Anatolii Semenov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Anatolii Semenov has a total of 105 co-authors. Here are the top co-authors by number of shared publications:
- Tamara V. Sakhno
Полтавський університет економіки і торгівл
11 shared publications Bauyrzhan Yeleussinov
Branch of JSC "NCPD Orleu" Institute of Professional Development in Kyzylorda Region, 2, Aiteke Bi St., 431010000 Kyzylorda, Kazakhstan
4 shared publications- Ruslan Kharak
Poltava State Agrarian University
4 shared publications - Tamara Sakhno
Poltava State Agrarian University, 1/3, Skovorodu Str., 36003, Poltava
4 shared publications Т. В. Сахно
4 shared publications- Irina Korotkova
Poltava State Agrarian University
3 shared publications
Latest Publications
- Open Access
- 1 July 2026
- Published by WNGB Scientific Publishing House Sp. z o.o. in Journal of Ecological Engineering
- Vol. 27 (7) , 99-108
Nitrogen inhibitors as a tool for improving soil nitrogen retention and maize yield under unstable moisture
- 1 July 2026
- Published by WNGB Scientific Publishing House Sp. z o.o. in Journal of Ecological Engineering
- Vol. 27 (7) , 99-108
Open AccessNitrogen inhibitors as a tool for improving soil nitrogen retention and maize yield under unstable moisture
- 2 June 2026
- Published by Wiley in Journal of Food Process Engineering
- Vol. 49 (6)
Three‐Stage Kinetics of Conductive Drying of Meat Raw Materials Under Mechanical Compression With Pressure Release
Conductive drying is an effective method for intensifying heat and mass transfer in food processing due to direct heat supply through the contact surface. However, moisture transfer mechanisms in capillary–porous materials under mechanical compression remain insufficiently understood. The aim of this study was to investigate the kinetics of conductive drying of meat raw materials under controlled mechanical compression and to evaluate the effect of instantaneous pressure release on moisture removal intensity. Experiments were carried out using a laboratory contact‐type unit with double‐sided heat supply at a temperature of 130°C. Excess compression pressure ranged from 35,000 to 105,000 Pa, and the material layer thickness varied from 0.003 to 0.007 m. It was established that increasing compression pressure reduces drying time by 22%–39%. Instantaneous pressure release at the critical moisture content leads to the formation of three‐stage drying kinetics, including drying under compression, a short pulse stage of intensive moisture removal, and a final diffusion‐controlled stage. A mathematical model describing the three‐stage kinetics under variable mechanical compression was developed and experimentally validated, demonstrating high agreement with experimental data.
- 2 June 2026
- Published by Wiley in Journal of Food Process Engineering
- Vol. 49 (6)
Three‐Stage Kinetics of Conductive Drying of Meat Raw Materials Under Mechanical Compression With Pressure Release
Conductive drying is an effective method for intensifying heat and mass transfer in food processing due to direct heat supply through the contact surface. However, moisture transfer mechanisms in capillary–porous materials under mechanical compression remain insufficiently understood. The aim of this study was to investigate the kinetics of conductive drying of meat raw materials under controlled mechanical compression and to evaluate the effect of instantaneous pressure release on moisture removal intensity. Experiments were carried out using a laboratory contact‐type unit with double‐sided heat supply at a temperature of 130°C. Excess compression pressure ranged from 35,000 to 105,000 Pa, and the material layer thickness varied from 0.003 to 0.007 m. It was established that increasing compression pressure reduces drying time by 22%–39%. Instantaneous pressure release at the critical moisture content leads to the formation of three‐stage drying kinetics, including drying under compression, a short pulse stage of intensive moisture removal, and a final diffusion‐controlled stage. A mathematical model describing the three‐stage kinetics under variable mechanical compression was developed and experimentally validated, demonstrating high agreement with experimental data.
- Open Access
- 29 May 2026
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University "KhPI". Series: Energy: Reliability and Energy Efficiency
- No. 1(12),p. 118-124
Current state of integration of vacuum circuit breakers and control systems in medium- and high-voltage electrical networks
The article has a review and analytical character and is devoted to the systematization of modern approaches to the integration of vacuum circuit breakers with control, monitoring, and diagnostic systems in medium- and high-voltage electrical networks. The main attention is paid to 6–35 kV networks, where vacuum circuit breakers have gained the widest practical application, as well as to the prospects for their use in 110–220 kV high-voltage installations as part of Smart Grid digital substations. An analytical and comparative review of switching devices (oil, air, SF₆, and vacuum types) is presented, with a generalized analysis of the electrophysical mechanisms of arc extinction in vacuum, the influence of contact materials (CuCr, AgWC), and the degree of vacuum on the dielectric recovery of the contact gap. The architectures of monitoring and diagnostic systems compatible with IEC 61850 are evaluated, including sensors for electrical and thermal parameters, microprocessor controllers, and Supervisory Control and Data Acquisition or Automated Control System for Technological Processes integration. The results demonstrate that vacuum circuit breakers ensure fast arc extinction and rapid dielectric recovery, have a long switching life, and require no periodic maintenance. Integration with digital monitoring systems significantly reduces fault detection time and the number of emergency shutdowns, while increasing equipment availability. A structural scheme of an integrated “vacuum circuit breaker – control system” complex is proposed, along with practical recommendations for its implementation in industrial and agro-industrial networks of 6–35 kV and potentially up to 110–220 kV. The findings confirm the feasibility of transitioning to digital substations based on IEC 61850 standards. The practical implementation of the proposed technical solutions in industrial and agro-industrial electrical networks will ensure improved power supply reliability, enhanced energy efficiency, reduced operating costs, and compliance with the requirements of modern energy standards.
- 29 May 2026
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University "KhPI". Series: Energy: Reliability and Energy Efficiency
- No. 1(12),p. 118-124
Open AccessCurrent state of integration of vacuum circuit breakers and control systems in medium- and high-voltage electrical networks
The article has a review and analytical character and is devoted to the systematization of modern approaches to the integration of vacuum circuit breakers with control, monitoring, and diagnostic systems in medium- and high-voltage electrical networks. The main attention is paid to 6–35 kV networks, where vacuum circuit breakers have gained the widest practical application, as well as to the prospects for their use in 110–220 kV high-voltage installations as part of Smart Grid digital substations. An analytical and comparative review of switching devices (oil, air, SF₆, and vacuum types) is presented, with a generalized analysis of the electrophysical mechanisms of arc extinction in vacuum, the influence of contact materials (CuCr, AgWC), and the degree of vacuum on the dielectric recovery of the contact gap. The architectures of monitoring and diagnostic systems compatible with IEC 61850 are evaluated, including sensors for electrical and thermal parameters, microprocessor controllers, and Supervisory Control and Data Acquisition or Automated Control System for Technological Processes integration. The results demonstrate that vacuum circuit breakers ensure fast arc extinction and rapid dielectric recovery, have a long switching life, and require no periodic maintenance. Integration with digital monitoring systems significantly reduces fault detection time and the number of emergency shutdowns, while increasing equipment availability. A structural scheme of an integrated “vacuum circuit breaker – control system” complex is proposed, along with practical recommendations for its implementation in industrial and agro-industrial networks of 6–35 kV and potentially up to 110–220 kV. The findings confirm the feasibility of transitioning to digital substations based on IEC 61850 standards. The practical implementation of the proposed technical solutions in industrial and agro-industrial electrical networks will ensure improved power supply reliability, enhanced energy efficiency, reduced operating costs, and compliance with the requirements of modern energy standards.
- 27 May 2026
- Published by IK Press in Journal of Advances in Food Science & Technology
- Vol. 13 (3) , 213-225
Development and Engineering Substantiation of a Low-voltage UV-C System for Bactericidal Sanitation of Milk-transport Containers
Background: Hygienic preparation of milk-transport containers is important for limiting secondary contamination after washing and before filling. Aims: This study aims to develop and substantiate a compact low-voltage ultraviolet-C (UV-C) electrotechnical system for finishing bactericidal sanitation of milk-transport containers and to define its constructive, electrical, operating and safety parameters. Study Design: Engineering development, analytical calculation and safety-oriented substantiation of a prototype sanitation device. Place and Duration of Study: The study was conducted at Poltava State Agrarian University, Poltava, Ukraine, and Poltava Academy of Sciences of Technological Cybernetics of Ukraine, Poltava, Ukraine, during the development, engineering substantiation and manuscript preparation of the prototype in 2024-2026. Methodology: A portable low-voltage UV-C unit was developed for treatment of the internal air volume and accessible inner surfaces of previously washed and drained containers used for milk and dairy-product transportation. The study combined engineering design analysis, electrical calculation, UV-C dose modelling, estimation of energy consumption and safety assessment. The UV-C dose was formalised as the product of average irradiance and exposure time. Microbiological validation and irradiance mapping were not performed at this stage; these procedures are proposed as mandatory steps before industrial implementation. Results: The developed unit is intended for a treated volume of up to 5 m3 and has overall dimensions of 550 x 160 x 160 mm, a mass of 3 kg and an installed electrical power of 20 W. The device can be supplied from 12 or 24 V DC sources, with estimated current consumption of approximately 1.67 A and 0.83 A, respectively. For a maximum treated volume of 5 m3, the specific installed power is 4 W/m3. The calculated energy consumption of one sanitation cycle is 1.67 Wh for 5 min, 3.33 Wh for 10 min, 5.00 Wh for 15 min and 6.67 Wh for 20 min. Conclusion: The proposed system can be considered as a finishing reagent-free sanitation step after mechanical washing, detergent cleaning, rinsing and draining. It is not a substitute for standard cleaning procedures. Since no experimental microbial-reduction data are presented in this manuscript, its expected function is limited to an engineering hypothesis that must be confirmed by UV-C irradiance measurements and microbiological surface swab testing at selected exposure times.
- 27 May 2026
- Published by IK Press in Journal of Advances in Food Science & Technology
- Vol. 13 (3) , 213-225
Development and Engineering Substantiation of a Low-voltage UV-C System for Bactericidal Sanitation of Milk-transport Containers
Background: Hygienic preparation of milk-transport containers is important for limiting secondary contamination after washing and before filling. Aims: This study aims to develop and substantiate a compact low-voltage ultraviolet-C (UV-C) electrotechnical system for finishing bactericidal sanitation of milk-transport containers and to define its constructive, electrical, operating and safety parameters. Study Design: Engineering development, analytical calculation and safety-oriented substantiation of a prototype sanitation device. Place and Duration of Study: The study was conducted at Poltava State Agrarian University, Poltava, Ukraine, and Poltava Academy of Sciences of Technological Cybernetics of Ukraine, Poltava, Ukraine, during the development, engineering substantiation and manuscript preparation of the prototype in 2024-2026. Methodology: A portable low-voltage UV-C unit was developed for treatment of the internal air volume and accessible inner surfaces of previously washed and drained containers used for milk and dairy-product transportation. The study combined engineering design analysis, electrical calculation, UV-C dose modelling, estimation of energy consumption and safety assessment. The UV-C dose was formalised as the product of average irradiance and exposure time. Microbiological validation and irradiance mapping were not performed at this stage; these procedures are proposed as mandatory steps before industrial implementation. Results: The developed unit is intended for a treated volume of up to 5 m3 and has overall dimensions of 550 x 160 x 160 mm, a mass of 3 kg and an installed electrical power of 20 W. The device can be supplied from 12 or 24 V DC sources, with estimated current consumption of approximately 1.67 A and 0.83 A, respectively. For a maximum treated volume of 5 m3, the specific installed power is 4 W/m3. The calculated energy consumption of one sanitation cycle is 1.67 Wh for 5 min, 3.33 Wh for 10 min, 5.00 Wh for 15 min and 6.67 Wh for 20 min. Conclusion: The proposed system can be considered as a finishing reagent-free sanitation step after mechanical washing, detergent cleaning, rinsing and draining. It is not a substitute for standard cleaning procedures. Since no experimental microbial-reduction data are presented in this manuscript, its expected function is limited to an engineering hypothesis that must be confirmed by UV-C irradiance measurements and microbiological surface swab testing at selected exposure times.
- Open Access
- 1 May 2026
- Published by WNGB Scientific Publishing House Sp. z o.o. in Journal of Ecological Engineering
- Vol. 27 (5) , 233-246
Features of quality management of industrial hemp products (Cannabis sativa L.)
A brief review of current research on oil and protein content in industrial hemp seeds is presented. One of the main factors limiting the development of hemp production is identified as the long-term ban on cultivation, which slowed the improvement of agronomic technologies. The study aimed to...
- 1 May 2026
- Published by WNGB Scientific Publishing House Sp. z o.o. in Journal of Ecological Engineering
- Vol. 27 (5) , 233-246
Open AccessFeatures of quality management of industrial hemp products (Cannabis sativa L.)
A brief review of current research on oil and protein content in industrial hemp seeds is presented. One of the main factors limiting the development of hemp production is identified as the long-term ban on cultivation, which slowed the improvement of agronomic technologies. The study aimed to...
- Open Access
- 26 March 2026
- Published by SHEI Pryazovskyi State Technical University
- Vol. 2 (53) , 19-26
Energy-efficient control of the axial electric drive of a pneumatic separator for seed calibration
The paper addresses the issue of improving the energy efficiency and stability of the technological process of seed calibration by upgrading the electric drive of the axial fan in a pneumatic separator. The relevance of the study is determined by the growing requirements for seed quality and the need to reduce specific energy consumption in post-harvest processing of grain crops. The aim of the research is to provide scientific substantiation and experimental evaluation of energy-efficient operating modes of an asynchronous electric drive when applying frequency control. The object of the study is the electric drive of the axial fan of a pneumatic separator equipped with a three-phase induction motor rated at 1.5 kW and controlled by a frequency converter according to the U/f = const law. The experiments were carried out within the frequency range of 30–50 Hz with measurements of active power, current, power factor, air velocity, and specific energy consumption. It was established that the load has a fan-type character with a quadratic dependence of torque and a cubic dependence of power on rotational speed. It is shown that frequency control ensures a reduction in active power and specific energy consumption by 15–35% compared with direct-on-line starting and throttling modes, and also increases the stability of air velocity to ±5–8%. The most rational operating modes are within the frequency range of 35–45 Hz, providing an optimal combination of energy efficiency and pneumatic separation quality. The obtained results can be used for the development of automated control systems for seed-cleaning machines and for improving the efficiency of electromechanical systems in the agro-industrial complex
- 26 March 2026
- Published by SHEI Pryazovskyi State Technical University
- Vol. 2 (53) , 19-26
Open AccessEnergy-efficient control of the axial electric drive of a pneumatic separator for seed calibration
The paper addresses the issue of improving the energy efficiency and stability of the technological process of seed calibration by upgrading the electric drive of the axial fan in a pneumatic separator. The relevance of the study is determined by the growing requirements for seed quality and the need to reduce specific energy consumption in post-harvest processing of grain crops. The aim of the research is to provide scientific substantiation and experimental evaluation of energy-efficient operating modes of an asynchronous electric drive when applying frequency control. The object of the study is the electric drive of the axial fan of a pneumatic separator equipped with a three-phase induction motor rated at 1.5 kW and controlled by a frequency converter according to the U/f = const law. The experiments were carried out within the frequency range of 30–50 Hz with measurements of active power, current, power factor, air velocity, and specific energy consumption. It was established that the load has a fan-type character with a quadratic dependence of torque and a cubic dependence of power on rotational speed. It is shown that frequency control ensures a reduction in active power and specific energy consumption by 15–35% compared with direct-on-line starting and throttling modes, and also increases the stability of air velocity to ±5–8%. The most rational operating modes are within the frequency range of 35–45 Hz, providing an optimal combination of energy efficiency and pneumatic separation quality. The obtained results can be used for the development of automated control systems for seed-cleaning machines and for improving the efficiency of electromechanical systems in the agro-industrial complex
- Open Access
- 22 March 2026
- Published by Oles Honchar Dnipropetrovsk National University in Journal of Chemistry and Technologies
- Vol. 34 (1) , 259-265
COMPREHENSIVE EVALUATION OF ULTRAVIOLET DISINFECTION SYSTEMS CONSIDERING MAINTENANCE, SPECTRAL, AND OPERATIONAL COEFFICIENTS
The paper presents a comprehensive evaluation of ultraviolet (UV) disinfection systems by integrating maintenance, spectral, and operational coefficients into a unified analytical model. The study addresses the progressive decline in UV radiation efficiency caused by lamp aging, surface contamination, and changes in the reflective properties of operating environments. The proposed methodology extends the classical Maintenance Factor (MF) model defined in CIE standards by incorporating additional coefficients that account for spectral effectiveness (SEF), temperature influence (TCF), ballast performance (BF), irradiation geometry (UF), and dose compliance (DCF). Experimental data obtained for various UV systems (TUV15WG13, HNS15G13, TUV36WG13, ZW20D15Y, ZW20D15W) demonstrated that overall system efficiency decreases to 27–36 % of the initial level after 6,000 operating hours. The dominant loss factors were identified as UF (17–38 %), RFMF (20–35 %), and LMF (18–28 %), while RSMF, TCF, and BF contributed minor yet consistent effects. The developed integrated approach provides a more accurate prediction of degradation processes, allowing preventive maintenance scheduling, optimization of energy consumption, and stable disinfection efficiency throughout the service life of UV systems.
- 22 March 2026
- Published by Oles Honchar Dnipropetrovsk National University in Journal of Chemistry and Technologies
- Vol. 34 (1) , 259-265
Open AccessCOMPREHENSIVE EVALUATION OF ULTRAVIOLET DISINFECTION SYSTEMS CONSIDERING MAINTENANCE, SPECTRAL, AND OPERATIONAL COEFFICIENTS
The paper presents a comprehensive evaluation of ultraviolet (UV) disinfection systems by integrating maintenance, spectral, and operational coefficients into a unified analytical model. The study addresses the progressive decline in UV radiation efficiency caused by lamp aging, surface contamination, and changes in the reflective properties of operating environments. The proposed methodology extends the classical Maintenance Factor (MF) model defined in CIE standards by incorporating additional coefficients that account for spectral effectiveness (SEF), temperature influence (TCF), ballast performance (BF), irradiation geometry (UF), and dose compliance (DCF). Experimental data obtained for various UV systems (TUV15WG13, HNS15G13, TUV36WG13, ZW20D15Y, ZW20D15W) demonstrated that overall system efficiency decreases to 27–36 % of the initial level after 6,000 operating hours. The dominant loss factors were identified as UF (17–38 %), RFMF (20–35 %), and LMF (18–28 %), while RSMF, TCF, and BF contributed minor yet consistent effects. The developed integrated approach provides a more accurate prediction of degradation processes, allowing preventive maintenance scheduling, optimization of energy consumption, and stable disinfection efficiency throughout the service life of UV systems.
- Open Access
- 31 December 2025
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University «KhPI» Series: New solutions in modern technologies
- No. 4(26),p. 72-77
ANALYSIS OF DESIGN METHODS AND LIGHTNING PROTECTION FOR OVERHEAD LINES WITH INSULATED CONDUCTORS
The purpose of this research is to analyze and improve the technical approaches to designing overhead power lines with self-supporting insulated conductors during the transition from bare conductors in low- and medium-voltage networks. The applied methods include analytical evaluation of mechanical and climatic loads using the limit state design approach, comparative assessment of conductor sizing methods based on economic current density and economic current intervals, and modeling of lightning impact using simplified expressions for critical lightning current and insulator flashover probability. The results show that enhancing the reliability and electrical safety of overhead lines requires detailed consideration of the predominance of horizontal loads over vertical ones, the influence of wind pressure, conductor and ground wire weight, insulators and mounting equipment on the dimensions of supports and foundations. The study examines the selection of conductor cross-sections in overhead and cable lines, verifying thermal limits and voltage drop for various voltage levels and network configurations. Particular attention is paid to sizing phase conductors of self-supporting insulated cables considering allowable operating temperatures of thermoplastic and cross-linked polyethylene insulation, the annual duration of maximum load, mechanical strength, and voltage drop constraints. The main lightning impact scenarios are analyzed, including shielding failure, direct lightning strokes to the tower with back-flashover, and lightning strokes to the shield wire in mid-span causing flashover of the shield-to-phase air gap. The research confirms the importance of tower height, grounding resistance, and the inductances of the tower and shield wire for evaluating lightning performance. Structural and technological aspects of erecting insulated overhead lines are presented, including standardization of concrete and steel poles, methods of pole footing in various soils, installation of hooks and cross-arms, conductor stringing using running blocks, pilot ropes and pulling grips, and compression joints for phase conductors. The role of nonlinear metal-oxide surge arresters as a primary means of protecting equipment and insulation in the voltage range from 0.38 to 110 kV is substantiated; the requirements for environmental resistance, pollution performance, mechanical strength, and design of polymeric and porcelain-housed arresters are summarized. The conclusions emphasize that the coordinated use of structural design methods, conductor sizing techniques, lightning protection systems and modern erection technologies significantly increases the reliability, operational safety and energy efficiency of overhead lines employing self-supporting insulated conductors.
- 31 December 2025
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University «KhPI» Series: New solutions in modern technologies
- No. 4(26),p. 72-77
Open AccessANALYSIS OF DESIGN METHODS AND LIGHTNING PROTECTION FOR OVERHEAD LINES WITH INSULATED CONDUCTORS
The purpose of this research is to analyze and improve the technical approaches to designing overhead power lines with self-supporting insulated conductors during the transition from bare conductors in low- and medium-voltage networks. The applied methods include analytical evaluation of mechanical and climatic loads using the limit state design approach, comparative assessment of conductor sizing methods based on economic current density and economic current intervals, and modeling of lightning impact using simplified expressions for critical lightning current and insulator flashover probability. The results show that enhancing the reliability and electrical safety of overhead lines requires detailed consideration of the predominance of horizontal loads over vertical ones, the influence of wind pressure, conductor and ground wire weight, insulators and mounting equipment on the dimensions of supports and foundations. The study examines the selection of conductor cross-sections in overhead and cable lines, verifying thermal limits and voltage drop for various voltage levels and network configurations. Particular attention is paid to sizing phase conductors of self-supporting insulated cables considering allowable operating temperatures of thermoplastic and cross-linked polyethylene insulation, the annual duration of maximum load, mechanical strength, and voltage drop constraints. The main lightning impact scenarios are analyzed, including shielding failure, direct lightning strokes to the tower with back-flashover, and lightning strokes to the shield wire in mid-span causing flashover of the shield-to-phase air gap. The research confirms the importance of tower height, grounding resistance, and the inductances of the tower and shield wire for evaluating lightning performance. Structural and technological aspects of erecting insulated overhead lines are presented, including standardization of concrete and steel poles, methods of pole footing in various soils, installation of hooks and cross-arms, conductor stringing using running blocks, pilot ropes and pulling grips, and compression joints for phase conductors. The role of nonlinear metal-oxide surge arresters as a primary means of protecting equipment and insulation in the voltage range from 0.38 to 110 kV is substantiated; the requirements for environmental resistance, pollution performance, mechanical strength, and design of polymeric and porcelain-housed arresters are summarized. The conclusions emphasize that the coordinated use of structural design methods, conductor sizing techniques, lightning protection systems and modern erection technologies significantly increases the reliability, operational safety and energy efficiency of overhead lines employing self-supporting insulated conductors.
- Open Access
- 30 December 2025
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University "KhPI". Series: Energy: Reliability and Energy Efficiency
- No. 2(11),p. 91-95
Optimization of pump unit electric drives in water supply systems based on frequency control
The article examines the issue of improving the energy efficiency of pumping stations through the modernization of their electric drives by implementing frequency and combined control methods. The relevance of the problem is determined by the rising cost of energy resources, the increasing requirements for the efficiency of technological processes, and the significant share of electricity consumed by pumping equipment in industry and public utilities. The feasibility of transitioning from non-adjustable asynchronous electric motors to frequency-controlled systems is substantiated, enabling pumps to adapt to changes in water consumption, reduce energy consumption, improve network pressure stability, extend equipment service life, and lower maintenance and repair costs. The paper presents the results of mathematical modeling of pumping station operating modes based on similarity laws and an analysis of daily operating graphs for various control modes. It confirms a reduction in specific energy consumption with frequency control to 0.32 kWh/m³, as well as the effectiveness of a combined control scheme using three pump units, one of which operates with a frequency converter. This approach achieved a minimum specific energy consumption of 0.06 kWh/m³, corresponding to up to 60 % energy savings compared to traditional non-regulated schemes. The study confirmed that the implementation of frequency and combined control makes it possible to significantly increase the energy efficiency of pumping units under variable load conditions, reduce hydraulic shocks, lower starting currents, and improve equipment reliability. The developed recommendations can be applied in the modernization of existing pumping stations, the planning of investment projects in the water supply sector, and the implementation of automated control systems for industrial and municipal facilities.
- 30 December 2025
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University "KhPI". Series: Energy: Reliability and Energy Efficiency
- No. 2(11),p. 91-95
Open AccessOptimization of pump unit electric drives in water supply systems based on frequency control
The article examines the issue of improving the energy efficiency of pumping stations through the modernization of their electric drives by implementing frequency and combined control methods. The relevance of the problem is determined by the rising cost of energy resources, the increasing requirements for the efficiency of technological processes, and the significant share of electricity consumed by pumping equipment in industry and public utilities. The feasibility of transitioning from non-adjustable asynchronous electric motors to frequency-controlled systems is substantiated, enabling pumps to adapt to changes in water consumption, reduce energy consumption, improve network pressure stability, extend equipment service life, and lower maintenance and repair costs. The paper presents the results of mathematical modeling of pumping station operating modes based on similarity laws and an analysis of daily operating graphs for various control modes. It confirms a reduction in specific energy consumption with frequency control to 0.32 kWh/m³, as well as the effectiveness of a combined control scheme using three pump units, one of which operates with a frequency converter. This approach achieved a minimum specific energy consumption of 0.06 kWh/m³, corresponding to up to 60 % energy savings compared to traditional non-regulated schemes. The study confirmed that the implementation of frequency and combined control makes it possible to significantly increase the energy efficiency of pumping units under variable load conditions, reduce hydraulic shocks, lower starting currents, and improve equipment reliability. The developed recommendations can be applied in the modernization of existing pumping stations, the planning of investment projects in the water supply sector, and the implementation of automated control systems for industrial and municipal facilities.
- Open Access
- 29 December 2025
- Published by SHEI Pryazovskyi State Technical University in Reporter of the Priazovskyi State Technical University. Section: Technical sciences
- No. 52,p. 132-139
Development of an electrotechnical system for UV water disinfection in recirculating aquaculture systems
One of the key tasks in the operation of recirculating aquaculture systems (RAS) for fish farming is to ensure the microbiological safety of water. Among the known disinfection methods, the most widely used are ozonation, ultraviolet (UV) irradiation, and their combinations. However, the application of ozone is accompanied by several limitations: toxicity to aquatic organisms, formation of harmful by-products, and reduction of dissolved oxygen in water, which makes it less suitable for RAS. This study presents the results of research on the development and implementation of an electrotechnical UV water disinfection system operating on the principle of flow-through irradiation with preliminary filtration. As a source of bactericidal radiation, low-pressure lamps with a maximum emission wavelength of 254 nm were used. Experimental studies conducted at a sturgeon aquafarm demonstrated that the use of a UV unit with a total power of 850 W (10 low-pressure lamps) provides a stable bactericidal flux of 220 W/m² and ensures effective inactivation of microorganisms in systems with a water volume of 100 m³. Throughout the observation period, the total microbial count, total coliforms, and E. coli did not exceed permissible limits, and no cases of bacterial or fungal diseases in fish were recorded. The developed electrotechnical water disinfection system improves the reliability and biological safety of RAS operation without the use of ozone, is energy-efficient, and can be scaled for industrial aquaculture facilities
- 29 December 2025
- Published by SHEI Pryazovskyi State Technical University in Reporter of the Priazovskyi State Technical University. Section: Technical sciences
- No. 52,p. 132-139
Open AccessDevelopment of an electrotechnical system for UV water disinfection in recirculating aquaculture systems
One of the key tasks in the operation of recirculating aquaculture systems (RAS) for fish farming is to ensure the microbiological safety of water. Among the known disinfection methods, the most widely used are ozonation, ultraviolet (UV) irradiation, and their combinations. However, the application of ozone is accompanied by several limitations: toxicity to aquatic organisms, formation of harmful by-products, and reduction of dissolved oxygen in water, which makes it less suitable for RAS. This study presents the results of research on the development and implementation of an electrotechnical UV water disinfection system operating on the principle of flow-through irradiation with preliminary filtration. As a source of bactericidal radiation, low-pressure lamps with a maximum emission wavelength of 254 nm were used. Experimental studies conducted at a sturgeon aquafarm demonstrated that the use of a UV unit with a total power of 850 W (10 low-pressure lamps) provides a stable bactericidal flux of 220 W/m² and ensures effective inactivation of microorganisms in systems with a water volume of 100 m³. Throughout the observation period, the total microbial count, total coliforms, and E. coli did not exceed permissible limits, and no cases of bacterial or fungal diseases in fish were recorded. The developed electrotechnical water disinfection system improves the reliability and biological safety of RAS operation without the use of ozone, is energy-efficient, and can be scaled for industrial aquaculture facilities