy, and on annealing cycles used to recover radiation damage, are shown.
- 10 July 2017
- Published by American Physical Society (APS) in Physical Review E
- Vol. 96 (1) , 010401
Quantifying the entropic cost of cellular growth control
Viewing the ways a living cell can organize its metabolism as the phase space of a physical system, regulation can be seen as the ability to reduce the entropy of that space by selecting specific cellular configurations that are, in some sense, optimal. Here we quantify the amount of regulation required to control a cell's growth rate by a maximum-entropy approach to the space of underlying metabolic phenotypes, where a configuration corresponds to a metabolic flux pattern as described by genome-scale models. We link the mean growth rate achieved by a population of cells to the minimal amount of metabolic regulation needed to achieve it through a phase diagram that highlights how growth suppression can be as costly (in regulatory terms) as growth enhancement. Moreover, we provide an interpretation of the inverse temperature controlling maximum-entropy distributions based on the underlying growth dynamics. Specifically, we show that the asymptotic value of for a cell population can be expected to depend on (i) the carrying capacity of the environment, (ii) the initial size of the colony, and (iii) the probability distribution from which the inoculum was sampled. Results obtained for E. coli and human cells are found to be remarkably consistent with empirical evidence.- 10 July 2017
- Published by American Physical Society (APS) in Physical Review E
- Vol. 96 (1) , 010401
Quantifying the entropic cost of cellular growth control
Viewing the ways a living cell can organize its metabolism as the phase space of a physical system, regulation can be seen as the ability to reduce the entropy of that space by selecting specific cellular configurations that are, in some sense, optimal. Here we quantify the amount of regulation required to control a cell's growth rate by a maximum-entropy approach to the space of underlying metabolic phenotypes, where a configuration corresponds to a metabolic flux pattern as described by genome-scale models. We link the mean growth rate achieved by a population of cells to the minimal amount of metabolic regulation needed to achieve it through a phase diagram that highlights how growth suppression can be as costly (in regulatory terms) as growth enhancement. Moreover, we provide an interpretation of the inverse temperature controlling maximum-entropy distributions based on the underlying growth dynamics. Specifically, we show that the asymptotic value of for a cell population can be expected to depend on (i) the carrying capacity of the environment, (ii) the initial size of the colony, and (iii) the probability distribution from which the inoculum was sampled. Results obtained for E. coli and human cells are found to be remarkably consistent with empirical evidence.- 27 May 2016
- Published by IOP Publishing in Physical Biology
- Vol. 13 (3) , 036005
Growth against entropy in bacterial metabolism: the phenotypic trade-off behind empirical growth rate distributions inE.coli
The solution space of genome-scale models of cellular metabolism provides a map between physically viable flux configurations and cellular metabolic phenotypes described, at the most basic level, by the corresponding growth rates. By sampling the solution space of E. coli 's metabolic network, we show that empirical growth rate distributions recently obtained in experiments at single-cell resolution can be explained in terms of a trade-off between the higher fitness of fast-growing phenotypes and the higher entropy of slow-growing ones. Based on this, we propose a minimal model for the evolution of a large bacterial population that captures this trade-off. The scaling relationships observed in experiments encode, in such frameworks, for the same distance from the maximum achievable growth rate, the same degree of growth rate maximization, and/or the same rate of phenotypic change. Being grounded on genome-scale metabolic network reconstructions, these results allow for multiple implications and extensions in spite of the underlying conceptual simplicity.
- 27 May 2016
- Published by IOP Publishing in Physical Biology
- Vol. 13 (3) , 036005
Growth against entropy in bacterial metabolism: the phenotypic trade-off behind empirical growth rate distributions inE.coli
The solution space of genome-scale models of cellular metabolism provides a map between physically viable flux configurations and cellular metabolic phenotypes described, at the most basic level, by the corresponding growth rates. By sampling the solution space of E. coli 's metabolic network, we show that empirical growth rate distributions recently obtained in experiments at single-cell resolution can be explained in terms of a trade-off between the higher fitness of fast-growing phenotypes and the higher entropy of slow-growing ones. Based on this, we propose a minimal model for the evolution of a large bacterial population that captures this trade-off. The scaling relationships observed in experiments encode, in such frameworks, for the same distance from the maximum achievable growth rate, the same degree of growth rate maximization, and/or the same rate of phenotypic change. Being grounded on genome-scale metabolic network reconstructions, these results allow for multiple implications and extensions in spite of the underlying conceptual simplicity.
- Open Access
- 23 December 2015
- Published by eLife Sciences Publications, Ltd in eLife
- Vol. 4
Unravelling druggable signalling networks that control F508del-CFTR proteostasis
Cystic fibrosis (CF) is caused by mutations in CF transmembrane conductance regulator (CFTR). The most frequent mutation (F508del-CFTR) results in altered proteostasis, that is, in the misfolding and intracellular degradation of the protein. The F508del-CFTR proteostasis machinery and its homeostatic regulation are well studied, while the question whether ‘classical’ signalling pathways and phosphorylation cascades might control proteostasis remains barely explored. Here, we have unravelled signalling cascades acting selectively on the F508del-CFTR folding-trafficking defects by analysing the mechanisms of action of F508del-CFTR proteostasis regulator drugs through an approach based on transcriptional profiling followed by deconvolution of their gene signatures. Targeting multiple components of these signalling pathways resulted in potent and specific correction of F508del-CFTR proteostasis and in synergy with pharmacochaperones. These results provide new insights into the physiology of cellular proteostasis and a rational basis for developing effective pharmacological correctors of the F508del-CFTR defect.
- 23 December 2015
- Published by eLife Sciences Publications, Ltd in eLife
- Vol. 4
Open AccessUnravelling druggable signalling networks that control F508del-CFTR proteostasis
Cystic fibrosis (CF) is caused by mutations in CF transmembrane conductance regulator (CFTR). The most frequent mutation (F508del-CFTR) results in altered proteostasis, that is, in the misfolding and intracellular degradation of the protein. The F508del-CFTR proteostasis machinery and its homeostatic regulation are well studied, while the question whether ‘classical’ signalling pathways and phosphorylation cascades might control proteostasis remains barely explored. Here, we have unravelled signalling cascades acting selectively on the F508del-CFTR folding-trafficking defects by analysing the mechanisms of action of F508del-CFTR proteostasis regulator drugs through an approach based on transcriptional profiling followed by deconvolution of their gene signatures. Targeting multiple components of these signalling pathways resulted in potent and specific correction of F508del-CFTR proteostasis and in synergy with pharmacochaperones. These results provide new insights into the physiology of cellular proteostasis and a rational basis for developing effective pharmacological correctors of the F508del-CFTR defect.
- Open Access
- 12 August 2015
- Published by Springer Nature in Nature Communications
- Vol. 6 (1) , 7999
Quantitative analysis reveals how EGFR activation and downregulation are coupled in normal but not in cancer cells
Ubiquitination of the epidermal growth factor receptor (EGFR) that occurs when Cbl and Grb2 bind to three phosphotyrosine residues (pY1045, pY1068 and pY1086) on the receptor displays a sharp threshold effect as a function of EGF concentration. Here we use a simple modelling approach together with experiments to show that the establishment of the threshold requires both the multiplicity of binding sites and cooperative binding of Cbl and Grb2 to the EGFR. While the threshold is remarkably robust, a more sophisticated model predicted that it could be modulated as a function of EGFR levels on the cell surface. We confirmed experimentally that the system has evolved to perform optimally at physiological levels of EGFR. As a consequence, this system displays an intrinsic weakness that causes—at the supraphysiological levels of receptor and/or ligand associated with cancer—uncoupling of the mechanisms leading to signalling through phosphorylation and attenuation through ubiquitination.
- 12 August 2015
- Published by Springer Nature in Nature Communications
- Vol. 6 (1) , 7999
Open AccessQuantitative analysis reveals how EGFR activation and downregulation are coupled in normal but not in cancer cells
Ubiquitination of the epidermal growth factor receptor (EGFR) that occurs when Cbl and Grb2 bind to three phosphotyrosine residues (pY1045, pY1068 and pY1086) on the receptor displays a sharp threshold effect as a function of EGF concentration. Here we use a simple modelling approach together with experiments to show that the establishment of the threshold requires both the multiplicity of binding sites and cooperative binding of Cbl and Grb2 to the EGFR. While the threshold is remarkably robust, a more sophisticated model predicted that it could be modulated as a function of EGFR levels on the cell surface. We confirmed experimentally that the system has evolved to perform optimally at physiological levels of EGFR. As a consequence, this system displays an intrinsic weakness that causes—at the supraphysiological levels of receptor and/or ligand associated with cancer—uncoupling of the mechanisms leading to signalling through phosphorylation and attenuation through ubiquitination.