TCTushar R. Choudhary

Tushar R. Choudhary

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tushar R. Choudhary has a total of 74 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Time-Resolved Spectroscopy of Fluorescence Quenching in Optical Fibre-Based pH Sensors

    by Katjana Ehrlich, Tushar R. Choudhary, Muhammed Ucuncu, Alicia Megia-Fernandez, Kerrianne Harrington, Harry A. C. Wood, Fei Yu, Debaditya Choudhury, Kev Dhaliwal, Mark Bradley, et al.

    Numerous optodes, with fluorophores as the chemical sensing element and optical fibres for light delivery and collection, have been fabricated for minimally invasive endoscopic measurements of key physiological parameters such as pH. These flexible miniaturised optodes have typically attempted to maximize signal-to-noise through the application of high concentrations of fluorophores. We show that high-density attachment of carboxyfluorescein onto silica microspheres, the sensing elements, results in fluorescence energy transfer, manifesting as reduced fluorescence intensity and lifetime in addition to spectral changes. We demonstrate that the change in fluorescence intensity of carboxyfluorescein with pH in this “high-density” regime is opposite to that normally observed, with complex variations in fluorescent lifetime across the emission spectra of coupled fluorophores. Improved understanding of such highly loaded sensor beads is important because it leads to large increases in photostability and will aid the development of compact fibre probes, suitable for clinical applications. The time-resolved spectral measurement techniques presented here can be further applied to similar studies of other optodes.


  • Open Access

    Molecular detection of Gram-positive bacteria in the human lung through an optical fiber–based endoscope

    by Bethany Mills, Alicia Megia-Fernandez, Dominic Norberg, Sheelagh Duncan, Adam Marshall, Ahsan R. Akram, Thomas Quinn, Irene Young, Annya M. Bruce, Emma Scholefield, et al.

    Purpose: The relentless rise in antimicrobial resistance is a major societal challenge and requires, as part of its solution, a better understanding of bacterial colonization and infection. To facilitate this, we developed a highly efficient no-wash red optical molecular imaging agent that enables the rapid, selective, and specific visualization of Gram-positive bacteria through a bespoke optical fiber–based delivery/imaging endoscopic device. Methods: We rationally designed a no-wash, red, Gram-positive-specific molecular imaging agent (Merocy-Van) based on vancomycin and an environmental merocyanine dye. We demonstrated the specificity and utility of the imaging agent in escalating in vitro and ex vivo whole human lung models (n = 3), utilizing a bespoke fiber–based delivery and imaging device, coupled to a wide-field, two-color endomicroscopy system. Results: The imaging agent (Merocy-Van) was specific to Gram-positive bacteria and enabled no-wash imaging of S. aureus within the alveolar space of whole ex vivo human lungs within 60 s of delivery into the field-of-view, using the novel imaging/delivery endomicroscopy device. Conclusion: This platform enables the rapid and specific detection of Gram-positive bacteria in the human lung.


  • Time-resolved single photon spectroscopy for optical fibre-based sensing of bacterial infections in the distal lung

    by K. Ehrlich, S. Duncan, T. R. Choudhary, B. Mills, R. R. Thomson, R. K. Henderson, M. Bradley, K. Dhaliwal, M. G. Tanner

    Endoscopic point sensing of bacterial infections in the distal lung in vivo is challenging. Here fluorescence imaging agents are combined with time-resolved fluorescence spectroscopy to overcome limitations from tissue fluorescence by measuring the fluorescence lifetime.


  • Remote sensing of blood oxygenation using red-eye pupil reflection

    by Tushar R Choudhary, Derek Ball, Javier Fernandez Ramos, Einar Stefansson, Andrew R Harvey

    Objective : To develop a technique for remote sensing of systemic blood oxygenation using red-eye pupil reflection. Approach : The ratio of the intensities of light from the bright pupil reflections at oxygen sensitive and isosbestic wavelengths is shown to be sensitive to the oxygenation of blood in the eye. A conventional retinal camera, fitted with an image-replicating imaging spectrometer, was used at standoff range to record snapshot spectral images of the face and eyes at eight different wavelengths. In our pilot study we measured optical-density ratios (ODRs) of pupil reflections at wavelengths of 780 nm and 800 nm, simultaneous with pulse oximetry, for ten healthy human subjects under conditions of normoxia and mild hypoxia (15% oxygen). The low absorption at these infrared wavelengths localises the sensing to the choroid. We propose that this can be used for as a proxy for systemic oximetry. Main results : A significant reduction ( P < 0.001) in ODR of the pupil images was observed during hypoxia and returned to baseline on resumption of normoxia. We demonstrate that measurement of the choroidal ODR can be used to detect changes in blood oxygenation that correlate positively with pulse oximetry and with a noise-equivalent oximetry precision of 0.5%. Significance : We describe a new method to remotely and non-invasively sense the oxygen saturation of choroidal blood. The methodology provides a proxy for remote sensing of cerebral and systemic blood oxygenation. We demonstrate the technique at short range but it has potential for systemic oximetry at large standoff ranges.


  • Open Access

    Fibre-based spectral ratio endomicroscopy for contrast enhancement of bacterial imaging and pulmonary autofluorescence

    by Helen E. Parker, James M. Stone, Adam D. L. Marshall, Tushar R. Choudhary, Robert R. Thomson, Kevin Dhaliwal, Michael G. Tanner

    Fibre-based optical endomicroscopy (OEM) permits high resolution fluorescence microscopy in endoscopically accessible tissues. Fibred OEM has the potential to visualise pathologies targeted with fluorescent imaging probes and provide an in vivo in situ molecular pathology platform to augment disease understanding, diagnosis and stratification. Here we present an inexpensive widefield ratiometric fibred OEM system capable of enhancing the contrast between similar spectra of pathologically relevant fluorescent signals without the burden of complex spectral unmixing. As an exemplar, we demonstrate the potential of the platform to detect fluorescently labelled Gram-negative bacteria in the challenging environment of highly autofluorescent lung tissue in whole ex vivo human lungs.


  • Open Access

    High-speed dual color fluorescence lifetime endomicroscopy for highly-multiplexed pulmonary diagnostic applications and detection of labeled bacteria

    by Ettore Pedretti, Michael G. Tanner, Tushar R. Choudhary, Nikola Krstajić, Alicia Megia-Fernandez, Robert K. Henderson, Mark Bradley, Robert R. Thomson, John M. Girkin, Kevin Dhaliwal, et al.

    We present a dual-color laser scanning endomicroscope capable of fluorescence lifetime endomicroscopy at one frame per second (FPS). The scanning system uses a coherent imaging fiber with 30,000 cores. High-speed lifetime imaging is achieved by distributing the signal over an array of 1024 parallel single-photon avalanche diode detectors (SPADs), minimizing detection dead-time maximizing the number of photons detected per excitation pulse without photon pile-up to achieve the high frame rate. This also enables dual color fluorescence imaging by temporally shifting the dual excitation lasers, with respect to each other, to separate the two spectrally distinct fluorescent decays in time. Combining the temporal encoding, to provide spectral separation, with lifetime measurements we show a one FPS, multi-channel endomicroscopy platform for clinical applications and diagnosis. We demonstrate the potential of the system by imaging SmartProbe labeled bacteria in ex vivo samples of human lung using lifetimeto differentiate bacterial fluorescence from the strong background lung autofluorescence which was used to provide structural information.


  • Open Access

    Dye-free retinal angiography using blood-oxygenation modulation

    by Lewis E MacKenzie, Tushar R Choudhary, Javier Fernandez Ramos, Nigel Benjamin, Christian Delles, Andrew R Harvey

    Fluorescence angiography (FA) is widely used for studying and diagnosing abnormalities in the retinal blood circulation, but has associated risks of nausea, skin irritation, and even death. We describe a new non-invasive angiography technique: Blood Oxygenation Modulation Angiography, in which multispectral imaging of a transient perturbation in blood-oxygen saturation, yields angiography sequences similar to FA, including key features such as sequential filling of choroidal and retinal-vessels, which underpin assessment of circulation health. This is the first non-invasive angiography technique capable of visualizing these circulation features.

  • Open Access

    Low-cost high sensitivity pulsed endomicroscopy to visualize tricolor optical signatures

    by Nikola Krstajić, Bethany Mills, Ian Murray, Adam Marshall, Dominic Norberg, Thomas H. Craven, Philip Emanuel, Tushar R. Choudhary, Gareth O. S. Williams, Emma Scholefield, et al.

    Optical molecular imaging (OMI) promises to generate insights into disease processes in vivo1 with the potential to provide in vivo molecular information in real-time based on signatures of disease. However, to deliver on this potential, there is a requirement for the development of imaging agents that allows the fluorescent detection of disease targets alongside a versatile imaging platform with multiplexing capabilities.


  • A multifunctional endoscope for imaging, fluid delivery and fluid extraction (Conference Presentation)

    by James M. Stone, Tushar Choudhary, Helen Parker, Bethany Mills, Adam Marshall, Debaditya Choudhury, Michael G. Tanner, Harry A. Wood, Kerrianne Harrington, Jonathan C. Knight, et al.

    We present a multifunctional endoscope capable of imaging, fluid delivery and fluid sampling in the alveolar space. The endoscope consists of an imaging fibre bundle fabricated from cost effective OM1 PCVD graded index preforms made for the telecommunications market. These low-cost fibres could potentially make our endoscope disposable after a single use. The performance of our low-cost imaging fibre bundle is shown to be comparable to the current commercial state-of-the-art. The imaging fibre bundle is packaged alongside two channels for the delivery and extraction of fluids. The fluid delivery channels can be used to deliver fluorescent smart probes for the detection of pathogens and to perform a targeted alveolar lavage without the removal of the imaging fibre as is currently standard procedure. Our endoscope is fully biocompatible and with an overall outer diameter of 1.4 mm allowing it to fit into the standard working channel of a bronchoscope. We demonstrate the use of our endoscope in ex-vivo human lungs. We show alveolar tissue and bacterial imaging over two wavelength bands 520 nm – 600 nm and 650 nm – 750 nm both commonly used for bacterial smart probe detection.


  • Open Access

    Controlled core-to-core photo-polymerisation – fabrication of an optical fibre-based pH sensor

    by Fuad Mohamad, Michael G. Tanner, Debaditya Choudhury, Tushar R. Choudhary, Harry A. C. Wood, Kerrianne Harrington, Mark Bradley

    The fabrication of fluorescence-based pH sensors, embedded into etched pits of an optical fibre via highly controllable and spatially selective photo-polymerisation is described and the sensors validated.