Masahiro Kozako
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Masahiro Kozako has a total of 81 co-authors. Here are the top co-authors by number of shared publications:
- Masayuki Hikita
Kyushu Institute of Technology
13 shared publications Masayuki Hikita
Department of Electrical and Electronic Engineering, Kyushu Institute of Technology, Fukuoka, Japan
4 shared publications- Ahmad Hafiz Mohd Hashim
Advanced Lightning, Power and Energy Research Centre (ALPER), Universiti Putra Malaysia, Serdang, Selangor, Malaysia
3 shared publications - Jasronita Jasni
Universiti Putra Malaysia
3 shared publications - Mohamad Kamarol Mohd Jamil
Universiti Sains Malaysia
3 shared publications - Mohd Amran Mohd Radzi
Department of Electrical and Electronic Engineering, Universiti Putra Malaysia, Selangor, Malaysia
3 shared publications
Latest Publications
- 8 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (3) , 1279-1288
Effect of Electrical Field on Conductivity of Synthetic Ester Induced by Space Charge Accumulation
Synthetic ester has emerged as an alternative in applications where mineral oil has traditionally been used. Furthermore, their new applications in areas such as converter transformers and battery energy storage systems are currently being investigated. Conductivity of insulating materials is a crucial parameter for such new applications. This paper investigates the impact of electrical field on the conductivity of synthetic ester through a combination of experimental and simulation studies. The experimental results indicated short-term conductivity increases while long-term conductivity exhibited a non-linear trend with applied electrical field. The simulation results showed that the increase in the measured short-term conductivity is due to field-enhanced charge dissociation whilst the non-linear trend in the measured long-term conductivity is a combined effect caused by space charge accumulation and field distortion. Furthermore, the simulation model incorporating space charge accumulation and charge injection is used to explain electrical field dependent conductivity phenomena, and key parameters and formulae describing field enhanced intrinsic and injected charge density are identified for synthetic ester and compared with those of mineral oil.
- 8 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (3) , 1279-1288
Effect of Electrical Field on Conductivity of Synthetic Ester Induced by Space Charge Accumulation
Synthetic ester has emerged as an alternative in applications where mineral oil has traditionally been used. Furthermore, their new applications in areas such as converter transformers and battery energy storage systems are currently being investigated. Conductivity of insulating materials is a crucial parameter for such new applications. This paper investigates the impact of electrical field on the conductivity of synthetic ester through a combination of experimental and simulation studies. The experimental results indicated short-term conductivity increases while long-term conductivity exhibited a non-linear trend with applied electrical field. The simulation results showed that the increase in the measured short-term conductivity is due to field-enhanced charge dissociation whilst the non-linear trend in the measured long-term conductivity is a combined effect caused by space charge accumulation and field distortion. Furthermore, the simulation model incorporating space charge accumulation and charge injection is used to explain electrical field dependent conductivity phenomena, and key parameters and formulae describing field enhanced intrinsic and injected charge density are identified for synthetic ester and compared with those of mineral oil.
- 25 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (6) , 3489-3496
Partial Discharge and Degradation Characteristics of Cast Resin Transformers Due to Bipolar Impulse Application
The objective of our work is to investigate partial discharge (PD) behaviors and degradation characteristics in winding insulation of an actual 22 kV cast resin transformer (CRTr) when subjected to bipolar impulse voltages. A differential high-frequency current transformer (HFCT) was employed on the high voltage coils to measure PD pulses induced by impulse voltages. Additionally, PD measurement at AC voltage was carried out to characterize the aging process resulting from the application of bipolar impulses. Experimental findings indicated that higher-level bipolar impulses could cause large-amplitude PDs in the windings, occurring at the peak value of the applied impulse voltages and increasing with the number of applied impulses. PD inception voltage (PDIV) at AC voltage decreased to the operating voltage, and the discharge amplitude and phase width in phase-resolved PD (PRPD) patterns increased due to impulse PD occurrences. Considering these results, it is evident that the bipolar lightning impulses could cause large-amplitude PDs, intensify impulse PD activity, and ultimately lead to dielectric breakdown in the CRTr windings. Space charge accumulation and residual charge deposition resulting from impulse PD play a significant role in the generation and the process of development for impulse PDs in the winding insulation, contributing to an acceleration effect in degradation process and eventual insulation failure.
- 25 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (6) , 3489-3496
Partial Discharge and Degradation Characteristics of Cast Resin Transformers Due to Bipolar Impulse Application
The objective of our work is to investigate partial discharge (PD) behaviors and degradation characteristics in winding insulation of an actual 22 kV cast resin transformer (CRTr) when subjected to bipolar impulse voltages. A differential high-frequency current transformer (HFCT) was employed on the high voltage coils to measure PD pulses induced by impulse voltages. Additionally, PD measurement at AC voltage was carried out to characterize the aging process resulting from the application of bipolar impulses. Experimental findings indicated that higher-level bipolar impulses could cause large-amplitude PDs in the windings, occurring at the peak value of the applied impulse voltages and increasing with the number of applied impulses. PD inception voltage (PDIV) at AC voltage decreased to the operating voltage, and the discharge amplitude and phase width in phase-resolved PD (PRPD) patterns increased due to impulse PD occurrences. Considering these results, it is evident that the bipolar lightning impulses could cause large-amplitude PDs, intensify impulse PD activity, and ultimately lead to dielectric breakdown in the CRTr windings. Space charge accumulation and residual charge deposition resulting from impulse PD play a significant role in the generation and the process of development for impulse PDs in the winding insulation, contributing to an acceleration effect in degradation process and eventual insulation failure.
- 10 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (6) , 2915-2921
Power Line Communication Application for Enhanced Partial Discharge Monitoring: From Theory to Application
Partial discharge activity is an important indicator of insulation health in high-voltage power apparatuses. Ensuring optimal functioning and timely equipment maintenance is crucial for operational efficiency and safety. This paper introduces an innovative approach to equipment monitoring by utilizing Power Line Communication (PLC) technology for detecting partial discharge (PD) data. The novelty of this approach lies in the PLC receiver’s dual capability to detect PD occurrences while simultaneously demodulating the PLC signal. This research analyzes the proposed low-cost, online PD monitoring system against traditional PD measurement techniques. Signals detectable by PLC were shown to propagate in PLC, allowing PLC to recognize PD from defect-simulated electrodes. To validate this, a simulated electrical substation circuit was constructed to facilitate the measurement of PD through the PLC system. The findings of this study indicate a good outcome for improving equipment monitoring procedures through the integration of PLC technology, providing a cost-effective alternative for continuous health assessment of electrical power equipment.
- 10 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (6) , 2915-2921
Power Line Communication Application for Enhanced Partial Discharge Monitoring: From Theory to Application
Partial discharge activity is an important indicator of insulation health in high-voltage power apparatuses. Ensuring optimal functioning and timely equipment maintenance is crucial for operational efficiency and safety. This paper introduces an innovative approach to equipment monitoring by utilizing Power Line Communication (PLC) technology for detecting partial discharge (PD) data. The novelty of this approach lies in the PLC receiver’s dual capability to detect PD occurrences while simultaneously demodulating the PLC signal. This research analyzes the proposed low-cost, online PD monitoring system against traditional PD measurement techniques. Signals detectable by PLC were shown to propagate in PLC, allowing PLC to recognize PD from defect-simulated electrodes. To validate this, a simulated electrical substation circuit was constructed to facilitate the measurement of PD through the PLC system. The findings of this study indicate a good outcome for improving equipment monitoring procedures through the integration of PLC technology, providing a cost-effective alternative for continuous health assessment of electrical power equipment.
- 9 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (6) , 3462-3468
Long-Term AC Partial Discharge Characteristics Till Dielectric Breakdown in an Aged 22 kV Cast Resin Transformer
This paper presents a trend analysis of long-term AC partial discharge (PD) characteristics till dielectric breakdown by accelerated degradation test in an aged 22 kV cast resin transformer (CRTr). The long-term AC PD characteristics till dielectric breakdown showed that the maximum PD charge Q max and the average PD charge Q mean increased sharply during the cumulative charging time t c , which was between 100 and 200 h before dielectric breakdown. These results suggest that defects could expand and propagate due to PD degradation and penetrate the insulating paper, resulting in large PD as a precursor to dielectric breakdown. With a voltage acceleration factor AFv and a frequency acceleration factor AFf in the accelerated degradation test considered, the time at which this sign was observed was well before dielectric breakdown. Therefore, this sign can be expected as one of the indicators of equipment replacement. The time sequence of AC PD characteristics just before dielectric breakdown was successfully measured. The result indicates the possibility that a fatal dielectric breakdown can be prevented owing to a fast interruption utilizing a circuit breaker. Furthermore, a breakdown site in the winding of the aged 22 kV CRTr could be located by the thermography; i.e. high electric field sections between the top block layers of the high-voltage side winding.
- 9 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (6) , 3462-3468
Long-Term AC Partial Discharge Characteristics Till Dielectric Breakdown in an Aged 22 kV Cast Resin Transformer
This paper presents a trend analysis of long-term AC partial discharge (PD) characteristics till dielectric breakdown by accelerated degradation test in an aged 22 kV cast resin transformer (CRTr). The long-term AC PD characteristics till dielectric breakdown showed that the maximum PD charge Q max and the average PD charge Q mean increased sharply during the cumulative charging time t c , which was between 100 and 200 h before dielectric breakdown. These results suggest that defects could expand and propagate due to PD degradation and penetrate the insulating paper, resulting in large PD as a precursor to dielectric breakdown. With a voltage acceleration factor AFv and a frequency acceleration factor AFf in the accelerated degradation test considered, the time at which this sign was observed was well before dielectric breakdown. Therefore, this sign can be expected as one of the indicators of equipment replacement. The time sequence of AC PD characteristics just before dielectric breakdown was successfully measured. The result indicates the possibility that a fatal dielectric breakdown can be prevented owing to a fast interruption utilizing a circuit breaker. Furthermore, a breakdown site in the winding of the aged 22 kV CRTr could be located by the thermography; i.e. high electric field sections between the top block layers of the high-voltage side winding.
- 5 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 30 (3) , 1247-1254
Application of ANFIS and ANN for Partial Discharge Localization in Oil Through Acoustic Emission
This paper presents an examination on the acoustic partial discharge (PD) localization in oil based on adaptive neuro-fuzzy inference system (ANFIS) and artificial neural network (ANN) approaches. Impedance matching circuit was used to measure the electrical PD. The acoustic PD was obtained through an acoustic emission (AE) sensor and pre-amplifier gain unit. In total, 112 coordinates for each of the AE sensors were utilized to evaluate the location of the PD. Once the voltage reached 30 kV, the electrical and acoustic PDs were recorded. Next, the data were pre-processed by moving average and analyzed by time-of-arrival (TOA), ANFIS and ANN. The distance between PD and AE sensor were calculated based on TOA to determine the PD location. These information were used as an input to train the network by optimizing epoch and neuron for ANFIS and ANN in order to locate PD. ANFIS has the best percentage of PD source prediction based on root mean square error (RMSE) and coefficient of determination (R 2 ) as compared to ANN. Meanwhile, the computation time for ANN is 1.75 s faster than ANFIS to perform PD localization based on acoustic emission PD signals.
- 5 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 30 (3) , 1247-1254
Application of ANFIS and ANN for Partial Discharge Localization in Oil Through Acoustic Emission
This paper presents an examination on the acoustic partial discharge (PD) localization in oil based on adaptive neuro-fuzzy inference system (ANFIS) and artificial neural network (ANN) approaches. Impedance matching circuit was used to measure the electrical PD. The acoustic PD was obtained through an acoustic emission (AE) sensor and pre-amplifier gain unit. In total, 112 coordinates for each of the AE sensors were utilized to evaluate the location of the PD. Once the voltage reached 30 kV, the electrical and acoustic PDs were recorded. Next, the data were pre-processed by moving average and analyzed by time-of-arrival (TOA), ANFIS and ANN. The distance between PD and AE sensor were calculated based on TOA to determine the PD location. These information were used as an input to train the network by optimizing epoch and neuron for ANFIS and ANN in order to locate PD. ANFIS has the best percentage of PD source prediction based on root mean square error (RMSE) and coefficient of determination (R 2 ) as compared to ANN. Meanwhile, the computation time for ANN is 1.75 s faster than ANFIS to perform PD localization based on acoustic emission PD signals.
- 8 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 29 (2) , 623-630
Partial Discharge Localization in Oil Through Acoustic Emission Technique Utilizing Fuzzy Logic
This study presents an examination of partial discharge (PD) localization in oil based on acoustic emission technique utilizing fuzzy logic. First, the PD measurement and localization systems are developed. In total, 2 coordinates of needle-plane electrodes that represent the PD location and 336 acoustic emission sensor (AES) coordinates are examined. The electrical PD is measured through an impedance matching circuit (IMC). The acoustic PD is acquired through AES and its signal is boosted by a preamplifier gain unit. The acoustic and electrical PDs are collected once the voltage reaches 30 kV. The data are first preprocessed by discrete wavelet transform (DWT) whereby it will be further analyzed by time of arrival (TOA), fuzzy logic Mamdani (FLM), and fuzzy logic Takagi–Sugeno (FLTS) methods. The arrival of time and distance between PD and AES are calculated based on TOA to find the PD location. Next, TOA and distance to PD location are used to define the input and output membership functions for FLM and FLTS to determine the PD location. It is found that FLTS has a great potential to be used for localization of the PD in oil whereby it has the lowest errors between actual PD location and AES. The performance of FLM and TOA is inferior to FLTS whereby the errors between actual PD location and AES are quite high for both PD locations.
- 8 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 29 (2) , 623-630
Partial Discharge Localization in Oil Through Acoustic Emission Technique Utilizing Fuzzy Logic
This study presents an examination of partial discharge (PD) localization in oil based on acoustic emission technique utilizing fuzzy logic. First, the PD measurement and localization systems are developed. In total, 2 coordinates of needle-plane electrodes that represent the PD location and 336 acoustic emission sensor (AES) coordinates are examined. The electrical PD is measured through an impedance matching circuit (IMC). The acoustic PD is acquired through AES and its signal is boosted by a preamplifier gain unit. The acoustic and electrical PDs are collected once the voltage reaches 30 kV. The data are first preprocessed by discrete wavelet transform (DWT) whereby it will be further analyzed by time of arrival (TOA), fuzzy logic Mamdani (FLM), and fuzzy logic Takagi–Sugeno (FLTS) methods. The arrival of time and distance between PD and AES are calculated based on TOA to find the PD location. Next, TOA and distance to PD location are used to define the input and output membership functions for FLM and FLTS to determine the PD location. It is found that FLTS has a great potential to be used for localization of the PD in oil whereby it has the lowest errors between actual PD location and AES. The performance of FLM and TOA is inferior to FLTS whereby the errors between actual PD location and AES are quite high for both PD locations.
- 1 March 2022
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Fundamentals and Materials
- Vol. 142 (3) , 108-115
Secondary Electron Emission Characteristics of Epoxy Resins with Nano-silica Addition and Thermal Treatment
With the activation of the lunar manned exploration plan, a power device that can be driven with high efficiency is required for effective utilization of electric power resources. On the ground, the development of nanocomposite materials in which nano-sized fillers are added to epoxy resin is being developed for semiconductor encapsulation materials and inverter module cases. These materials are expected to be applied to the development of lunar rover, and further improvement of the dielectric strength of the materials is required. Therefore, this time, we focused on the secondary electron emission yield (SEEY), which is the electrical property value, and measured for the nano-silica added epoxy resin when it was subjected to high temperature treatment, and whether it could be applied to a semi-empirical model formula. We report on the fact that we have examined the above.
- 1 March 2022
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Fundamentals and Materials
- Vol. 142 (3) , 108-115
Secondary Electron Emission Characteristics of Epoxy Resins with Nano-silica Addition and Thermal Treatment
With the activation of the lunar manned exploration plan, a power device that can be driven with high efficiency is required for effective utilization of electric power resources. On the ground, the development of nanocomposite materials in which nano-sized fillers are added to epoxy resin is being developed for semiconductor encapsulation materials and inverter module cases. These materials are expected to be applied to the development of lunar rover, and further improvement of the dielectric strength of the materials is required. Therefore, this time, we focused on the secondary electron emission yield (SEEY), which is the electrical property value, and measured for the nano-silica added epoxy resin when it was subjected to high temperature treatment, and whether it could be applied to a semi-empirical model formula. We report on the fact that we have examined the above.
- 12 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 69-72
Partial Discharge Degradation Mechanism of Nanocomposite Enameled Twisted Pair under Repetitive Impulse Voltage Application
The authors have developed enamel wire including nano-boehmite filler in polyimide coating expected to extend its life and reliability compared to conventional ones. We investigated partial discharge (PD) degradation and life characteristics of enamel twisted pair under bipolar repetitive impulse voltage application. An attempt is also made to compare thus obtained results with those for additive-free polyimide sample and nano-silica added polyester imide resin. The PD degradation mechanism is discussed with microscopic observation of sample surface and cross section using energy dispersive X-ray spectroscopy and transmission electron microscope results.
- 12 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 69-72
Partial Discharge Degradation Mechanism of Nanocomposite Enameled Twisted Pair under Repetitive Impulse Voltage Application
The authors have developed enamel wire including nano-boehmite filler in polyimide coating expected to extend its life and reliability compared to conventional ones. We investigated partial discharge (PD) degradation and life characteristics of enamel twisted pair under bipolar repetitive impulse voltage application. An attempt is also made to compare thus obtained results with those for additive-free polyimide sample and nano-silica added polyester imide resin. The PD degradation mechanism is discussed with microscopic observation of sample surface and cross section using energy dispersive X-ray spectroscopy and transmission electron microscope results.
- 12 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 466-469
Investigation on Partial Discharge Localization in Oil Based on Time of Arrival Method
This paper present a PD localization study based on acoustic PD signal. First, the PD localization was developed utilizing Acoustic Emission Sensor (AES). A test tank was fabricated whereby the PD was generated through needle-sphere electrode configuration. The electrical PD was measured through Impedance Matching Circuit (IMC). Based on the measured acoustic PD signal, the localization was carried based on Time of Arrival (TOA) method. The time between electrical and acoustic PD signals was used to determine the time of travel. It is found that the PD can be approximately localized through the AES system and TOA approach. At least 2 AES signals intersect at the PD location in the current study.
- 12 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 466-469
Investigation on Partial Discharge Localization in Oil Based on Time of Arrival Method
This paper present a PD localization study based on acoustic PD signal. First, the PD localization was developed utilizing Acoustic Emission Sensor (AES). A test tank was fabricated whereby the PD was generated through needle-sphere electrode configuration. The electrical PD was measured through Impedance Matching Circuit (IMC). Based on the measured acoustic PD signal, the localization was carried based on Time of Arrival (TOA) method. The time between electrical and acoustic PD signals was used to determine the time of travel. It is found that the PD can be approximately localized through the AES system and TOA approach. At least 2 AES signals intersect at the PD location in the current study.
- 28 November 2019
- Published by Springer Nature
- p. 673-683
Diagnostics for Vacuum Degree of Vacuum Interrupter Based on Partial Discharge Mechanisms Under Medium Vacuum Level
- 28 November 2019
- Published by Springer Nature
- p. 673-683
Diagnostics for Vacuum Degree of Vacuum Interrupter Based on Partial Discharge Mechanisms Under Medium Vacuum Level