FFFernando Franco

Fernando Franco

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Fernando Franco has a total of 55 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Optimization of asymmetric reference structures through non-evenly layered synthetic antiferromagnet for full bridge magnetic sensors based on CoFeB/MgO/CoFeB

    by Fernando Franco, Marilia Silva, Susana Cardoso, Paulo P. Freitas

    Industrial sensor applications rely on the implementation of full Wheatstone bridge architectures, demanding the development of low-cost and mass production methods of magnetic tunnel junctions (MTJ) based on CoFeB/MgO/CoFeB. In particular, monolithic bridge microfabrication has been demonstrated through the double deposition of MTJ stacks engineered by asymmetric reference layers with non-evenly layered synthetic antiferromagnet (SAF) structures. However, extending the standard double magnetic layered SAF into a triple magnetic multilayer system brings critical changes in the overall performance of the reference structure, which directly influences the magnetic stability of the device. Consequently, a theoretical model of a triple magnetic layered AF/SAF structure was developed to support the understanding of the magnetic response of the reference layers, aiming to improve the magnetic stability around zero field. A full MTJ Wheatstone bridge incorporating the optimized double and triple reference structures was microfabricated with a linear and hysteresis-free response. Furthermore, a high thermal endurance of both structures was verified through the measurement of the magnetotransport behavior of each type of MTJ structure within a reversible magnetic field range of ±2 kOe and a temperature sweep from room temperature up to 200 °C.


  • Reading thin film permanent magnet irregular patterns using magnetoresistive sensors

    by Sofia Abrunhosa, Karla J. Merazzo, Tiago Costa, Oliver Sandig, Fernando Franco, Susana Cardoso


  • Hybrid Rigid-Flexible Magnetoresistive Device Based on a Wafer Level Packaging Technology for Micrometric Proximity Measurements

    by Fernando Franco, Rosana A. Dias, Joao Gaspar, Susana Cardoso de Freitas, Paulo P. Freitas

    The sensor technology and the packaging method influence drastically the device performance by conditioning its sensitivity, the operating conditions and the distance between the magnetic source and the sensor. Magnetic encoders based on magnetoresistive (MR) sensors standout as a technology immune to dust, oil and fluids, and a cheaper system than optical solutions. Furthermore, they provide a higher spatial resolution, sensitivity and bandwidth than Hall effect sensors. However, to achieve a competitive prototype for applications with high constraints, it is necessary to combine state-of-the-art MR sensors with a packaging solution that entails a minimum impact on the sensor performance. Therefore, a new packaging method developed at wafer level is proposed for motion and positioning systems in planar architectures. The final prototype consists on a hybrid rigid-flexible MR probe combining a sensing chip with a flexible polyimide (PI) connector. This packaging technique pushes the contacts and establish electrical contact with the outer electronics on the back side or at a lower level parallel to the sensor plane, achieving a minimum distance of 7.5 μm between the sensor and the magnetic source. Finally, the device was successfully implemented as a magnetic encoder on a linear magnetic scale with 80 μm bit length revealing a sin/cos like signal with an amplitude of 42 mVRMS at a reading distance of 80 μm.


  • Reconfigurable Spintronics Wheatstone Bridge Sensors With Offset Voltage Compensation at Wafer Level

    by Fernando Franco, Susana Cardoso, Paulo P. Freitas

    Industrial requirements are continuously pushing the sensor limits toward higher signal-to-noise ratio under harsh environments, without compromising production costs by additional electronics. Non-full resistive Wheatstone bridge architectures arise as a compact and cheaper alternative to full-bridge measurement schemes, despite a lower output, linearity, and immunity to thermal drifts promoted by the replacement of the out-of-phase sensing elements by passive elements. However, the combination of state-of-the-art magnetoresistive (MR) sensors with thermally compatible materials used as tunable thin-film resistor at wafer level can lead to competitive prototypes for applications with high constraints. Therefore, the resistivity and the temperature coefficient of resistance (TCR) of Cr, Ti, and TiW thin films were evaluated as potential candidates for a thermal and electrical stable non-full MR bridge. Within a TCR around 1059 ± 12 ppm/°C for a spin-valve sensor lying between the values observed for a Ti thickness range of 300 Å up to 500 Å (571.9 ± 8.3 and 1347 ± 69 ppm/°C, respectively), a sin/cos magnetic encoder was prototyped in a non-full-bridge architecture with a thermal offset drift of 51.48 ± 0.25 nV/Vcc/°C and an offset voltage of 16 mV/Vcc.


  • Stay-on-target: a sensortile based micropositioning system

    by Pedro Ribeiro, Fernando Franco, MarílIa Silva, Miguel Neto, Susana Cardoso

    When analyzing biological samples, measurement probe placement is of critical importance, as biological signals are typically characterized by small amplitudes, and thus a close proximity to the source of the aforementioned signal is necessary to maximize the signal to noise ratio. In this work, we present the Stay-on-Target (SoT): a low-cost, micrometrically precise, fully motorized, semi-automatic positioning system developed for manipulation of a needle-shape magnetoresistive probe within a sample of biological tissue. The proposed system is composed of three units - the user interface (with real-time microscopy video feed), the control module and the micropositioning module. This last module is supported by the ST Sensortile wireless sensing module, providing accelerometer, gyroscope and magnetometer data, as well as environmental parameters (temperature, humidity and pressure). Two algorithms were developed, taking advantage of the accelerometer and magnetometer data to automatically determine needle angle with a precision below 2° and a precision of 90 μm in what concerns sample surface detection. Finally, a needle penetration is demonstrated on an agarose sample, with a magnetoresistive based sensing probe used for in-vitro neuroscience experiments.


  • Eddy Current–Tunneling Magneto-Resistive Sensor for Micromotion Detection of a Tibial Orthopaedic Implant

    by Rajas P. Khokle, Fernando Franco, Susana Cardoso de Freitas, Karu P. Esselle, Michael C. Heimlich, Desmond J. Bokor

    In this paper, an eddy current loop coupled with the Tunneling Magneto Resistor (EC-TMR) is used as a displacement sensor to detect the micromotion of an orthopaedic implant. The high sensitivity and signal to noise ratio of TMR sensor are used to achieve high resolution at a large stand-off distance. First, a small three turn rectangular eddy current loop of dimension 2.5 mm X 10 mm is designed and simulated inside the human body using a full wave EM simulator. Then it is fabricated and tested using vector network analyzer. The Magnetic Tunnel Junction stack is optimized and a 6-element TMR sensor is fabricated and characterized. The eddy current and tunnelling magneto resistive sensor are integrated and heterodyne detection technique is used to obtain the high-resolution micromotion detection at an extended standoff range. This technique can be used for in-vivo detection of the micromotion of the orthopaedic implant which will be useful in reducing the revision surgeries due to the mechanical failures of the implant.


  • High-Resolution Nondestructive Test Probes Based on Magnetoresistive Sensors

    by Diogo Miguel Caetano, Taimur Rabuske, Jorge Fernandes, Matthias Pelkner, Claude Fermont, Susana Cardoso, Belen Ribes, Fernando Franco, Johannes Paul, Moises Piedade, et al.

    This work discloses two high-sensitivity probes for Eddy Current Non-Destructive Test (NDT) of buried and surface defects. These probes incorporate 8 and 32 magnetoresistive sensors, respectively, which are optimized for high sensitivity and spatial resolution. The signal processing and interfacing are carried out by a full-custom Application Specific Integrated Circuit (ASIC). The ASIC signal chain performs with a thermal input-referred noise of 30 nV/ $\sqrt{\mathrm {HZ}}$ at 1 kHz, with 66 mW of power consumption, in a die with 3.7×3.4 mm $^2$ . NDT results are presented, showing that there is an increase in spatial resolution of surface defects when contrasted to prior art, enabling the probes to resolve defects with diameters of 0.44 mm, pitches of 0.6 mm, and minimum edge distance as low as 0.16 mm. The results also show that the probe for buried defects is a good all-round tool for detection of defects under cladding and multiple-plate flat junctions.


  • Open Access

    Reading magnetic ink patterns with magnetoresistive sensors

    by K. J. Merazzo, T. Costa, F. Franco, R. Ferreira, M. Zander, M. Türr, T. Becker, P. P. Freitas, S. Cardoso

    Information storage and monitoring relies on sensitive transducers with high robustness and reliability. This paper shows a methodology enabling the qualification of magnetic sensors for magnetic pattern readout, in applications different than hard disk magnetic recording. A magnetic tunnel junction MTJ sensor was incorporated in a reader setup for recognition of the magnetization of patterned arrays made of CoCrPt thin films and magnetic ink. The geometry of the sensor (in particular, the footprint and vertical distance to the media) was evaluated for two sensor configurations. The readout conditions were optimized to cope for variable media field intensity, resulting from CoCrPt film or magnetic ink thickness, with fixed reading distance and dimensions of the pattern. The calibration of the ink magnetic signal could be inferred from the analytical calculations carried out to validate the CoCrPt results.


  • On-Chip Magnetic Nanoparticle Manipulation and Trapping for Biomedical Applications

    by Vania Silverio, Maria J. Lopez-Martinez, Fernando Franco, Miguel Amaral, Joao Gaspar, Susana Cardoso, Paulo P. Freitas

    Biomedical applications and point-of-use devices often rely on nanoparticle concentration strategies. In this paper, on-chip magnetic trapping and manipulation of 300-500 nm superparamagnetic nanoparticles is achieved using thin film planar circular copper coils. The trap configuration combining a central coil surrounded by four other coils, all connected in series, successfully enables simultaneous attraction and repulsion, enhancing concentration of MNP. This bring advantages over static permanent magnets, where unidirectional actuation allows either attraction or repulsion. Because the distance between traps and the MNP is large (hundred micrometer), large electric currents up to 500 mA are needed to achieve fields of the order of hundreds of μTesla, which requires thermal management. Joule heating is effectively tackled by resorting to a novel cooling scheme comprising triangular microchannels milled onto copper substrates. Experimental results combining thermal surface mapping, magnetic field mapping and optical (fluorescence microscope) observations could validate the trapping efficacy of Estapor® Microspheres functionalized with BODIPY© 515 fluorophores.


  • Bioinspired Ciliary Force Sensor for Robotic Platforms

    by Pedro Ribeiro, Mohammed Asadullah Khan, Ahmed Alfadhel, Jurgen Kosel, Fernando Franco, Susana Cardoso, Alexandre Bernardino, Alexander Schmitz, Jose Santos-Victor, Lorenzo Jamone

    The detection of small forces is of great interest in any robotic application that involves interaction with the environment (e.g., objects manipulation, physical human-robot interaction, minimally invasive surgery), since it allows the robot to detect the contacts early on and to act accordingly. In this letter, we present a sensor design inspired by the ciliary structure frequently found in nature, consisting of an array of permanently magnetized cylinders (cilia) patterned over a giant magnetoresistance sensor (GMR). When these cylinders are deformed in shape due to applied forces, the stray magnetic field variation will change the GMR sensor resistivity, thus enabling the electrical measurement of the applied force. In this letter, we present two 3 mm × 3 mm prototypes composed of an array of five cilia with 1 mm of height and 120 and 200 μm of diameter for each prototype. A minimum force of 333 μN was measured. A simulation model for determining the magnetized cylinders average stray magnetic field is also presented.