Nayef M. Alanazi
Nayef M. Alanazi has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Filofteia-Laura Toma
Fraunhofer Institute for Material and Beam Technology IWS
4 shared publications - Lutz-Michael Berger
Fraunhofer IKTS, Fraunhofer Institute for Ceramic Technologies and Systems, Dresden, Germany
4 shared publications - Nadimul Haque Faisal
Robert Gordon University
4 shared publications - Rehan Ahmed
School of Engineering and Physical Sciences, Heriot-Watt University, Edinburgh, UK
3 shared publications - Annegret Potthoff
Fraunhofer Institute for Ceramic Technologies and Systems, Winterbergstrasse 28, D-01277 Dresden, Germany
2 shared publications E. K. Polychroniadis
Department of Physics, Aristotle University of Thessaloniki, Thessaloniki, Greece
2 shared publications
Latest Publications
- 1 November 2019
- Published by Elsevier in Journal of Industrial and Engineering Chemistry
- Vol. 79, 1-18
Progress in the development of sour corrosion inhibitors: Past, present, and future perspectives
- 1 November 2019
- Published by Elsevier in Journal of Industrial and Engineering Chemistry
- Vol. 79, 1-18
Progress in the development of sour corrosion inhibitors: Past, present, and future perspectives
- 1 September 2019
- Published by Elsevier in Surface and Coatings Technology
- Vol. 374, 815-821
Electrochemical properties of IrO2-Ti2O5-Co3O4 coated Ti anode in acid media
- 1 September 2019
- Published by Elsevier in Surface and Coatings Technology
- Vol. 374, 815-821
Electrochemical properties of IrO2-Ti2O5-Co3O4 coated Ti anode in acid media
- 4 August 2019
- Published by Association for Materials Protection and Performance (AMPP) in Corrosion
- Vol. 75 (10) , 1207-1215
The Effect of the Partial Pressure of H2S and CO2 on the Permeation of Hydrogen in Carbon Steel by Using Pressure Buildup Techniques
There are concerns in the industry about using an electrochemical technique for actual hydrogen permeation measurements where charging current is not a field condition. The objective of this work is to use pressure buildup techniques to study the influence of H2S and CO2 partial pressure on the relationship between hydrogen permeation and corrosion rate measured by different techniques. Sulfide films formed on carbon steel in a solution containing 5 wt% NaCl and 0.5 wt% acidic acid at various H2S and CO2 partial pressures were characterized, and the effect of the film on hydrogen permeation was also investigated. Field conditions were included in this study for comparison purposes. The relationship was modeled at the steady state of both hydrogen flux and corrosion rate. The results confirmed by use of two hydrogen flux measurement techniques (eudiometer and high-pressure buildup probe) and two corrosion measurement methods (weight loss coupons and coupled multiarray electrode system), that there is no direct correlation between hydrogen flux and corrosion rate. Therefore, the hydrogen permeation rate in H2S and CO2 environments was found to be more controlled by partial pressure of H2S than corrosion rate. The amount of descent in hydrogen flux, after reaching maximum of hydrogen permeation rate and before reaching a steady state, depends on the morphology and structure of corrosion films which are mainly controlled by concentration of H2S.
- 4 August 2019
- Published by Association for Materials Protection and Performance (AMPP) in Corrosion
- Vol. 75 (10) , 1207-1215
The Effect of the Partial Pressure of H2S and CO2 on the Permeation of Hydrogen in Carbon Steel by Using Pressure Buildup Techniques
There are concerns in the industry about using an electrochemical technique for actual hydrogen permeation measurements where charging current is not a field condition. The objective of this work is to use pressure buildup techniques to study the influence of H2S and CO2 partial pressure on the relationship between hydrogen permeation and corrosion rate measured by different techniques. Sulfide films formed on carbon steel in a solution containing 5 wt% NaCl and 0.5 wt% acidic acid at various H2S and CO2 partial pressures were characterized, and the effect of the film on hydrogen permeation was also investigated. Field conditions were included in this study for comparison purposes. The relationship was modeled at the steady state of both hydrogen flux and corrosion rate. The results confirmed by use of two hydrogen flux measurement techniques (eudiometer and high-pressure buildup probe) and two corrosion measurement methods (weight loss coupons and coupled multiarray electrode system), that there is no direct correlation between hydrogen flux and corrosion rate. Therefore, the hydrogen permeation rate in H2S and CO2 environments was found to be more controlled by partial pressure of H2S than corrosion rate. The amount of descent in hydrogen flux, after reaching maximum of hydrogen permeation rate and before reaching a steady state, depends on the morphology and structure of corrosion films which are mainly controlled by concentration of H2S.
- Open Access
- 30 October 2018
- Published by Springer Nature in Journal of Thermal Spray Technology
- Vol. 27 (8) , 1579-1593
Comparative Study of Corrosion Performance of HVOF-Sprayed Coatings Produced Using Conventional and Suspension WC-Co Feedstock
- 30 October 2018
- Published by Springer Nature in Journal of Thermal Spray Technology
- Vol. 27 (8) , 1579-1593
Open AccessComparative Study of Corrosion Performance of HVOF-Sprayed Coatings Produced Using Conventional and Suspension WC-Co Feedstock
- Open Access
- 19 January 2017
- Published by Springer Nature in Tribology Letters
- Vol. 65 (2) , 1-27
Influence of Post-treatment on the Microstructural and Tribomechanical Properties of Suspension Thermally Sprayed WC–12 wt%Co Nanocomposite Coatings
- 19 January 2017
- Published by Springer Nature in Tribology Letters
- Vol. 65 (2) , 1-27
Open AccessInfluence of Post-treatment on the Microstructural and Tribomechanical Properties of Suspension Thermally Sprayed WC–12 wt%Co Nanocomposite Coatings
- Open Access
- 12 November 2014
- Published by Springer Nature in Journal of Thermal Spray Technology
- Vol. 24 (3) , 357-377
Structure Property Relationship of Suspension Thermally Sprayed WC-Co Nanocomposite Coatings
- 12 November 2014
- Published by Springer Nature in Journal of Thermal Spray Technology
- Vol. 24 (3) , 357-377
Open AccessStructure Property Relationship of Suspension Thermally Sprayed WC-Co Nanocomposite Coatings
- 1 October 2014
- Published by Association for Materials Protection and Performance (AMPP) in Corrosion
- Vol. 71 (3) , 305-315
Corrosion of Pipeline Steel X-60 Under Field-Collected Sludge Deposit in a Simulated Sour Environment
The inhibition of under deposit corrosion (UDC) of steel X-60 (UNS K03006) was studied under field-collected sludge deposits in a simulated sour environment by means of linear polarization resistance (LPR), coupled multi-electrode array system (CMAS), and weight-loss coupons. X-ray diffraction (XRD) and energy-dispersive x-ray spectroscopy (EDS) techniques were employed to identify the deposit composition. The adsorption of two corrosion inhibitors, fatty acid imidazoline and benzyl alkyl pyridinyl quaternary ammonium chloride (benzyl chloride quaternary), designed for steel corrosion protection in sour environments, and their inhibition activities under sludge deposits were investigated. The significance of determining the adsorption affinity of the inhibitors to field-sludge deposit in the selection of corrosion inhibitors was also demonstrated. The XRD analysis indicated that the field-sludge deposit consisted mainly of calcite phase. Fatty acid imidazoline inhibitor was found to exhibit higher affinity to the sludge deposit than did benzyl chloride quaternary. As a consequence, benzyl chloride quaternary inhibitor was more effective in inhibiting general and localized corrosion of carbon steel in the presence of sludge deposit in a simulated sour environment. The corrosion rate is increased by the deposit even in the absence of inhibition. Thus, the field-sludge deposit decreased the performance of inhibitors, as compared with inhibiting steel samples that contained no sludge deposits. A clear understanding of the inhibitor's interaction with field-sludge deposits is necessary to predict its inhibition performance under field-sludge deposits.
- 1 October 2014
- Published by Association for Materials Protection and Performance (AMPP) in Corrosion
- Vol. 71 (3) , 305-315
Corrosion of Pipeline Steel X-60 Under Field-Collected Sludge Deposit in a Simulated Sour Environment
The inhibition of under deposit corrosion (UDC) of steel X-60 (UNS K03006) was studied under field-collected sludge deposits in a simulated sour environment by means of linear polarization resistance (LPR), coupled multi-electrode array system (CMAS), and weight-loss coupons. X-ray diffraction (XRD) and energy-dispersive x-ray spectroscopy (EDS) techniques were employed to identify the deposit composition. The adsorption of two corrosion inhibitors, fatty acid imidazoline and benzyl alkyl pyridinyl quaternary ammonium chloride (benzyl chloride quaternary), designed for steel corrosion protection in sour environments, and their inhibition activities under sludge deposits were investigated. The significance of determining the adsorption affinity of the inhibitors to field-sludge deposit in the selection of corrosion inhibitors was also demonstrated. The XRD analysis indicated that the field-sludge deposit consisted mainly of calcite phase. Fatty acid imidazoline inhibitor was found to exhibit higher affinity to the sludge deposit than did benzyl chloride quaternary. As a consequence, benzyl chloride quaternary inhibitor was more effective in inhibiting general and localized corrosion of carbon steel in the presence of sludge deposit in a simulated sour environment. The corrosion rate is increased by the deposit even in the absence of inhibition. Thus, the field-sludge deposit decreased the performance of inhibitors, as compared with inhibiting steel samples that contained no sludge deposits. A clear understanding of the inhibitor's interaction with field-sludge deposits is necessary to predict its inhibition performance under field-sludge deposits.
- 1 December 2010
- Published by Elsevier in Surface and Coatings Technology
- Vol. 205 (6) , 1750-1756
Substitution of hexavalent chromate conversion treatment with a plasma electrolytic oxidation process to improve the corrosion properties of ion vapour deposited AlMg coatings
- 1 December 2010
- Published by Elsevier in Surface and Coatings Technology
- Vol. 205 (6) , 1750-1756
Substitution of hexavalent chromate conversion treatment with a plasma electrolytic oxidation process to improve the corrosion properties of ion vapour deposited AlMg coatings