Christian Marsching
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Christian Marsching has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Carsten Hopf
CeMOS Research and Transfer Center Mass Spectrometry and Optical Spectroscopy Technische Hochschule Mannheim Mannheim Germany
3 shared publications Alexander Geisel
Center for Mass Spectrometry and Optical Spectroscopy (CeMOS)
1 shared publicationAlexander Marx
Institute of Pathology, University Medical Center Mannheim of Heidelberg University
1 shared publication- Annabelle Fülöp
Center for Mass Spectrometry and Optical Spectroscopy (CeMOS), Mannheim University of Applied Sciences, Paul-Wittsack-Str. 10, 68163 Mannheim, Germany
1 shared publication Carina Ramallo Guevara
Center for Mass Spectrometry and Optical Spectroscopy (CeMOS)
1 shared publication- Christiane A. Opitz
German Cancer Research Center (DKFZ), Heidelberg, Division of Metabolic Crosstalk in Cancer and the German Cancer Consortium (DKTK), DKFZ Core Center Heidelberg, Heidelberg, Germany
1 shared publication
Latest Publications
- Open Access
- 3 November 2022
- Published by MDPI AG in Pharmaceuticals
- Vol. 15 (11) , 1356
Device-Controlled Microcondensation for Spatially Confined On-Tissue Digests in MALDI Imaging of N-Glycans
On-tissue enzymatic digestion is a prerequisite for MALDI mass spectrometry imaging (MSI) and spatialomic analysis of tissue proteins and their N-glycan conjugates. Despite the more widely accepted importance of N-glycans as diagnostic and prognostic biomarkers of many diseases and their potential as pharmacodynamic markers, the crucial sample preparation step, namely on-tissue digestion with enzymes like PNGaseF, is currently mainly carried out by specialized laboratories using home-built incubation arrangements, e.g., petri dishes placed in an incubator. Standardized spatially confined enzyme digests, however, require precise control and possible regulation of humidity and temperature, as high humidity increases the risk of analyte dislocation and low humidity compromises enzyme function. Here, a digestion device that controls humidity by cyclic ventilation and heating of the slide holder and the chamber lid was designed to enable controlled micro-condensation on the slide and to stabilize and monitor the digestion process. The device presented here may help with standardization in MSI. Using sagittal mouse brain sections and xenografted human U87 glioblastoma cells in CD1 nu/nu mouse brain, a device-controlled workflow for MALDI MSI of N-glycans was developed.
- 3 November 2022
- Published by MDPI AG in Pharmaceuticals
- Vol. 15 (11) , 1356
Open AccessDevice-Controlled Microcondensation for Spatially Confined On-Tissue Digests in MALDI Imaging of N-Glycans
On-tissue enzymatic digestion is a prerequisite for MALDI mass spectrometry imaging (MSI) and spatialomic analysis of tissue proteins and their N-glycan conjugates. Despite the more widely accepted importance of N-glycans as diagnostic and prognostic biomarkers of many diseases and their potential as pharmacodynamic markers, the crucial sample preparation step, namely on-tissue digestion with enzymes like PNGaseF, is currently mainly carried out by specialized laboratories using home-built incubation arrangements, e.g., petri dishes placed in an incubator. Standardized spatially confined enzyme digests, however, require precise control and possible regulation of humidity and temperature, as high humidity increases the risk of analyte dislocation and low humidity compromises enzyme function. Here, a digestion device that controls humidity by cyclic ventilation and heating of the slide holder and the chamber lid was designed to enable controlled micro-condensation on the slide and to stabilize and monitor the digestion process. The device presented here may help with standardization in MSI. Using sagittal mouse brain sections and xenografted human U87 glioblastoma cells in CD1 nu/nu mouse brain, a device-controlled workflow for MALDI MSI of N-glycans was developed.
- Open Access
- 20 July 2021
- Published by Oxford University Press (OUP) in GigaScience
- Vol. 10 (7)
M2aia—Interactive, fast, and memory-efficient analysis of 2D and 3D multi-modal mass spectrometry imaging data
Mass spectrometry imaging (MSI) is a label-free analysis method for resolving bio-molecules or pharmaceuticals in the spatial domain. It offers unique perspectives for the examination of entire organs or other tissue specimens. Owing to increasing capabilities of modern MSI devices, the use of 3D and multi-modal MSI becomes feasible in routine applications—resulting in hundreds of gigabytes of data. To fully leverage such MSI acquisitions, interactive tools for 3D image reconstruction, visualization, and analysis are required, which preferably should be open-source to allow scientists to develop custom extensions. We introduce M2aia (MSI applications for interactive analysis in MITK), a software tool providing interactive and memory-efficient data access and signal processing of multiple large MSI datasets stored in imzML format. M2aia extends MITK, a popular open-source tool in medical image processing. Besides the steps of a typical signal processing workflow, M2aia offers fast visual interaction, image segmentation, deformable 3D image reconstruction, and multi-modal registration. A unique feature is that fused data with individual mass axes can be visualized in a shared coordinate system. We demonstrate features of M2aia by reanalyzing an N-glycan mouse kidney dataset and 3D reconstruction and multi-modal image registration of a lipid and peptide dataset of a mouse brain, which we make publicly available. To our knowledge, M2aia is the first extensible open-source application that enables a fast, user-friendly, and interactive exploration of large datasets. M2aia is applicable to a wide range of MSI analysis tasks.
- 20 July 2021
- Published by Oxford University Press (OUP) in GigaScience
- Vol. 10 (7)
Open AccessM2aia—Interactive, fast, and memory-efficient analysis of 2D and 3D multi-modal mass spectrometry imaging data
Mass spectrometry imaging (MSI) is a label-free analysis method for resolving bio-molecules or pharmaceuticals in the spatial domain. It offers unique perspectives for the examination of entire organs or other tissue specimens. Owing to increasing capabilities of modern MSI devices, the use of 3D and multi-modal MSI becomes feasible in routine applications—resulting in hundreds of gigabytes of data. To fully leverage such MSI acquisitions, interactive tools for 3D image reconstruction, visualization, and analysis are required, which preferably should be open-source to allow scientists to develop custom extensions. We introduce M2aia (MSI applications for interactive analysis in MITK), a software tool providing interactive and memory-efficient data access and signal processing of multiple large MSI datasets stored in imzML format. M2aia extends MITK, a popular open-source tool in medical image processing. Besides the steps of a typical signal processing workflow, M2aia offers fast visual interaction, image segmentation, deformable 3D image reconstruction, and multi-modal registration. A unique feature is that fused data with individual mass axes can be visualized in a shared coordinate system. We demonstrate features of M2aia by reanalyzing an N-glycan mouse kidney dataset and 3D reconstruction and multi-modal image registration of a lipid and peptide dataset of a mouse brain, which we make publicly available. To our knowledge, M2aia is the first extensible open-source application that enables a fast, user-friendly, and interactive exploration of large datasets. M2aia is applicable to a wide range of MSI analysis tasks.
- Open Access
- 27 February 2019
- Published by Cold Spring Harbor Laboratory in bioRxiv
- p. 562553
Quantitative Mass Spectrometry Imaging Reveals Mutation Status-independent Lack of Imatinib Penetration into Liver Metastases of Gastrointestinal Stromal Tumors
Mass spectrometry imaging (MSI) is an enabling technology for label-free drug disposition studies at high spatial resolution in life science- and pharmaceutical research. We present the first extensive clinical matrix-assisted laser desorption/ionization (MALDI) quantitative mass spectrometry imaging (qMSI) study of drug uptake and distribution in clinical specimen, analyzing 56 specimens of tumor and corresponding non-tumor tissues from 28 imatinib-treated patients with biopsy-proven gastrointestinal stromal tumors (GIST). For validation, we compared MALDI-TOF-qMSI with conventional UPLC-ESI-QTOF-MS-based quantification from tissue extracts and with ultra-high resolution MALDI-FTICR-qMSI. We introduced a novel generalized nonlinear calibration model of drug quantities based on focused computational evaluation of drug-containing areas that enabled better data fitting and assessment of the inherent method nonlinearities. Imatinib tissue spatial maps revealed striking inefficiency in drug penetration into GIST liver metastases even though the corresponding healthy liver tissues in the vicinity showed abundant imatinib levels beyond the limit of quantification (LOQ), thus providing evidence for secondary drug resistance independent of mutation status. Taken together, these findings underline the important application of MALDI-qMSI for studying the spatial distribution of molecularly targeted therapeutics in oncology.
- 27 February 2019
- Published by Cold Spring Harbor Laboratory in bioRxiv
- p. 562553
Open AccessQuantitative Mass Spectrometry Imaging Reveals Mutation Status-independent Lack of Imatinib Penetration into Liver Metastases of Gastrointestinal Stromal Tumors
Mass spectrometry imaging (MSI) is an enabling technology for label-free drug disposition studies at high spatial resolution in life science- and pharmaceutical research. We present the first extensive clinical matrix-assisted laser desorption/ionization (MALDI) quantitative mass spectrometry imaging (qMSI) study of drug uptake and distribution in clinical specimen, analyzing 56 specimens of tumor and corresponding non-tumor tissues from 28 imatinib-treated patients with biopsy-proven gastrointestinal stromal tumors (GIST). For validation, we compared MALDI-TOF-qMSI with conventional UPLC-ESI-QTOF-MS-based quantification from tissue extracts and with ultra-high resolution MALDI-FTICR-qMSI. We introduced a novel generalized nonlinear calibration model of drug quantities based on focused computational evaluation of drug-containing areas that enabled better data fitting and assessment of the inherent method nonlinearities. Imatinib tissue spatial maps revealed striking inefficiency in drug penetration into GIST liver metastases even though the corresponding healthy liver tissues in the vicinity showed abundant imatinib levels beyond the limit of quantification (LOQ), thus providing evidence for secondary drug resistance independent of mutation status. Taken together, these findings underline the important application of MALDI-qMSI for studying the spatial distribution of molecularly targeted therapeutics in oncology.