Fumiaki Takahashi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Fumiaki Takahashi has a total of 101 co-authors. Here are the top co-authors by number of shared publications:
Viswanath R. Katta
24 shared publicationsGregory T. Linteris
14 shared publicationsViswanath Katta
Innovative Scientific Solutions, Inc
10 shared publicationsGregory Linteris
National Institute of Standards and Technology
6 shared publicationsW. John Schmoll
University of Dayton Research Institute , 300 College Park, Dayton, Ohio, 45469
6 shared publicationsValeri I. Babushok
5 shared publications
Latest Publications
- 27 August 2022
- Published by Elsevier in Proceedings of the Combustion Institute
- Vol. 39 (2) , 1657-1667
Critical conditions at liftoff limit of a laminar n-butane-air jet diffusion flame
- 27 August 2022
- Published by Elsevier in Proceedings of the Combustion Institute
- Vol. 39 (2) , 1657-1667
Critical conditions at liftoff limit of a laminar n-butane-air jet diffusion flame
- Open Access
- 24 June 2021
- Published by Springer Nature in MRS Bulletin
- Vol. 46 (7) , 642
Correction to: Fire blanket and intumescent coating materials for failure resistance
- 24 June 2021
- Published by Springer Nature in MRS Bulletin
- Vol. 46 (7) , 642
Open AccessCorrection to: Fire blanket and intumescent coating materials for failure resistance
- Open Access
- 26 April 2021
- Published by Springer Nature in MRS Bulletin
- Vol. 46 (5) , 429-434
Fire blanket and intumescent coating materials for failure resistance
There is major fire safety concern about failure propagation of thermal runaway in multicell lithium-ion batteries. This article overviews the passive fire-protection approach based on thermal insulation by intumescent coating materials and fire blankets for viable failure resistance. The intumescent coating will expand (up to 100× on heating) to form a thick, porous char layer and act as a thermal barrier to insulate the substrate. It is also used to seal around openings in a wall or floor to impede the spread of fire and smoke. High-temperature fire blankets are made of noncombustible or flame-resistant fabric materials (e.g., aramids, fiberglass, amorphous silica, preoxidized carbon, and mineral fibers). Both working intumescent coating and fire blankets can block a significant portion (typically 60 to 90%) of the incident heat. Impact-resistant high-strength fabrics, in either soft or rigid forms, can also be used as parts of multilayer protection assembly. Thus, multilayer assemblies can be used for various commercial products, including passive and active fire-protection blankets, battery-cell partitions, confinement bags and containers, packaging materials, and personal protective equipment.
- 26 April 2021
- Published by Springer Nature in MRS Bulletin
- Vol. 46 (5) , 429-434
Open AccessFire blanket and intumescent coating materials for failure resistance
There is major fire safety concern about failure propagation of thermal runaway in multicell lithium-ion batteries. This article overviews the passive fire-protection approach based on thermal insulation by intumescent coating materials and fire blankets for viable failure resistance. The intumescent coating will expand (up to 100× on heating) to form a thick, porous char layer and act as a thermal barrier to insulate the substrate. It is also used to seal around openings in a wall or floor to impede the spread of fire and smoke. High-temperature fire blankets are made of noncombustible or flame-resistant fabric materials (e.g., aramids, fiberglass, amorphous silica, preoxidized carbon, and mineral fibers). Both working intumescent coating and fire blankets can block a significant portion (typically 60 to 90%) of the incident heat. Impact-resistant high-strength fabrics, in either soft or rigid forms, can also be used as parts of multilayer protection assembly. Thus, multilayer assemblies can be used for various commercial products, including passive and active fire-protection blankets, battery-cell partitions, confinement bags and containers, packaging materials, and personal protective equipment.
- 1 January 2021
- Published by Elsevier in Proceedings of the Combustion Institute
- Vol. 38 (3) , 4645-4653
Numerical and experimental studies of extinguishment of cup-burner flames by C6F12O
- 1 January 2021
- Published by Elsevier in Proceedings of the Combustion Institute
- Vol. 38 (3) , 4645-4653
Numerical and experimental studies of extinguishment of cup-burner flames by C6F12O
- Open Access
- 15 October 2019
- Published by Frontiers Media SA in Frontiers in Mechanical Engineering
- Vol. 5
Whole-House Fire Blanket Protection From Wildland-Urban Interface Fires
Each year, fires in the wildland-urban interface (WUI)—the place where homes and wildlands meet or intermingle—have caused significant damage to communities. To contribute to firefighter and public safety by reducing the risk of structure ignition, fire blankets for wrapping a whole house have been investigated in the laboratory and prescribed wildland fires. The fire blankets aim to prevent structure ignition (1) by blocking firebrands to enter homes through vulnerable spots (gutters, eaves, vents, broken windows, and roofs); (2) by keeping homes from making direct contact with flames of surrounding combustibles (vegetation, mulch, etc.); and (3) by reflecting thermal radiation from a large fire within close range (adjacent burning houses or surface-to-crown forest fires) for a sustained period of time. In the laboratory experiment, two-layer thin fabric assemblies were able to block up to 92% of the convective heat and up to 96% of the radiation (with an aluminized surface). A series of proof-of-concept experiments were conducted by placing instrumented wooden structures, covered with different fire blankets, in various fires in ascending order of size. First, birdhouse-sized boxes were exposed to burning wood pallets in a burn room. Second, wall-and-eave panels were exposed to prescribed fires climbing up slopes with chaparral vegetation in California. Finally, a cedar shed was placed in the passage of the prescribed head fire in the Pine Barrens in New Jersey. The experiments demonstrated both successful performance and technical limitations of thin fire blankets. The key success factors in protecting the WUI structure are (1) the fire blanket's heat-blocking capability, (2) endurance under severe heat-exposure high-wind conditions, and (3) proper installation. Additional studies are needed in the areas of advanced material/layer development, blanket deployment methods, and multi-structure protection strategies.
- 15 October 2019
- Published by Frontiers Media SA in Frontiers in Mechanical Engineering
- Vol. 5
Open AccessWhole-House Fire Blanket Protection From Wildland-Urban Interface Fires
Each year, fires in the wildland-urban interface (WUI)—the place where homes and wildlands meet or intermingle—have caused significant damage to communities. To contribute to firefighter and public safety by reducing the risk of structure ignition, fire blankets for wrapping a whole house have been investigated in the laboratory and prescribed wildland fires. The fire blankets aim to prevent structure ignition (1) by blocking firebrands to enter homes through vulnerable spots (gutters, eaves, vents, broken windows, and roofs); (2) by keeping homes from making direct contact with flames of surrounding combustibles (vegetation, mulch, etc.); and (3) by reflecting thermal radiation from a large fire within close range (adjacent burning houses or surface-to-crown forest fires) for a sustained period of time. In the laboratory experiment, two-layer thin fabric assemblies were able to block up to 92% of the convective heat and up to 96% of the radiation (with an aluminized surface). A series of proof-of-concept experiments were conducted by placing instrumented wooden structures, covered with different fire blankets, in various fires in ascending order of size. First, birdhouse-sized boxes were exposed to burning wood pallets in a burn room. Second, wall-and-eave panels were exposed to prescribed fires climbing up slopes with chaparral vegetation in California. Finally, a cedar shed was placed in the passage of the prescribed head fire in the Pine Barrens in New Jersey. The experiments demonstrated both successful performance and technical limitations of thin fire blankets. The key success factors in protecting the WUI structure are (1) the fire blanket's heat-blocking capability, (2) endurance under severe heat-exposure high-wind conditions, and (3) proper installation. Additional studies are needed in the areas of advanced material/layer development, blanket deployment methods, and multi-structure protection strategies.
- 1 January 2019
- Published by Elsevier in Proceedings of the Combustion Institute
- Vol. 37 (3) , 4145-4153
Numerical study of gas-phase interactions of phosphorus-containing compounds with co-flow diffusion flames
- 1 January 2019
- Published by Elsevier in Proceedings of the Combustion Institute
- Vol. 37 (3) , 4145-4153
Numerical study of gas-phase interactions of phosphorus-containing compounds with co-flow diffusion flames
- 27 November 2018
- Published by Springer Nature in Fire Technology
- Vol. 55 (3) , 689-712
Computer Tomography Based Structure Characterization of Expanded Intumescent Coatings for Fire Protection
- 27 November 2018
- Published by Springer Nature in Fire Technology
- Vol. 55 (3) , 689-712
Computer Tomography Based Structure Characterization of Expanded Intumescent Coatings for Fire Protection
- 16 August 2018
- Published by SAGE Publications in Journal of Fire Sciences
- Vol. 36 (5) , 419-437
In situ thermal-conductivity measurements and morphological characterization of intumescent coatings for fire protection
Thermal insulating performance and char-layer properties have been studied for water-based intumescent coatings for structural steel fire protection using a new laboratory-scale mass-loss cone apparatus. A specimen (100 × 100 mm mild steel plate; the initial coating thickness: 0.3–2.0 mm) is placed horizontally and exposed to a constant incident radiant heat flux (25, 50, or 75 kW/m 2 ). The apparent thermal conductivity of the expanding char layer is determined in situ based on real-time measurements of the temperature distribution in the char layer and the heat flux transmitted through the char layer. Three-dimensional morphological observations of the expanded char layer are made using a computed tomographic–based analytical method. The vertical variation of the porosity of the expanded char layer is measured. The measured heat-blocking efficiency is correlated strongly with the incident heat flux, which increases the expanded char-layer thickness, and porosity for sufficiently large initial coating thicknesses (>0.76 mm). For a thin coating (0.30 mm), violent off-gassing disrupts the intumescing processes to form a consistent char layer after abrupt exposure to higher incident heat fluxes, thus resulting in lower heat-blocking efficiency. Therefore, the product application thickness must exceed a proper threshold value to ensure an adequate thermal insulation performance.
- 16 August 2018
- Published by SAGE Publications in Journal of Fire Sciences
- Vol. 36 (5) , 419-437
In situ thermal-conductivity measurements and morphological characterization of intumescent coatings for fire protection
Thermal insulating performance and char-layer properties have been studied for water-based intumescent coatings for structural steel fire protection using a new laboratory-scale mass-loss cone apparatus. A specimen (100 × 100 mm mild steel plate; the initial coating thickness: 0.3–2.0 mm) is placed horizontally and exposed to a constant incident radiant heat flux (25, 50, or 75 kW/m 2 ). The apparent thermal conductivity of the expanding char layer is determined in situ based on real-time measurements of the temperature distribution in the char layer and the heat flux transmitted through the char layer. Three-dimensional morphological observations of the expanded char layer are made using a computed tomographic–based analytical method. The vertical variation of the porosity of the expanded char layer is measured. The measured heat-blocking efficiency is correlated strongly with the incident heat flux, which increases the expanded char-layer thickness, and porosity for sufficiently large initial coating thicknesses (>0.76 mm). For a thin coating (0.30 mm), violent off-gassing disrupts the intumescing processes to form a consistent char layer after abrupt exposure to higher incident heat fluxes, thus resulting in lower heat-blocking efficiency. Therefore, the product application thickness must exceed a proper threshold value to ensure an adequate thermal insulation performance.
- 31 May 2018
- Published by Springer Nature in Microgravity Science and Technology
- Vol. 30 (4) , 339-351
Cool-Flame Burning and Oscillations of Envelope Diffusion Flames in Microgravity
- 31 May 2018
- Published by Springer Nature in Microgravity Science and Technology
- Vol. 30 (4) , 339-351
Cool-Flame Burning and Oscillations of Envelope Diffusion Flames in Microgravity
- 1 July 2017
- Published by Elsevier in Fire Safety Journal
- Vol. 91, 688-694
A computational study of extinguishment and enhancement of propane cup-burner flames by halon and alternative agents
- 1 July 2017
- Published by Elsevier in Fire Safety Journal
- Vol. 91, 688-694
A computational study of extinguishment and enhancement of propane cup-burner flames by halon and alternative agents