ESErin D. Sheets

Erin D. Sheets

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Erin D. Sheets has a total of 69 co-authors. Here are the top co-authors by number of shared publications:

  • Ahmed A. Heikal

    Department of Chemistry and Biochemistry, Swenson College of Science and Engineering, University of Minnesota Duluth, Duluth, MN 55812, USA

    10 shared publications
  • Arnold J. Boersma

    Bijvoet Centre for Biomolecular Research, Utrecht University

    9 shared publications
  • Ahmed A. Heikal

    Univ. of Minnesota, Duluth (United States)

    5 shared publications
  • Barbara Baird

    Materials Science and Engineering, Cornell University, Ithaca, New York 14853, Department of Materials, University of California at Santa Barbara, Santa Barbara, California 93106, Chemistry and Chemical Biology, Cornell University, Ithaca, New York 14853, Cornell Nanofabrication Facility, Cornell University, Ithaca, New York 14853, and Cornell Nanobiotechnology Center, Cornell University, Ithaca, New York 14853

    4 shared publications
  • David Holowka

    Department of Chemistry and Chemical Biology, Cornell University, Ithaca, NY 14853-1301, USA

    4 shared publications
  • Ryan Leighton

    4 shared publications

Latest Publications

  • Translational diffusion, molecular brightness, and energy transfer analysis of mEGFP-linker-mScarlet–I crowding biosensor using fluorescence correlation spectroscopy

    by Sarah A. Mersch, Clint McCue, Alexandros Aristidou, Erin D. Sheets, Arnold J. Boersma, Ahmed A. Heikal

    Recently, we have investigated the sensitivity of an mEGFP-linker-mScarlet-I construct (GE2.3) in response to macromolecular crowding using ensemble time-resolved two-photon (2P) fluorescence measurements [Mersch et al., Phys. Chem. Chem. Phys. 2024, 26(5), 3927–3940] as a point of reference for developing a single-molecule approach for Förster resonance energy transfer (FRET). Here, we investigate the fluorescence fluctuations, FRET, molecular brightness, and translational diffusion of GE2.3 as a model system using fluorescence correlation spectroscopy (FCS), at the single molecule level, as a function of the excitation and detection wavelengths of the donor (mEGFP) and the acceptor (mScarlet-I). We hypothesize that the molecular brightness (number of fluorescence photons per molecule) of the donor of GE2.3, in the presence and absence of the acceptor, would be distinct due to FRET at the single-molecule level. To test this hypothesis, we used wavelength-dependent FCS to quantify the molecular brightness of intact and enzymatically cleaved GE2.3 as a function of Ficoll-70 (a crowding agent, 0–300 g L−1) at room temperature. Our results indicate that the molecular brightness of intact GE2.3 in a buffer is smaller than that of the cleaved counterpart under 488-nm excitation of the donor, which is attributed to FRET. In contrast, the molecular brightness of both cleaved and intact GE2.3 seems to be the same under the 561-nm excitation of the acceptor due to the absence of FRET. Our results also show that the FRET efficiency of GE2.3 increases as the concentration of Ficoll increases up to 200 g L−1, which agrees with our previous time-resolved 2P-fluorescence measurements. Fluctuation autocorrelation analysis shows that the translational diffusion of intact and cleaved GE2.3 sensors deviates from the Stokes–Einstein model in Ficoll crowded solutions. Additionally, we highlight the multiscale translational and rotational diffusion coefficients of GE2.3 in terms of the average distance between neighboring Ficoll molecules, over the same concentration range, to elucidate the spatio-temporal scaling aspect of FRET and protein–protein interactions. These single-molecule studies would be beneficial for future studies in living cells, where very low GE2.3 expression levels will be required as compared with ensemble, time-resolved 2P-fluorescence measurements.


  • Open Access

    Two-photon excited-state dynamics of mEGFP-linker-mScarlet-I crowding biosensor in controlled environments

    by Sarah A. Mersch, Sarah Bergman, Erin D. Sheets, Arnold J. Boersma, Ahmed A. Heikal

    Macromolecular crowding affects many cellular processes such as diffusion, biochemical reaction kinetics, protein–protein interactions, and protein folding. Mapping the heterogeneous, dynamic crowding in living cells or tissues requires genetically encoded, site-specific, crowding sensors that are compatible with quantitative, noninvasive fluorescence micro-spectroscopy. Here, we carried out time-resolved 2P-fluorescence measurements of a new mEGFP-linker-mScarlet-I macromolecular crowding construct (GE2.3) to characterize its environmental sensitivity in biomimetic crowded solutions (Ficoll-70, 0–300 g L−1) via Förster resonance energy transfer (FRET) analysis. The 2P-fluorescence lifetime of the donor (mEGFP) was measured under magic-angle polarization, in the presence (intact) and absence (enzymatically cleaved) of the acceptor (mScarlet-I), as a function of the Ficoll-70 concentration. The FRET efficiency was used to quantify the sensitivity of GE2.3 to macromolecular crowding and to determine the environmental dependence of the mEGFP-mScarlet-I distance. We also carried out time-resolved 2P-fluorescence depolarization anisotropy to examine both macromolecular crowding and linker flexibility effects on GE2.3 rotational dynamics within the context of the Stokes–Einstein model as compared with theoretical predictions based on its molecular weight. These time-resolved 2P-fluorescence depolarization measurements and conformational population analyses of GE2.3 were also used to estimate the free energy gain upon the structural collapse in crowded environment. Our results further the development of a rational engineering design for bioenvironmental sensors without the interference of cellular autofluorescence. Additionally, these results in well-defined environments will inform our future in vivo studies of genetically encoded GE2.3 towards the mapping of the crowded intracellular environment under different physiological conditions.


  • Conformational equilibrium analysis of mCerulean3–linker–mCitrine constructs using time-resolved fluorescence measurements in controlled environments

    by Clint McCue, Sarah A. Mersch, Sarah Bergman, Erin D. Sheets, Ahmed A. Heikal

    Macromolecular crowding and ionic strength in living cells influence a myriad of biochemical processes essential to cell function and survival. For example, macromolecular crowding is known to affect diffusion, biochemical reaction kinetics, protein folding, and protein-protein interactions. In addition, enzymatic activities, protein folding, and cellular osmosis are also sensitive to environmental ionic strength. Recently, genetically encoded mCerulean3-linker-mCitrine constructs have been developed and characterized using time-resolved fluorescence measurements as a function of the amino acid sequence of the linker region as well as the environmental crowding and ionic strength. Here, we investigate the thermodynamic equilibrium of structural conformations of mCerulean3-linker-mCitrine constructs in response to the environmental macromolecular crowding and ionic strength. We have developed a theoretical framework for thermodynamic equilibrium of the structural conformations of these environmental sensors. In addition, we tested these theoretical models for thermodynamic analysis of these donor-linker-acceptor sensors using time-resolved fluorescence measurements as a function of the amino acid sequence of the linker region. Employing ultrafast time-resolved fluorescence measurements for gaining thermodynamic energetics would be helpful for Förster Resonance Energy Transfer (FRET) studies of protein-protein interactions in both living cells and controlled environments.


  • Fluorescence depolarization dynamics of ionic strength sensors using time-resolved anisotropy

    by Cody P. Aplin, Robert C. Miller, Taryn M. Kay, Ahmed A. Heikal, Arnold J. Boersma, Erin D. Sheets


  • Correction to “FRET Analysis of Ionic Strength Sensors in the Hofmeister Series of Salt Solutions Using Fluorescence Lifetime Measurements”

    by Robert C. Miller, Cody P. Aplin, Taryn M. Kay, Ryan Leighton, Christin Libal, Rowan Simonet, Alessandro Cembran, Ahmed A. Heikal, Arnold J. Boersma, Erin D. Sheets


  • FRET Analysis of Ionic Strength Sensors in the Hofmeister Series of Salt Solutions Using Fluorescence Lifetime Measurements

    by Robert C. Miller, Cody P. Aplin, Taryn M. Kay, Ryan Leighton, Christin Libal, Rowan Simonet, Alessandro Cembran, Ahmed A. Heikal, Arnold J. Boersma, Erin D. Sheets

    Living cells are complex, crowded, and dynamic and continually respond to environmental and intracellular stimuli. They also have heterogeneous ionic strength with compartmentalized variations in both intracellular concentrations and types of ions. These challenges would benefit from the development of quantitative, noninvasive approaches for mapping the heterogeneous ionic strength fluctuations in living cells. Here, we investigated a class of recently developed ionic strength sensors that consists of mCerulean3 (a cyan fluorescent protein) and mCitrine (a yellow fluorescent protein) tethered via a linker made of two charged -helices and a flexible loop. The two helices are designed to bear opposite charges, which is hypothesized to increase the ionic screening and therefore a larger intermolecular distance. In these protein constructs, mCerulean3 and mCitrine act as a donor-acceptor pair undergoing Fӧrster resonance energy transfer (FRET) that is dependent on both the linker amino acids and the environmental ionic strength. Using time-resolved fluorescence of the donor (mCerulean3), we determined the sensitivity of the energy transfer efficiencies and the donor-acceptor distances of these sensors at variable concentrations of the Hofmeister series of salts (KCl, LiCl, NaCl, NaBr, NaI, Na2SO4). As controls, similar measurements were carried out on the FRET-incapable, enzymatically cleaved counterparts of these sensors as well as a construct designed with two electrostatically neutral -helices (E6G2). Our results show that the energy transfer efficiencies of these sensors are sensitive to both the linker amino acid sequence and the environmental ionic strength, whereas the sensitivity of these sensors to the identity of the dissolved ions of the Hofmeister series of salts seems limited. We also developed a theoretical framework to explain the observed trends as a function of the ionic strength in terms of the Debye screening of the electrostatic interaction between the two charged -helices in the linker region. These controlled solution studies represent an important step towards the development of rationally designed FRET-based environmental sensors while offering different models for calculating the energy transfer efficiency using time-resolved fluorescence that is compatible with future in vivo studies.


  • Macromolecular crowding effects on energy transfer efficiency and donor-acceptor distance of hetero-FRET sensors using time-resolved fluorescence

    by Jacob Schwarz, Hannah J. Leopold, Ryan Leighton, Robert C. Miller, Cody P. Aplin, Arnold J Boersma, Ahmed A Heikal, Erin D. Sheets

    Living cells are crowded with macromolecules and organelles, which affect a myriad of biochemical processes. As a result, there is a need for sensitive molecular sensors for quantitative, site-specific assessment of macromolecular crowding. Here, we investigated the excited-state dynamics of recently developed hetero-FRET sensors (mCerulean3–linker–mCitrine) in homogeneous and heterogeneous environments using time-resolved fluorescence measurements, which are compatible with fluorescence lifetime imaging microscopy (FLIM). The linker in these FRET constructs, which tether the mCerulean3 (the donor) and mCitrine (the acceptor), vary in both length and flexibility. Glycerol and Ficoll-70 solutions were used for homogeneous and heterogeneous environments, respectively, at variable concentrations. The wavelength-dependent studies suggest that the 425-nm excitation and the 475-nm emission of the donor are best suited for quantitative assessment of the energy transfer efficiency and the donor-acceptor distance of these FRET probes. Under the same experimental conditions, the enzymatically cleaved counterpart of these probes was used as a control as well as a means to account for the changes in the environmental refractive indices. Our results indicate that the energy transfer efficiency of these FRET probes increases as the linker becomes shorter and more flexible in pure buffer at room temperature. In addition, the FRET probes favor a compact structure with enhanced energy transfer efficiency and a shorter donor-acceptor distance in the heterogeneous, polymer-crowded environment due to steric hindrance. In contrast, the stretched conformation of these FRET probes is more favorable in the viscous, homogeneous environment with a reduced energy transfer efficiency and relatively larger donor-acceptor distance as compared with those in pure buffer, which was attributed to a reduced structural fluctuation of the mCerulean3–mCitrine FRET pair in the viscous, more restrictive glycerol-enriched buffer. Our findings will help to advance the potential of these hetero-FRET probes using FLIM for spatio-temporal assessment of the compartmentalized crowding in living cells.


  • Crowding Effects on Energy-Transfer Efficiencies of Hetero-FRET Probes As Measured Using Time-Resolved Fluorescence Anisotropy

    by Hannah J. Leopold, Ryan Leighton, Jacob Schwarz, Arnold J. Boersma, Erin D. Sheets, Ahmed A. Heikal

    Macromolecular crowding is prevalent in all living cells due to the presence of large biomolecules and organelles. Cellular crowding is heterogeneous and is known to influence biomolecular transport, biochemical reactions, and protein folding. Emerging evidence suggests that some cell pathologies may be correlated with compartmentalized crowding. As a result, there is a need for robust biosensors that are sensitive to crowding as well as quantitative, non-invasive fluorescence methods that are compatible with living cells studies. Here, we have developed a model that describes the rotational dynamics of hetero-FRET biosensors as a means to determine the energy transfer efficiency and donor-acceptor distance. The model was tested on wavelength-dependent time-resolved fluorescence anisotropy of hetero-FRET probes (mCerulean3–linker–mCitrine) with variable linkers in both heterogeneous (Ficoll-70) and homogeneous (glycerol) solutions at room temperature. Our results indicate that the energy transfer efficiency of these FRET probes increases as the linker becomes shorter and more flexible in pure buffer at room temperature. In addition, the FRET probes favor a compact structure with enhanced energy transfer efficiency and a shorter donor-acceptor distance in the heterogeneous, polymer-crowded environment due to steric hindrance. In contrast, the extended conformation of these FRET probes is more favorable in a viscous, homogeneous environment with a reduced energy transfer efficiency as compared with those in pure buffer, which was attributed to reduced structural fluctuations of the mCerulean3–mCitrine FRET pair in the glycerol-enriched buffer. Our results represent an important step towards the application of quantitative and non-invasive time-resolved fluorescence anisotropy of hetero-FRET probes to investigate compartmentalized macromolecular crowding and protein-protein interactions in living cells as well as in controlled environments.


  • Rotational and translational diffusion of size-dependent fluorescent probes in homogeneous and heterogeneous environments

    by Hong Bok Lee, Anh Cong, Hannah Leopold, Megan Currie, Arnold J. Boersma, Erin D. Sheets, Ahmed A. Heikal

    Macromolecular crowding effects on diffusion depend on the fluorophore structure, the concentration of crowding agents, and the technique employed.


  • Fluorescence Dynamics of a FRET Probe Designed for Crowding Studies

    by Megan Currie, Hannah Leopold, Jacob Schwarz, Arnold J. Boersma, Erin D. Sheets, Ahmed A. Heikal

    Living cells are crowded with macromolecules and organelles. As a result, there is an urgent need for molecular sensors for quantitative, site-specific assessment of the macromolecular crowding effects on a myriad of biochemical processes toward quantitative cell biology and biophysics. Here we investigate the excited-state dynamics and translational diffusion of a novel FRET sensor (mCerulean–linker–mCitrine) in a buffer (PBS, pH 7.4) at room temperature. Complementary experiments were carried out on free CFP, YFP, and the cleaved FRET probe as controls. The wavelength-dependent fluorescence lifetime measurements of the donor and acceptor in the FRET probe, using the time-correlated single-photon counting technique, indicate an energy transfer efficiency of 6.8 ± 0.9% in PBS, with distinct excited-state dynamics from the recombinant CFP and YFP. The estimated mCerulean—mCitrine distance in this FRET probe is 7.7 ± 0.2 nm. The energy transfer efficiency increases (11.5 ± 0.9%) as the concentration of Ficoll-70 increases over the range of 0–300 g/L with an estimated mCerulean–mCitrine distance of 6.1 ± 0.2 nm. Complementary time-resolved anisotropy measurements suggest that the rotational diffusion of hetero-FRET in PBS is sensitive to the energy transfer from the donor to the acceptor. The results also suggest that the linker, −(GSG)6A(EAAAK)6A(GSG)6A(EAAAK)6A(GSG)6–, is rather flexible, and the observed rotational dynamics is likely to be due to a segmental mobility of the FRET pairs rather than an overall tumbling motion of a rigid probe. Comparative studies on a new construct of a FRET probe with a shorter, more flexible linker, mCerulean–(GSG)18–mCitrine, reveal enhanced energy transfer efficiency. On the millisecond time scale, fluorescence fluctuation analyses of the acceptor (excited at 488 nm) provide a means to examine the translational diffusion coefficient of the FRET probe. The results also suggest that the linker is flexible in this FRET probe, and the observed diffusion coefficient is faster than predicted as compared to the cleaved FRET probe. Our results serve as a point of reference for this FRET probe in a buffer toward its full potential as a sensor for macromolecular crowding in living cells and tissues.