Andre Omer Desjarlais
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Andre Omer Desjarlais has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Mikael Salonvaara
Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)
8 shared publications Oak Ridge Oak Ridge National Laboratory (Ornl)
6 shared publicationsEmishaw Iffa
Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)
5 shared publications- Som Shrestha
Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States). Building Technologies Research and Integration Center (BTRIC)
5 shared publications Islam Safir
Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)
3 shared publications- Niraj Kunwar
Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)
3 shared publications
Latest Publications
- 1 October 2026
- Published by Office of Scientific and Technical Information (OSTI)
Quantitative Assessment Methodology for Water Intrusion Detection in Wall Systems: Phase 3
Water intrusion in building enclosure systems can lead to material deterioration, mold growth, corrosion, reduced service life, and costly repairs. Current water-penetration test methods, including ASTM E331, are primarily based on visual observation of water leakage and do not provide a standardized method for quantifying moisture that enters or accumulates within wall assemblies. This Phase 3 study builds on previous research conducted by Oak Ridge National Laboratory (ORNL), the Air Barrier Association of America (ABAA), Tremco, Inc., and other industry partners to further evaluate practical methods for detecting and quantifying moisture intrusion in wall systems. The objective of this phase was to evaluate the performance of handheld moisture meters, capacitance-type relative humidity (RH) sensors, and resistance-type moisture pin probes during controlled water-spray testing of wall assemblies. Two 8 ft × 8 ft steel-stud wall specimens with exterior gypsum sheathing and self-adhered water-resistive barriers (WRBs) were constructed with intentional holes to create known water entry paths. A third wall assembly with no penetration was used as a control specimen to evaluate the effect of changing laboratory conditions on sensor readings. Each test specimen was exposed to water spray in accordance with ASTM E331. The test sequence included 60 minutes of water spray without an applied pressure differential, followed by 120 minutes of water spray under a −300 Pa pressure differential. Sensors were installed beneath the WRB, on the interior surface of the gypsum sheathing, and at mid-depth within the gypsum sheathing. The test walls were continuously monitored during spraying and subsequent overnight drying. Handheld moisture-meter readings were also collected from the interior side of the wall after the initial spray period and after completion of the pressure-spray exposure. The results showed that all evaluated methods were capable of detecting moisture increases associated with water exposure. The handheld Delmhorst BD-2100 and Protimeter MMS2 moisture meters generally produced consistent trends and identified increased moisture levels after the full water-spray and pressure exposure. The two meters showed strong overall agreement. Both instruments also indicated that the wall assemblies returned to generally dry conditions after overnight drying. The embedded capacitance RH sensors provided continuous measurements of moisture conditions at the gypsum sheathing surfaces. Sensors located beneath the WRB showed rapid RH increases during water spraying, demonstrating their ability to detect moisture accumulation that may not be visible from the interior side of the wall. Sensors located on the back side of the gypsum sheathing showed the strongest responses near fully penetrating 1/8-inch holes, where water was able to pass through the WRB and gypsum sheathing under depressurization. Sensors near partially drilled 1/4-inch holes generally showed lower responses because these openings did not create direct through thickness pathways for water. The resistance type moisture pin probes produced results mostly consistent with those of the capacitance RH sensors. Pins installed near the exterior surface of the gypsum sheathing beneath the WRB showed the largest moisture increases, particularly at locations near fully penetrating holes. Mid-depth pins showed lower responses, indicating that moisture accumulation was concentrated near the exterior surface of the gypsum sheathing during the test period. The moisture pin calibration was effective over the tested RH range. The control wall remained comparatively stable throughout testing, although some sensor readings changed in response to laboratory humidity conditions. This finding emphasizes the importance of monitoring ambient temperature and RH, or using a control specimen, when interpreting embedded-sensor data. Overall, the Phase 3 results confirm that no single measurement method fully characterizes water intrusion within a wall assembly. Handheld moisture meters provide a practical approach for post-test spot measurements, while embedded capacitance RH sensors and moisture pins provide continuous information on the timing, location, severity, and drying behavior of moisture intrusion. Using capacitance RH sensors and moisture pin probes together can provide greater confidence in identifying moisture conditions and interpreting water-intrusion test results.
- 1 October 2026
- Published by Office of Scientific and Technical Information (OSTI)
Quantitative Assessment Methodology for Water Intrusion Detection in Wall Systems: Phase 3
Water intrusion in building enclosure systems can lead to material deterioration, mold growth, corrosion, reduced service life, and costly repairs. Current water-penetration test methods, including ASTM E331, are primarily based on visual observation of water leakage and do not provide a standardized method for quantifying moisture that enters or accumulates within wall assemblies. This Phase 3 study builds on previous research conducted by Oak Ridge National Laboratory (ORNL), the Air Barrier Association of America (ABAA), Tremco, Inc., and other industry partners to further evaluate practical methods for detecting and quantifying moisture intrusion in wall systems. The objective of this phase was to evaluate the performance of handheld moisture meters, capacitance-type relative humidity (RH) sensors, and resistance-type moisture pin probes during controlled water-spray testing of wall assemblies. Two 8 ft × 8 ft steel-stud wall specimens with exterior gypsum sheathing and self-adhered water-resistive barriers (WRBs) were constructed with intentional holes to create known water entry paths. A third wall assembly with no penetration was used as a control specimen to evaluate the effect of changing laboratory conditions on sensor readings. Each test specimen was exposed to water spray in accordance with ASTM E331. The test sequence included 60 minutes of water spray without an applied pressure differential, followed by 120 minutes of water spray under a −300 Pa pressure differential. Sensors were installed beneath the WRB, on the interior surface of the gypsum sheathing, and at mid-depth within the gypsum sheathing. The test walls were continuously monitored during spraying and subsequent overnight drying. Handheld moisture-meter readings were also collected from the interior side of the wall after the initial spray period and after completion of the pressure-spray exposure. The results showed that all evaluated methods were capable of detecting moisture increases associated with water exposure. The handheld Delmhorst BD-2100 and Protimeter MMS2 moisture meters generally produced consistent trends and identified increased moisture levels after the full water-spray and pressure exposure. The two meters showed strong overall agreement. Both instruments also indicated that the wall assemblies returned to generally dry conditions after overnight drying. The embedded capacitance RH sensors provided continuous measurements of moisture conditions at the gypsum sheathing surfaces. Sensors located beneath the WRB showed rapid RH increases during water spraying, demonstrating their ability to detect moisture accumulation that may not be visible from the interior side of the wall. Sensors located on the back side of the gypsum sheathing showed the strongest responses near fully penetrating 1/8-inch holes, where water was able to pass through the WRB and gypsum sheathing under depressurization. Sensors near partially drilled 1/4-inch holes generally showed lower responses because these openings did not create direct through thickness pathways for water. The resistance type moisture pin probes produced results mostly consistent with those of the capacitance RH sensors. Pins installed near the exterior surface of the gypsum sheathing beneath the WRB showed the largest moisture increases, particularly at locations near fully penetrating holes. Mid-depth pins showed lower responses, indicating that moisture accumulation was concentrated near the exterior surface of the gypsum sheathing during the test period. The moisture pin calibration was effective over the tested RH range. The control wall remained comparatively stable throughout testing, although some sensor readings changed in response to laboratory humidity conditions. This finding emphasizes the importance of monitoring ambient temperature and RH, or using a control specimen, when interpreting embedded-sensor data. Overall, the Phase 3 results confirm that no single measurement method fully characterizes water intrusion within a wall assembly. Handheld moisture meters provide a practical approach for post-test spot measurements, while embedded capacitance RH sensors and moisture pins provide continuous information on the timing, location, severity, and drying behavior of moisture intrusion. Using capacitance RH sensors and moisture pin probes together can provide greater confidence in identifying moisture conditions and interpreting water-intrusion test results.
- 1 August 2026
- Published by ASTM International
- p. 244-260
Enhancing Thermal Performance in Construction: The Development of Insulated Cross-Laminated Timber Panels
- 1 August 2026
- Published by ASTM International
- p. 244-260
Enhancing Thermal Performance in Construction: The Development of Insulated Cross-Laminated Timber Panels
- Open Access
- 1 July 2026
- Published by Office of Scientific and Technical Information (OSTI)
Measured Baseline of a Double-Wide Manufactured Home Testbed: Hygrothermal and Energy Performance
A 1990 double-wide manufactured home (MH) dimensioned 26 ft × 40 ft with an area of 1,040 ft2 and total volume of 8,320 ft3 was installed and instrumented on Oak Ridge National Laboratory’s (ORNL) main campus in Oak Ridge, Tennessee to establish baseline (“as-is”) performance for envelope, airtightness, and space-conditioning energy use. The unoccupied test facility was instrumented with more than 200 sensors to quantify hygrothermal behavior across the four wall orientations and major assemblies (walls, floor, and ceiling/roof), including temperature (thermistors/thermocouples), relative humidity, and heat-flux measurements. Boundary conditions were recorded using an on-site weather station (air temperature, relative humidity, pressure, precipitation, solar radiation, wind speed and direction). Electrical consumption of space-conditioning equipment was monitored with circuit-level power metering, and additional instrumentation supported condensate measurement and mean radiant temperature characterization. Field-measured, monthly integrated thermal resistance (R-value) was calculated from December 2025 through May 2026 using surface temperatures and in-situ heat-flux data. Wall thermal performance was stable and consistent with calculated values: measured integrated R-values ranged from 18.5 to 19.5 hr·ft²·°F/Btu versus a calculated value of ~19.2. In contrast, the floor assembly underperformed substantially with measured integrated R-values ranging from 10.1 to 12.8 hr·ft²·°F/Btu compared to a calculated value of ~20.4. This reduction is consistent with observed degradation of the belly cavity system (sagging/failed membrane and displaced fiberglass insulation), which likely increased convective bypass and reduced effective insulation performance. Ceiling integrated R-values were most reliable during winter (12.0–12.7 hr·ft²·°F/Btu from December–February), aligning with the calculated ceiling value (10.8 ± 2) given measured variability in loose-fill thickness; spring results became highly variable as temperature differentials weakened due to solar effects. Sheathing temperature and relative humidity (RH monitoring showed broadly similar behavior across all wall orientations, with periods above 80% RH occurring primarily during colder conditions and generally declining as temperatures increased, indicating seasonal drying potential and no clear, persistent mold-risk signature in the monitored wall locations. The floor sheathing exhibited wider RH swings, consistent with the compromised belly condition. Roof OSB sheathing experienced pronounced solar-driven temperature peaks (maximum recorded ~160.5°F in spring), with modest RH differences between slopes, underscoring the importance of summer overheating considerations for any future above-sheathing insulation retrofits. Airtightness testing using multipoint depressurization blower door measurements found the home to be extremely leaky in its baseline condition at 18.1 ACH50. Sealing the vents and central HVAC distribution system reduced leakage to 14.8 ACH50 (an ~18% reduction), demonstrating that duct/distribution pathways contribute materially to whole-house leakage. Two off-the-shelf tape-based “DIY” duct-sealing approaches produced smaller reductions (to 17.3 and 16.8 ACH50), indicating limited whole-house benefit from simple register/duct sealing measures alone. Space heating during winter baseline operation was provided by three variable-speed window space conditioner (WSC) units (two from Manufacturer A and one from Manufacturer B). Based on monitored inlet/outlet air temperatures and power measurements for the most instrumented unit, average WSC winter performance (December 2025 and January 2026) ranged from coefficient of performance (COP) ~2.5 to 3.08, with uncertainty driven primarily by airflow measurement limitations on one unit. Using conservative assumptions for building-level comparison, WSC operation was estimated to reduce heating energy use by roughly 55% and peak demand by roughly 40% relative to distributed electric resistance (ER) heating providing equivalent delivered heat. Planned and unplanned power interruption tests further highlighted peak-demand implications during recovery. After an unplanned ~4-hour outage (average outdoor ~22°F), three WSCs restored indoor conditions to setpoint in under 2 hours with a measured peak of 2,224 W. In a planned 9-hour shutdown at ~20°F using four 1,500 W resistance heaters, recovery required ~3 hours with a 5,424 W peak. A planned 9-hour outage using three WSCs recovered in ~3 hours with a 4,440 W peak. A mixed strategy (two WSCs plus two 1,500 W resistance heaters) recovered in ~2.5 hours at ~30°F with a 4,236 W peak and reduced recovery energy use by 46% relative to resistance-only heating. Collectively, these baseline results quantify key envelope deficiencies (notably the floor), document very high infiltration, and demonstrate the potential of WSC heating and cooling systems to reduce energy use and peak electrical demand in older, leaky MHs.
- 1 July 2026
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessMeasured Baseline of a Double-Wide Manufactured Home Testbed: Hygrothermal and Energy Performance
A 1990 double-wide manufactured home (MH) dimensioned 26 ft × 40 ft with an area of 1,040 ft2 and total volume of 8,320 ft3 was installed and instrumented on Oak Ridge National Laboratory’s (ORNL) main campus in Oak Ridge, Tennessee to establish baseline (“as-is”) performance for envelope, airtightness, and space-conditioning energy use. The unoccupied test facility was instrumented with more than 200 sensors to quantify hygrothermal behavior across the four wall orientations and major assemblies (walls, floor, and ceiling/roof), including temperature (thermistors/thermocouples), relative humidity, and heat-flux measurements. Boundary conditions were recorded using an on-site weather station (air temperature, relative humidity, pressure, precipitation, solar radiation, wind speed and direction). Electrical consumption of space-conditioning equipment was monitored with circuit-level power metering, and additional instrumentation supported condensate measurement and mean radiant temperature characterization. Field-measured, monthly integrated thermal resistance (R-value) was calculated from December 2025 through May 2026 using surface temperatures and in-situ heat-flux data. Wall thermal performance was stable and consistent with calculated values: measured integrated R-values ranged from 18.5 to 19.5 hr·ft²·°F/Btu versus a calculated value of ~19.2. In contrast, the floor assembly underperformed substantially with measured integrated R-values ranging from 10.1 to 12.8 hr·ft²·°F/Btu compared to a calculated value of ~20.4. This reduction is consistent with observed degradation of the belly cavity system (sagging/failed membrane and displaced fiberglass insulation), which likely increased convective bypass and reduced effective insulation performance. Ceiling integrated R-values were most reliable during winter (12.0–12.7 hr·ft²·°F/Btu from December–February), aligning with the calculated ceiling value (10.8 ± 2) given measured variability in loose-fill thickness; spring results became highly variable as temperature differentials weakened due to solar effects. Sheathing temperature and relative humidity (RH monitoring showed broadly similar behavior across all wall orientations, with periods above 80% RH occurring primarily during colder conditions and generally declining as temperatures increased, indicating seasonal drying potential and no clear, persistent mold-risk signature in the monitored wall locations. The floor sheathing exhibited wider RH swings, consistent with the compromised belly condition. Roof OSB sheathing experienced pronounced solar-driven temperature peaks (maximum recorded ~160.5°F in spring), with modest RH differences between slopes, underscoring the importance of summer overheating considerations for any future above-sheathing insulation retrofits. Airtightness testing using multipoint depressurization blower door measurements found the home to be extremely leaky in its baseline condition at 18.1 ACH50. Sealing the vents and central HVAC distribution system reduced leakage to 14.8 ACH50 (an ~18% reduction), demonstrating that duct/distribution pathways contribute materially to whole-house leakage. Two off-the-shelf tape-based “DIY” duct-sealing approaches produced smaller reductions (to 17.3 and 16.8 ACH50), indicating limited whole-house benefit from simple register/duct sealing measures alone. Space heating during winter baseline operation was provided by three variable-speed window space conditioner (WSC) units (two from Manufacturer A and one from Manufacturer B). Based on monitored inlet/outlet air temperatures and power measurements for the most instrumented unit, average WSC winter performance (December 2025 and January 2026) ranged from coefficient of performance (COP) ~2.5 to 3.08, with uncertainty driven primarily by airflow measurement limitations on one unit. Using conservative assumptions for building-level comparison, WSC operation was estimated to reduce heating energy use by roughly 55% and peak demand by roughly 40% relative to distributed electric resistance (ER) heating providing equivalent delivered heat. Planned and unplanned power interruption tests further highlighted peak-demand implications during recovery. After an unplanned ~4-hour outage (average outdoor ~22°F), three WSCs restored indoor conditions to setpoint in under 2 hours with a measured peak of 2,224 W. In a planned 9-hour shutdown at ~20°F using four 1,500 W resistance heaters, recovery required ~3 hours with a 5,424 W peak. A planned 9-hour outage using three WSCs recovered in ~3 hours with a 4,440 W peak. A mixed strategy (two WSCs plus two 1,500 W resistance heaters) recovered in ~2.5 hours at ~30°F with a 4,236 W peak and reduced recovery energy use by 46% relative to resistance-only heating. Collectively, these baseline results quantify key envelope deficiencies (notably the floor), document very high infiltration, and demonstrate the potential of WSC heating and cooling systems to reduce energy use and peak electrical demand in older, leaky MHs.
- 1 May 2026
- Published by Office of Scientific and Technical Information (OSTI)
Durability of ABC Team Wall Assemblies
This study evaluates the long-term hygrothermal durability of four advanced retrofit wall systems using a field test facility located in Hollywood, South Carolina, representative of a mixed-humid coastal climate (Zone 3). The research focuses on assessing the thermal and moisture performance of a baseline wall assembly retrofitted with (1) Tremco/Dryvit prefabricated panel systems (Revitalite and Fedderlite), (2) Reinforced Fiberglass Plastic (RFP) panels developed by Oak Ridge National Laboratory (ORNL), and (3) Vacuum Insulated Panels (VIP) integrated with EPS by Home Innovation Research Labs (HIRL) and ORNL. A baseline wall representing a typical uninsulated wood-frame construction was used for comparison.
- 1 May 2026
- Published by Office of Scientific and Technical Information (OSTI)
Durability of ABC Team Wall Assemblies
This study evaluates the long-term hygrothermal durability of four advanced retrofit wall systems using a field test facility located in Hollywood, South Carolina, representative of a mixed-humid coastal climate (Zone 3). The research focuses on assessing the thermal and moisture performance of a baseline wall assembly retrofitted with (1) Tremco/Dryvit prefabricated panel systems (Revitalite and Fedderlite), (2) Reinforced Fiberglass Plastic (RFP) panels developed by Oak Ridge National Laboratory (ORNL), and (3) Vacuum Insulated Panels (VIP) integrated with EPS by Home Innovation Research Labs (HIRL) and ORNL. A baseline wall representing a typical uninsulated wood-frame construction was used for comparison.
- Open Access
- 1 August 2025
- Published by Office of Scientific and Technical Information (OSTI)
Quantifying and Optimizing the Energy Benefits of Mass Timber Construction
- 1 August 2025
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessQuantifying and Optimizing the Energy Benefits of Mass Timber Construction
- 19 December 2024
- Published by Springer Nature
- p. 460-466
Thermal Performance of Metal Framing with Reflective Insulations
- 19 December 2024
- Published by Springer Nature
- p. 460-466
Thermal Performance of Metal Framing with Reflective Insulations
- Open Access
- 1 December 2024
- Published by Office of Scientific and Technical Information (OSTI)
The Hygrothermal Performance of Continuous and Cavity Wood Fiber Insulation
- 1 December 2024
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessThe Hygrothermal Performance of Continuous and Cavity Wood Fiber Insulation
- 8 August 2024
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 30 (7) , 693
Buildings XV Conference Special Issue
- 8 August 2024
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 30 (7) , 693
Buildings XV Conference Special Issue