David S. Paik
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
David S. Paik has a total of 78 co-authors. Here are the top co-authors by number of shared publications:
- Sandy Napel
Stanford University
5 shared publications - Geoffrey D. Rubin
University of Arizona College of Medicine
3 shared publications R. Brooke Jeffrey
3 shared publicationsChristopher F. Beaulieu
2 shared publications- Dean W. Felsher
Stanford University
2 shared publications - Juli D. Klemm
Center for Strategic Scientific Initiatives, National Cancer Institute, NIH, Bethesda, Maryland. 1
2 shared publications
Latest Publications
- 1 January 2019
- Published by Elsevier in Computerized Medical Imaging and Graphics
- Vol. 71, 1-8
Machine learning to predict lung nodule biopsy method using CT image features: A pilot study
- 1 January 2019
- Published by Elsevier in Computerized Medical Imaging and Graphics
- Vol. 71, 1-8
Machine learning to predict lung nodule biopsy method using CT image features: A pilot study
- 1 July 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2013 (1094687X) , 4529-4532
A tumor-immune mathematical model of CD4+ T helper cell dependent tumor regression by oncogene inactivation
Understanding the complex dynamics between the tumor cells and the host immune system will be key to improved therapeutic strategies against cancer. We propose an ODE-based mathematical model of both the tumor and immune system and how they respond to inactivation of the driving oncogene. Our model supports experimental results showing that cellular senescence of tumor cells is dependent on CD4+ T helper cells, leading to relapse of tumors in immunocompromised hosts.
- 1 July 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2013 (1094687X) , 4529-4532
A tumor-immune mathematical model of CD4+ T helper cell dependent tumor regression by oncogene inactivation
Understanding the complex dynamics between the tumor cells and the host immune system will be key to improved therapeutic strategies against cancer. We propose an ODE-based mathematical model of both the tumor and immune system and how they respond to inactivation of the driving oncogene. Our model supports experimental results showing that cellular senescence of tumor cells is dependent on CD4+ T helper cells, leading to relapse of tumors in immunocompromised hosts.
- Open Access
- 14 January 2013
- Published by Springer Nature in BMC Biotechnology
- Vol. 13 (1) , 2
ISA-TAB-Nano: A Specification for Sharing Nanomaterial Research Data in Spreadsheet-based Format
Background and motivation: The high-throughput genomics communities have been successfully using standardized spreadsheet-based formats to capture and share data within labs and among public repositories. The nanomedicine community has yet to adopt similar standards to share the diverse and multi-dimensional types of data (including metadata) pertaining to the description and characterization of nanomaterials. Owing to the lack of standardization in representing and sharing nanomaterial data, most of the data currently shared via publications and data resources are incomplete, poorly-integrated, and not suitable for meaningful interpretation and re-use of the data. Specifically, in its current state, data cannot be effectively utilized for the development of predictive models that will inform the rational design of nanomaterials. Results: We have developed a specification called ISA-TAB-Nano, which comprises four spreadsheet-based file formats for representing and integrating various types of nanomaterial data. Three file formats (Investigation, Study, and Assay files) have been adapted from the established ISA-TAB specification; while the Material file format was developed de novo to more readily describe the complexity of nanomaterials and associated small molecules. In this paper, we have discussed the main features of each file format and how to use them for sharing nanomaterial descriptions and assay metadata. Conclusion: The ISA-TAB-Nano file formats provide a general and flexible framework to record and integrate nanomaterial descriptions, assay data (metadata and endpoint measurements) and protocol information. Like ISA-TAB, ISA-TAB-Nano supports the use of ontology terms to promote standardized descriptions and to facilitate search and integration of the data. The ISA-TAB-Nano specification has been submitted as an ASTM work item to obtain community feedback and to provide a nanotechnology data-sharing standard for public development and adoption.
- 14 January 2013
- Published by Springer Nature in BMC Biotechnology
- Vol. 13 (1) , 2
Open AccessISA-TAB-Nano: A Specification for Sharing Nanomaterial Research Data in Spreadsheet-based Format
Background and motivation: The high-throughput genomics communities have been successfully using standardized spreadsheet-based formats to capture and share data within labs and among public repositories. The nanomedicine community has yet to adopt similar standards to share the diverse and multi-dimensional types of data (including metadata) pertaining to the description and characterization of nanomaterials. Owing to the lack of standardization in representing and sharing nanomaterial data, most of the data currently shared via publications and data resources are incomplete, poorly-integrated, and not suitable for meaningful interpretation and re-use of the data. Specifically, in its current state, data cannot be effectively utilized for the development of predictive models that will inform the rational design of nanomaterials. Results: We have developed a specification called ISA-TAB-Nano, which comprises four spreadsheet-based file formats for representing and integrating various types of nanomaterial data. Three file formats (Investigation, Study, and Assay files) have been adapted from the established ISA-TAB specification; while the Material file format was developed de novo to more readily describe the complexity of nanomaterials and associated small molecules. In this paper, we have discussed the main features of each file format and how to use them for sharing nanomaterial descriptions and assay metadata. Conclusion: The ISA-TAB-Nano file formats provide a general and flexible framework to record and integrate nanomaterial descriptions, assay data (metadata and endpoint measurements) and protocol information. Like ISA-TAB, ISA-TAB-Nano supports the use of ontology terms to promote standardized descriptions and to facilitate search and integration of the data. The ISA-TAB-Nano specification has been submitted as an ASTM work item to obtain community feedback and to provide a nanotechnology data-sharing standard for public development and adoption.
- 14 March 2012
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 43 (7) , 895-905
Raman labeled nanoparticles: characterization of variability and improved method for unmixing
- 14 March 2012
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 43 (7) , 895-905
Raman labeled nanoparticles: characterization of variability and improved method for unmixing
- 5 October 2011
- Published by American Association for the Advancement of Science (AAAS) in Science Translational Medicine
- Vol. 3 (103) , 103ra99
Survival and Death Signals Can Predict Tumor Response to Therapy After Oncogene Inactivation
Modeling survival and death signaling in tumors by combining quantitative imaging and in situ biomarker analysis can be used to predict responses to therapy after oncogene inactivation.
- 5 October 2011
- Published by American Association for the Advancement of Science (AAAS) in Science Translational Medicine
- Vol. 3 (103) , 103ra99
Survival and Death Signals Can Predict Tumor Response to Therapy After Oncogene Inactivation
Modeling survival and death signaling in tumors by combining quantitative imaging and in situ biomarker analysis can be used to predict responses to therapy after oncogene inactivation.
- 30 June 2011
- Published by Wiley in WIREs Nanomedicine and Nanobiotechnology
- Vol. 3 (5) , 511-532
Informatics and standards for nanomedicine technology
There are several issues to be addressed concerning the management and effective use of information (or data), generated from nanotechnology studies in biomedical research and medicine. These data are large in volume, diverse in content, and are beset with gaps and ambiguities in the description and characterization of nanomaterials. In this work, we have reviewed three areas of nanomedicine informatics: information resources; taxonomies, controlled vocabularies, and ontologies; and information standards. Informatics methods and standards in each of these areas are critical for enabling collaboration; data sharing; unambiguous representation and interpretation of data; semantic (meaningful) search and integration of data; and for ensuring data quality, reliability, and reproducibility. In particular, we have considered four types of information standards in this article, which are standard characterization protocols, common terminology standards, minimum information standards, and standard data communication (exchange) formats. Currently, because of gaps and ambiguities in the data, it is also difficult to apply computational methods and machine learning techniques to analyze, interpret, and recognize patterns in data that are high dimensional in nature, and also to relate variations in nanomaterial properties to variations in their chemical composition, synthesis, characterization protocols, and so on. Progress toward resolving the issues of information management in nanomedicine using informatics methods and standards discussed in this article will be essential to the rapidly growing field of nanomedicine informatics. WIREs Nanomed Nanobiotechnol 2011 3 511–532 DOI: 10.1002/wnan.152This article is categorized under: Therapeutic Approaches and Drug Discovery > Emerging Technologies Toxicology and Regulatory Issues in Nanomedicine > Regulatory and Policy Issues in Nanomedicine
- 30 June 2011
- Published by Wiley in WIREs Nanomedicine and Nanobiotechnology
- Vol. 3 (5) , 511-532
Informatics and standards for nanomedicine technology
There are several issues to be addressed concerning the management and effective use of information (or data), generated from nanotechnology studies in biomedical research and medicine. These data are large in volume, diverse in content, and are beset with gaps and ambiguities in the description and characterization of nanomaterials. In this work, we have reviewed three areas of nanomedicine informatics: information resources; taxonomies, controlled vocabularies, and ontologies; and information standards. Informatics methods and standards in each of these areas are critical for enabling collaboration; data sharing; unambiguous representation and interpretation of data; semantic (meaningful) search and integration of data; and for ensuring data quality, reliability, and reproducibility. In particular, we have considered four types of information standards in this article, which are standard characterization protocols, common terminology standards, minimum information standards, and standard data communication (exchange) formats. Currently, because of gaps and ambiguities in the data, it is also difficult to apply computational methods and machine learning techniques to analyze, interpret, and recognize patterns in data that are high dimensional in nature, and also to relate variations in nanomaterial properties to variations in their chemical composition, synthesis, characterization protocols, and so on. Progress toward resolving the issues of information management in nanomedicine using informatics methods and standards discussed in this article will be essential to the rapidly growing field of nanomedicine informatics. WIREs Nanomed Nanobiotechnol 2011 3 511–532 DOI: 10.1002/wnan.152This article is categorized under: Therapeutic Approaches and Drug Discovery > Emerging Technologies Toxicology and Regulatory Issues in Nanomedicine > Regulatory and Policy Issues in Nanomedicine
- 22 April 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Visualization and Computer Graphics
- Vol. 17 (1) , 115-124
Shape “Break-and-Repair” Strategy and Its Application to Automated Medical Image Segmentation
In three-dimensional medical imaging, segmentation of specific anatomy structure is often a preprocessing step for computer-aided detection/diagnosis (CAD) purposes, and its performance has a significant impact on diagnosis of diseases as well as objective quantitative assessment of therapeutic efficacy. However, the existence of various diseases, image noise or artifacts, and individual anatomical variety generally impose a challenge for accurate segmentation of specific structures. To address these problems, a shape analysis strategy termed “break-and-repair” is presented in this study to facilitate automated medical image segmentation. Similar to surface approximation using a limited number of control points, the basic idea is to remove problematic regions and then estimate a smooth and complete surface shape by representing the remaining regions with high fidelity as an implicit function. The innovation of this shape analysis strategy is the capability of solving challenging medical image segmentation problems in a unified framework, regardless of the variability of anatomical structures in question. In our implementation, principal curvature analysis is used to identify and remove the problematic regions and radial basis function (RBF) based implicit surface fitting is used to achieve a closed (or complete) surface boundary. The feasibility and performance of this strategy are demonstrated by applying it to automated segmentation of two completely different anatomical structures depicted on CT examinations, namely human lungs and pulmonary nodules. Our quantitative experiments on a large number of clinical CT examinations collected from different sources demonstrate the accuracy, robustness, and generality of the shape “break-and-repair” strategy in medical image segmentation.
- 22 April 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Visualization and Computer Graphics
- Vol. 17 (1) , 115-124
Shape “Break-and-Repair” Strategy and Its Application to Automated Medical Image Segmentation
In three-dimensional medical imaging, segmentation of specific anatomy structure is often a preprocessing step for computer-aided detection/diagnosis (CAD) purposes, and its performance has a significant impact on diagnosis of diseases as well as objective quantitative assessment of therapeutic efficacy. However, the existence of various diseases, image noise or artifacts, and individual anatomical variety generally impose a challenge for accurate segmentation of specific structures. To address these problems, a shape analysis strategy termed “break-and-repair” is presented in this study to facilitate automated medical image segmentation. Similar to surface approximation using a limited number of control points, the basic idea is to remove problematic regions and then estimate a smooth and complete surface shape by representing the remaining regions with high fidelity as an implicit function. The innovation of this shape analysis strategy is the capability of solving challenging medical image segmentation problems in a unified framework, regardless of the variability of anatomical structures in question. In our implementation, principal curvature analysis is used to identify and remove the problematic regions and radial basis function (RBF) based implicit surface fitting is used to achieve a closed (or complete) surface boundary. The feasibility and performance of this strategy are demonstrated by applying it to automated segmentation of two completely different anatomical structures depicted on CT examinations, namely human lungs and pulmonary nodules. Our quantitative experiments on a large number of clinical CT examinations collected from different sources demonstrate the accuracy, robustness, and generality of the shape “break-and-repair” strategy in medical image segmentation.
- 1 June 2006
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 239 (3) , 768-776
CT Colonography: Influence of 3D Viewing and Polyp Candidate Features on Interpretation with Computer-aided Detection
To retrospectively determine if three-dimensional (3D) viewing improves radiologists' accuracy in classifying true-positive (TP) and false-positive (FP) polyp candidates identified with computer-aided detection (CAD) and to determine candidate polyp features that are associated with classification accuracy, with known polyps serving as the reference standard. Institutional review board approval and informed consent were obtained; this study was HIPAA compliant. Forty-seven computed tomographic (CT) colonography data sets were obtained in 26 men and 10 women (age range, 42-76 years). Four radiologists classified 705 polyp candidates (53 TP candidates, 652 FP candidates) identified with CAD; initially, only two-dimensional images were used, but these were later supplemented with 3D rendering. Another radiologist unblinded to colonoscopy findings characterized the features of each candidate, assessed colon distention and preparation, and defined the true nature of FP candidates. Receiver operating characteristic curves were used to compare readers' performance, and repeated-measures analysis of variance was used to test features that affect interpretation. Use of 3D viewing improved classification accuracy for three readers and increased the area under the receiver operating characteristic curve to 0.96-0.97 (P<.001). For TP candidates, maximum polyp width (P=.038), polyp height (P=.019), and preparation (P=.004) significantly affected accuracy. For FP candidates, colonic segment (P=.007), attenuation (P<.001), surface smoothness (P<.001), distention (P=.034), preparation (P<.001), and true nature of candidate lesions (P<.001) significantly affected accuracy. Use of 3D viewing increases reader accuracy in the classification of polyp candidates identified with CAD. Polyp size and examination quality are significantly associated with accuracy.
- 1 June 2006
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 239 (3) , 768-776
CT Colonography: Influence of 3D Viewing and Polyp Candidate Features on Interpretation with Computer-aided Detection
To retrospectively determine if three-dimensional (3D) viewing improves radiologists' accuracy in classifying true-positive (TP) and false-positive (FP) polyp candidates identified with computer-aided detection (CAD) and to determine candidate polyp features that are associated with classification accuracy, with known polyps serving as the reference standard. Institutional review board approval and informed consent were obtained; this study was HIPAA compliant. Forty-seven computed tomographic (CT) colonography data sets were obtained in 26 men and 10 women (age range, 42-76 years). Four radiologists classified 705 polyp candidates (53 TP candidates, 652 FP candidates) identified with CAD; initially, only two-dimensional images were used, but these were later supplemented with 3D rendering. Another radiologist unblinded to colonoscopy findings characterized the features of each candidate, assessed colon distention and preparation, and defined the true nature of FP candidates. Receiver operating characteristic curves were used to compare readers' performance, and repeated-measures analysis of variance was used to test features that affect interpretation. Use of 3D viewing improved classification accuracy for three readers and increased the area under the receiver operating characteristic curve to 0.96-0.97 (P<.001). For TP candidates, maximum polyp width (P=.038), polyp height (P=.019), and preparation (P=.004) significantly affected accuracy. For FP candidates, colonic segment (P=.007), attenuation (P<.001), surface smoothness (P<.001), distention (P=.034), preparation (P<.001), and true nature of candidate lesions (P<.001) significantly affected accuracy. Use of 3D viewing increases reader accuracy in the classification of polyp candidates identified with CAD. Polyp size and examination quality are significantly associated with accuracy.
- 18 September 2003
- Published by Wiley in Medical Physics
- Vol. 30 (10) , 2663-2674
CT colonography: Does improvedzresolution help computer-aided polyp detection?
Multislice helical CT offers several retrospective choices of longitudinal (z) resolution at a given detector collimation setting. We sought to determine the effect of z resolution on the performance of a computer-aided colonic polyp detector, since a human reader and a computer-aided polyp detector may have optimal performances at different z resolutions. We ran a computer-aided polyp detection algorithm on phantom data sets as well as data obtained from a single patient. All data were reconstructed at various slice thicknesses ranging from 1.25 to 10 mm. We studied the performance of the detector at various ranges of polyp sizes using free-response receiver-operating characteristic analyses. We also studied contrast-to-noise ratios (CNR) as a function of slice thickness and polyp size. For the phantom data, reducing the slice thickness from 5 to 1.25 mm improves sensitivity from 84.5% to 98.3% (all polyps), from 61.4% to 95.5% (polyps in the range [0, 5) mm) and from 97.7% to 100% (polyps in the range [5, 10) mm) at a false positive rate of 20 per data set. For polyps larger than 10 mm, there is no significant improvement in detection sensitivity when slice thickness is reduced. CNRs showed expected behavior with slice thickness and polyp size, but in all cases remained high (> 4). The results for the patient data followed similar patterns to that of the phantom case. Thus we conclude that for this detector, the optimal slice thickness is dependent upon the size of the smallest polyps to be detected. For detection of polyps 10 mm and larger, reconstruction of 5 mm sections may be sufficient. Further study is required to generalize these results to a broader population of patients scanned on different scanners.
- 18 September 2003
- Published by Wiley in Medical Physics
- Vol. 30 (10) , 2663-2674
CT colonography: Does improvedzresolution help computer-aided polyp detection?
Multislice helical CT offers several retrospective choices of longitudinal (z) resolution at a given detector collimation setting. We sought to determine the effect of z resolution on the performance of a computer-aided colonic polyp detector, since a human reader and a computer-aided polyp detector may have optimal performances at different z resolutions. We ran a computer-aided polyp detection algorithm on phantom data sets as well as data obtained from a single patient. All data were reconstructed at various slice thicknesses ranging from 1.25 to 10 mm. We studied the performance of the detector at various ranges of polyp sizes using free-response receiver-operating characteristic analyses. We also studied contrast-to-noise ratios (CNR) as a function of slice thickness and polyp size. For the phantom data, reducing the slice thickness from 5 to 1.25 mm improves sensitivity from 84.5% to 98.3% (all polyps), from 61.4% to 95.5% (polyps in the range [0, 5) mm) and from 97.7% to 100% (polyps in the range [5, 10) mm) at a false positive rate of 20 per data set. For polyps larger than 10 mm, there is no significant improvement in detection sensitivity when slice thickness is reduced. CNRs showed expected behavior with slice thickness and polyp size, but in all cases remained high (> 4). The results for the patient data followed similar patterns to that of the phantom case. Thus we conclude that for this detector, the optimal slice thickness is dependent upon the size of the smallest polyps to be detected. For detection of polyps 10 mm and larger, reconstruction of 5 mm sections may be sufficient. Further study is required to generalize these results to a broader population of patients scanned on different scanners.
- 1 February 2002
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 222 (2) , 560-563
Carotid Disease: Automated Analysis with Cardiac-gated Three-dimensional US—Technique and Preliminary Results
- 1 February 2002
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 222 (2) , 560-563
Carotid Disease: Automated Analysis with Cardiac-gated Three-dimensional US—Technique and Preliminary Results