  • Effect of Electrical Field on Conductivity of Synthetic Ester Induced by Space Charge Accumulation

    by Rui Yu, Shanika Matharage, Shuhang Shen, Zhongdong Wang, Motoo Tsuchie, Masahiro Kozako, Masayuki Hikita

    Synthetic ester has emerged as an alternative in applications where mineral oil has traditionally been used. Furthermore, their new applications in areas such as converter transformers and battery energy storage systems are currently being investigated. Conductivity of insulating materials is a crucial parameter for such new applications. This paper investigates the impact of electrical field on the conductivity of synthetic ester through a combination of experimental and simulation studies. The experimental results indicated short-term conductivity increases while long-term conductivity exhibited a non-linear trend with applied electrical field. The simulation results showed that the increase in the measured short-term conductivity is due to field-enhanced charge dissociation whilst the non-linear trend in the measured long-term conductivity is a combined effect caused by space charge accumulation and field distortion. Furthermore, the simulation model incorporating space charge accumulation and charge injection is used to explain electrical field dependent conductivity phenomena, and key parameters and formulae describing field enhanced intrinsic and injected charge density are identified for synthetic ester and compared with those of mineral oil.


  • Partial Discharge and Degradation Characteristics of Cast Resin Transformers Due to Bipolar Impulse Application

    by Yuanhang Yao, Mizuki Miyagawa, Masayuki Hikita, Masahiro Kozako, Yoshihiro Harada, Katsutoshi Takei, Masaru Ikeda, Kazunori Miyazaki, Kazuhiro Futakawa

    The objective of our work is to investigate partial discharge (PD) behaviors and degradation characteristics in winding insulation of an actual 22 kV cast resin transformer (CRTr) when subjected to bipolar impulse voltages. A differential high-frequency current transformer (HFCT) was employed on the high voltage coils to measure PD pulses induced by impulse voltages. Additionally, PD measurement at AC voltage was carried out to characterize the aging process resulting from the application of bipolar impulses. Experimental findings indicated that higher-level bipolar impulses could cause large-amplitude PDs in the windings, occurring at the peak value of the applied impulse voltages and increasing with the number of applied impulses. PD inception voltage (PDIV) at AC voltage decreased to the operating voltage, and the discharge amplitude and phase width in phase-resolved PD (PRPD) patterns increased due to impulse PD occurrences. Considering these results, it is evident that the bipolar lightning impulses could cause large-amplitude PDs, intensify impulse PD activity, and ultimately lead to dielectric breakdown in the CRTr windings. Space charge accumulation and residual charge deposition resulting from impulse PD play a significant role in the generation and the process of development for impulse PDs in the winding insulation, contributing to an acceleration effect in degradation process and eventual insulation failure.


  • Power Line Communication Application for Enhanced Partial Discharge Monitoring: From Theory to Application

    by Lunnetta Safura Lumba, Masahiro Kozako, Masayuki Hikita, Hidefumi Sato, Masahiro Soeda

    Partial discharge activity is an important indicator of insulation health in high-voltage power apparatuses. Ensuring optimal functioning and timely equipment maintenance is crucial for operational efficiency and safety. This paper introduces an innovative approach to equipment monitoring by utilizing Power Line Communication (PLC) technology for detecting partial discharge (PD) data. The novelty of this approach lies in the PLC receiver’s dual capability to detect PD occurrences while simultaneously demodulating the PLC signal. This research analyzes the proposed low-cost, online PD monitoring system against traditional PD measurement techniques. Signals detectable by PLC were shown to propagate in PLC, allowing PLC to recognize PD from defect-simulated electrodes. To validate this, a simulated electrical substation circuit was constructed to facilitate the measurement of PD through the PLC system. The findings of this study indicate a good outcome for improving equipment monitoring procedures through the integration of PLC technology, providing a cost-effective alternative for continuous health assessment of electrical power equipment.


  • Long-Term AC Partial Discharge Characteristics Till Dielectric Breakdown in an Aged 22 kV Cast Resin Transformer

    by Mizuki Miyagawa, Yuanhang Yao, Hideaki Kawano, Masayuki Hikita, Masahiro Kozako, Yoshihiro Harada, Katsutoshi Takei, Masaru Ikeda, Kazunori Miyazaki, Kazuhiro Futakawa

    This paper presents a trend analysis of long-term AC partial discharge (PD) characteristics till dielectric breakdown by accelerated degradation test in an aged 22 kV cast resin transformer (CRTr). The long-term AC PD characteristics till dielectric breakdown showed that the maximum PD charge Q max and the average PD charge Q mean increased sharply during the cumulative charging time t c , which was between 100 and 200 h before dielectric breakdown. These results suggest that defects could expand and propagate due to PD degradation and penetrate the insulating paper, resulting in large PD as a precursor to dielectric breakdown. With a voltage acceleration factor AFv and a frequency acceleration factor AFf in the accelerated degradation test considered, the time at which this sign was observed was well before dielectric breakdown. Therefore, this sign can be expected as one of the indicators of equipment replacement. The time sequence of AC PD characteristics just before dielectric breakdown was successfully measured. The result indicates the possibility that a fatal dielectric breakdown can be prevented owing to a fast interruption utilizing a circuit breaker. Furthermore, a breakdown site in the winding of the aged 22 kV CRTr could be located by the thermography; i.e. high electric field sections between the top block layers of the high-voltage side winding.


  • Application of ANFIS and ANN for Partial Discharge Localization in Oil Through Acoustic Emission

    by Ahmad Hafiz Mohd Hashim, Norhafiz Azis, Jasronita Jasni, Mohd Amran Mohd Radzi, Masahiro Kozako, Mohamad Kamarol Mohd Jamil, Zaini Yaakub

    This paper presents an examination on the acoustic partial discharge (PD) localization in oil based on adaptive neuro-fuzzy inference system (ANFIS) and artificial neural network (ANN) approaches. Impedance matching circuit was used to measure the electrical PD. The acoustic PD was obtained through an acoustic emission (AE) sensor and pre-amplifier gain unit. In total, 112 coordinates for each of the AE sensors were utilized to evaluate the location of the PD. Once the voltage reached 30 kV, the electrical and acoustic PDs were recorded. Next, the data were pre-processed by moving average and analyzed by time-of-arrival (TOA), ANFIS and ANN. The distance between PD and AE sensor were calculated based on TOA to determine the PD location. These information were used as an input to train the network by optimizing epoch and neuron for ANFIS and ANN in order to locate PD. ANFIS has the best percentage of PD source prediction based on root mean square error (RMSE) and coefficient of determination (R 2 ) as compared to ANN. Meanwhile, the computation time for ANN is 1.75 s faster than ANFIS to perform PD localization based on acoustic emission PD signals.


  • Partial Discharge Localization in Oil Through Acoustic Emission Technique Utilizing Fuzzy Logic

    by Ahmad Hafiz Mohd Hashim, Norhafiz Azis, Jasronita Jasni, Mohd Amran Mohd Radzi, Masahiro Kozako, Mohamad Kamarol Mohd Jamil, Zaini Yaakub

    This study presents an examination of partial discharge (PD) localization in oil based on acoustic emission technique utilizing fuzzy logic. First, the PD measurement and localization systems are developed. In total, 2 coordinates of needle-plane electrodes that represent the PD location and 336 acoustic emission sensor (AES) coordinates are examined. The electrical PD is measured through an impedance matching circuit (IMC). The acoustic PD is acquired through AES and its signal is boosted by a preamplifier gain unit. The acoustic and electrical PDs are collected once the voltage reaches 30 kV. The data are first preprocessed by discrete wavelet transform (DWT) whereby it will be further analyzed by time of arrival (TOA), fuzzy logic Mamdani (FLM), and fuzzy logic Takagi–Sugeno (FLTS) methods. The arrival of time and distance between PD and AES are calculated based on TOA to find the PD location. Next, TOA and distance to PD location are used to define the input and output membership functions for FLM and FLTS to determine the PD location. It is found that FLTS has a great potential to be used for localization of the PD in oil whereby it has the lowest errors between actual PD location and AES. The performance of FLM and TOA is inferior to FLTS whereby the errors between actual PD location and AES are quite high for both PD locations.


  • Secondary Electron Emission Characteristics of Epoxy Resins with Nano-silica Addition and Thermal Treatment

    by Akane Komori, Kojiro Nagata, Kosuke Sato, Hiroaki Miyake, Yasuhiro Tanaka, Masahiro Kozako, Masayuki Hikita

    With the activation of the lunar manned exploration plan, a power device that can be driven with high efficiency is required for effective utilization of electric power resources. On the ground, the development of nanocomposite materials in which nano-sized fillers are added to epoxy resin is being developed for semiconductor encapsulation materials and inverter module cases. These materials are expected to be applied to the development of lunar rover, and further improvement of the dielectric strength of the materials is required. Therefore, this time, we focused on the secondary electron emission yield (SEEY), which is the electrical property value, and measured for the nano-silica added epoxy resin when it was subjected to high temperature treatment, and whether it could be applied to a semi-empirical model formula. We report on the fact that we have examined the above.


  • Partial Discharge Degradation Mechanism of Nanocomposite Enameled Twisted Pair under Repetitive Impulse Voltage Application

    by Sho Takenouchi, Yuki Zenda, Masahiro Kozako, Masayuki Hikita, Nobutaka Fujimoto, Noriyuki Hayashizaka, Toshihiko Kato, Hideyuki Kikuchi

    The authors have developed enamel wire including nano-boehmite filler in polyimide coating expected to extend its life and reliability compared to conventional ones. We investigated partial discharge (PD) degradation and life characteristics of enamel twisted pair under bipolar repetitive impulse voltage application. An attempt is also made to compare thus obtained results with those for additive-free polyimide sample and nano-silica added polyester imide resin. The PD degradation mechanism is discussed with microscopic observation of sample surface and cross section using energy dispersive X-ray spectroscopy and transmission electron microscope results.


  • Investigation on Partial Discharge Localization in Oil Based on Time of Arrival Method

    by Ahmad Hafiz Mohd Hashim, Norhafiz Azis, Jasronita Jasni, Mohd Amran Mohd Radzi, Kozako Masahiro, Mohamad Kamarol Mohd Jamil

    This paper present a PD localization study based on acoustic PD signal. First, the PD localization was developed utilizing Acoustic Emission Sensor (AES). A test tank was fabricated whereby the PD was generated through needle-sphere electrode configuration. The electrical PD was measured through Impedance Matching Circuit (IMC). Based on the measured acoustic PD signal, the localization was carried based on Time of Arrival (TOA) method. The time between electrical and acoustic PD signals was used to determine the time of travel. It is found that the PD can be approximately localized through the AES system and TOA approach. At least 2 AES signals intersect at the PD location in the current study.


  • Diagnostics for Vacuum Degree of Vacuum Interrupter Based on Partial Discharge Mechanisms Under Medium Vacuum Level

    by Yusuke Nakano, Masahiro Kozako, Masayuki Hikita, Tsuyoshi Tanaka, Masato Kobayashi