Saransh Jain
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Saransh Jain has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
- Vijaya Kumar Narne
Department of Medical Rehabilitation Sciences, College of Applied Medical Sciences, King Khalid University, Abha, Saudi Arabia
12 shared publications - Sunil Kumar Ravi
Department of Medical Rehabilitation Sciences, College of Applied Medical Sciences, King Khalid University, Abha, Saudi Arabia
6 shared publications - Brian C. J. Moore
Cambridge Hearing Group, Department of Psychology, University of Cambridge, United Kingdom
5 shared publications - Chandni Jain
All India Institute of Speech and Hearing, Mysuru, India
4 shared publications - Krishna Yerraguntla
Department of Medical Rehabilitation Sciences, College of Applied Medical Sciences, King Khalid University, Abha 61481, Saudi Arabia
4 shared publications Nuggehalli Puttareviyah Nataraja
Jagadguru Sri Shivarathreeshwara (JSS) Institute of Speech and Hearing, Mysuru (Kar.), India
4 shared publications
Latest Publications
- 13 October 2026
- Published by American Speech Language Hearing Association in American Journal of Audiology
- p. 1-13
Acoustic Change Complex as an Objective Adjunct for Assessing Spectral Envelope Change Detectability Using Spectral Ripple Stimuli
Purpose: Behavioral measures of spectral envelope change detection, such as spectral ripple discrimination, are clinically informative but are influenced by attention, cognition, and task compliance. This study evaluated whether the acoustic change complex (ACC) can serve as an objective adjunct measure of spectral envelope change detectability in adults with normal hearing and examined the relationship between ACC latency measures and behavioral spectral ripple discrimination within the same cohort. Method: Fifteen adults with normal hearing (18–25 years of age) first completed behavioral spectral ripple discrimination testing to estimate perceptual thresholds, followed by ACC recordings. ACC responses were then recorded to ripple stimuli at three densities: 1 ripple per octave (RPO; low difficulty), 5 RPO (near threshold), and 8 RPO (above the spectral resolution limit). Primary electrophysiological outcomes included change-related peak latencies and amplitudes (P1′, N1′, P2′, N2′). Test–retest reliability was assessed using intraclass correlation coefficients (ICCs), and associations between behavioral thresholds and ACC measures were examined using Pearson correlations. Results: ACC responses were robust and consistently observed at 1 and 5 RPO, but no reliable ACC responses were identified at 8 RPO under the predefined detection criteria. Change-related latencies were significantly shorter for 5 RPO compared to 1 RPO ( p = .038–.039), whereas amplitude measures did not differ significantly between conditions. Test–retest reliability was good to excellent (ICC = .74–.94). Behavioral ripple discrimination thresholds were moderately correlated with ACC latency measures ( r = .52–.61, p < .05), suggesting a relationship between neural timing and the detectability of spectral envelope changes. Conclusions: ACC responses to spectral ripple transitions are associated with the detectability of spectral envelope changes and demonstrate good reliability. Latency-based ACC measures provide an objective adjunct to behavioral assessment. They may be useful for estimating the detectability of changes in spectral envelopes in populations where behavioral testing is not feasible.
- 13 October 2026
- Published by American Speech Language Hearing Association in American Journal of Audiology
- p. 1-13
Acoustic Change Complex as an Objective Adjunct for Assessing Spectral Envelope Change Detectability Using Spectral Ripple Stimuli
Purpose: Behavioral measures of spectral envelope change detection, such as spectral ripple discrimination, are clinically informative but are influenced by attention, cognition, and task compliance. This study evaluated whether the acoustic change complex (ACC) can serve as an objective adjunct measure of spectral envelope change detectability in adults with normal hearing and examined the relationship between ACC latency measures and behavioral spectral ripple discrimination within the same cohort. Method: Fifteen adults with normal hearing (18–25 years of age) first completed behavioral spectral ripple discrimination testing to estimate perceptual thresholds, followed by ACC recordings. ACC responses were then recorded to ripple stimuli at three densities: 1 ripple per octave (RPO; low difficulty), 5 RPO (near threshold), and 8 RPO (above the spectral resolution limit). Primary electrophysiological outcomes included change-related peak latencies and amplitudes (P1′, N1′, P2′, N2′). Test–retest reliability was assessed using intraclass correlation coefficients (ICCs), and associations between behavioral thresholds and ACC measures were examined using Pearson correlations. Results: ACC responses were robust and consistently observed at 1 and 5 RPO, but no reliable ACC responses were identified at 8 RPO under the predefined detection criteria. Change-related latencies were significantly shorter for 5 RPO compared to 1 RPO ( p = .038–.039), whereas amplitude measures did not differ significantly between conditions. Test–retest reliability was good to excellent (ICC = .74–.94). Behavioral ripple discrimination thresholds were moderately correlated with ACC latency measures ( r = .52–.61, p < .05), suggesting a relationship between neural timing and the detectability of spectral envelope changes. Conclusions: ACC responses to spectral ripple transitions are associated with the detectability of spectral envelope changes and demonstrate good reliability. Latency-based ACC measures provide an objective adjunct to behavioral assessment. They may be useful for estimating the detectability of changes in spectral envelopes in populations where behavioral testing is not feasible.
- Open Access
- 12 August 2026
- Published by Institute of Sensory Organs in Journal of Hearing Science
- Vol. 16 (2) , 23-34
COMPARISON OF A BOOTH-FREE AUDIOMETER WITH A CONVENTIONAL DEVICE IN TERMS OF IMMUNITY TO NOISE AND SUBJECTIVE COMFORT
Introduction: This study aimed to evaluate the noise immunity level (NIL) of the booth-free KUDUwave™ audiometer and compare the subjective comfort of its headphones against a conventional screening audiometer under simulated noise conditions, in order to determine its suitability for hearing screening in resource-limited settings. Material and methods: 30 normal-hearing adults (aged 20–25 years) participated in a repeated-measures crossover study. Pure-tone airand bone-conduction thresholds were obtained under quiet and background noise conditions using the KUDUwave audiometer and a conventional audiometer from Interacoustics. Three types of noise were presented: broadband noise (BBN), speech-shaped noise (SSN), and eight-talker babble (8-TB). In addition, the subjective comfort associated with each audiometer’s headset was evaluated. Results: Baseline air-conduction (AC) thresholds were comparable between the two audiometers, whereas bone-conduction (BC) thresholds were significantly lower with the KUDUwave, likely due to the occlusion effect. Across all noise conditions, the KUDUwave demonstrated higher NILs than the conventional audiometer, indicating greater resistance to ambient noise. In AC testing, NILs were lowest at low frequencies and highest at mid frequencies, with 8-TB producing greater masking effects than BBN and SSN. However, participants reported lower comfort with the KUDUwave headset compared to the conventional audiometer. Conclusions: The KUDUwave audiometer demonstrated greater noise immunity than the conventional device, indicating enhanced resistance to ambient noise. These findings suggest its potential suitability for hearing screening in non–sound-treated, community-based environments. However, its real-world utility and practical advantages in such settings need to be further validated through field-based studies.
- 12 August 2026
- Published by Institute of Sensory Organs in Journal of Hearing Science
- Vol. 16 (2) , 23-34
Open AccessCOMPARISON OF A BOOTH-FREE AUDIOMETER WITH A CONVENTIONAL DEVICE IN TERMS OF IMMUNITY TO NOISE AND SUBJECTIVE COMFORT
Introduction: This study aimed to evaluate the noise immunity level (NIL) of the booth-free KUDUwave™ audiometer and compare the subjective comfort of its headphones against a conventional screening audiometer under simulated noise conditions, in order to determine its suitability for hearing screening in resource-limited settings. Material and methods: 30 normal-hearing adults (aged 20–25 years) participated in a repeated-measures crossover study. Pure-tone airand bone-conduction thresholds were obtained under quiet and background noise conditions using the KUDUwave audiometer and a conventional audiometer from Interacoustics. Three types of noise were presented: broadband noise (BBN), speech-shaped noise (SSN), and eight-talker babble (8-TB). In addition, the subjective comfort associated with each audiometer’s headset was evaluated. Results: Baseline air-conduction (AC) thresholds were comparable between the two audiometers, whereas bone-conduction (BC) thresholds were significantly lower with the KUDUwave, likely due to the occlusion effect. Across all noise conditions, the KUDUwave demonstrated higher NILs than the conventional audiometer, indicating greater resistance to ambient noise. In AC testing, NILs were lowest at low frequencies and highest at mid frequencies, with 8-TB producing greater masking effects than BBN and SSN. However, participants reported lower comfort with the KUDUwave headset compared to the conventional audiometer. Conclusions: The KUDUwave audiometer demonstrated greater noise immunity than the conventional device, indicating enhanced resistance to ambient noise. These findings suggest its potential suitability for hearing screening in non–sound-treated, community-based environments. However, its real-world utility and practical advantages in such settings need to be further validated through field-based studies.
- Open Access
- 30 July 2026
- Published by Springer Nature in The Egyptian Journal of Otolaryngology
- Vol. 42 (1) , 205
Effect of age on binaural interaction abilities measured using the binaural fusion test
Objectives: Binaural interaction refers to how the two ears work together, playing a crucial role in everyday tasks such as sound localization and improving speech understanding in noisy or reverberant environments. As age increases, various physiological changes occur, which can affect binaural interaction. To study these changes and their impact on binaural processing, the binaural fusion test (BFT) was employed. Method: The study included 90 participants divided into three age groups: children (7–11 years), young adults (18–30 years), and older adults (50–68 years). Children and young adults had normal hearing thresholds (< 15 dBHL), while older adults had near-normal hearing (< 25 dBHL). All participants underwent the BFT in Kannada. Results: The one-way ANOVA test revealed a significant effect of age on BFT performance, with young adults achieving the highest scores, followed by children and then older adults. Additionally, when comparing age-related differences in Masking Level Difference scores (measured elsewhere) with BFT scores across the groups, it was found that BFT performance is relatively more resilient to the effects of aging. Conclusion: Older adults demonstrated poorer scores, likely due to age-related physiological changes. Additionally, children showed lower scores than young adults, indicating that the binaural interaction process continues to mature during childhood.
- 30 July 2026
- Published by Springer Nature in The Egyptian Journal of Otolaryngology
- Vol. 42 (1) , 205
Open AccessEffect of age on binaural interaction abilities measured using the binaural fusion test
Objectives: Binaural interaction refers to how the two ears work together, playing a crucial role in everyday tasks such as sound localization and improving speech understanding in noisy or reverberant environments. As age increases, various physiological changes occur, which can affect binaural interaction. To study these changes and their impact on binaural processing, the binaural fusion test (BFT) was employed. Method: The study included 90 participants divided into three age groups: children (7–11 years), young adults (18–30 years), and older adults (50–68 years). Children and young adults had normal hearing thresholds (< 15 dBHL), while older adults had near-normal hearing (< 25 dBHL). All participants underwent the BFT in Kannada. Results: The one-way ANOVA test revealed a significant effect of age on BFT performance, with young adults achieving the highest scores, followed by children and then older adults. Additionally, when comparing age-related differences in Masking Level Difference scores (measured elsewhere) with BFT scores across the groups, it was found that BFT performance is relatively more resilient to the effects of aging. Conclusion: Older adults demonstrated poorer scores, likely due to age-related physiological changes. Additionally, children showed lower scores than young adults, indicating that the binaural interaction process continues to mature during childhood.
- 9 July 2026
- Published by American Speech Language Hearing Association in Journal of Speech, Language, and Hearing Research
- Vol. 69 (7) , 3385-3398
Effect of Type of Speech Equalization and Averaging Method on the Long-Term Average Speech Spectra of Five Indian Languages and British English
Purpose: The purpose of this study was to compare two methods for determining the long-term average speech spectrum (LTASS) across languages—root-mean-square equalization and averaging (RMSe) and loudness equalization and averaging (Le)—and to assess their implications for hearing aid fitting methods. Method: Speech samples from multiple talkers of British English (BE), Indian English (IE), and four Indian languages were analyzed. For RMSe, the samples were equalized in overall root-mean-square (RMS) amplitude, and the RMS amplitude in each one-third-octave band was averaged across samples. For Le, the loudness of each talker's speech was equated using a loudness model, and estimated loudness values in each one-third-octave band were averaged. A preliminary experiment confirmed that equalizing the peak long-term loudness predicted by the model accurately equated speech loudness across languages. Results: With RMSe, LTASS differences across languages were observed primarily at high frequencies, whereas with Le, there were differences between BE and the Indian languages over a wide frequency range for both male and female speakers. Values of the Speech Intelligibility Index (SII) for an LTASS input at 60 dB SPL were calculated for several hypothetical patterns of hearing loss after application of frequency-dependent gains intended to give good audibility for speech at moderate levels. For the Indian languages, the SII was consistently higher when Le was used to determine the LTASS than when RMSe was used to determine the LTASS. Conclusions: The LTASS determined using Le provides a more perceptually relevant characterization of cross-language spectral differences than LTASS determined using RMSe. Hearing-aid fitting methods may be improved using language-specific LTASS values derived using Le.
- 9 July 2026
- Published by American Speech Language Hearing Association in Journal of Speech, Language, and Hearing Research
- Vol. 69 (7) , 3385-3398
Effect of Type of Speech Equalization and Averaging Method on the Long-Term Average Speech Spectra of Five Indian Languages and British English
Purpose: The purpose of this study was to compare two methods for determining the long-term average speech spectrum (LTASS) across languages—root-mean-square equalization and averaging (RMSe) and loudness equalization and averaging (Le)—and to assess their implications for hearing aid fitting methods. Method: Speech samples from multiple talkers of British English (BE), Indian English (IE), and four Indian languages were analyzed. For RMSe, the samples were equalized in overall root-mean-square (RMS) amplitude, and the RMS amplitude in each one-third-octave band was averaged across samples. For Le, the loudness of each talker's speech was equated using a loudness model, and estimated loudness values in each one-third-octave band were averaged. A preliminary experiment confirmed that equalizing the peak long-term loudness predicted by the model accurately equated speech loudness across languages. Results: With RMSe, LTASS differences across languages were observed primarily at high frequencies, whereas with Le, there were differences between BE and the Indian languages over a wide frequency range for both male and female speakers. Values of the Speech Intelligibility Index (SII) for an LTASS input at 60 dB SPL were calculated for several hypothetical patterns of hearing loss after application of frequency-dependent gains intended to give good audibility for speech at moderate levels. For the Indian languages, the SII was consistently higher when Le was used to determine the LTASS than when RMSe was used to determine the LTASS. Conclusions: The LTASS determined using Le provides a more perceptually relevant characterization of cross-language spectral differences than LTASS determined using RMSe. Hearing-aid fitting methods may be improved using language-specific LTASS values derived using Le.
- Open Access
- 24 May 2026
- Published by Elsevier in SSRN Electronic Journal
Designing a user-centered mHealth screening system for children in low-resource settings: A multi-stakeholder implementation study
Objective: To identify user requirements, usability expectations, and contextual constraints to inform the design and implementation of a scalable mobile health (mHealth) screening system for children in low-resource settings.Design: Cross-sectional, implementation-oriented survey.Participants: A total of 1,055 stakeholders, including teachers (n = 364), Anganwadi workers (n = 350), and parents/caregivers (n = 341) of children aged 3–10 years.Methods: A structured questionnaire assessed implementation-relevant domains of digital infrastructure and system readiness, awareness and screening context, operational workflow experience, usability and interaction readiness, system-level feasibility constraints, acceptability and workload implications, and system design requirements. Group differences were analyzed using chi-square tests, and multivariable logistic regression identified factors associated with willingness to use the system.Results: Digital readiness was high, with 96.7% reporting smartphone use and 76.5% daily usage; however, access to earphones/headphones was limited (19.6%). Although awareness of childhood hearing loss was high (91.6%), 81.0% reported no prior use of screening tools, indicating a substantial awareness–practice gap. Significant group differences were observed in awareness, screening experience, usability, and feasibility, whereas willingness (68.3%) and trust in AI-assisted outputs (78.9%) were consistent across groups. Key feasibility constraints included inconsistent internet and electricity access and limited availability of quiet environments. Respondents preferred short screening durations (6–10 minutes), simple workflows (1–3 steps), and multimodal guidance. Multivariable analysis showed that willingness was independently associated with respondent group and prior screening exposure, while digital infrastructure variables were not independently associated after adjustment.Conclusions: Successful implementation of mHealth screening systems in low-resource settings is associated with prior experience, workflow integration, and perceived feasibility rather than infrastructure or demographic factors alone. System design should prioritize simplicity, offline functionality, and integrated decision-support and referral pathways.
- 24 May 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessDesigning a user-centered mHealth screening system for children in low-resource settings: A multi-stakeholder implementation study
Objective: To identify user requirements, usability expectations, and contextual constraints to inform the design and implementation of a scalable mobile health (mHealth) screening system for children in low-resource settings.Design: Cross-sectional, implementation-oriented survey.Participants: A total of 1,055 stakeholders, including teachers (n = 364), Anganwadi workers (n = 350), and parents/caregivers (n = 341) of children aged 3–10 years.Methods: A structured questionnaire assessed implementation-relevant domains of digital infrastructure and system readiness, awareness and screening context, operational workflow experience, usability and interaction readiness, system-level feasibility constraints, acceptability and workload implications, and system design requirements. Group differences were analyzed using chi-square tests, and multivariable logistic regression identified factors associated with willingness to use the system.Results: Digital readiness was high, with 96.7% reporting smartphone use and 76.5% daily usage; however, access to earphones/headphones was limited (19.6%). Although awareness of childhood hearing loss was high (91.6%), 81.0% reported no prior use of screening tools, indicating a substantial awareness–practice gap. Significant group differences were observed in awareness, screening experience, usability, and feasibility, whereas willingness (68.3%) and trust in AI-assisted outputs (78.9%) were consistent across groups. Key feasibility constraints included inconsistent internet and electricity access and limited availability of quiet environments. Respondents preferred short screening durations (6–10 minutes), simple workflows (1–3 steps), and multimodal guidance. Multivariable analysis showed that willingness was independently associated with respondent group and prior screening exposure, while digital infrastructure variables were not independently associated after adjustment.Conclusions: Successful implementation of mHealth screening systems in low-resource settings is associated with prior experience, workflow integration, and perceived feasibility rather than infrastructure or demographic factors alone. System design should prioritize simplicity, offline functionality, and integrated decision-support and referral pathways.
- 2 April 2026
- Published by Taylor & Francis in International Journal of Audiology
- p. 1-13
Simplification and validation of the spectro-temporal ripple direction discrimination test in children
Spectral and temporal resolution are important for speech perception, particularly in noisy environments. The Spectro-temporal Ripple Direction Discrimination (STRtdir) test, originally developed for adults, assesses the spectro-temporal resolution. This study aimed to simplify the STRtdir paradigm for paediatric use and evaluate its criterion and construct validity. A within-subjects design was employed to compare STRtdir thresholds across different carrier frequencies, including a broadband noise (BBN) carrier and narrowband noise (NBN) carriers centred at 500, 1000, 2000, and 4000 Hz, and to examine the relationship between STRtdir thresholds and speech perception scores (in quiet and noise) in children. The STRtdir test was simplified based on a pilot study conducted on ten children and fifteen adults with normal hearing. The simplified STRtdir was administered to thirty-five children aged 7-10 years with normal hearing. A repeated-measures ANOVA across all carriers showed significant negative correlations between STRtdir and SNR-50, indicating that children with better spectro-temporal resolution have lower SNR-50, reflecting superior speech-in-noise perception. No correlation was found with speech-in-quiet. Multiple regression revealed that STRtdir thresholds explained 41.3% of the variance in SNR-50. The simplified STRtdir is a valid, reliable, child-friendly, and language-independent measure of spectro-temporal resolution for paediatric populations.
- 2 April 2026
- Published by Taylor & Francis in International Journal of Audiology
- p. 1-13
Simplification and validation of the spectro-temporal ripple direction discrimination test in children
Spectral and temporal resolution are important for speech perception, particularly in noisy environments. The Spectro-temporal Ripple Direction Discrimination (STRtdir) test, originally developed for adults, assesses the spectro-temporal resolution. This study aimed to simplify the STRtdir paradigm for paediatric use and evaluate its criterion and construct validity. A within-subjects design was employed to compare STRtdir thresholds across different carrier frequencies, including a broadband noise (BBN) carrier and narrowband noise (NBN) carriers centred at 500, 1000, 2000, and 4000 Hz, and to examine the relationship between STRtdir thresholds and speech perception scores (in quiet and noise) in children. The STRtdir test was simplified based on a pilot study conducted on ten children and fifteen adults with normal hearing. The simplified STRtdir was administered to thirty-five children aged 7-10 years with normal hearing. A repeated-measures ANOVA across all carriers showed significant negative correlations between STRtdir and SNR-50, indicating that children with better spectro-temporal resolution have lower SNR-50, reflecting superior speech-in-noise perception. No correlation was found with speech-in-quiet. Multiple regression revealed that STRtdir thresholds explained 41.3% of the variance in SNR-50. The simplified STRtdir is a valid, reliable, child-friendly, and language-independent measure of spectro-temporal resolution for paediatric populations.
- 5 March 2026
- Published by American Speech Language Hearing Association in American Journal of Audiology
- Vol. 35 (1) , 104-117
Cognitive Skills and Academic Performance in Children With Minimal to Mild Conductive Hearing Loss: The Roles of Listening Effort and Subjective Fatigue
Purpose: This study examined how cognitive skills (nonverbal intelligence, verbal working memory, and attention) influence academic performance in children with minimal to mild conductive hearing loss (mCHL) and whether this relationship is moderated by subjective fatigue and listening effort. We also compared these effects with age- and sex-matched children with normal hearing sensitivity (NHS). Method: A cross-sectional correlational study was conducted on 130 children with mCHL and 130 children with NHS (aged 10–12 years). Audiological testing, cognitive assessments (Seguin form board test, digit span, operation span, and dichotic digit tests), and subjective fatigue ratings (visual analog scale) were collected. Listening effort was measured using a dual-task paradigm that involved speech-in-noise and digit-reversal tasks. Teachers rated academic performance using the Academic Performance Rating Scale and supported by recent academic marks. Multiple linear regression and moderation analyses were performed. Results: Children with mCHL exhibited significantly higher listening effort, greater subjective fatigue, lower cognitive scores, and poorer academic performance than their peers with NHS did. Moderation analysis revealed that subjective fatigue significantly weakened the positive relationship between cognition and academic performance in children with mCHL but not in children with NHS. A z test confirmed that the moderating effect was significantly stronger in the mCHL group. Conclusions: These findings suggest that subjective fatigue plays a critical role in modulating the effects of cognition on academic success in children with mCHL. Interventions addressing listening efforts and fatigue management are suggested for improving educational outcomes in this population. Supplemental Material: https://doi.org/10.23641/asha.31057807
- 5 March 2026
- Published by American Speech Language Hearing Association in American Journal of Audiology
- Vol. 35 (1) , 104-117
Cognitive Skills and Academic Performance in Children With Minimal to Mild Conductive Hearing Loss: The Roles of Listening Effort and Subjective Fatigue
Purpose: This study examined how cognitive skills (nonverbal intelligence, verbal working memory, and attention) influence academic performance in children with minimal to mild conductive hearing loss (mCHL) and whether this relationship is moderated by subjective fatigue and listening effort. We also compared these effects with age- and sex-matched children with normal hearing sensitivity (NHS). Method: A cross-sectional correlational study was conducted on 130 children with mCHL and 130 children with NHS (aged 10–12 years). Audiological testing, cognitive assessments (Seguin form board test, digit span, operation span, and dichotic digit tests), and subjective fatigue ratings (visual analog scale) were collected. Listening effort was measured using a dual-task paradigm that involved speech-in-noise and digit-reversal tasks. Teachers rated academic performance using the Academic Performance Rating Scale and supported by recent academic marks. Multiple linear regression and moderation analyses were performed. Results: Children with mCHL exhibited significantly higher listening effort, greater subjective fatigue, lower cognitive scores, and poorer academic performance than their peers with NHS did. Moderation analysis revealed that subjective fatigue significantly weakened the positive relationship between cognition and academic performance in children with mCHL but not in children with NHS. A z test confirmed that the moderating effect was significantly stronger in the mCHL group. Conclusions: These findings suggest that subjective fatigue plays a critical role in modulating the effects of cognition on academic success in children with mCHL. Interventions addressing listening efforts and fatigue management are suggested for improving educational outcomes in this population. Supplemental Material: https://doi.org/10.23641/asha.31057807
- 19 November 2025
- Published by Springer Nature in Attention, Perception, & Psychophysics
- Vol. 88 (1) , 2
The effect of sensorineural hearing loss on auditory stream segregation measured as a function of interstimulus interval
Auditory stream segregation was measured using ABA-ABA sequences where A and B were the vowel |α| and A and B differed in fundamental frequency by
- 19 November 2025
- Published by Springer Nature in Attention, Perception, & Psychophysics
- Vol. 88 (1) , 2
The effect of sensorineural hearing loss on auditory stream segregation measured as a function of interstimulus interval
Auditory stream segregation was measured using ABA-ABA sequences where A and B were the vowel |α| and A and B differed in fundamental frequency by
- 1 November 2025
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 158 (5) , 3949-3958
Effect of masker temporal pattern, spectrum, and presentation level on speech identification
The effects of background spectral and temporal structure and overall level on the masking of speech were assessed for sentences presented in a speech-shaped noise (SSN), harmonic complex tone (HCT) (repetition period = 4.55 ms), and iterated ripple noise (IRN) (delay = 4.55 ms). The speech + noise was presented at 50 and 80 dB SPL using signal-to-noise ratios (SNRs) from 0 to −15 dB in 5-dB steps. The noises had similar spectral envelopes, but the HCT and IRN had spectral dips between peaks corresponding to the harmonic frequencies, and the HCT also had temporal dips. Especially for the SNRs of −5 and −10 dB, speech identification was best for the HCT masker and worst for the SSN, for both overall levels. For the SSN, the SNR required for 50% correct (SNR-50) was higher (worse) at 80 dB than at 50 dB, consistent with poorer frequency selectivity at the higher level. For the HCT, SNR-50 values were lower for the higher level, consistent with a better ability to “listen in the dips” at the higher level. The results indicate that the relative benefit of spectral and temporal dips varies with level.
- 1 November 2025
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 158 (5) , 3949-3958
Effect of masker temporal pattern, spectrum, and presentation level on speech identification
The effects of background spectral and temporal structure and overall level on the masking of speech were assessed for sentences presented in a speech-shaped noise (SSN), harmonic complex tone (HCT) (repetition period = 4.55 ms), and iterated ripple noise (IRN) (delay = 4.55 ms). The speech + noise was presented at 50 and 80 dB SPL using signal-to-noise ratios (SNRs) from 0 to −15 dB in 5-dB steps. The noises had similar spectral envelopes, but the HCT and IRN had spectral dips between peaks corresponding to the harmonic frequencies, and the HCT also had temporal dips. Especially for the SNRs of −5 and −10 dB, speech identification was best for the HCT masker and worst for the SSN, for both overall levels. For the SSN, the SNR required for 50% correct (SNR-50) was higher (worse) at 80 dB than at 50 dB, consistent with poorer frequency selectivity at the higher level. For the HCT, SNR-50 values were lower for the higher level, consistent with a better ability to “listen in the dips” at the higher level. The results indicate that the relative benefit of spectral and temporal dips varies with level.