Adel Tabakhpour Langerudy has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Andrea Mariscotti
Department of Electrical, Electronic and Telecommunications Engineering, and Naval Architecture (DITEN), University of Genova, 16145 Genova, Italy
2 shared publications - Morad Mohamed Abdelmageed Abdelaziz
University of British Columbia, Kelowna, BC, Canada
2 shared publications - Sayed Mohammad Mousavi Gazafroudi
School of Railway Engineering, Iran University of Science and Technology, Tehran 13114-16846, Iran
2 shared publications Ewald F. Fuchs
1 shared publicationKamal Al-Haddad
1 shared publicationMohammad A. Abolhassani
Department of Electrical and Computer Engineering, Tarbiat Modares University, Tehran, Iran
1 shared publication
Latest Publications
- Open Access
- 10 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 40823-40835
Integration of Failure Detector in Bias Filter for Estimation of False Data Injection Cyberattacks
In order to enable many of the required smart grid functionalities, distribution systems are becoming increasingly dependent on state estimators. Many cyber-attacks attempt false data injection (FDI) attacks on such state estimators. The majority of the existing literature deal with FDIs in distribution systems state estimation either by the analysis of the residual vector elements, or by the analysis of historical data. In this work, we adopt an alternative approach for the detection of FDIs in distribution system state estimation, wherein FDIs are modelled as measurement biases and a bias filter is employed for FDI detection. Additionally, in order to enable the detection of time-variable FDIs, a failure detector is integrated in the recursive formulation of the bias filter, which is based on the Kalman filter. The developed approach is accordingly capable of identifying time-varying FDIs, which can evade many of the existing FDI detection methods. Simulation case studies are performed on the IEEE 13-node and 123-node feeders with different FDIs and the performance of the proposed approach is analyzed.
- 10 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 40823-40835
Open AccessIntegration of Failure Detector in Bias Filter for Estimation of False Data Injection Cyberattacks
In order to enable many of the required smart grid functionalities, distribution systems are becoming increasingly dependent on state estimators. Many cyber-attacks attempt false data injection (FDI) attacks on such state estimators. The majority of the existing literature deal with FDIs in distribution systems state estimation either by the analysis of the residual vector elements, or by the analysis of historical data. In this work, we adopt an alternative approach for the detection of FDIs in distribution system state estimation, wherein FDIs are modelled as measurement biases and a bias filter is employed for FDI detection. Additionally, in order to enable the detection of time-variable FDIs, a failure detector is integrated in the recursive formulation of the bias filter, which is based on the Kalman filter. The developed approach is accordingly capable of identifying time-varying FDIs, which can evade many of the existing FDI detection methods. Simulation case studies are performed on the IEEE 13-node and 123-node feeders with different FDIs and the performance of the proposed approach is analyzed.
- 1 September 2020
- Published by Elsevier in Electric Power Systems Research
- Vol. 186
Preventative high impedance fault detection using distribution system state estimation
- 1 September 2020
- Published by Elsevier in Electric Power Systems Research
- Vol. 186
Preventative high impedance fault detection using distribution system state estimation
- 1 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Enhanced Bad Data Identification in Distribution System State Estimation
State estimation is an important tool in monitoring and controlling active distribution systems. An important partner of estimation is bad data identification, which could effectively improve the estimation's precision in the cases where bad data exists in the measurement set. Once the measurement set is detected to include bad data, its spot must be identified to be excluded from the estimation problem. It is well known that the biggest value of residual vector is most likely corresponding to the bad data. This paper proposes a new estimation algorithm, which enhances the influence of the bad data in the residual vector, increasing the possibility of the successful bad data identification based only on residual vector.
- 1 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Enhanced Bad Data Identification in Distribution System State Estimation
State estimation is an important tool in monitoring and controlling active distribution systems. An important partner of estimation is bad data identification, which could effectively improve the estimation's precision in the cases where bad data exists in the measurement set. Once the measurement set is detected to include bad data, its spot must be identified to be excluded from the estimation problem. It is well known that the biggest value of residual vector is most likely corresponding to the bad data. This paper proposes a new estimation algorithm, which enhances the influence of the bad data in the residual vector, increasing the possibility of the successful bad data identification based only on residual vector.
- 31 January 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Vehicular Technology
- Vol. 66 (8) , 6653-6662
Power Quality Conditioning in Railway Electrification: A Comparative Study
Electric transportation systems are a challenging load for three-phase transmission lines due to load variations, reactive power, imbalance, and harmonic pollution. Many power quality conditioners and compensation technologies have been developed to ensure compatibility with power systems. The most important ones are investigated, identifying parameters and performances for comparison, including evaluation of cost and size. A reference case is used for simulation, focusing on three-phase current intensity, current rate of rise, dc-link voltage, and dynamic response under various combinations of traction line load. The objective is to identify key characteristics supporting the selection of the appropriate compensation strategy for a new electrified railway system.
- 31 January 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Vehicular Technology
- Vol. 66 (8) , 6653-6662
Power Quality Conditioning in Railway Electrification: A Comparative Study
Electric transportation systems are a challenging load for three-phase transmission lines due to load variations, reactive power, imbalance, and harmonic pollution. Many power quality conditioners and compensation technologies have been developed to ensure compatibility with power systems. The most important ones are investigated, identifying parameters and performances for comparison, including evaluation of cost and size. A reference case is used for simulation, focusing on three-phase current intensity, current rate of rise, dc-link voltage, and dynamic response under various combinations of traction line load. The objective is to identify key characteristics supporting the selection of the appropriate compensation strategy for a new electrified railway system.
- Open Access
- 1 September 2016
- Published by Institution of Engineering and Technology (IET) in IET Electrical Systems in Transportation
- Vol. 6 (3) , 207-214
Hybrid railway power quality conditioner for high‐capacity traction substation with auto‐tuned DC‐link controller
Power quality was always a major concern in designing an electric supply system for railways. Since electric railcars are usually single‐phase loads, they draw high amounts of negative sequence component of currents, in addition to harmonic contents and transient currents. Therefore, many compensation methods were examined to improve the power quality indices. The active power quality conditioner (APQC) can be considered as an ideal compensator for high‐speed railway, which contains a three‐phase converter connected to the traction substation through a step‐down transformer. However, with the growth of railway loads, the nominal rating of the solid‐state high‐frequency switches of APQC increases seriously, which in turn, results in an exponential growth of the cost of power‐electronic switches. Therefore, for a very high‐capacity railway system, it is not economic to apply an APQC. As a solution, a combination of APQC with the static VAr compensator is proposed in this study, which reduces the rating of APQC, and improves the power quality of the system. Simulation results validate the pre‐defined hypothesis. Moreover, the performance of APQC depends on the DC‐link operation, for which genetic‐algorithm optimisation has been applied to obtain an optimum design of a stable DC‐link voltage.
- 1 September 2016
- Published by Institution of Engineering and Technology (IET) in IET Electrical Systems in Transportation
- Vol. 6 (3) , 207-214
Open AccessHybrid railway power quality conditioner for high‐capacity traction substation with auto‐tuned DC‐link controller
Power quality was always a major concern in designing an electric supply system for railways. Since electric railcars are usually single‐phase loads, they draw high amounts of negative sequence component of currents, in addition to harmonic contents and transient currents. Therefore, many compensation methods were examined to improve the power quality indices. The active power quality conditioner (APQC) can be considered as an ideal compensator for high‐speed railway, which contains a three‐phase converter connected to the traction substation through a step‐down transformer. However, with the growth of railway loads, the nominal rating of the solid‐state high‐frequency switches of APQC increases seriously, which in turn, results in an exponential growth of the cost of power‐electronic switches. Therefore, for a very high‐capacity railway system, it is not economic to apply an APQC. As a solution, a combination of APQC with the static VAr compensator is proposed in this study, which reduces the rating of APQC, and improves the power quality of the system. Simulation results validate the pre‐defined hypothesis. Moreover, the performance of APQC depends on the DC‐link operation, for which genetic‐algorithm optimisation has been applied to obtain an optimum design of a stable DC‐link voltage.
- 1 April 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 27, 1-7
Tuning of a railway power quality conditioner
Railway power conditioners are widely adopted to improve Power Quality of electric railways. The present study focuses on the main architectures and the simplest, but effective, control method (PI controller): DC-link voltage and output current sequence are the controlled quantities and optimization is reached iteratively, showing the consequences of each choice. The final objective is to identify criteria that may be applied equally well to different compensator topologies.
- 1 April 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 27, 1-7
Tuning of a railway power quality conditioner
Railway power conditioners are widely adopted to improve Power Quality of electric railways. The present study focuses on the main architectures and the simplest, but effective, control method (PI controller): DC-link voltage and output current sequence are the controlled quantities and optimization is reached iteratively, showing the consequences of each choice. The final objective is to identify criteria that may be applied equally well to different compensator topologies.
- Top Cited Papers
- 31 December 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 62 (5) , 3081-3090
Power Quality Issues in Railway Electrification: A Comprehensive Perspective
Since the beginning of railway electrification, power quality has been a main problem in railway networks because of their special characteristics. Many ways of power quality improvement have been investigated and applied to ac and dc traction systems through railway electrification history. This paper presents a perspective on power quality issues through railway electrification development and investigates the necessity of power quality and system requirements for appropriate power quality. Compensation strategies are classified and compared. This aims to provide a comprehensive perspective of the power quality issue in railway power/distribution networks for researchers and engineers working on railway electrification. Less than 100 research articles are referenced for researchers to obtain good background information.
- 31 December 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 62 (5) , 3081-3090
Top Cited PapersPower Quality Issues in Railway Electrification: A Comprehensive Perspective
Since the beginning of railway electrification, power quality has been a main problem in railway networks because of their special characteristics. Many ways of power quality improvement have been investigated and applied to ac and dc traction systems through railway electrification history. This paper presents a perspective on power quality issues through railway electrification development and investigates the necessity of power quality and system requirements for appropriate power quality. Compensation strategies are classified and compared. This aims to provide a comprehensive perspective of the power quality issue in railway power/distribution networks for researchers and engineers working on railway electrification. Less than 100 research articles are referenced for researchers to obtain good background information.