Bongjin Jeong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Bongjin Jeong has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
Rashida Akter
Graduate School of Analytical Science and Technology, Chungnam National University, Daejeon, Republic of Korea
8 shared publications- Aminur Rahman
Graduate School of Analytical Science and Technology, Chungnam National University, Daejeon 305-764, South Korea
6 shared publications Oc Hee Han
3 shared publicationsAminur Rahman
2 shared publications- Choong Kyun Rhee
Department of Chemistry, Chungnam National University, Daejeon 34134, Republic of Korea
2 shared publications - Do Yeob Kim
ICT Creative Research Laboratory, Electronics & Telecommunications Research Institute, Daejeon 34129, Korea
2 shared publications
Latest Publications
- Open Access
Ion-Selective Electrode Based on a Novel Biomimetic Nicotinamide Compound for Phosphate Ion Sensor
Phosphorus is not only an import nutrient to aquatic habitats, but it also acts as a growth inhibitor in aquatic ecosystems; however, it also aggravates environmental issues, such as eutrophication. There is a growing interest in rapid phosphorus detection to manage and protect water resources. Due to the large molecular structure and high hydration energy of phosphate ions, ion-selective electrodes (ISEs) remain in their infancy for real-time measurements in terms of practical application. In this study, a newly developed ionophore based on a biomimetic nicotinamide functional group was used to detect phosphate selectively, displaying efficient binding through charge interactions and hydrogen bonds. The ISE membrane containing silicone rubber demonstrated an effective detection performance over a long period of time. With a dynamic range between 10−6 and 10−2 M and a limit of detection of 0.85 × 10−6 M (26 μg/L), the newly synthesized ISE membranes demonstrated selectivity for phosphate ions over other ions, including acetate, sulfate, and chloride.
Open AccessIon-Selective Electrode Based on a Novel Biomimetic Nicotinamide Compound for Phosphate Ion Sensor
Phosphorus is not only an import nutrient to aquatic habitats, but it also acts as a growth inhibitor in aquatic ecosystems; however, it also aggravates environmental issues, such as eutrophication. There is a growing interest in rapid phosphorus detection to manage and protect water resources. Due to the large molecular structure and high hydration energy of phosphate ions, ion-selective electrodes (ISEs) remain in their infancy for real-time measurements in terms of practical application. In this study, a newly developed ionophore based on a biomimetic nicotinamide functional group was used to detect phosphate selectively, displaying efficient binding through charge interactions and hydrogen bonds. The ISE membrane containing silicone rubber demonstrated an effective detection performance over a long period of time. With a dynamic range between 10−6 and 10−2 M and a limit of detection of 0.85 × 10−6 M (26 μg/L), the newly synthesized ISE membranes demonstrated selectivity for phosphate ions over other ions, including acetate, sulfate, and chloride.
- Open Access
- 25 May 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-8
Novel electrochemical PMI marker biosensor based on quantum dot dissolution using a double-label strategy
A novel and facile post-mortem interval (PMI) biosensor was fabricated using a double-label strategy to detect the glyceraldehyde 3-phosphate dehydrogenase (GAPDH) biomarker. A monoclonal anti-GAPDH antibody was immobilized on a surface label containing cadmium selenide quantum dots (CdSe QDs) on a cysteamine graphene oxide (Cys-GO) self-assembled monolayer. Glucose oxidase (GOx) was used as a signal label to conjugate with GAPDH. GAPDH recognition was achieved through the dissolution of the surface-attached CdSe QDs by hydrogen peroxide generated through GAPDH-conjugated GOx-catalyzed β-glucose oxidation. To enhance sensitivity, a competitive interaction was introduced between free and conjugated GAPDH to the active site of the anti-GAPDH antibody. The electrochemical response due to CdSe dissolution decreased proportionally with the concentration of free GAPDH. Differential pulsed voltammetry was conducted to determine the analytical characteristics of the immunosensor, including the limit of detection, linear dynamic range, target selectivity, system stability, and applicability toward the analysis of real samples.
- 25 May 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-8
Open AccessNovel electrochemical PMI marker biosensor based on quantum dot dissolution using a double-label strategy
A novel and facile post-mortem interval (PMI) biosensor was fabricated using a double-label strategy to detect the glyceraldehyde 3-phosphate dehydrogenase (GAPDH) biomarker. A monoclonal anti-GAPDH antibody was immobilized on a surface label containing cadmium selenide quantum dots (CdSe QDs) on a cysteamine graphene oxide (Cys-GO) self-assembled monolayer. Glucose oxidase (GOx) was used as a signal label to conjugate with GAPDH. GAPDH recognition was achieved through the dissolution of the surface-attached CdSe QDs by hydrogen peroxide generated through GAPDH-conjugated GOx-catalyzed β-glucose oxidation. To enhance sensitivity, a competitive interaction was introduced between free and conjugated GAPDH to the active site of the anti-GAPDH antibody. The electrochemical response due to CdSe dissolution decreased proportionally with the concentration of free GAPDH. Differential pulsed voltammetry was conducted to determine the analytical characteristics of the immunosensor, including the limit of detection, linear dynamic range, target selectivity, system stability, and applicability toward the analysis of real samples.
- Open Access
Reusable and pH-Stable Luminescent Sensors for Highly Selective Detection of Phosphate
Phosphate sensors have been actively studied owing to their importance in water environment monitoring because phosphate is one of the nutrients that result in algal blooms. As with other nutrients, seamless monitoring of phosphate is important for understanding and evaluating eutrophication. However, field-deployable phosphate sensors have not been well developed yet due to the chemical characteristics of phosphate. In this paper, we report on a luminescent coordination polymer particle (CPP) that can respond selectively and sensitively to a phosphate ion against other ions in an aquatic ecosystem. The CPPs with an average size of 88.1 ± 12.2 nm are embedded into membranes for reusable purpose. Due to the specific binding of phosphates to europium ions, the luminescence quenching behavior of CPPs embedded into membranes shows a linear relationship with phosphate concentrations (3–500 μM) and detection limit of 1.52 μM. Consistent luminescence signals were also observed during repeated measurements in the pH range of 3–10. Moreover, the practical application was confirmed by sensing phosphate in actual environmental samples such as tap water and lake water.
Open AccessReusable and pH-Stable Luminescent Sensors for Highly Selective Detection of Phosphate
Phosphate sensors have been actively studied owing to their importance in water environment monitoring because phosphate is one of the nutrients that result in algal blooms. As with other nutrients, seamless monitoring of phosphate is important for understanding and evaluating eutrophication. However, field-deployable phosphate sensors have not been well developed yet due to the chemical characteristics of phosphate. In this paper, we report on a luminescent coordination polymer particle (CPP) that can respond selectively and sensitively to a phosphate ion against other ions in an aquatic ecosystem. The CPPs with an average size of 88.1 ± 12.2 nm are embedded into membranes for reusable purpose. Due to the specific binding of phosphates to europium ions, the luminescence quenching behavior of CPPs embedded into membranes shows a linear relationship with phosphate concentrations (3–500 μM) and detection limit of 1.52 μM. Consistent luminescence signals were also observed during repeated measurements in the pH range of 3–10. Moreover, the practical application was confirmed by sensing phosphate in actual environmental samples such as tap water and lake water.
- Open Access
- 2 September 2020
- Published by Springer Nature in Research Square
Nanomesh-patterning on multilayer MoS2 field-effect transistors for ultra-sensitive detection of cortisol
Absence of functional groups on the basal plane of molybdenum disulfide (MoS2) significantly hinders the performance of MoS2 field-effect transistor-based biosensor (bio-FET). We present a novel method for creating nano-scale holes on a MoS2 channel using block copolymer lithography, where the edge areas on the nanoholes were used to form covalent linkage between the capture molecules of cortisol aptamer and the MoS2 channel. The comparative analysis of Raman and XPS spectra well supported the formation of the nanoholes on MoS2 together with the concomitant increase in the edge area. The performance of the nanomesh bio-FET was studied by comparing its detection behavior for cortisol with that of a bio-FET manufactured with pristine MoS2. The nanomesh MoS2 bio-FET detected cortisol 109 times as low as that by the pristine MoS2 bio-FET. The selectivity of the nanomesh bio-FET was validated by detection experiments with other steroid hormones and antigens. Additionally, clinical applicability was demonstrated by performing experiments in artificial saliva and human serum.
- 2 September 2020
- Published by Springer Nature in Research Square
Open AccessNanomesh-patterning on multilayer MoS2 field-effect transistors for ultra-sensitive detection of cortisol
Absence of functional groups on the basal plane of molybdenum disulfide (MoS2) significantly hinders the performance of MoS2 field-effect transistor-based biosensor (bio-FET). We present a novel method for creating nano-scale holes on a MoS2 channel using block copolymer lithography, where the edge areas on the nanoholes were used to form covalent linkage between the capture molecules of cortisol aptamer and the MoS2 channel. The comparative analysis of Raman and XPS spectra well supported the formation of the nanoholes on MoS2 together with the concomitant increase in the edge area. The performance of the nanomesh bio-FET was studied by comparing its detection behavior for cortisol with that of a bio-FET manufactured with pristine MoS2. The nanomesh MoS2 bio-FET detected cortisol 109 times as low as that by the pristine MoS2 bio-FET. The selectivity of the nanomesh bio-FET was validated by detection experiments with other steroid hormones and antigens. Additionally, clinical applicability was demonstrated by performing experiments in artificial saliva and human serum.
- 1 August 2019
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 846, 113127
Label-free electrochemical quantification of microRNA-375 in prostate cancer cells
- 1 August 2019
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 846, 113127
Label-free electrochemical quantification of microRNA-375 in prostate cancer cells
- 24 November 2018
- Published by Springer Nature
- Vol. 1064, 61-71
Graphene-Based Nanomaterials and Their Applications in Biosensors
Recently graphene has been drawing tremendous attention mainly due to its potential contributions to applications in biology, information technology and energy. Among these applications graphene-based biosensors have been particularly progressed caused in part by development of diverse derivatives of graphene such as graphene oxides (GOs) and graphene quantum dots (GQDs). In this chapter preparation and functionalization of the graphene and GOQs are described together with their optoelectronic properties. Recent progresses in graphene and GQD-based biosensors are also highlighted with emphasis on immunoassay which utilizes unique interaction between antigen and antibody, and oligonucleotide assay which utilizes hybridization process. Since electrical and optical features are the most prominent characteristics of graphene-based nanomaterials, biosensor systems will be focused on electrochemical and fluorescence-based detection scheme.
- 24 November 2018
- Published by Springer Nature
- Vol. 1064, 61-71
Graphene-Based Nanomaterials and Their Applications in Biosensors
Recently graphene has been drawing tremendous attention mainly due to its potential contributions to applications in biology, information technology and energy. Among these applications graphene-based biosensors have been particularly progressed caused in part by development of diverse derivatives of graphene such as graphene oxides (GOs) and graphene quantum dots (GQDs). In this chapter preparation and functionalization of the graphene and GOQs are described together with their optoelectronic properties. Recent progresses in graphene and GQD-based biosensors are also highlighted with emphasis on immunoassay which utilizes unique interaction between antigen and antibody, and oligonucleotide assay which utilizes hybridization process. Since electrical and optical features are the most prominent characteristics of graphene-based nanomaterials, biosensor systems will be focused on electrochemical and fluorescence-based detection scheme.
- Open Access
Synergistic Use of Gold Nanoparticles (AuNPs) and “Capillary Enzyme-Linked Immunosorbent Assay (ELISA)” for High Sensitivity and Fast Assays
Using gold nanoparticles (AuNPs) on “capillary enzyme-linked immunosorbent assay (ELISA)”, we produced highly sensitive and rapid assays, which are the major attributes for point-of-care applications. First, in order to understand the size effect of AuNPs, AuNPs of varying diameters (5 nm, 10 nm, 15 nm, 20 nm, 30 nm, and 50 nm) conjugated with Horseradish Peroxidase (HRP)-labeled anti-C reactive protein (antiCRP) (AuNP•antiCRP-HRP) were used for well-plate ELISA. AuNP of 10 nm produced the largest optical density, enabling detection of 0.1 ng/mL of CRP with only 30 s of incubation, in contrast to 10 ng/mL for the ELISA run in the absence of AuNP. Then, AuNP of 10 nm conjugated with antiCRP-HRP (AuNP•antiCRP-HRP) was used for “capillary ELISA” to detect as low as 0.1 ng/mL of CRP. Also, kinetic study on both 96-well plates and in a capillary tube using antiCRP-HRP or AuNP•antiCRP-HRP showed a synergistic effect between AuNP and the capillary system, in which the fastest assay was observed from the “AuNP capillary ELISA”, with its maximum absorbance reaching 2.5 min, while the slowest was the typical well-plate ELISA with its maximum absorbance reaching in 13.5 min.
Open AccessSynergistic Use of Gold Nanoparticles (AuNPs) and “Capillary Enzyme-Linked Immunosorbent Assay (ELISA)” for High Sensitivity and Fast Assays
Using gold nanoparticles (AuNPs) on “capillary enzyme-linked immunosorbent assay (ELISA)”, we produced highly sensitive and rapid assays, which are the major attributes for point-of-care applications. First, in order to understand the size effect of AuNPs, AuNPs of varying diameters (5 nm, 10 nm, 15 nm, 20 nm, 30 nm, and 50 nm) conjugated with Horseradish Peroxidase (HRP)-labeled anti-C reactive protein (antiCRP) (AuNP•antiCRP-HRP) were used for well-plate ELISA. AuNP of 10 nm produced the largest optical density, enabling detection of 0.1 ng/mL of CRP with only 30 s of incubation, in contrast to 10 ng/mL for the ELISA run in the absence of AuNP. Then, AuNP of 10 nm conjugated with antiCRP-HRP (AuNP•antiCRP-HRP) was used for “capillary ELISA” to detect as low as 0.1 ng/mL of CRP. Also, kinetic study on both 96-well plates and in a capillary tube using antiCRP-HRP or AuNP•antiCRP-HRP showed a synergistic effect between AuNP and the capillary system, in which the fastest assay was observed from the “AuNP capillary ELISA”, with its maximum absorbance reaching 2.5 min, while the slowest was the typical well-plate ELISA with its maximum absorbance reaching in 13.5 min.
- 1 May 2017
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 91, 637-643
Femtomolar detection of cardiac troponin I using a novel label-free and reagent-free dendrimer enhanced impedimetric immunosensor
- 1 May 2017
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 91, 637-643
Femtomolar detection of cardiac troponin I using a novel label-free and reagent-free dendrimer enhanced impedimetric immunosensor
- 15 July 2015
- Published by Wiley in Electroanalysis
- Vol. 27 (11) , 2588-2595
Highly Sensitive Voltammetric Thrombin Aptamer Sensor Based on the Synergistic Effect of Doping/Depositing Gold Nanoparticles in Polydopamine Film
A highly sensitive square‐wave voltammetric thrombin (TB) aptamer sensor was developed using functional polydopamine (PD) film by doping and depositing gold nanoparticles into the bulk and the surface of PD. The aptamer sensor was fabricated by immobilizing a thiolated TB‐binding aptamer (TBA) on the AuNPs‐doped/deposited PD film. AuNPs‐supported methylene blue labels were used for the detection of human α‐TB. Under the optimized conditions, the aptamer sensor’s dynamic range and the detection limit were determined to be 2.0 pM–50 nM and 0.97±0.06 pM, respectively. Finally, the proposed aptamer sensor was successfully examined in human serum samples and satisfactory results were obtained.
- 15 July 2015
- Published by Wiley in Electroanalysis
- Vol. 27 (11) , 2588-2595
Highly Sensitive Voltammetric Thrombin Aptamer Sensor Based on the Synergistic Effect of Doping/Depositing Gold Nanoparticles in Polydopamine Film
A highly sensitive square‐wave voltammetric thrombin (TB) aptamer sensor was developed using functional polydopamine (PD) film by doping and depositing gold nanoparticles into the bulk and the surface of PD. The aptamer sensor was fabricated by immobilizing a thiolated TB‐binding aptamer (TBA) on the AuNPs‐doped/deposited PD film. AuNPs‐supported methylene blue labels were used for the detection of human α‐TB. Under the optimized conditions, the aptamer sensor’s dynamic range and the detection limit were determined to be 2.0 pM–50 nM and 0.97±0.06 pM, respectively. Finally, the proposed aptamer sensor was successfully examined in human serum samples and satisfactory results were obtained.