JWJames A. Whitby

James A. Whitby

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


James A. Whitby has a total of 111 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Chemical and Mechanical Correlative Mapping: Combining FIB-SIMS with Nanoindenter Hardness Measurements

    by Seiichi Shimizu, Lex Pillatsch, Valentine Riedo-Grimaudo, James A. Whitby, Renato Pero, Nicholas X. Randall

    Combining images of the same sample obtained from several spectroscopic techniques has become a standard approach for comprehensive material characterization. However, integrating mechanical properties mapping into these workflow remains less common. Here, we show an example of combining two relatively recent technologies for in vacuo characterization of samples at sub-micron spatial resolution: nano-indentation and Secondary Ion Mass Spectrometry (SIMS) using the combination of the Focused Ion Beam (FIB) from a FIB-SEM with a time-of-flight (TOF) mass analyzer. Methodology: The sample under investigation is an M3 high-speed steel, characterized by a microstructure consisting of primary carbides (MC and M6C) distributed in a martensitic matrix. Grains of MnS are embedded in the Fe matrix, included to provide solid lubrication for improved machinability. The sample was polished using 0.25 µm alumina abrasive. Secondary ion images were acquired using TOFWERK’s fibTOF secondary ion mass spectrometry detector on a Tescan Lyra FIB-SEM microscope equipped with a gallium ion source, operating at 30 keV FIB beam energy and 1.1 nA beam current [ 1, 2]. Nanoindentation was performed using an ALEMNIS ASA in fast mapping mode, using the grid indentation technique [ 3]. Results: The large (many microns) grains of MnS were clearly visible in both the SIMS maps (see Fig. 1d, and Fig. 1h) and the hardness map ( Fig. 1e). The SIMS maps revealed the distribution of the minor elements such as vanadium and molybdenum. While the vanadium distribution seemed not to correlate with features in the hardness map, a clear correlation was observed between molybdenum SIMS map and hardness values. The fibTOF SIMS detector identified several areas (likely a single phase) apparently enriched in hydrogen; these regions (not shown) exhibited higher carbon signals in SIMS maps. However, the interpretation of SIMS data requires caution due to large matrix effects. Conclusions: The interest in combining mechanical measurements with chemical maps is clear. For specimens requiring high lateral resolution and/or the detection of minor, traces or light elements, the combination of in-situ nanoindentation with SIMS offers an attractive alternative to EDS. FIB-SIMS provides a technical pathway for such combination. In the near future, we plan to demonstrate in situ measurements using both SIMS and the nanoindenter without the need to transfer samples between microscope chambers. Fig. 1. M3 high speed-steel alloy. a) FIB secondary electron image of the analyzed area b)-d) and f)-h) secondary ion intensity maps e) hardness map.

  • FIB-SIMS in FIB-SEMs—Practical Aspects for Physical Failure Analysis

    by Heiko Stegmann, Hubert Schulz, James Whitby

  • DESIGN AND PERFORMANCE OF TWO ORTHOGONAL EXTRACTION TIME-OF-FLIGHT SECONDARY ION MASS SPECTROMETERS FOR FOCUSED ION BEAM INSTRUMENTS

    by Deborah Alberts, Leandro von Werra, Fredrik Oestlund, Urs Rohner, Markus Hohl, Johann Michler, James A. Whitby

    The design and performance of two orthogonal extraction time-of-flight mass spectrometers are reported that were adapted to existing focused ion beam microscopes for secondary ion mass spectrometry. The performances of these designs were compared to that of a prototype previously described by our group. The differences include newly designed transfer ion optics and in the use of a larger microscope chamber. The two new prototypes allow a mass resolving power of either 600 Th/Th (compact design) or 3000 Th/Th (high resolution design) while simultaneously achieving a lateral spatial resolution of less than 50 nm. The spectrometers and their performance (effective ion yield, mass resolving power, lateral, and depth resolution) are described and compared. Additionally, example applications are presented with multivariate statistical methods to visualize the data sets. Both time-of-flight mass analyzers use orthogonal extraction which avoids the need to pulse the primary ion beam, and the of use monoisotopic gallium to preserve the mass resolution. The goal of the design was a cost-effective accessory to augment typical focused ion beam-scanning electron microscopy applications as an alternative to the cost of a dedicated secondary ion mass spectrometer. The modified instrument allows excellent non destructive imaging and easy sample access, and benefits from the presence of complementary non destructive analytical and imaging techniques that exploit the presence of an electron microscope.


  • Open Access

    High Spatial Resolution Time-of-Flight Secondary Ion Mass Spectrometry for the Masses: A Novel Orthogonal ToF FIB-SIMS Instrument withIn SituAFM

    by James A. Whitby, Fredrik Östlund, Peter Horvath, Mihai Gabureac, Jessica L. Riesterer, Ivo Utke, Markus Hohl, Libor Sedláček, Jaroslav Jiruše, Vinzenz Friedli, et al.

    We describe the design and performance of an orthogonal time-of-flight (TOF) secondary ion mass spectrometer that can be retrofitted to existing focused ion beam (FIB) instruments. In particular, a simple interface has been developed for FIB/SEM instruments from the manufacturer Tescan. Orthogonal extraction to the mass analyser obviates the need to pulse the primary ion beam and does not require the use of monoisotopic gallium to preserve mass resolution. The high-duty cycle and reasonable collection efficiency of the new instrument combined with the high spatial resolution of a gallium liquid metal ion source allow chemical observation of features smaller than 50 nm. We have also demonstrated the integration of a scanning probe microscope (SPM) operated as an atomic force microscope (AFM) within the FIB/SEM-SIMS chamber. This provides roughness information, and will also allow true three dimensional chemical images to be reconstructed from SIMS measurements.


  • The role of oxygen in analytical glow discharges: GD-OES and GD-ToF-MS studies

    by Sohail Mushtaq, Juliet C. Pickering, Edward B. M. Steers, Peter Horvath, James A. Whitby, Johann Michler

    The influence of up to 0.8% volume fraction of oxygen on the argon plasma in a direct current analytical glow discharge was studied for iron, titanium, copper and gold samples using both time-of-flight mass spectrometry and high resolution optical UV-Vis Fourier transform spectrometry. A sudden decrease in sputtering rates, optical emission intensities and ion signals is observed at a current and material dependent threshold fraction of oxygen, and is attributed in part to the formation of an oxide layer on the surface. Beyond the threshold oxygen fraction, a further large continuing decrease in ion signals is observed as the oxygen fraction is increased. This smooth decrease of the observed ion signals is attributed to quenching of ions and argon metastable atoms by oxygen in the flowing afterglow in the flow tube used to promote ion transport to the mass spectrometer sampling orifice. At the threshold oxygen fraction, signals from the mass spectrometer decrease by orders of magnitude more than the optical emission observed from analyte and gas ions. This disproportionate decrease is also likely to be due to reactions in the flow tube. The negative mass spectra were also measured for iron, titanium and copper samples and a significant increase in ion signals is observed at material dependent critical oxygen concentration. Results of studies using calamine (a sample with oxide layer) in pure argon are reported and compared with argon/oxygen mixtures.


  • Self-consistent modelling of Mercury’s exosphere by sputtering, micro-meteorite impact and photon-stimulated desorption

    by P. Wurz, J.A. Whitby, U. Rohner, J.A. Martín-Fernández, H. Lammer, C. Kolb


  • Detection of negative ions in glow discharge mass spectrometry for analysis of solid specimens

    by Stela Canulescu, Igor S. Molchan, C. Tauziede, Agnes Tempez, J. A. Whitby, George E. Thompson, Peter Skeldon, P. Chapon, Johann Michler

    A new method is presented for elemental and molecular analysis of halogen-containing samples by glow discharge time-of-flight mass spectrometry, consisting of detection of negative ions from a pulsed RF glow discharge in argon. Analyte signals are mainly extracted from the afterglow regime of the discharge, where the cross section for electron attachment increases. The formation of negative ions from sputtering of metals and metal oxides is compared with that for positive ions. It is shown that the negative ion signals of F− and TaO2F− are enhanced relative to positive ion signals and can be used to study the distribution of a tantalum fluoride layer within the anodized tantala layer. Further, comparison is made with data obtained using glow-discharge optical emission spectroscopy, where elemental fluorine can only be detected using a neon plasma. The ionization mechanisms responsible for the formation of negative ions in glow discharge time-of-flight mass spectrometry are briefly discussed.


  • 18 O/ 16 O isotopic separation in anodic tantala films by glow discharge time‐of‐flight mass spectrometry

    by A. Tempez, S. Canulescu, I. S. Molchan, M. Döbeli, J. A. Whitby, L. Lobo, J. Michler, G. E. Thompson, N. Bordel, P. Chapon, et al.

    Glow discharge mass spectrometry has been widely used for trace and ultra‐trace element analysis of high‐purity alloys. A novel pulsed radio frequency glow discharge time‐of‐flight mass spectrometer (rf GD TOFMS) has been developed that retains the pulsed radio frequency analytical ion source to provide ion signal enhancement due to processes involving Penning ionisation. A time‐resolved detection mode has been implemented to sample the afterglow regime of the pulse profile, corresponding to the highest ion signal intensities. Here, the performance of rf GD TOFMS in isotope differentiation is discussed. Anodic tantala films, comprising 18 O‐rich layers of controlled thicknesses and locations, were formed by appropriate combination of anodising of tantalum in electrolytes enriched with 18 O isotopes and of natural O isotopic abundance. Transmission electron microscopy (TEM) and radio frequency glow discharge optical emission spectrometry (rf GD OES) analyses were performed to examine the morphology and elemental distributions of the specimens, while the content of 18 O in the 18 O‐rich layers was determined by elastic recoil detection analysis(ERDA). In pulsed rf GD TOFMS analysis, characteristic ionic species formed in the glow discharge allows differentiation of 18 O‐rich layers. Particularly, the location of 18 O‐rich layers was determined from the 16 O 18 O and Ta 18 O ion signals at masses m / z 34 and 199, respectively. The locations of 18 O‐rich layers in anodic films, controlled by the selected anodising conditions, were probed precisely. The 18 O profiles in anodic tantala were directly compared with those obtained by dual beam time‐of‐flight SIMS. Copyright © 2009 John Wiley & Sons, Ltd.


  • Open Access

    Collisional modification of the acapulcoite/lodranite parent body revealed by the iodine‐xenon system in lodranites

    by S. A. Crowther, J. A. Whitby, A. Busfield, G. Holland, H. Busemann, J. D. Gilmour

    Abstract—The I‐Xe system of three lodranites has been investigated. Samples of Gibson yielded no isochrons, and late model ages are attributed to late addition of iodine. Two metal and one silicate separate from the transitional lodranite Graves Nunataks (GRA) 95209 gave ages that are consistent with each other and with the literature I‐Xe age of Acapulco feldspar. These yield a mean closure age 4.19 ± 0.53 Ma after the Shallowater enstatite reference age (4562.3 ± 0.4 Ma). Such identical I‐Xe ages from distinct phases imply that the parent material underwent a period of rapid cooling, the absolute age of this event being 4558.1 ± 0.7 Ma. Such rapid cooling indicates an increase in the rate at which heat could be conducted away, requiring a significant modification of the parent body. We suggest the parent body was modified by an impact at or close to the time recorded by the I‐Xe system.An age of 10.4 ± 2.3 Ma after Shallowater has been determined for one whole‐rock sample of Lewis Cliff (LEW) 88280. Since the release pattern is similar to that of GRA 95209 this hints that the larger grain size of this sample may reflect slower cooling due to deeper post impact burial.