SASarab Al-Chlaihawi

Sarab Al-Chlaihawi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Sarab Al-Chlaihawi has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    TCM-Former: a transformer with temporal convolution for photovoltaic power forecasting

    by Sarab Al-Chlaihawi, Mohammed A. T. Alrubei, Faris A. Alhaddad

    To tackle the problem of modeling long-term trends and short-term and high-frequency variations in PV time series, a strong and efficient forecasting model of photovoltaic (PV) power generation is advanced. This paper presents STL-TCM-Former, a hybrid model that breaks down the raw PV signal with seasonal-trend decomposition with LOESS (STL) into trend and seasonal components. These elements are after that processed via a dual path encoder decoder transformer architecture that is improved with a temporal convolutional module (TCM). The period (transformer-based) path is used for capturing the global, long-range dependencies in seasonal component and temporal (TCM) path is used to extract the localized, short-term dynamics. Trend component is processed with a dedicated TCM branch, minimizing component interferences and providing a multiscale temporal representation, specific to PV generation patterns. The proposed model was evaluated on the Yulara (Uluru) solar dataset under short-term (60-hour) and long-term (300-hour) forecasting horizons. Compared with benchmark models including LSTM, WOA-LSTM, VMD-LSTM, WOA-VMD-LSTM, and hybrid WOA/VMD/LSTM configurations, STL-TCM-former achieved superior performance with R² = 99.76%, MAPE ≈ 2.24%, RMSE = 16.63, and MAE = 10.36. In addition, the PJM interconnection dataset was also employed to evaluate the generalization capability of the proposed method. The results demonstrate high accuracy, stability, and strong generalization capability under varying environmental conditions.

  • Open Access

    Maximum power point tracking based upon expert systems in standalone photovoltaic system

    by Sarab Al-Chlaihawi, Ashwaq N. Hassan

    Maximum Power Point Tracking (MPPT) can be defined as the most efficient way to get the most power out of a photovoltaic device. Under any environmental scenario, the fuzzy logic controller algorithm will excellently monitor the full power operating point. The implementation of the fuzzy logic algorithm for the MPPT charge controller is defined in this paper this paper describes how to use a Particle swarm optimization - fuzzy logic algorithm to incorporate an MPPT charge controller to get the most peak power out of a photovoltaic device. The boost converter uses the Fuzzy Algorithm to transform the PV panel voltage to a fixed level where the PV panel's full peak power can be collected. The high rating current is converted into a particular voltage spectrum by a DC/DC converter. The PV panel's peak DC power is then used to charge the DC battery. Simulink is used to demonstrate the simulation result (MATLAB).

  • Open Access

    Artificial intelligence techniques over the fifth generation mobile networks: a review

    by Ashwaq N. Hassan, Sarab Al-Chlaihawi, Ahlam R. Khekan

    A well Fifth generation (5G) mobile networks have been a common phrase in recent years. We have all heard this phrase and know its importance. By 2025, the number of devices based on the fifth generation of mobile networks will reach about 100 billion devices. By then, about 2.5 billion users are expected to consume more than a gigabyte of streamed data per month. 5G will play important roles in a variety of new areas, from smart homes and cars to smart cities, virtual reality and mobile augmented reality, and 4K video streaming. Bandwidth much higher than the fourth generation, more reliability and less latency are some of the features that distinguish this generation of mobile networks from previous generations. Clearly, at first glance, these features may seem very impressive and useful to a mobile network, but these features will pose serious challenges for operators and communications companies. All of these features will lead to considerable complexity. Managing this network, preventing errors, and minimizing latency are some of the challenges that the 5th generation of mobile networks will bring. Therefore, the use of artificial intelligence and machine learning is a good way to solve these challenges. in other say, in such a situation, proper management of the 5G network must be done using powerful tools such as artificial intelligence. Various researches in this field are currently being carried out. Research that enables automated management and servicing and reduces human error as much as possible. In this paper, we will review the artificial intelligence techniques used in communications networks. Creating a robust and efficient communications network using artificial intelligence techniques is a great incentive for future research. The importance of this issue is such that the sixth generation (6G) of cellular communications; There is a lot of emphasis on the use of artificial intelligence.


  • Open Access

    Experimental installation of wireless power transfer system based on the series resonance technology

    by Sarab Al-Chlaihawi, Adnan Hasan Tawafan, Fatima Kadhem Abd

    In this work, we aim to install a wireless power transfer (WPT) system experimentally. Series resonance technology was used to achieve zero-voltage switching (ZVS). We investigated the impact of the primary and secondary resonance frequencies (fp and fd), and inverter frequency switching (fch) on the efficiency (β) and maximum transfer power in a WPT system based on the inductive wireless power transfer (IWPT) technology. An ultrasonic device was utilized as a generator to excite the coil at the primary side. The experimental outcomes showed that there is an optimum unlike fp and fd can be got to match fch. It was found also that there is a trade-off between the power supplied to the load (PRL) and DC-DC efficiency (β). At an air-gap of 5 cm, the obtained results are recorded as follows; the peak recorded system β is 62% that was obtained at fp=19 kHz, fd=fch=24 kHz that is corresponding to 101.88W of PRL; whereas the highest PRL resulted i.e. 244W when fp=19 kHz, fd =24 kHz, fch=21 kHz at 61% of β; in such case, the maximum β* PRL multiplication was achieved i.e. 149. Moreover, the coils’ misalignment was studied. The outcomes showed that the lateral misalignment has worst effect on the PRL and β than the air-gap. The experimental results were validated with simulation ones.


  • Open Access

    Fuzzy Logic Power Flow Control in divide Full Bridge Three-Port Converter

    by Sarab Al-Chlaihawi, Mohammed A. T. Alrubei, Ammar Al-Gizi, Mohammed Al-Saadi, Mohamed Louzazni

    On this work, the three-port converter derivative from the full-bridge converter is analysed and control. The full-bridge converter is made up of two parts, A and B. Each part contains two switches with independent input sources. The inputs drive the load through a transformer that boosts voltage and provides isolation. The controller is an important portion of the converter. It controls the pass of power between the three ports. The controller uses Fuzzy Logic Control to make decisions regarding the two control signals for each part. These decisions are based on the variance between the whole energy generated by the photovoltaic panel and the energy demand at the load. The proposed design is verified through MATLAB and Simulink.


  • A New Analytical Formula for Coupling Capacitance of Unipolar Capacitive Coupler in Wireless Power Transfer System

    by Mohammed Al-Saadi, Sarab Al-Chlaihawi, Mustafa Al-Qaisi, Aurelian Craciunescu

    In this research, using response surface methodology (RSM), an analytical formula as functional dependencies on the six specified geometrical parameters is developed for coupling capacitance (C m ) of a capacitive power transfer (CPT) device. The geometrical parameters include the physical and misalignment parameters of the plates. Using the variance analysis, the sensitivity of the C m value to variations in the geometric parameters of the CPT device was investigated. The established analytical formula allows for easy calculation of the C m value specific to the CPT devices for their different geometric parameters, including for different misalignments. It is also particularly useful in optimal design of the CPT devices. However, it was found that the misalignment parameters have a negligible effect on the C m . On the other hand, the physical parameters have an effect of 46%, 38%, and 16% for the transmitter plate area, receiver plate area, and air-gap between them, respectively.


  • Open Access

    Analysis of Charge Plate Configurations in Unipolar Capacitive Power Transfer System for the Electric Vehicles Batteries Charging

    by Mohammed Al-Saadi, Ammar Al-Gizi, Sadiq Ahmed, Sarab Al-Chlaihawi, Aurelian Craciunescu


  • Experimental Installation of Photovoltaic MPPT Controller Using Arduino Board

    by Ammar Al-Gizi, Mohammed Al-Saadi, Sarab Al-Chlaihawi, Aurelian Craciunescu, Mustafa Abbas Fadel

    Nowadays, several electronic devices as field programmable gate arrays (FPGA) and dSPACE controllers are used to implement the maximum power point tracking (MPPT) for the photovoltaic (PV) systems applications. In contrast, the PIC microcontrollers are recommended to be used due to its low cost and simplicity compared with the other hardware devices. In this paper, the Arduino microcontroller is used to validate the function of perturb and observe (P&O) MPPT controller used with a stand-alone PV system under constant climate conditions and step variations in the connected load. From the comparison of experimental and simulation results, the available maximum power of the solar panel is successfully extracted by using Arduino Uno board irrespective of the variable load conditions.