EAEhab Abou-Bakr

Ehab Abou-Bakr

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ehab Abou-Bakr has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Evaluating the Accuracy of Medical Information Generated by ChatGPT and Gemini and Its Alignment With International Clinical Guidelines From the Surviving Sepsis Campaign: Comparative Study

    by Dina Kutbi, Ehab Abou-Bakr, Hassan Mousa Haidar

    Background: Assessment of medical information provided by artificial intelligence (AI) chatbots like ChatGPT and Google’s Gemini and comparison with international guidelines is a burgeoning area of research. These AI models are increasingly being considered for their potential to support clinical decision-making and patient education. However, their accuracy and reliability in delivering medical information that aligns with established guidelines remain under scrutiny. Objective: This study aims to assess the accuracy of medical information generated by ChatGPT and Gemini and its alignment with international guidelines for sepsis management. Methods: ChatGPT and Gemini were asked 18 questions about the Surviving Sepsis Campaign guidelines, and the responses were evaluated by 7 independent intensive care physicians. The responses generated were scored as follows: 3=correct, complete, and accurate; 2=correct but incomplete or inaccurate; and 1=incorrect. This scoring system was chosen to provide a clear and straightforward assessment of the accuracy and completeness of the responses. The Fleiss κ test was used to assess the agreement between evaluators, and the Mann-Whitney U test was used to test for the significance of differences between the correct responses generated by ChatGPT and Gemini. Results: ChatGPT provided 5 (28%) perfect responses, 12 (67%) nearly perfect responses, and 1 (5%) low-quality response, with substantial agreement among the evaluators (Fleiss κ=0.656). Gemini, on the other hand, provided 3 (17%) perfect responses, 14 (78%) nearly perfect responses, and 1 (5%) low-quality response, with moderate agreement among the evaluators (Fleiss κ=0.582). The Mann-Whitney U test revealed no statistically significant difference between the two platforms (P=.48). Conclusions: ChatGPT and Gemini both demonstrated potential for generating medical information. Despite their current limitations, both showed promise as complementary tools in patient education and clinical decision-making. The medical information generated by ChatGPT and Gemini still needs ongoing evaluation regarding its accuracy and alignment with international guidelines in different medical domains, particularly in the sepsis field.


  • Open Access

    Evaluating the Accuracy of Medical Information Generated by ChatGPT and Gemini and Its Alignment With International Clinical Guidelines From the Surviving Sepsis Campaign: Comparative Study (Preprint)

    by Dina Kutbi, Ehab Abou-Bakr, Hassan Mousa Haidar

    BACKGROUND Assessment of medical information provided by artificial intelligence (AI) chatbots like ChatGPT and Google’s Gemini and comparison with international guidelines is a burgeoning area of research. These AI models are increasingly being considered for their potential to support clinical decision-making and patient education. However, their accuracy and reliability in delivering medical information that aligns with established guidelines remain under scrutiny. OBJECTIVE This study aims to assess the accuracy of medical information generated by ChatGPT and Gemini and its alignment with international guidelines for sepsis management. METHODS ChatGPT and Gemini were asked 18 questions about the Surviving Sepsis Campaign guidelines, and the responses were evaluated by 7 independent intensive care physicians. The responses generated were scored as follows: 3=correct, complete, and accurate; 2=correct but incomplete or inaccurate; and 1=incorrect. This scoring system was chosen to provide a clear and straightforward assessment of the accuracy and completeness of the responses. The Fleiss κ test was used to assess the agreement between evaluators, and the Mann-Whitney U test was used to test for the significance of differences between the correct responses generated by ChatGPT and Gemini. RESULTS ChatGPT provided 5 (28%) perfect responses, 12 (67%) nearly perfect responses, and 1 (5%) low-quality response, with substantial agreement among the evaluators (Fleiss κ=0.656). Gemini, on the other hand, provided 3 (17%) perfect responses, 14 (78%) nearly perfect responses, and 1 (5%) low-quality response, with moderate agreement among the evaluators (Fleiss κ=0.582). The Mann-Whitney U test revealed no statistically significant difference between the two platforms (P=.48). CONCLUSIONS ChatGPT and Gemini both demonstrated potential for generating medical information. Despite their current limitations, both showed promise as complementary tools in patient education and clinical decision-making. The medical information generated by ChatGPT and Gemini still needs ongoing evaluation regarding its accuracy and alignment with international guidelines in different medical domains, particularly in the sepsis field.

  • Open Access

    Hybrid Chaotic-Based PRNG for Secure Cryptography Applications

    by Abdullah M. Alnajim, Ehab Abou-Bakr, Sarah S. Alruwisan, Sheroz Khan, Rania A. Elmanfaloty

    This paper suggests a novel one-dimensional (1D) map to address the limitations of traditional chaotic 1D maps. In contrast to traditional 1D maps, the proposed map has three control parameters a, μ, and c, allowing it to exhibit chaotic behavior over a wide range of values. The dynamic behavior of the new 1D map was analyzed using well-known numerical methods, including the bifurcation diagram and Lyapunov exponent. Both tests showed their complex and diverse behavior. In addition, a novel image encryption scheme was devised using the new function as its pseudorandom number generator. Rigorous statistical testing was applied to the proposed encryption algorithm. The mean square error (MSE) and peak signal-to-noise ratio (PSNR) results, in addition to subjecting 28 images to number of pixels change rate (NPCR) and unified average changing intensity (UACI) tests demonstrated the robustness of the system. The results of this study demonstrate the effectiveness of the new 1D map for use in secure image cryptography applications, providing a more robust and secure alternative to traditional chaotic 1D maps.


  • Open Access

    A Finite Precision Implementation of an Image Encryption Scheme Based on DNA Encoding and Binarized Chaotic Cores

    by Rania A. Elmanfaloty, Abdullah M. Alnajim, Ehab Abou-Bakr

    One dimensional chaotic maps suffer from limited number of control parameters and converged periodicity, specially under finite precision implementation, making them unsuitable for hardware based ciphering systems. This paper first discusses the limited periodicity of 1D maps under fixed point precision, then, an image encryption algorithm based on DNA encoding and two specially configured binarized chaotic cores is presented. The function of both cores is to perform the confusion and diffusion stages of the image by generating pseudo random numbers with excellent cryptographic properties. DNA encoding adds an extra layer of security to the algorithm by converting both the image and chaotic stream to DNA sequences using specific DNA encoding rule. Initial values of both chaotic cores are image dependent based on a calculated hamming distance. These initial condition and the utilized DNA rules composes the overall secret key of the system with a total length of 336 bits. On the condition that all calculations involved in the scheme are based on binary integer arithmetic, all performed security analysis subjected to the scheme proved the system to withstand known attacks with excellent encryption properties.


  • Open Access

    An Image Encryption Scheme Using a 1D Chaotic Double Section Skew Tent Map

    by Rania A. Elmanfaloty, Ehab Abou-Bakr

    Because of their complex behaviour, simple mathematical and digital hardware representation, one-dimensional (1D) chaotic functions were the earliest choices of cryptologists for applying chaos theory to cryptography. It was discovered later that most of these functions suffer from orbits collapsing into a specific period, especially under finite precision realization and weakness because of their limited number of control parameter(s). This in turn exposed many security issues and was proven to be vulnerable to various types of attacks. This paper addresses the issue of limited number of control parameters by introducing a 1D chaotic function with five control parameters (in addition to the initial condition). Analysis of the function implies its chaotic properties in addition to its ability to generate a cryptographically secured random stream of numbers. To further elaborate on its robustness, a new image encryption algorithm incorporating the function as its random number generator is presented. Various analyses of the new scheme confirm it to be secure with good confusion-diffusion properties.


  • A new visualization technique to design a wideband LNA

    by A.A.A. Nasser, M. R. M. Rizk, Ehab Abou-Bakr, El-Sayed A. El-Badawy, Amr M. Mahros

    For a minimum noise figure (NFmin) operation, this paper presents a new graphical model that characterizes the boundaries of the transducer gain (GT) for an unconditionally stable transistor. First, a full visual view of the transistor operating at minimum noise figure (NFmin) is given. Second, the transistor operating capacity is determined through monitoring both the GT and the voltage standing wave ratio (VSWR). This will aid designers identify suitable transistors according to the required design goals. The model is based on constructing a database to be used for visual representation and fetching appropriate matching impedances for design purposes. A validation is done by using the proposed matching procedure to update circuit component values of a low noise amplifier (LNA) given in literature. The simulation results after update compares favourably with those of the original circuit. Moreover, noticeable improvement in gain flatness, NF and VSWR were achieved.

  • Full characterization of gain and noise boundaries for NFmin or unity SWRout operation

    by M. R. M. Rizk, Ehab Abou-Bakr, A. A. A. Nasser, El-Sayed A. El-Badawy, Amr M. Mahros

  • On the investigation of voltage standing wave ratio to design a low noise wideband microwave amplifier

    by M. R. M. Rizk, Ehab Abou-Bakr, A.A.A. Nasser, El-Sayed A. El-Badawy, Amr M. Mahros

    In this paper, a new trend in the design of a microwave amplifier is proposed. The pivot element in the design is to numerically investigate the the relation between VSWR with different frequencies, reflection coefficients, and noise figures. Multiple curves relating the VSWR with both the reflection coefficient and the transducer gain facilitates the location of a starting point for the optimization process involved in the design of microwave amplifiers. The designs obtained by the proposed procedure proved to be accurate and simple.