Beat Jeckelmann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Beat Jeckelmann has a total of 319 co-authors. Here are the top co-authors by number of shared publications:
B. Jeanneret
Federal Office of Metrology METAS, Lindenweg 50, 3003 Bern-Wabern, Switzerland
18 shared publicationsW. Beer
11 shared publicationsH.J. Leisi
10 shared publicationsP.F.A. Goudsmit
10 shared publications- Andrea Vacchi
Università degli Studi di Udine
6 shared publications - Blaise Jeanneret
Electricity Section, Federal Institute of Metrology, Lindenweg 50, CH-3003 Bern-Wabern, SWITZERLAND
6 shared publications
Latest Publications
- 22 March 2022
- Published by IOP Publishing in Metrologia
- Vol. 59 (2) , 025008
First realisation of the kilogram with the METAS Kibble balance
After several years of development and continuous improvement, the Kibble balance at the Federal Institute of Metrology (METAS) is now operational. Its stability and reliability allows high precision measurements to be performed under vacuum. Two measurement campaigns were conducted in 2021 with 1 kg stainless steel test masses. The result differs from the value deduced from the calibration following the dissemination process after the redefinition of the kilogram by 6 μg with a total standard uncertainty of 43 μg (k = 1). This paper presents the details of this first result with its associated uncertainty budget.
- 22 March 2022
- Published by IOP Publishing in Metrologia
- Vol. 59 (2) , 025008
First realisation of the kilogram with the METAS Kibble balance
After several years of development and continuous improvement, the Kibble balance at the Federal Institute of Metrology (METAS) is now operational. Its stability and reliability allows high precision measurements to be performed under vacuum. Two measurement campaigns were conducted in 2021 with 1 kg stainless steel test masses. The result differs from the value deduced from the calibration following the dissemination process after the redefinition of the kilogram by 6 μg with a total standard uncertainty of 43 μg (k = 1). This paper presents the details of this first result with its associated uncertainty budget.
- Open Access
- 28 December 2018
- Published by Wiley in Annalen der Physik
- Vol. 531 (5)
The Elementary Charge for the Definition and Realization of the Ampere
The elementary charge e is one of the seven defining constants in the revised International System of Units (SI). Here, the determination of the elementary charge with the highest precision is discussed, including the results of the special CODATA adjustment leading to the fixed value of e. The various options to realize the ampere and the other electrical units in the revised SI, either through the counting of electrons by using single‐electron tunneling devices or through the Josephson and quantum Hall effect, respectively, are further elucidated.
- 28 December 2018
- Published by Wiley in Annalen der Physik
- Vol. 531 (5)
Open AccessThe Elementary Charge for the Definition and Realization of the Ampere
The elementary charge e is one of the seven defining constants in the revised International System of Units (SI). Here, the determination of the elementary charge with the highest precision is discussed, including the results of the special CODATA adjustment leading to the fixed value of e. The various options to realize the ampere and the other electrical units in the revised SI, either through the counting of electrons by using single‐electron tunneling devices or through the Josephson and quantum Hall effect, respectively, are further elucidated.
- Open Access
- 4 August 2017
- Published by IOP Publishing in Metrologia
- Vol. 54 (5) , R1-R24
Metrology in electricity and magnetism: EURAMET activities today and tomorrow
Metrology dedicated to electricity and magnetism has changed considerably in recent years. It encompasses almost all modern scientific, industrial, and societal challenges, e.g. the revision of the International System of Units, the profound transformation of industry, changes in energy use and generation, health, and environment, as well as nanotechnologies (including graphene and 2D materials) and quantum engineering. Over the same period, driven by the globalization of worldwide trade, the Mutual Recognition Arrangement (referred to as the CIPM MRA) was set up. As a result, the regional metrology organizations (RMOs) of national metrology institutes have grown in significance. EURAMET is the European RMO and has been very prominent in developing a strategic research agenda (SRA) and has established a comprehensive research programme. This paper reviews the highlights of EURAMET in electrical metrology within the European Metrology Research Programme and its main contributions to the CIPM MRA. In 2012 EURAMET undertook an extensive roadmapping exercise for proposed activities for the next decade which will also be discussed in this paper. This work has resulted in a new SRA of the second largest European funding programme: European Metrology Programme for Innovation and Research.
- 4 August 2017
- Published by IOP Publishing in Metrologia
- Vol. 54 (5) , R1-R24
Open AccessMetrology in electricity and magnetism: EURAMET activities today and tomorrow
Metrology dedicated to electricity and magnetism has changed considerably in recent years. It encompasses almost all modern scientific, industrial, and societal challenges, e.g. the revision of the International System of Units, the profound transformation of industry, changes in energy use and generation, health, and environment, as well as nanotechnologies (including graphene and 2D materials) and quantum engineering. Over the same period, driven by the globalization of worldwide trade, the Mutual Recognition Arrangement (referred to as the CIPM MRA) was set up. As a result, the regional metrology organizations (RMOs) of national metrology institutes have grown in significance. EURAMET is the European RMO and has been very prominent in developing a strategic research agenda (SRA) and has established a comprehensive research programme. This paper reviews the highlights of EURAMET in electrical metrology within the European Metrology Research Programme and its main contributions to the CIPM MRA. In 2012 EURAMET undertook an extensive roadmapping exercise for proposed activities for the next decade which will also be discussed in this paper. This work has resulted in a new SRA of the second largest European funding programme: European Metrology Programme for Innovation and Research.
- 1 July 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
The METAS watt balance Mark II
The watt balance Mark II of the Federal Institute of Metrology METAS is ready to start the measurement of the Planck constant. After an intensive conception phase, the different modules of the experiment have been designed, realized and characterized in close collaboration with external partners. Beside an overview of the experimental setup and some results, the present paper shows also theoretical aspects and simulation results of the magnetic circuit. First results of the Planck constant should be available at the time of the conference.
- 1 July 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
The METAS watt balance Mark II
The watt balance Mark II of the Federal Institute of Metrology METAS is ready to start the measurement of the Planck constant. After an intensive conception phase, the different modules of the experiment have been designed, realized and characterized in close collaboration with external partners. Beside an overview of the experimental setup and some results, the present paper shows also theoretical aspects and simulation results of the magnetic circuit. First results of the Planck constant should be available at the time of the conference.
- 1 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 05891485,p. 290-291
Accurate high-ohmic resistance measurement techniques up to 1 PΩ
An overview is presented on precision high-ohmic resistance measurements for values of 100 MΩ and above. The two main measurement techniques in this resistance range are discussed, the current integration technique and the adapted Wheatstone bridge. The quality of high-ohmic resistance standards, especially their time constants, temperature and voltage dependence, often is limiting the final uncertainty that can be reached. Still, expanded uncertainties (k = 2) of only a few parts in 10 5 are achievable at the 1 TΩ level.
- 1 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 05891485,p. 290-291
Accurate high-ohmic resistance measurement techniques up to 1 PΩ
An overview is presented on precision high-ohmic resistance measurements for values of 100 MΩ and above. The two main measurement techniques in this resistance range are discussed, the current integration technique and the adapted Wheatstone bridge. The quality of high-ohmic resistance standards, especially their time constants, temperature and voltage dependence, often is limiting the final uncertainty that can be reached. Still, expanded uncertainties (k = 2) of only a few parts in 10 5 are achievable at the 1 TΩ level.
- 1 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 714-715
The METAS watt balance Mark II experiment: Progress report
In the context of the future definition of the mass unit, a promising approach is to link the kilogram to the Planck constant using, for example a watt balance. The Federal Institute of Metrology METAS is pursuing this route and is currently setting up a second version of the experiment. This METAS watt balance Mark II experiment is now assembled and ready for the first experimental tests. The design and the operation are described in this paper, and the first results should be available at the time of the conference.
- 1 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 714-715
The METAS watt balance Mark II experiment: Progress report
In the context of the future definition of the mass unit, a promising approach is to link the kilogram to the Planck constant using, for example a watt balance. The Federal Institute of Metrology METAS is pursuing this route and is currently setting up a second version of the experiment. This METAS watt balance Mark II experiment is now assembled and ready for the first experimental tests. The design and the operation are described in this paper, and the first results should be available at the time of the conference.
- 31 March 2014
- Published by IOP Publishing in Metrologia
- Vol. 51 (2) , S88-S95
Development and integration of high straightness flexure guiding mechanisms dedicated to the METAS watt balance Mark II
- 31 March 2014
- Published by IOP Publishing in Metrologia
- Vol. 51 (2) , S88-S95
Development and integration of high straightness flexure guiding mechanisms dedicated to the METAS watt balance Mark II
- 13 May 2013
- Published by IOP Publishing in Metrologia
- Vol. 50 (3) , 235-242
Design of the new METAS watt balance experiment Mark II
- 13 May 2013
- Published by IOP Publishing in Metrologia
- Vol. 50 (3) , 235-242
Design of the new METAS watt balance experiment Mark II
- 1 January 2013
- Published by IOP Publishing in Metrologia
- Vol. 50 (1A) , 01008
Final report on supplementary comparison EURAMET.EM-S32: Comparison of resistance standards at 1 TΩ and 100 TΩ
- 1 January 2013
- Published by IOP Publishing in Metrologia
- Vol. 50 (1A) , 01008
Final report on supplementary comparison EURAMET.EM-S32: Comparison of resistance standards at 1 TΩ and 100 TΩ
- 16 November 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 62 (6) , 1723-1728
Low-Ohmic Resistance Comparison: Measurement Capabilities and Resistor Traveling Behavior
The low-ohmic resistance measurement capabilities of the Van Swinden Laboratorium, National Institute of Standards and Technology, and the Federal Office of Metrology (METAS) were compared using a set of resistors with values 100 mΩ, 10 mΩ, 1 mΩ, and 100 μΩ, respectively. The measurement results of the three laboratories agree extremely well within the respective measurement uncertainties with the comparison reference value. Careful transport of the resistors was crucial for achieving this result. Still, some of the resistors showed steps in value at each transport which likely relates to the construction of the resistance elements of these resistors.
- 16 November 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 62 (6) , 1723-1728
Low-Ohmic Resistance Comparison: Measurement Capabilities and Resistor Traveling Behavior
The low-ohmic resistance measurement capabilities of the Van Swinden Laboratorium, National Institute of Standards and Technology, and the Federal Office of Metrology (METAS) were compared using a set of resistors with values 100 mΩ, 10 mΩ, 1 mΩ, and 100 μΩ, respectively. The measurement results of the three laboratories agree extremely well within the respective measurement uncertainties with the comparison reference value. Careful transport of the resistors was crucial for achieving this result. Still, some of the resistors showed steps in value at each transport which likely relates to the construction of the resistance elements of these resistors.