Jukka Kujanpää
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jukka Kujanpää has a total of 210 co-authors. Here are the top co-authors by number of shared publications:
- Antti Arola
Finnish Meteorological Institute, Kuopio, Finland
18 shared publications - Johanna Tamminen
Finnish Meteorological Institute
18 shared publications - Niilo Kalakoski
Space and Earth Observation Centre, Finnish Meteorological Institute, Helsinki, Finland
14 shared publications - Kaisa Lakkala
Space and Earth Observation Centre, Finnish Meteorological Institute, Sodankylä, Finland
9 shared publications - Anders Vilhelm Lindfors
Finnish Meteorological Institute, Helsinki, Finland
7 shared publications - Seppo Hassinen
Finnish Meteorological Institute, Helsinki, Finland
7 shared publications
Latest Publications
- Open Access
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2988 (1)
UV radiation measurements at Arctic and Antarctic sites: Results from Sodankylä (67°N) and Marambio (64°S)
Spectral ultraviolet (UV) radiation measurements have been performed with a Brewer spectroradiometer at Sodankylä (67°N) since 1990. The site is located in the Arctic and affected by stratospheric ozone depletion during spring. The UV time series includes years of strong ozone depletion, which led to increased UV levels since the beginning of the 1990s. In this work, we have analyzed the time series of the time period 1990–2021. Spectral changes are analyzed in steps of 1 nm for wavelengths between 300 and 325 nm. We performed sensitivity tests by varying the start and end year of the analysis and found that results are strongly dependent on the chosen time period. Due to the high year-to-year variability in monthly means, no significant trend was found. Typical maximum values, UV index 5, occur during summer time, because the Sun is still low in the sky during the Arctic ozone depletion period, leading to UV index values lower than in the summer. However, at Marambio (64°S), Antarctica, measurements with a GUV multichannel radiometer show that UV levels can exceed those of summer time also during the ozone depletion period. The Finnish Meteorological Institute (FMI) has started Marambio’s UV measurements in 2017 in collaboration with Servicio Meteorológico Nacional, Argentina. Here we show results for the first four years of measurements 2017-2021. The maximum UV index measured during that time period, UV index 13, was measured in November-December in 2020 as a consequence of the strong and long-lasting polar vortex of that year.
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2988 (1)
Open AccessUV radiation measurements at Arctic and Antarctic sites: Results from Sodankylä (67°N) and Marambio (64°S)
Spectral ultraviolet (UV) radiation measurements have been performed with a Brewer spectroradiometer at Sodankylä (67°N) since 1990. The site is located in the Arctic and affected by stratospheric ozone depletion during spring. The UV time series includes years of strong ozone depletion, which led to increased UV levels since the beginning of the 1990s. In this work, we have analyzed the time series of the time period 1990–2021. Spectral changes are analyzed in steps of 1 nm for wavelengths between 300 and 325 nm. We performed sensitivity tests by varying the start and end year of the analysis and found that results are strongly dependent on the chosen time period. Due to the high year-to-year variability in monthly means, no significant trend was found. Typical maximum values, UV index 5, occur during summer time, because the Sun is still low in the sky during the Arctic ozone depletion period, leading to UV index values lower than in the summer. However, at Marambio (64°S), Antarctica, measurements with a GUV multichannel radiometer show that UV levels can exceed those of summer time also during the ozone depletion period. The Finnish Meteorological Institute (FMI) has started Marambio’s UV measurements in 2017 in collaboration with Servicio Meteorológico Nacional, Argentina. Here we show results for the first four years of measurements 2017-2021. The maximum UV index measured during that time period, UV index 13, was measured in November-December in 2020 as a consequence of the strong and long-lasting polar vortex of that year.
- Open Access
- 20 December 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (24) , 13399
Correction: Lamy et al. Monitoring Solar Radiation UV Exposure in the Comoros. Int. J. Environ. Res. Public Health 2021, 18, 10475
- 20 December 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (24) , 13399
Open AccessCorrection: Lamy et al. Monitoring Solar Radiation UV Exposure in the Comoros. Int. J. Environ. Res. Public Health 2021, 18, 10475
- Open Access
- 5 October 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (19) , 10475
Monitoring Solar Radiation UV Exposure in the Comoros
As part of the UV-Indien project, a station for measuring ultraviolet radiation and the cloud fraction was installed in December 2019 in Moroni, the capital of the Comoros, situated on the west coast of the island of Ngazidja. A ground measurement campaign was also carried out on 12 January 2020 during the ascent of Mount Karthala, located in the center of the island of Ngazidja. In addition, satellite estimates (Ozone Monitoring Instrument and TROPOspheric Monitoring Instrument) and model outputs (Copernicus Atmospheric Monitoring Service and Tropospheric Ultraviolet Model) were combined for this same region. On the one hand, these different measurements and estimates make it possible to quantify, evaluate, and monitor the health risk linked to exposure to ultraviolet radiation in this region, and, on the other, they help to understand how cloud cover influences the variability of UV-radiation on the ground. The measurements of the Ozone Monitoring Instrument onboard the EOS-AURA satellite, being the longest timeseries of ultraviolet measurements available in this region, make it possible to quantify the meteorological conditions in Moroni and to show that more than 80% of the ultraviolet indices are classified as high and that 60% of these are classified as extreme. The cloud cover measured in Moroni by an All Sky Camera was used to distinguish between the cases of UV index measurements taken under clear or cloudy sky conditions. The ground-based measurements thus made it possible to describe the variability of the diurnal cycle of the UV index and the influence of cloud cover on this parameter. They also permitted the satellite measurements and the results of the simulations to be validated. In clear sky conditions, a relative difference of between 6 and 11% was obtained between satellite or model estimates and ground measurements. The ultraviolet index measurement campaign on Mount Karthala showed maximum one-minute standard erythemal doses at 0.3 SED and very high daily cumulative erythemal doses at more than 80 SED. These very high levels are also observed throughout the year and all skin phototypes can exceed the daily erythemal dose threshold at more than 20 SED.
- 5 October 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (19) , 10475
Open AccessMonitoring Solar Radiation UV Exposure in the Comoros
As part of the UV-Indien project, a station for measuring ultraviolet radiation and the cloud fraction was installed in December 2019 in Moroni, the capital of the Comoros, situated on the west coast of the island of Ngazidja. A ground measurement campaign was also carried out on 12 January 2020 during the ascent of Mount Karthala, located in the center of the island of Ngazidja. In addition, satellite estimates (Ozone Monitoring Instrument and TROPOspheric Monitoring Instrument) and model outputs (Copernicus Atmospheric Monitoring Service and Tropospheric Ultraviolet Model) were combined for this same region. On the one hand, these different measurements and estimates make it possible to quantify, evaluate, and monitor the health risk linked to exposure to ultraviolet radiation in this region, and, on the other, they help to understand how cloud cover influences the variability of UV-radiation on the ground. The measurements of the Ozone Monitoring Instrument onboard the EOS-AURA satellite, being the longest timeseries of ultraviolet measurements available in this region, make it possible to quantify the meteorological conditions in Moroni and to show that more than 80% of the ultraviolet indices are classified as high and that 60% of these are classified as extreme. The cloud cover measured in Moroni by an All Sky Camera was used to distinguish between the cases of UV index measurements taken under clear or cloudy sky conditions. The ground-based measurements thus made it possible to describe the variability of the diurnal cycle of the UV index and the influence of cloud cover on this parameter. They also permitted the satellite measurements and the results of the simulations to be validated. In clear sky conditions, a relative difference of between 6 and 11% was obtained between satellite or model estimates and ground measurements. The ultraviolet index measurement campaign on Mount Karthala showed maximum one-minute standard erythemal doses at 0.3 SED and very high daily cumulative erythemal doses at more than 80 SED. These very high levels are also observed throughout the year and all skin phototypes can exceed the daily erythemal dose threshold at more than 20 SED.
- Open Access
- 12 March 2021
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 14 (3) , 2041-2053
Application of the Complete Data Fusion algorithm to the ozone profiles measured by geostationary and low-Earth-orbit satellites: a feasibility study
The new platforms for Earth observation from space are characterized by measurements made at great spatial and temporal resolutions. While this abundance of information makes it possible to detect and study localized phenomena, it may be difficult to manage this large amount of data for the study of global and large-scale phenomena. A particularly significant example is the use by assimilation systems of Level 2 products that represent gas profiles in the atmosphere. The models on which assimilation systems are based are discretized on spatial grids with horizontal dimensions of the order of tens of kilometres in which tens or hundreds of measurements may fall in the future. A simple procedure to overcome this problem is to extract a subset of the original measurements, but this involves a loss of information. Another option is the use of simple averages of the profiles, but this approach also has some limitations that we will discuss in the paper. A more advanced solution is to resort to the so-called fusion algorithms, capable of compressing the size of the dataset while limiting the information loss. A novel data fusion method, the Complete Data Fusion algorithm, was recently developed to merge a set of retrieved products in a single product a posteriori. In the present paper, we apply the Complete Data Fusion method to ozone profile measurements simulated in the thermal infrared and ultraviolet bands in a realistic scenario. Following this, the fused products are compared with the input profiles; comparisons show that the output products of data fusion have smaller total errors and higher information contents in general. The comparisons of the fused products with the fusing products are presented both at single fusion grid box scale and with a statistical analysis of the results obtained on large sets of fusion grid boxes of the same size. We also evaluate the grid box size impact, showing that the Complete Data Fusion method can be used with different grid box sizes even if this possibility is connected to the natural variability of the considered atmospheric molecule.
- 12 March 2021
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 14 (3) , 2041-2053
Open AccessApplication of the Complete Data Fusion algorithm to the ozone profiles measured by geostationary and low-Earth-orbit satellites: a feasibility study
The new platforms for Earth observation from space are characterized by measurements made at great spatial and temporal resolutions. While this abundance of information makes it possible to detect and study localized phenomena, it may be difficult to manage this large amount of data for the study of global and large-scale phenomena. A particularly significant example is the use by assimilation systems of Level 2 products that represent gas profiles in the atmosphere. The models on which assimilation systems are based are discretized on spatial grids with horizontal dimensions of the order of tens of kilometres in which tens or hundreds of measurements may fall in the future. A simple procedure to overcome this problem is to extract a subset of the original measurements, but this involves a loss of information. Another option is the use of simple averages of the profiles, but this approach also has some limitations that we will discuss in the paper. A more advanced solution is to resort to the so-called fusion algorithms, capable of compressing the size of the dataset while limiting the information loss. A novel data fusion method, the Complete Data Fusion algorithm, was recently developed to merge a set of retrieved products in a single product a posteriori. In the present paper, we apply the Complete Data Fusion method to ozone profile measurements simulated in the thermal infrared and ultraviolet bands in a realistic scenario. Following this, the fused products are compared with the input profiles; comparisons show that the output products of data fusion have smaller total errors and higher information contents in general. The comparisons of the fused products with the fusing products are presented both at single fusion grid box scale and with a statistical analysis of the results obtained on large sets of fusion grid boxes of the same size. We also evaluate the grid box size impact, showing that the Complete Data Fusion method can be used with different grid box sizes even if this possibility is connected to the natural variability of the considered atmospheric molecule.
- Open Access
- 4 March 2021
- Published by Copernicus GmbH
TROPOMI UV radiation product and recent applications
Solar ultraviolet (UV) radiation has a broad range of effects concerning life on Earth. Because of its high photon energy, UV radiation influences human health, terrestrial and aquatic ecosystems, air quality, and materials in various ways. The Sentinel 5 Precursor (S5P) mission on a sun-synchronous orbit with an ascending node equatorial crossing at 13:30, which in conjunction with a wide swath of 2600 km provides near-global daily coverage. S5P’s TROPOMI instrument measures radiation backscattered from the Earth–atmosphere system and provides observations of atmospheric composition with the best spatial resolution presently. Among other things, TROPOMI measurements are used for calculating the UV radiation reaching the Earth's surface over the sunlit part of the globe. This UV-radiation product is processed at the Finnish Meteorological Institute Copernicus Collaborative Ground segment. The product was released via FinHUB in summer 2020. The TROPOMI L2 UV product contains 36 UV parameters in total, including irradiances at four different wavelengths and dose rates for erythemal and vitamin D synthesis action spectra. All parameters are calculated for overpass time, for solar noon time, and for theoretical clear-sky conditions with no clouds or aerosols. Daily doses and accumulated irradiances are also calculated by integrating over the sunlit part of the day. In addition to UV parameters, quality flags related to the UV product and processing are generated.Validation with ground based instruments have shown that the agreement is very good, typically within 10%. The S5P is the first Copernicus mission dedicated to atmospheric observations, and it will be complemented by Sentinel 4 with geostationary orbit and Sentinel 5 on Sun-synchronous morning orbit with planned launches in the coming years. It is expected that surface UV-radiation products from these instruments will continue the present time series. The TROPOMI surface UV radiation product responds to the increasing need for information regarding the tropospheric chemistry and biologically active wavelengths of the solar spectrum reaching the surface. In this presentation we introduce the TROPOMI UV radiation product and future developments, discuss about the quality of the product and demonstrate the usefulness of the satellite UV-data by showing resent applications including among others the exceptionally high UV-radiation conditions in mid latitudes due to persistent Antarctic ozone hole in December 2020 and modeling of seasonal cycle of COVID-19. By combining the TROPOMI UV data with observations of trace gases from the same instrument, there is also a potential for new kind of applications, where satellite data can be used in novel ways to study photochemical processes in the troposphere.
- 4 March 2021
- Published by Copernicus GmbH
Open AccessTROPOMI UV radiation product and recent applications
Solar ultraviolet (UV) radiation has a broad range of effects concerning life on Earth. Because of its high photon energy, UV radiation influences human health, terrestrial and aquatic ecosystems, air quality, and materials in various ways. The Sentinel 5 Precursor (S5P) mission on a sun-synchronous orbit with an ascending node equatorial crossing at 13:30, which in conjunction with a wide swath of 2600 km provides near-global daily coverage. S5P’s TROPOMI instrument measures radiation backscattered from the Earth–atmosphere system and provides observations of atmospheric composition with the best spatial resolution presently. Among other things, TROPOMI measurements are used for calculating the UV radiation reaching the Earth's surface over the sunlit part of the globe. This UV-radiation product is processed at the Finnish Meteorological Institute Copernicus Collaborative Ground segment. The product was released via FinHUB in summer 2020. The TROPOMI L2 UV product contains 36 UV parameters in total, including irradiances at four different wavelengths and dose rates for erythemal and vitamin D synthesis action spectra. All parameters are calculated for overpass time, for solar noon time, and for theoretical clear-sky conditions with no clouds or aerosols. Daily doses and accumulated irradiances are also calculated by integrating over the sunlit part of the day. In addition to UV parameters, quality flags related to the UV product and processing are generated.Validation with ground based instruments have shown that the agreement is very good, typically within 10%. The S5P is the first Copernicus mission dedicated to atmospheric observations, and it will be complemented by Sentinel 4 with geostationary orbit and Sentinel 5 on Sun-synchronous morning orbit with planned launches in the coming years. It is expected that surface UV-radiation products from these instruments will continue the present time series. The TROPOMI surface UV radiation product responds to the increasing need for information regarding the tropospheric chemistry and biologically active wavelengths of the solar spectrum reaching the surface. In this presentation we introduce the TROPOMI UV radiation product and future developments, discuss about the quality of the product and demonstrate the usefulness of the satellite UV-data by showing resent applications including among others the exceptionally high UV-radiation conditions in mid latitudes due to persistent Antarctic ozone hole in December 2020 and modeling of seasonal cycle of COVID-19. By combining the TROPOMI UV data with observations of trace gases from the same instrument, there is also a potential for new kind of applications, where satellite data can be used in novel ways to study photochemical processes in the troposphere.
- Open Access
- 21 December 2020
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 13 (12) , 6999-7024
Validation of the TROPOspheric Monitoring Instrument (TROPOMI) surface UV radiation product
The TROPOspheric Monitoring Instrument (TROPOMI) onboard the Sentinel-5 Precursor (S5P) satellite was launched on 13 October 2017 to provide the atmospheric composition for atmosphere and climate research. The S5P is a Sun-synchronous polar-orbiting satellite providing global daily coverage. The TROPOMI swath is 2600 km wide, and the ground resolution for most data products is 7.2×3.5 km2 (5.6×3.5 km2 since 6 August 2019) at nadir. The Finnish Meteorological Institute (FMI) is responsible for the development of the TROPOMI UV algorithm and the processing of the TROPOMI surface ultraviolet (UV) radiation product which includes 36 UV parameters in total. Ground-based data from 25 sites located in arctic, subarctic, temperate, equatorial and Antarctic areas were used for validation of the TROPOMI overpass irradiance at 305, 310, 324 and 380 nm, overpass erythemally weighted dose rate/UV index, and erythemally weighted daily dose for the period from 1 January 2018 to 31 August 2019. The validation results showed that for most sites 60 %–80 % of TROPOMI data was within ±20 % of ground-based data for snow-free surface conditions. The median relative differences to ground-based measurements of TROPOMI snow-free surface daily doses were within ±10 % and ±5 % at two-thirds and at half of the sites, respectively. At several sites more than 90 % of cloud-free TROPOMI data was within ±20 % of ground-based measurements. Generally median relative differences between TROPOMI data and ground-based measurements were a little biased towards negative values (i.e. satellite data < ground-based measurement), but at high latitudes where non-homogeneous topography and albedo or snow conditions occurred, the negative bias was exceptionally high: from −30 % to −65 %. Positive biases of 10 %–15 % were also found for mountainous sites due to challenging topography. The TROPOMI surface UV radiation product includes quality flags to detect increased uncertainties in the data due to heterogeneous surface albedo and rough terrain, which can be used to filter the data retrieved under challenging conditions.
- 21 December 2020
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 13 (12) , 6999-7024
Open AccessValidation of the TROPOspheric Monitoring Instrument (TROPOMI) surface UV radiation product
The TROPOspheric Monitoring Instrument (TROPOMI) onboard the Sentinel-5 Precursor (S5P) satellite was launched on 13 October 2017 to provide the atmospheric composition for atmosphere and climate research. The S5P is a Sun-synchronous polar-orbiting satellite providing global daily coverage. The TROPOMI swath is 2600 km wide, and the ground resolution for most data products is 7.2×3.5 km2 (5.6×3.5 km2 since 6 August 2019) at nadir. The Finnish Meteorological Institute (FMI) is responsible for the development of the TROPOMI UV algorithm and the processing of the TROPOMI surface ultraviolet (UV) radiation product which includes 36 UV parameters in total. Ground-based data from 25 sites located in arctic, subarctic, temperate, equatorial and Antarctic areas were used for validation of the TROPOMI overpass irradiance at 305, 310, 324 and 380 nm, overpass erythemally weighted dose rate/UV index, and erythemally weighted daily dose for the period from 1 January 2018 to 31 August 2019. The validation results showed that for most sites 60 %–80 % of TROPOMI data was within ±20 % of ground-based data for snow-free surface conditions. The median relative differences to ground-based measurements of TROPOMI snow-free surface daily doses were within ±10 % and ±5 % at two-thirds and at half of the sites, respectively. At several sites more than 90 % of cloud-free TROPOMI data was within ±20 % of ground-based measurements. Generally median relative differences between TROPOMI data and ground-based measurements were a little biased towards negative values (i.e. satellite data < ground-based measurement), but at high latitudes where non-homogeneous topography and albedo or snow conditions occurred, the negative bias was exceptionally high: from −30 % to −65 %. Positive biases of 10 %–15 % were also found for mountainous sites due to challenging topography. The TROPOMI surface UV radiation product includes quality flags to detect increased uncertainties in the data due to heterogeneous surface albedo and rough terrain, which can be used to filter the data retrieved under challenging conditions.
- Open Access
- 15 June 2020
- Published by Copernicus GmbH
Supplementary material to "Validation of TROPOMI Surface UV Radiation Product"
- 15 June 2020
- Published by Copernicus GmbH
Open AccessSupplementary material to "Validation of TROPOMI Surface UV Radiation Product"
- Open Access
- 15 June 2020
- Published by Copernicus GmbH in EGUsphere
- Vol. 2020, 1-37
Validation of TROPOMI Surface UV Radiation Product
The TROPOspheric Monitoring Instrument (TROPOMI) onboard the Sentinel-5 Precursor (S5P) satellite was launched on 13 October 2017 to provide the atmospheric composition for atmosphere and climate research. The S5P is a sun-synchronous polar-orbiting satellite providing global daily coverage. The TROPOMI swath is 2600 km wide, and the ground resolution for most data products is 7.2 x 3.5 km2 (5.6 x 3.5 km2 since 6 August 2019) at nadir. The Finnish Meteorological Institute (FMI) is responsible for the development and processing of the TROPOMI Surface Ultraviolet (UV) Radiation Product which includes 36 UV parameters in total. Ground-based data from 25 sites located in arctic, subarctic, temperate, equatorial and antarctic areas were used for validation of TROPOMI overpass irradiance at 305, 310, 324 and 380 nm, overpass erythemally weighted dose rate/UV index and erythemally weighted daily dose for the period from 1 January 2018 to 31 August 2019. The validation results showed that for most sites 60–80 % of TROPOMI data was within ±20 % from ground-based data for snow free surface conditions. The median relative differences to ground-based measurements of TROPOMI snow free surface daily doses were within ±10 % and ±5 % at two thirds and at half of the sites, respectively. At several sites more than 90 % of clear sky TROPOMI data were within ±20 % from ground-based measurements. Generally median relative differences between TROPOMI data and ground-based measurements were a little biased towards negative values, but at high latitudes where non-homogeneous topography and albedo/snow conditions occurred, the negative bias was exceptionally high, from −30 % to −65 %. Positive biases of 10–15 % were also found for mountainous sites due to challenging topography. The TROPOMI Surface UV Radiation Product includes quality flags to detect increased uncertainties in the data due to heterogeneous surface albedo and rough terrain which can be used to filter the data retrieved under challenging conditions.
- 15 June 2020
- Published by Copernicus GmbH in EGUsphere
- Vol. 2020, 1-37
Open AccessValidation of TROPOMI Surface UV Radiation Product
The TROPOspheric Monitoring Instrument (TROPOMI) onboard the Sentinel-5 Precursor (S5P) satellite was launched on 13 October 2017 to provide the atmospheric composition for atmosphere and climate research. The S5P is a sun-synchronous polar-orbiting satellite providing global daily coverage. The TROPOMI swath is 2600 km wide, and the ground resolution for most data products is 7.2 x 3.5 km2 (5.6 x 3.5 km2 since 6 August 2019) at nadir. The Finnish Meteorological Institute (FMI) is responsible for the development and processing of the TROPOMI Surface Ultraviolet (UV) Radiation Product which includes 36 UV parameters in total. Ground-based data from 25 sites located in arctic, subarctic, temperate, equatorial and antarctic areas were used for validation of TROPOMI overpass irradiance at 305, 310, 324 and 380 nm, overpass erythemally weighted dose rate/UV index and erythemally weighted daily dose for the period from 1 January 2018 to 31 August 2019. The validation results showed that for most sites 60–80 % of TROPOMI data was within ±20 % from ground-based data for snow free surface conditions. The median relative differences to ground-based measurements of TROPOMI snow free surface daily doses were within ±10 % and ±5 % at two thirds and at half of the sites, respectively. At several sites more than 90 % of clear sky TROPOMI data were within ±20 % from ground-based measurements. Generally median relative differences between TROPOMI data and ground-based measurements were a little biased towards negative values, but at high latitudes where non-homogeneous topography and albedo/snow conditions occurred, the negative bias was exceptionally high, from −30 % to −65 %. Positive biases of 10–15 % were also found for mountainous sites due to challenging topography. The TROPOMI Surface UV Radiation Product includes quality flags to detect increased uncertainties in the data due to heterogeneous surface albedo and rough terrain which can be used to filter the data retrieved under challenging conditions.
- Open Access
- 14 January 2020
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 13 (1) , 131-152
Benefit of ozone observations from Sentinel-5P and future Sentinel-4 missions on tropospheric composition
We present an observing simulated system experiment (OSSE) dedicated to evaluate the potential added value from the Sentinel-4 and the Sentinel-5P observations on tropospheric ozone composition. For this purpose, the ozone data of Sentinel-4 (Ultraviolet Visible Near-infrared) and Sentinel-5P (TROPOspheric Monitoring Instrument) on board a geostationary (GEO) and a low-Earth-orbit (LEO) platform, respectively, have been simulated using the DISAMAR inversion package for the summer 2003. To ensure the robustness of the results, the OSSE has been configured with conservative assumptions. We simulate the reality by combining two chemistry transport models (CTMs): the LOng Term Ozone Simulation – EURopean Operational Smog (LOTOS-EUROS) and the Transport Model version 5 (TM5). The assimilation system is based on a different CTM, the MOdèle de Chimie Atmosphérique à Grande Echelle (MOCAGE), combined with the 3-D variational technique. The background error covariance matrix does not evolve in time and its variance is proportional to the field values. The simulated data are formed of six eigenvectors to minimize the size of the dataset by removing the noise-dominated part of the observations. The results show that the satellite data clearly bring direct added value around 200 hPa for the whole assimilation period and for the whole European domain, while a likely indirect added value is identified but not for the whole period and domain at 500 hPa, and to a lower extent at 700 hPa. In addition, the ozone added value from Sentinel-5P (LEO) appears close to that from Sentinel-4 (GEO) in the free troposphere (200–500 hPa) in our OSSE. The outcome of our study is a result of the OSSE design and the choice within each of the components of the system.
- 14 January 2020
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 13 (1) , 131-152
Open AccessBenefit of ozone observations from Sentinel-5P and future Sentinel-4 missions on tropospheric composition
We present an observing simulated system experiment (OSSE) dedicated to evaluate the potential added value from the Sentinel-4 and the Sentinel-5P observations on tropospheric ozone composition. For this purpose, the ozone data of Sentinel-4 (Ultraviolet Visible Near-infrared) and Sentinel-5P (TROPOspheric Monitoring Instrument) on board a geostationary (GEO) and a low-Earth-orbit (LEO) platform, respectively, have been simulated using the DISAMAR inversion package for the summer 2003. To ensure the robustness of the results, the OSSE has been configured with conservative assumptions. We simulate the reality by combining two chemistry transport models (CTMs): the LOng Term Ozone Simulation – EURopean Operational Smog (LOTOS-EUROS) and the Transport Model version 5 (TM5). The assimilation system is based on a different CTM, the MOdèle de Chimie Atmosphérique à Grande Echelle (MOCAGE), combined with the 3-D variational technique. The background error covariance matrix does not evolve in time and its variance is proportional to the field values. The simulated data are formed of six eigenvectors to minimize the size of the dataset by removing the noise-dominated part of the observations. The results show that the satellite data clearly bring direct added value around 200 hPa for the whole assimilation period and for the whole European domain, while a likely indirect added value is identified but not for the whole period and domain at 500 hPa, and to a lower extent at 700 hPa. In addition, the ozone added value from Sentinel-5P (LEO) appears close to that from Sentinel-4 (GEO) in the free troposphere (200–500 hPa) in our OSSE. The outcome of our study is a result of the OSSE design and the choice within each of the components of the system.
- Open Access
- 18 December 2019
- Published by Copernicus GmbH
Supplementary material to "The Complete Data Fusion for a Full Exploitation of Copernicus Atmospheric Sentinel Level 2 Products"
- 18 December 2019
- Published by Copernicus GmbH
Open AccessSupplementary material to "The Complete Data Fusion for a Full Exploitation of Copernicus Atmospheric Sentinel Level 2 Products"