Tushar R. Choudhary
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tushar R. Choudhary has a total of 74 co-authors. Here are the top co-authors by number of shared publications:
- Michael George Tanner
Institute of Photonics and Quantum Sciences Heriot‐Watt University Edinburgh UK
10 shared publications - Kevin Dhaliwal
University of Edinburgh
7 shared publications - Bethany Mills
Centre for Inflammation Research, Institute for Regeneration and Repair, University of Edinburgh, Edinburgh, UK
6 shared publications - Mark Bradley
Precision Healthcare University Research Institute, Queen Mary University of London, Empire House, London, UK
6 shared publications - Nikola Krstajić
Institute for Integrated Micro and Nano Systems, School of Engineering, University of Edinburgh, Edinburgh, UK
4 shared publications - Ahsan R. Akram
Centre for Inflammation Research, Institute of Regeneration and Repair, University of Edinburgh, Edinburgh, UK
3 shared publications
Latest Publications
- Open Access
Time-Resolved Spectroscopy of Fluorescence Quenching in Optical Fibre-Based pH Sensors
Numerous optodes, with fluorophores as the chemical sensing element and optical fibres for light delivery and collection, have been fabricated for minimally invasive endoscopic measurements of key physiological parameters such as pH. These flexible miniaturised optodes have typically attempted to maximize signal-to-noise through the application of high concentrations of fluorophores. We show that high-density attachment of carboxyfluorescein onto silica microspheres, the sensing elements, results in fluorescence energy transfer, manifesting as reduced fluorescence intensity and lifetime in addition to spectral changes. We demonstrate that the change in fluorescence intensity of carboxyfluorescein with pH in this “high-density” regime is opposite to that normally observed, with complex variations in fluorescent lifetime across the emission spectra of coupled fluorophores. Improved understanding of such highly loaded sensor beads is important because it leads to large increases in photostability and will aid the development of compact fibre probes, suitable for clinical applications. The time-resolved spectral measurement techniques presented here can be further applied to similar studies of other optodes.
Open AccessTime-Resolved Spectroscopy of Fluorescence Quenching in Optical Fibre-Based pH Sensors
Numerous optodes, with fluorophores as the chemical sensing element and optical fibres for light delivery and collection, have been fabricated for minimally invasive endoscopic measurements of key physiological parameters such as pH. These flexible miniaturised optodes have typically attempted to maximize signal-to-noise through the application of high concentrations of fluorophores. We show that high-density attachment of carboxyfluorescein onto silica microspheres, the sensing elements, results in fluorescence energy transfer, manifesting as reduced fluorescence intensity and lifetime in addition to spectral changes. We demonstrate that the change in fluorescence intensity of carboxyfluorescein with pH in this “high-density” regime is opposite to that normally observed, with complex variations in fluorescent lifetime across the emission spectra of coupled fluorophores. Improved understanding of such highly loaded sensor beads is important because it leads to large increases in photostability and will aid the development of compact fibre probes, suitable for clinical applications. The time-resolved spectral measurement techniques presented here can be further applied to similar studies of other optodes.
- Open Access
- 11 September 2020
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 48 (3) , 800-807
Molecular detection of Gram-positive bacteria in the human lung through an optical fiber–based endoscope
Purpose: The relentless rise in antimicrobial resistance is a major societal challenge and requires, as part of its solution, a better understanding of bacterial colonization and infection. To facilitate this, we developed a highly efficient no-wash red optical molecular imaging agent that enables the rapid, selective, and specific visualization of Gram-positive bacteria through a bespoke optical fiber–based delivery/imaging endoscopic device. Methods: We rationally designed a no-wash, red, Gram-positive-specific molecular imaging agent (Merocy-Van) based on vancomycin and an environmental merocyanine dye. We demonstrated the specificity and utility of the imaging agent in escalating in vitro and ex vivo whole human lung models (n = 3), utilizing a bespoke fiber–based delivery and imaging device, coupled to a wide-field, two-color endomicroscopy system. Results: The imaging agent (Merocy-Van) was specific to Gram-positive bacteria and enabled no-wash imaging of S. aureus within the alveolar space of whole ex vivo human lungs within 60 s of delivery into the field-of-view, using the novel imaging/delivery endomicroscopy device. Conclusion: This platform enables the rapid and specific detection of Gram-positive bacteria in the human lung.
- 11 September 2020
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 48 (3) , 800-807
Open AccessMolecular detection of Gram-positive bacteria in the human lung through an optical fiber–based endoscope
Purpose: The relentless rise in antimicrobial resistance is a major societal challenge and requires, as part of its solution, a better understanding of bacterial colonization and infection. To facilitate this, we developed a highly efficient no-wash red optical molecular imaging agent that enables the rapid, selective, and specific visualization of Gram-positive bacteria through a bespoke optical fiber–based delivery/imaging endoscopic device. Methods: We rationally designed a no-wash, red, Gram-positive-specific molecular imaging agent (Merocy-Van) based on vancomycin and an environmental merocyanine dye. We demonstrated the specificity and utility of the imaging agent in escalating in vitro and ex vivo whole human lung models (n = 3), utilizing a bespoke fiber–based delivery and imaging device, coupled to a wide-field, two-color endomicroscopy system. Results: The imaging agent (Merocy-Van) was specific to Gram-positive bacteria and enabled no-wash imaging of S. aureus within the alveolar space of whole ex vivo human lungs within 60 s of delivery into the field-of-view, using the novel imaging/delivery endomicroscopy device. Conclusion: This platform enables the rapid and specific detection of Gram-positive bacteria in the human lung.
- 1 January 2020
- Published by Optica Publishing Group
- p. TTu2B.3
Time-resolved single photon spectroscopy for optical fibre-based sensing of bacterial infections in the distal lung
Endoscopic point sensing of bacterial infections in the distal lung in vivo is challenging. Here fluorescence imaging agents are combined with time-resolved fluorescence spectroscopy to overcome limitations from tissue fluorescence by measuring the fluorescence lifetime.
- 1 January 2020
- Published by Optica Publishing Group
- p. TTu2B.3
Time-resolved single photon spectroscopy for optical fibre-based sensing of bacterial infections in the distal lung
Endoscopic point sensing of bacterial infections in the distal lung in vivo is challenging. Here fluorescence imaging agents are combined with time-resolved fluorescence spectroscopy to overcome limitations from tissue fluorescence by measuring the fluorescence lifetime.
- 1 December 2019
- Published by IOP Publishing in Physiological Measurement
- Vol. 40 (12) , 12NT01
Remote sensing of blood oxygenation using red-eye pupil reflection
Objective : To develop a technique for remote sensing of systemic blood oxygenation using red-eye pupil reflection. Approach : The ratio of the intensities of light from the bright pupil reflections at oxygen sensitive and isosbestic wavelengths is shown to be sensitive to the oxygenation of blood in the eye. A conventional retinal camera, fitted with an image-replicating imaging spectrometer, was used at standoff range to record snapshot spectral images of the face and eyes at eight different wavelengths. In our pilot study we measured optical-density ratios (ODRs) of pupil reflections at wavelengths of 780 nm and 800 nm, simultaneous with pulse oximetry, for ten healthy human subjects under conditions of normoxia and mild hypoxia (15% oxygen). The low absorption at these infrared wavelengths localises the sensing to the choroid. We propose that this can be used for as a proxy for systemic oximetry. Main results : A significant reduction ( P < 0.001) in ODR of the pupil images was observed during hypoxia and returned to baseline on resumption of normoxia. We demonstrate that measurement of the choroidal ODR can be used to detect changes in blood oxygenation that correlate positively with pulse oximetry and with a noise-equivalent oximetry precision of 0.5%. Significance : We describe a new method to remotely and non-invasively sense the oxygen saturation of choroidal blood. The methodology provides a proxy for remote sensing of cerebral and systemic blood oxygenation. We demonstrate the technique at short range but it has potential for systemic oximetry at large standoff ranges.
- 1 December 2019
- Published by IOP Publishing in Physiological Measurement
- Vol. 40 (12) , 12NT01
Remote sensing of blood oxygenation using red-eye pupil reflection
Objective : To develop a technique for remote sensing of systemic blood oxygenation using red-eye pupil reflection. Approach : The ratio of the intensities of light from the bright pupil reflections at oxygen sensitive and isosbestic wavelengths is shown to be sensitive to the oxygenation of blood in the eye. A conventional retinal camera, fitted with an image-replicating imaging spectrometer, was used at standoff range to record snapshot spectral images of the face and eyes at eight different wavelengths. In our pilot study we measured optical-density ratios (ODRs) of pupil reflections at wavelengths of 780 nm and 800 nm, simultaneous with pulse oximetry, for ten healthy human subjects under conditions of normoxia and mild hypoxia (15% oxygen). The low absorption at these infrared wavelengths localises the sensing to the choroid. We propose that this can be used for as a proxy for systemic oximetry. Main results : A significant reduction ( P < 0.001) in ODR of the pupil images was observed during hypoxia and returned to baseline on resumption of normoxia. We demonstrate that measurement of the choroidal ODR can be used to detect changes in blood oxygenation that correlate positively with pulse oximetry and with a noise-equivalent oximetry precision of 0.5%. Significance : We describe a new method to remotely and non-invasively sense the oxygen saturation of choroidal blood. The methodology provides a proxy for remote sensing of cerebral and systemic blood oxygenation. We demonstrate the technique at short range but it has potential for systemic oximetry at large standoff ranges.
- Open Access
- 15 March 2019
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 10 (4) , 1856-1869
Fibre-based spectral ratio endomicroscopy for contrast enhancement of bacterial imaging and pulmonary autofluorescence
Fibre-based optical endomicroscopy (OEM) permits high resolution fluorescence microscopy in endoscopically accessible tissues. Fibred OEM has the potential to visualise pathologies targeted with fluorescent imaging probes and provide an in vivo in situ molecular pathology platform to augment disease understanding, diagnosis and stratification. Here we present an inexpensive widefield ratiometric fibred OEM system capable of enhancing the contrast between similar spectra of pathologically relevant fluorescent signals without the burden of complex spectral unmixing. As an exemplar, we demonstrate the potential of the platform to detect fluorescently labelled Gram-negative bacteria in the challenging environment of highly autofluorescent lung tissue in whole ex vivo human lungs.
- 15 March 2019
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 10 (4) , 1856-1869
Open AccessFibre-based spectral ratio endomicroscopy for contrast enhancement of bacterial imaging and pulmonary autofluorescence
Fibre-based optical endomicroscopy (OEM) permits high resolution fluorescence microscopy in endoscopically accessible tissues. Fibred OEM has the potential to visualise pathologies targeted with fluorescent imaging probes and provide an in vivo in situ molecular pathology platform to augment disease understanding, diagnosis and stratification. Here we present an inexpensive widefield ratiometric fibred OEM system capable of enhancing the contrast between similar spectra of pathologically relevant fluorescent signals without the burden of complex spectral unmixing. As an exemplar, we demonstrate the potential of the platform to detect fluorescently labelled Gram-negative bacteria in the challenging environment of highly autofluorescent lung tissue in whole ex vivo human lungs.
- Open Access
- 12 December 2018
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 10 (1) , 181-195
High-speed dual color fluorescence lifetime endomicroscopy for highly-multiplexed pulmonary diagnostic applications and detection of labeled bacteria
We present a dual-color laser scanning endomicroscope capable of fluorescence lifetime endomicroscopy at one frame per second (FPS). The scanning system uses a coherent imaging fiber with 30,000 cores. High-speed lifetime imaging is achieved by distributing the signal over an array of 1024 parallel single-photon avalanche diode detectors (SPADs), minimizing detection dead-time maximizing the number of photons detected per excitation pulse without photon pile-up to achieve the high frame rate. This also enables dual color fluorescence imaging by temporally shifting the dual excitation lasers, with respect to each other, to separate the two spectrally distinct fluorescent decays in time. Combining the temporal encoding, to provide spectral separation, with lifetime measurements we show a one FPS, multi-channel endomicroscopy platform for clinical applications and diagnosis. We demonstrate the potential of the system by imaging SmartProbe labeled bacteria in ex vivo samples of human lung using lifetimeto differentiate bacterial fluorescence from the strong background lung autofluorescence which was used to provide structural information.
- 12 December 2018
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 10 (1) , 181-195
Open AccessHigh-speed dual color fluorescence lifetime endomicroscopy for highly-multiplexed pulmonary diagnostic applications and detection of labeled bacteria
We present a dual-color laser scanning endomicroscope capable of fluorescence lifetime endomicroscopy at one frame per second (FPS). The scanning system uses a coherent imaging fiber with 30,000 cores. High-speed lifetime imaging is achieved by distributing the signal over an array of 1024 parallel single-photon avalanche diode detectors (SPADs), minimizing detection dead-time maximizing the number of photons detected per excitation pulse without photon pile-up to achieve the high frame rate. This also enables dual color fluorescence imaging by temporally shifting the dual excitation lasers, with respect to each other, to separate the two spectrally distinct fluorescent decays in time. Combining the temporal encoding, to provide spectral separation, with lifetime measurements we show a one FPS, multi-channel endomicroscopy platform for clinical applications and diagnosis. We demonstrate the potential of the system by imaging SmartProbe labeled bacteria in ex vivo samples of human lung using lifetimeto differentiate bacterial fluorescence from the strong background lung autofluorescence which was used to provide structural information.
- Open Access
Dye-free retinal angiography using blood-oxygenation modulation
Fluorescence angiography (FA) is widely used for studying and diagnosing abnormalities in the retinal blood circulation, but has associated risks of nausea, skin irritation, and even death. We describe a new non-invasive angiography technique: Blood Oxygenation Modulation Angiography, in which multispectral imaging of a transient perturbation in blood-oxygen saturation, yields angiography sequences similar to FA, including key features such as sequential filling of choroidal and retinal-vessels, which underpin assessment of circulation health. This is the first non-invasive angiography technique capable of visualizing these circulation features.
Open AccessDye-free retinal angiography using blood-oxygenation modulation
Fluorescence angiography (FA) is widely used for studying and diagnosing abnormalities in the retinal blood circulation, but has associated risks of nausea, skin irritation, and even death. We describe a new non-invasive angiography technique: Blood Oxygenation Modulation Angiography, in which multispectral imaging of a transient perturbation in blood-oxygen saturation, yields angiography sequences similar to FA, including key features such as sequential filling of choroidal and retinal-vessels, which underpin assessment of circulation health. This is the first non-invasive angiography technique capable of visualizing these circulation features.
- Open Access
- 10 July 2018
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 23 (07) , 076005-12
Low-cost high sensitivity pulsed endomicroscopy to visualize tricolor optical signatures
Optical molecular imaging (OMI) promises to generate insights into disease processes in vivo1 with the potential to provide in vivo molecular information in real-time based on signatures of disease. However, to deliver on this potential, there is a requirement for the development of imaging agents that allows the fluorescent detection of disease targets alongside a versatile imaging platform with multiplexing capabilities.
- 10 July 2018
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 23 (07) , 076005-12
Open AccessLow-cost high sensitivity pulsed endomicroscopy to visualize tricolor optical signatures
Optical molecular imaging (OMI) promises to generate insights into disease processes in vivo1 with the potential to provide in vivo molecular information in real-time based on signatures of disease. However, to deliver on this potential, there is a requirement for the development of imaging agents that allows the fluorescent detection of disease targets alongside a versatile imaging platform with multiplexing capabilities.
- 14 March 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10488, 29
A multifunctional endoscope for imaging, fluid delivery and fluid extraction (Conference Presentation)
We present a multifunctional endoscope capable of imaging, fluid delivery and fluid sampling in the alveolar space. The endoscope consists of an imaging fibre bundle fabricated from cost effective OM1 PCVD graded index preforms made for the telecommunications market. These low-cost fibres could potentially make our endoscope disposable after a single use. The performance of our low-cost imaging fibre bundle is shown to be comparable to the current commercial state-of-the-art. The imaging fibre bundle is packaged alongside two channels for the delivery and extraction of fluids. The fluid delivery channels can be used to deliver fluorescent smart probes for the detection of pathogens and to perform a targeted alveolar lavage without the removal of the imaging fibre as is currently standard procedure. Our endoscope is fully biocompatible and with an overall outer diameter of 1.4 mm allowing it to fit into the standard working channel of a bronchoscope. We demonstrate the use of our endoscope in ex-vivo human lungs. We show alveolar tissue and bacterial imaging over two wavelength bands 520 nm – 600 nm and 650 nm – 750 nm both commonly used for bacterial smart probe detection.
- 14 March 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10488, 29
A multifunctional endoscope for imaging, fluid delivery and fluid extraction (Conference Presentation)
We present a multifunctional endoscope capable of imaging, fluid delivery and fluid sampling in the alveolar space. The endoscope consists of an imaging fibre bundle fabricated from cost effective OM1 PCVD graded index preforms made for the telecommunications market. These low-cost fibres could potentially make our endoscope disposable after a single use. The performance of our low-cost imaging fibre bundle is shown to be comparable to the current commercial state-of-the-art. The imaging fibre bundle is packaged alongside two channels for the delivery and extraction of fluids. The fluid delivery channels can be used to deliver fluorescent smart probes for the detection of pathogens and to perform a targeted alveolar lavage without the removal of the imaging fibre as is currently standard procedure. Our endoscope is fully biocompatible and with an overall outer diameter of 1.4 mm allowing it to fit into the standard working channel of a bronchoscope. We demonstrate the use of our endoscope in ex-vivo human lungs. We show alveolar tissue and bacterial imaging over two wavelength bands 520 nm – 600 nm and 650 nm – 750 nm both commonly used for bacterial smart probe detection.
- Open Access
- 30 August 2017
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 142 (19) , 3569-3572
Controlled core-to-core photo-polymerisation – fabrication of an optical fibre-based pH sensor
The fabrication of fluorescence-based pH sensors, embedded into etched pits of an optical fibre via highly controllable and spatially selective photo-polymerisation is described and the sensors validated.
- 30 August 2017
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 142 (19) , 3569-3572
Open AccessControlled core-to-core photo-polymerisation – fabrication of an optical fibre-based pH sensor
The fabrication of fluorescence-based pH sensors, embedded into etched pits of an optical fibre via highly controllable and spatially selective photo-polymerisation is described and the sensors validated.