Vinod Kumar Singh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Vinod Kumar Singh has a total of 83 co-authors. Here are the top co-authors by number of shared publications:
- Rahul Kumar Gangwar
Department of Physics and Electronics, Rajdhani College, University of Delhi, New Delhi 110015, India
20 shared publications - Akhilesh Kumar Pathak
Department of Mechanical Engineering, Center for Smart Structures and Materials, Northwestern University, Evanston, IL, United States
19 shared publications Moutusi De
Optical Fiber Laboratory, Department of Physics, Indian Institute of Technology (ISM), Dhanbad, India
9 shared publicationsVanita Bhardwaj
Indian Institute of Technology (Indian School of Mines), Department of Applied Physics, Dhanbad, Jharkhand, India
9 shared publicationsTulika Khanikar
Department of Physics, Optical Fiber Laboratory, Indian Institute of Technology (Indian School of Mines), Dhanbad, India
6 shared publicationsS.S. Mishra
5 shared publications
Latest Publications
- 1 January 2026
- Published by Royal Society of Chemistry (RSC) in Nanoscale
An N-doped TiO 2 anchored Ti 3 C 2 T x MXene for high-performance supercapacitors with a coin-cell configuration
One of the most significant challenges for next-generation supercapacitors is developing high-performance electrode materials. Created with BioRender.com.
- 1 January 2026
- Published by Royal Society of Chemistry (RSC) in Nanoscale
An N-doped TiO 2 anchored Ti 3 C 2 T x MXene for high-performance supercapacitors with a coin-cell configuration
One of the most significant challenges for next-generation supercapacitors is developing high-performance electrode materials. Created with BioRender.com.
- 21 July 2025
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 17 (30) , 17830-17845
A flexible MXene–carbon nanotube-based triboelectric nanogenerator for self-powered pH sensors
Two-dimensional materials with semiconducting nature exhibit triboelectric responses, which is an important factor for the development of nanogenerators, tribotronics, and various electronic devices. Here, the manuscript describes the synthesis of MXene from the Ti3AlC2 MAX phase using the etching method, followed by the development of a flexible self-powered triboelectric nanogenerator (FTENG) based on Ti3C2Tx MXene–carbon nanotubes (CNTs), which produces an output voltage of 47.6 V, which is greater than that of the pure carbon nanotube-based TENG. For the synthesized MXene, electron microscopy and X-ray diffraction results show that Ti3C2Tx MXene has a layered morphology and forms a hexagonal structure. The band gap of Ti3C2Tx MXene is 2.1 eV, according to UV-Vis-NIR spectroscopy, indicating that it is semi-conducting. The FTENG results also reveal that the Ti3C2Tx MXene–carbon nanotube-based triboelectric nanogenerator is sensitive to varying pH. When the solution of varying pH interacts with an active triboelectric layer, its electron affinity, dielectric constant, and dielectric loss vary, causing a drastic change in the triboelectric output voltage. The dielectric constant of the MXene–multiwalled carbon nanotube is 66.54, and that of pristine carbon nanotubes is 18.06. Due to the large surface area, energy storage capacity, and dielectric enhancement of MXene, the Ti3C2Tx MXene–carbon nanotube-based triboelectric nanogenerator shows a higher output voltage than the pure carbon nanotube TENG. The current manuscript reveals a novel approach for harvesting mechanical energy to fabricate a self-powered pH sensor using Ti3C2Tx MXene and carbon nanotubes.
- 21 July 2025
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 17 (30) , 17830-17845
A flexible MXene–carbon nanotube-based triboelectric nanogenerator for self-powered pH sensors
Two-dimensional materials with semiconducting nature exhibit triboelectric responses, which is an important factor for the development of nanogenerators, tribotronics, and various electronic devices. Here, the manuscript describes the synthesis of MXene from the Ti3AlC2 MAX phase using the etching method, followed by the development of a flexible self-powered triboelectric nanogenerator (FTENG) based on Ti3C2Tx MXene–carbon nanotubes (CNTs), which produces an output voltage of 47.6 V, which is greater than that of the pure carbon nanotube-based TENG. For the synthesized MXene, electron microscopy and X-ray diffraction results show that Ti3C2Tx MXene has a layered morphology and forms a hexagonal structure. The band gap of Ti3C2Tx MXene is 2.1 eV, according to UV-Vis-NIR spectroscopy, indicating that it is semi-conducting. The FTENG results also reveal that the Ti3C2Tx MXene–carbon nanotube-based triboelectric nanogenerator is sensitive to varying pH. When the solution of varying pH interacts with an active triboelectric layer, its electron affinity, dielectric constant, and dielectric loss vary, causing a drastic change in the triboelectric output voltage. The dielectric constant of the MXene–multiwalled carbon nanotube is 66.54, and that of pristine carbon nanotubes is 18.06. Due to the large surface area, energy storage capacity, and dielectric enhancement of MXene, the Ti3C2Tx MXene–carbon nanotube-based triboelectric nanogenerator shows a higher output voltage than the pure carbon nanotube TENG. The current manuscript reveals a novel approach for harvesting mechanical energy to fabricate a self-powered pH sensor using Ti3C2Tx MXene and carbon nanotubes.
- 20 March 2023
- Published by Elsevier in Current Applied Physics
- Vol. 50, 38-45
PANI-ZnO clad modified multimode optical fiber pH sensor based on EWA
- 20 March 2023
- Published by Elsevier in Current Applied Physics
- Vol. 50, 38-45
PANI-ZnO clad modified multimode optical fiber pH sensor based on EWA
- 22 February 2023
- Published by Springer Nature in Journal of Optics
- Vol. 52 (4) , 2285-2295
TiO2 coated tapered optical fiber SPR sensor for alcohol sensing application
- 22 February 2023
- Published by Springer Nature in Journal of Optics
- Vol. 52 (4) , 2285-2295
TiO2 coated tapered optical fiber SPR sensor for alcohol sensing application
- 4 February 2023
- Published by Springer Nature in Journal of Materials Science: Materials in Electronics
- Vol. 34 (5) , 1-11
Growth of well-arrayed ZnO nanorods over no-core fiber for the measurement of glucose solution concentration
- 4 February 2023
- Published by Springer Nature in Journal of Materials Science: Materials in Electronics
- Vol. 34 (5) , 1-11
Growth of well-arrayed ZnO nanorods over no-core fiber for the measurement of glucose solution concentration
- 28 November 2022
- Published by Elsevier in Optical Fiber Technology
- Vol. 75, 103167
Tapered MMF sensor fabrication using SnO2-NPs for alcohol sensing application
- 28 November 2022
- Published by Elsevier in Optical Fiber Technology
- Vol. 75, 103167
Tapered MMF sensor fabrication using SnO2-NPs for alcohol sensing application
- 24 November 2022
- Published by Springer Nature in Plasmonics
- Vol. 18 (1) , 95-104
A Highly Sensitive Liquid–Filled Microstructured Fiber SPR Sensor for Refractive Index and Temperature Measurement
- 24 November 2022
- Published by Springer Nature in Plasmonics
- Vol. 18 (1) , 95-104
A Highly Sensitive Liquid–Filled Microstructured Fiber SPR Sensor for Refractive Index and Temperature Measurement
- 5 July 2022
- Published by Springer Nature in Optical and Quantum Electronics
- Vol. 54 (8) , 1-14
Highly sensitive plasmonic sensor based on scaled down air holes assisted photonic crystal fiber for biosensing applications
- 5 July 2022
- Published by Springer Nature in Optical and Quantum Electronics
- Vol. 54 (8) , 1-14
Highly sensitive plasmonic sensor based on scaled down air holes assisted photonic crystal fiber for biosensing applications
- 13 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 34 (13) , 691-694
Sensitivity Enhancement of Ta₂O₅ Coated PCF Based Plasmonic Sensor for Glucose Sensing Application
The present study reports on the numerical investigation carried out on a uniquely designed tantalum pentoxide (Ta 2 O 5 ) coated photonic crystal fiber (PCF) based plasmonic sensor for sensitivity enhancement and label-free biological analyte detection. A new approach is proposed to avail external sensing mechanism by introducing the solid core at fiber periphery. By analysing modal characteristics numerically using finite element method (FEM), the wavelength sensitivity is found to be increased with the increase of Ta 2 O 5 thin film thickness. Maximum increase in sensitivity is reported for Ta 2 O 5 thickness of 50 nm. Moreover, the minimum measurable deviation of the sensor lies of the order of 10 −5 representing an overall good sensing performance. The proposed fiber has good specificity, environmental stability, small size and feasible optical sensing properties which enables its suitability as plasmonic sensor. In later study, an appropriate sensing application of proposed fiber as glucose concentration (GC) sensor is investigated for Ta 2 O 5 thickness of 50 nm. From the detail study, sensitivity is found to be varied linearly with GC and an average sensitivity of 0.81429 nm/g/L is achieved.
- 13 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 34 (13) , 691-694
Sensitivity Enhancement of Ta₂O₅ Coated PCF Based Plasmonic Sensor for Glucose Sensing Application
The present study reports on the numerical investigation carried out on a uniquely designed tantalum pentoxide (Ta 2 O 5 ) coated photonic crystal fiber (PCF) based plasmonic sensor for sensitivity enhancement and label-free biological analyte detection. A new approach is proposed to avail external sensing mechanism by introducing the solid core at fiber periphery. By analysing modal characteristics numerically using finite element method (FEM), the wavelength sensitivity is found to be increased with the increase of Ta 2 O 5 thin film thickness. Maximum increase in sensitivity is reported for Ta 2 O 5 thickness of 50 nm. Moreover, the minimum measurable deviation of the sensor lies of the order of 10 −5 representing an overall good sensing performance. The proposed fiber has good specificity, environmental stability, small size and feasible optical sensing properties which enables its suitability as plasmonic sensor. In later study, an appropriate sensing application of proposed fiber as glucose concentration (GC) sensor is investigated for Ta 2 O 5 thickness of 50 nm. From the detail study, sensitivity is found to be varied linearly with GC and an average sensitivity of 0.81429 nm/g/L is achieved.