VSVisa Suomi

Visa Suomi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Visa Suomi has a total of 48 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • MRI-guided transurethral ultrasound ablation for treatment of benign prostatic obstruction

    by M.H.J. Anttinen, A. Viitala, P. Mäkelä, J. Saunavaara, V. Suomi, T. Sainio, R. Blanco Sequeiros, P. Taimen, P.J. Boström

  • Acute and subacute prostate MRI findings after MRI-guided transurethral ultrasound ablation of prostate cancer

    by Pietari Mäkelä, Mikael Anttinen, Visa Suomi, Aida Steiner, Jani Saunavaara, Teija Sainio, Antero Horte, Pekka Taimen, Peter Boström, Roberto Blanco Sequeiros

    Background: Magnetic resonance imaging (MRI)-guided transurethral ultrasound ablation (TULSA) is an emerging method for treatment of localized prostate cancer (PCa). TULSA-related subacute MRI findings have not been previously characterized. Purpose: To evaluate acute and subacute MRI findings after TULSA treatment in a treat-and-resect setting. Material and Methods: Six men with newly diagnosed MRI-visible and biopsy-concordant clinically significant PCa were enrolled and completed the study. Eight lesions classified as PI-RADS 3–5 were focally ablated using TULSA. One- and three-week follow-up MRI scans were performed between TULSA and robot-assisted laparoscopic prostatectomy. Results: TULSA-related hemorrhage was detected as a subtle T1 hyperintensity and more apparent T2 hypointensity in the MRI. Both prostate volume and non-perfused volume (NPV) markedly increased after TULSA at one week and three weeks after treatment, respectively. Lesion apparent diffusion coefficient values increased one week after treatment and decreased nearing the baseline values at the three-week MRI follow-up. Conclusion: The optimal timing of MRI follow-up seems to be at the earliest at three weeks after treatment, when the post-procedural edema has decreased and the NPV has matured. Diffusion-weighted imaging has little or no added diagnostic value in the subacute setting.


  • Open Access

    Palliative MRI-guided transurethral ultrasound ablation for symptomatic locally advanced prostate cancer

    by Mikael Anttinen, Pietari Mäkelä, Pertti Nurminen, Eemil Yli-Pietilä, Visa Suomi, Teija Sainio, Jani Saunavaara, Pekka Taimen, Roberto Blanco Sequeiros, Peter J. Boström

    Locally advanced prostate cancer can cause bladder outlet obstruction, gross hematuria and frequent hospitalization. While these complications are commonly treated by palliative transurethral resec...


  • Open Access

    Oxytocin selectively reduces blood flow in uterine fibroids without an effect on myometrial blood flow: a dynamic contrast enhanced MRI evaluation

    by Saara Otonkoski, Teija Sainio, Gaber Komar, Visa Suomi, Jani Saunavaara, Roberto Blanco Sequeiros, Antti Perheentupa, Kirsi Joronen

    Uterine fibroids are the most common benign neoplasms in women. The administration of intravenous oxytocin is known to increase the efficacy of a non-invasive thermal ablation method (MR-HIFU) for ...


  • Open Access

    High-intensity focused ultrasound therapy in the uterine fibroid: a clinical case study of poor heating efficacy

    by Visa Suomi, Antti Viitala, Teija Sainio, Gaber Komar, Roberto Blanco Sequeiros

    A clinical case study of high-intensity focused ultrasound (HIFU) treatment in the uterine fibroid was conducted. During the therapy, poor heating efficacy was observed which could be attributed to several factors such as the local perfusion rate, patient-specific anatomy or changes in acoustic parameters of the ultrasound field. In order to determine the cause of the diminished heating, perfusion analyses and ultrasound simulations were conducted using the magnetic resonance imaging (MRI) data from the treatment. The perfusion analysis showed high local perfusion rate in the myoma (301.0 +- 25.6 mL/100 g/min) compared to the surrounding myometrium (233.8 +- 16.2 mL/100 g/min). The ultrasound simulations did not show large differences in the focal point shape or the acoustic pressure (2.07 +- 0.06 MPa) when tilting the transducer. However, a small shift (-2.2 +- 1.3 mm) in the axial location of the focal point was observed. The main causes for the diminished heating were likely the high local perfusion and ultrasound attenuation due to the deep location of the myoma.

  • Open Access

    Comprehensive feature selection for classifying the treatment outcome of high-intensity ultrasound therapy in uterine fibroids

    by Visa Suomi, Gaber Komar, Teija Sainio, Kirsi Joronen, Antti Perheentupa, Roberto Blanco Sequeiros

    The study aim was to utilise multiple feature selection methods in order to select the most important parameters from clinical patient data for high-intensity focused ultrasound (HIFU) treatment outcome classification in uterine fibroids. The study was retrospective using patient data from 66 HIFU treatments with 89 uterine fibroids. A total of 39 features were extracted from the patient data and 14 different filter-based feature selection methods were used to select the most informative features. The selected features were then used in a support vector classification (SVC) model to evaluate the performance of these parameters in predicting HIFU therapy outcome. The therapy outcome was defined as non-perfused volume (NPV) ratio in three classes: 80%. The ten most highly ranked features in order were: fibroid diameter, subcutaneous fat thickness, fibroid volume, fibroid distance, Funaki type I, fundus location, gravidity, Funaki type III, submucosal fibroid type and urinary symptoms. The maximum F1-micro classification score was 0.63 using the top ten features from Mutual Information Maximisation (MIM) and Joint Mutual Information (JMI) feature selection methods. Classification performance of HIFU therapy outcome prediction in uterine fibroids is highly dependent on the chosen feature set which should be determined prior using different classifiers.

  • Open Access

    Transurethral ultrasound therapy of the prostate in the presence of calcifications: A simulation study

    by Visa Suomi, Bradley Treeby, Jiri Jaros, Pietari Makela, Mikael Anttinen, Jani Saunavaara, Teija Sainio, Aida Kiviniemi, Roberto Blanco

    Purpose: Transurethral ultrasound therapy is an investigational treatment modality which could potentially be used for the localized treatment of prostate cancer. One of the limiting factors of this therapy is prostatic calcifications. These attenuate and reflect ultrasound and thus reduce the efficacy of the heating. The aim of this study is to investigate how prostatic calcifications affect therapeutic efficacy, and to identify the best sonication strategy when calcifications are present. Methods: Realistic computational models were used on clinical patient data in order to simulate different therapeutic situations with naturally occurring calcifications as well as artificial calcifications of different sizes (1-10 mm) and distances (5-15 mm). Furthermore, different sonication strategies were tested in order to deliver therapy to the untreated tissue regions behind the calcifications. Results: The presence of calcifications in front of the ultrasound field was found to increase the peak pressure by 100% on average while the maximum temperature only rose by 9% during a 20-s sonication. Losses in ultrasound energy were due to the relatively large acoustic impedance mismatch between the prostate tissue and the calcifications (1.63 vs 3.20 MRayl) and high attenuation coefficient (0.78 vs 2.64 dB/MHz^1.1/cm), which together left untreated tissue regions behind the calcifications. In addition, elevated temperatures were seen in the region between the transducer and the calcifications. Lower sonication frequencies (1-4 MHz) were not able to penetrate through the calcifications effectively, but longer sonication durations (20-60 s) with selective transducer elements were effective in treating the tissue regions behind the calcifications.

  • Open Access

    Feasibility of MRI-guided transurethral ultrasound for lesion-targeted ablation of prostate cancer

    by Mikael Anttinen, Pietari Mäkelä, Visa Suomi, Aida Kiviniemi, Jani Saunavaara, Teija Sainio, Antero Horte, Lauri Eklund, Pekka Taimen, Roberto Blanco Sequeiros, et al.


  • Open Access

    Comprehensive feature selection for classifying the treatment outcome of high-intensity ultrasound therapy in uterine fibroids

    by Visa Suomi, Gaber Komar, Teija Sainio, Kirsi Joronen, Antti Perheentupa, Roberto Blanco Sequeiros

    The study aim was to utilise multiple feature selection methods in order to select the most important parameters from clinical patient data for high-intensity focused ultrasound (HIFU) treatment outcome classification in uterine fibroids. The study was retrospective using patient data from 66 HIFU treatments with 89 uterine fibroids. A total of 39 features were extracted from the patient data and 14 different filter-based feature selection methods were used to select the most informative features. The selected features were then used in a support vector classification (SVC) model to evaluate the performance of these parameters in predicting HIFU therapy outcome. The therapy outcome was defined as non-perfused volume (NPV) ratio in three classes: 80%. The ten most highly ranked features in order were: fibroid diameter, subcutaneous fat thickness, fibroid volume, fibroid distance, Funaki type I, fundus location, gravidity, Funaki type III, submucosal fibroid type and urinary symptoms. The maximum F1-micro classification score was 0.63 using the top ten features from Mutual Information Maximisation (MIM) and Joint Mutual Information (JMI) feature selection methods. Classification performance of HIFU therapy outcome prediction in uterine fibroids is highly dependent on the chosen feature set which should be determined prior using different classifiers.