Jamshid H. Karimov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jamshid H. Karimov has a total of 110 co-authors. Here are the top co-authors by number of shared publications:
- Kiyotaka Fukamachi
Department of Cardiovascular Surgery, Kyushu University Graduate School of Medicine, Fukuoka, Japan
33 shared publications Barry D. Kuban
Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio
22 shared publicationsKiyotaka Fukamachi
Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio
21 shared publicationsDavid J. Horvath
R1 Engineering Euclid Ohio USA
20 shared publicationsAnthony R. Polakowski
Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio
15 shared publicationsGengo Sunagawa
Department of Biomedical Engineering Cleveland Clinic Lerner Research Institute Cleveland Ohio USA
14 shared publications
Latest Publications
- 15 September 2026
- Published by Wiley in Artificial Organs
Modular Design Approach for Mechanical Circulatory Support Architecture: A Novel Platform for Cross‐Technology Applications
Background: In a critical care setting, a plethora of life‐saving devices, including mechanical circulatory support (MCS) systems, with their powering sources, wiring, and user interfaces, create significant challenges for operational efficiency and patient safety. We report a study of an integrated, user‐friendly, modular life support platform (LSP) designed to be suitable for complex clinical and emergency use scenarios. Methods: Surveys were conducted (21 centers of excellence), involving clinical and nursing staff ( n = 39), focusing on functional requirements, environmental adaptability, alert systems, and user interfaces. In total, 77 user requirements specifications (URS), 272 product requirements specifications (PRS), and 30 KANO model parameters were analyzed by the cross‐functional development team, complemented by industrial design analysis, usability engineering, and iterative validation of device features to produce a coherent modular architecture. We hypothesized that the integrated architecture would support task completion within predefined operational acceptance criteria and minimize potential use errors under simulated‐use conditions. Results: The LSP architecture incorporated three configurations: (1) an extracorporeal ventricular assist device (VAD) and adjustable support arm, (2) an extracorporeal membrane oxygenation (ECMO) system with a modular oxygenator and pump, and (3) an investigational percutaneous ventricular assist devices (pVADs) featuring a flushing pump system, a drive motor, and a catheter pump head. Usability testing confirmed its intended adaptability and effectiveness across ICU, ER, and cardiac intensive care units (CICU), operating rooms (OR), and cardiac catheterization laboratories. Conclusions: Demonstrated task completion within predefined operational acceptance criteria, whereas user failure modes and effects analysis (UFMEA) reassessment reduced the numbers of NAC and ALARP risk items.
- 15 September 2026
- Published by Wiley in Artificial Organs
Modular Design Approach for Mechanical Circulatory Support Architecture: A Novel Platform for Cross‐Technology Applications
Background: In a critical care setting, a plethora of life‐saving devices, including mechanical circulatory support (MCS) systems, with their powering sources, wiring, and user interfaces, create significant challenges for operational efficiency and patient safety. We report a study of an integrated, user‐friendly, modular life support platform (LSP) designed to be suitable for complex clinical and emergency use scenarios. Methods: Surveys were conducted (21 centers of excellence), involving clinical and nursing staff ( n = 39), focusing on functional requirements, environmental adaptability, alert systems, and user interfaces. In total, 77 user requirements specifications (URS), 272 product requirements specifications (PRS), and 30 KANO model parameters were analyzed by the cross‐functional development team, complemented by industrial design analysis, usability engineering, and iterative validation of device features to produce a coherent modular architecture. We hypothesized that the integrated architecture would support task completion within predefined operational acceptance criteria and minimize potential use errors under simulated‐use conditions. Results: The LSP architecture incorporated three configurations: (1) an extracorporeal ventricular assist device (VAD) and adjustable support arm, (2) an extracorporeal membrane oxygenation (ECMO) system with a modular oxygenator and pump, and (3) an investigational percutaneous ventricular assist devices (pVADs) featuring a flushing pump system, a drive motor, and a catheter pump head. Usability testing confirmed its intended adaptability and effectiveness across ICU, ER, and cardiac intensive care units (CICU), operating rooms (OR), and cardiac catheterization laboratories. Conclusions: Demonstrated task completion within predefined operational acceptance criteria, whereas user failure modes and effects analysis (UFMEA) reassessment reduced the numbers of NAC and ALARP risk items.
- 5 August 2026
- Published by Wolters Kluwer Health in ASAIO Journal
Automatic Balance Regulation in a Pediatric Total Artificial Heart
Unbalanced pressures and volumes between the right and left atrium will cause systemic and/or pulmonary congestion. The continuous-flow (CF) total artificial hearts (TAHs) developed at the Cleveland Clinic mitigate pressure imbalance by titrating right pump output via pressure-related changes in rotor axial position. Hall effect sensors were placed and calibrated at both ends of the pediatric CF TAH (P-CFTAH) stator bore to track the rotor’s permanent magnet location. The P-CFTAH was placed on a mock loop in water/glycerin, where several hemodynamic conditions, both pulsatile flow (PF) and CF, were tested while recording both left and right atrial pressures (LAP and RAP), outlet pressures (aortic pressure [AoP] and pulmonary artery pressure [PAP]), flows, and Hall effect sensor output. There was a positive correlation of ≥0.80 ( p < 0.0001) between rotor position and flow, and a negative correlation of ≥−0.80 ( p < 0.0001) between rotor position and atrial balance, systemic vascular resistance (SVR), and LAP. The rotor’s maximum movement per cycle during pulsatile testing was 1.32 mm, and the minimum was 0.51 mm, indicating a significant positive correlation (≥0.80; p < 0.0001) with pulse pressure and flow pulse. The passive balancing features of P-CFTAH are effective across a range of steady-state conditions.
- 5 August 2026
- Published by Wolters Kluwer Health in ASAIO Journal
Automatic Balance Regulation in a Pediatric Total Artificial Heart
Unbalanced pressures and volumes between the right and left atrium will cause systemic and/or pulmonary congestion. The continuous-flow (CF) total artificial hearts (TAHs) developed at the Cleveland Clinic mitigate pressure imbalance by titrating right pump output via pressure-related changes in rotor axial position. Hall effect sensors were placed and calibrated at both ends of the pediatric CF TAH (P-CFTAH) stator bore to track the rotor’s permanent magnet location. The P-CFTAH was placed on a mock loop in water/glycerin, where several hemodynamic conditions, both pulsatile flow (PF) and CF, were tested while recording both left and right atrial pressures (LAP and RAP), outlet pressures (aortic pressure [AoP] and pulmonary artery pressure [PAP]), flows, and Hall effect sensor output. There was a positive correlation of ≥0.80 ( p < 0.0001) between rotor position and flow, and a negative correlation of ≥−0.80 ( p < 0.0001) between rotor position and atrial balance, systemic vascular resistance (SVR), and LAP. The rotor’s maximum movement per cycle during pulsatile testing was 1.32 mm, and the minimum was 0.51 mm, indicating a significant positive correlation (≥0.80; p < 0.0001) with pulse pressure and flow pulse. The passive balancing features of P-CFTAH are effective across a range of steady-state conditions.
- 11 July 2025
- Published by Springer Nature in Current Medical Science
- Vol. 45 (4) , 673-682
Expert Consensus on Clinical Application of Implantable Biventricular Assist Devices
While biventricular assist devices (BiVADs) remain underutilized in Western countries for biventricular heart failure (BHF), their application is expanding in China. This consensus synthesizes international guidelines, medical evidence, and Chinese clinical expertise to establish standardized protocols for BiVAD management. Key recommendations include: (1) Preoperative right heart catheterization and echocardiography for central venous pressure (CVP): pulmonary capillary wedge pressure (PCWP) ratio and pulmonary artery pulsatility index (PAPi) assessment (Class I); (2) BiVAD indication in refractory BHF or high-risk right heart failure post-left ventricular assist device (LVAD) implantation (Class IIa); (3) Right atrial implantation as the preferred surgical approach (Class IIa); (4) Warfarin-based anticoagulation (INR 2.0–2.5) with aspirin, avoiding direct oral anticoagulants (DOACs) (Class III). The guidance addresses critical gaps in patient selection, pump speed titration, and complication management, positioning integrated BiVAD systems as a promising solution for complex BHF.
- 11 July 2025
- Published by Springer Nature in Current Medical Science
- Vol. 45 (4) , 673-682
Expert Consensus on Clinical Application of Implantable Biventricular Assist Devices
While biventricular assist devices (BiVADs) remain underutilized in Western countries for biventricular heart failure (BHF), their application is expanding in China. This consensus synthesizes international guidelines, medical evidence, and Chinese clinical expertise to establish standardized protocols for BiVAD management. Key recommendations include: (1) Preoperative right heart catheterization and echocardiography for central venous pressure (CVP): pulmonary capillary wedge pressure (PCWP) ratio and pulmonary artery pulsatility index (PAPi) assessment (Class I); (2) BiVAD indication in refractory BHF or high-risk right heart failure post-left ventricular assist device (LVAD) implantation (Class IIa); (3) Right atrial implantation as the preferred surgical approach (Class IIa); (4) Warfarin-based anticoagulation (INR 2.0–2.5) with aspirin, avoiding direct oral anticoagulants (DOACs) (Class III). The guidance addresses critical gaps in patient selection, pump speed titration, and complication management, positioning integrated BiVAD systems as a promising solution for complex BHF.
- 31 January 2025
- Published by Wiley in Artificial Organs
- Vol. 49 (6) , 977-987
Atrial and Ventricular Cannulation for Biventricular Circulatory Support With Double‐Ended Centrifugal Pump: In Vitro Evaluation
Background: In patients with biventricular heart failure, a biventricular assist device (BVAD) may be necessary for hemodynamic support. BVAD inflows can be established through cannulation of the atrial (AC) and/or ventricular (VC) chambers, but no consensus exists on optimal cannulation techniques. This study aimed to characterize BVAD performance related to cannulation types (AC and VC) using a continuous‐flow total artificial heart (CFTAH) as the BVAD. Methods: Both methods of cannulation (AC and VC) were tested on a mock loop using dual pulsatile ventricles with valves (AB5000; Abiomed) paired as the native ventricles and a double‐ended centrifugal pump with two volutes, CFTAH, as a BVAD. Pressures were collected at the inlet and outlets of the AB5000 (LAP, RAP, AoP, and PAP) and the CFTAH (Lin, Rin, Lout, and Rout). The left and right flows exiting the CFTAH (LPF and RPF) and total flow (TF), exiting systemic resistance, were monitored. Several heart failure conditions were simulated with adjustment of the pneumatic pressures (AB5000). Results: Trends between the AC and VC are similar where RAP, Lin, and Lout decreased, and AoP, PAP, TF, LPF, and RPF increased with increased support. The trends differ in LAP with an increase during AC as opposed to a decrease during VC. As a result, with this setup, left–right balance is more easily achieved during VC. TF is higher with AC, even though LPF and RPF are lower. This signifies the flow going through the aortic valve (TF–LPF) and pulmonary valve (TF–RPF) is higher with AC. Conclusions: The increased TF and valvular flow favored AC for introducing a CFTAH as BVAD to the native heart in these conditions.
- 31 January 2025
- Published by Wiley in Artificial Organs
- Vol. 49 (6) , 977-987
Atrial and Ventricular Cannulation for Biventricular Circulatory Support With Double‐Ended Centrifugal Pump: In Vitro Evaluation
Background: In patients with biventricular heart failure, a biventricular assist device (BVAD) may be necessary for hemodynamic support. BVAD inflows can be established through cannulation of the atrial (AC) and/or ventricular (VC) chambers, but no consensus exists on optimal cannulation techniques. This study aimed to characterize BVAD performance related to cannulation types (AC and VC) using a continuous‐flow total artificial heart (CFTAH) as the BVAD. Methods: Both methods of cannulation (AC and VC) were tested on a mock loop using dual pulsatile ventricles with valves (AB5000; Abiomed) paired as the native ventricles and a double‐ended centrifugal pump with two volutes, CFTAH, as a BVAD. Pressures were collected at the inlet and outlets of the AB5000 (LAP, RAP, AoP, and PAP) and the CFTAH (Lin, Rin, Lout, and Rout). The left and right flows exiting the CFTAH (LPF and RPF) and total flow (TF), exiting systemic resistance, were monitored. Several heart failure conditions were simulated with adjustment of the pneumatic pressures (AB5000). Results: Trends between the AC and VC are similar where RAP, Lin, and Lout decreased, and AoP, PAP, TF, LPF, and RPF increased with increased support. The trends differ in LAP with an increase during AC as opposed to a decrease during VC. As a result, with this setup, left–right balance is more easily achieved during VC. TF is higher with AC, even though LPF and RPF are lower. This signifies the flow going through the aortic valve (TF–LPF) and pulmonary valve (TF–RPF) is higher with AC. Conclusions: The increased TF and valvular flow favored AC for introducing a CFTAH as BVAD to the native heart in these conditions.
- Open Access
- 13 September 2024
- Published by Elsevier in JTCVS Techniques
- Vol. 28, 124-131
Implantable continuous-flow total artificial heart for newborns and small pediatric patients: First report of working model
- 13 September 2024
- Published by Elsevier in JTCVS Techniques
- Vol. 28, 124-131
Open AccessImplantable continuous-flow total artificial heart for newborns and small pediatric patients: First report of working model
- Open Access
- 22 May 2024
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 11, 1426133
Editorial: Methods in treating heart failure—device and surgery approach
Editorial: Methods in treating heart failure—device and surgery approach
- 22 May 2024
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 11, 1426133
Open AccessEditorial: Methods in treating heart failure—device and surgery approach
Editorial: Methods in treating heart failure—device and surgery approach
- Open Access
- 22 May 2024
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 11, 1421550
Editorial: Mechanical circulatory support therapy for biventricular failure
Editorial: Mechanical circulatory support therapy for biventricular failure
- 22 May 2024
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 11, 1421550
Open AccessEditorial: Mechanical circulatory support therapy for biventricular failure
Editorial: Mechanical circulatory support therapy for biventricular failure
- 17 October 2023
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 70 (2) , 116-123
Cleveland Clinic Continuous-Flow Total Artificial Heart: Progress Report and Technology Update
Cleveland Clinic’s continuous-flow total artificial heart (CFTAH) is being developed at our institution and has demonstrated system reliability and optimal performance. Based on the results from recent chronic in vivo experiments, CFTAH has been revised, especially to improve biocompatibility. The purpose of this article is to report our progress in developing CFTAH. To improve biocompatibility, the right impeller, the pump housing, and the motor were reviewed for design revision. Updated design features were based on computational fluid dynamics analysis and observations from in vitro and in vivo studies. A new version of CFTAH was created, manufactured, and tested. All hemodynamic and pump-related parameters were observed and found to be within the intended ranges, and the new CFTAH yielded acceptable biocompatibility. Cleveland Clinic’s continuous-flow total artificial heart has demonstrated reliable performance, and has shown satisfactory progress in its development.
- 17 October 2023
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 70 (2) , 116-123
Cleveland Clinic Continuous-Flow Total Artificial Heart: Progress Report and Technology Update
Cleveland Clinic’s continuous-flow total artificial heart (CFTAH) is being developed at our institution and has demonstrated system reliability and optimal performance. Based on the results from recent chronic in vivo experiments, CFTAH has been revised, especially to improve biocompatibility. The purpose of this article is to report our progress in developing CFTAH. To improve biocompatibility, the right impeller, the pump housing, and the motor were reviewed for design revision. Updated design features were based on computational fluid dynamics analysis and observations from in vitro and in vivo studies. A new version of CFTAH was created, manufactured, and tested. All hemodynamic and pump-related parameters were observed and found to be within the intended ranges, and the new CFTAH yielded acceptable biocompatibility. Cleveland Clinic’s continuous-flow total artificial heart has demonstrated reliable performance, and has shown satisfactory progress in its development.
- 3 October 2023
- Published by Wiley in Artificial Organs
- Vol. 48 (2) , 182-190
Preservation of pulsatility with universal ventricular assist device: In vitro assessment for biventricular support
BackgroundThe objective of this study was to assess the pulsatility preservation capability of the universal ventricular assist device (UVAD) when used as a biventricular assist device (BVAD). This evaluation was conducted through an in vitro experiment, utilizing a pulsatile biventricular circulatory mock loop.MethodsTwo UVAD pumps were tested in a dual setup (BVAD) in the circulatory model with the simulated conditions of left heart failure (HF), right HF, and moderate/severe biventricular HF (BHF). The total flow, aortic pulse pressure, the pulse augmentation factor (PAF), the energy-equivalent pressure (EEP), and the surplus hemodynamic energy (SHE) were observed at various pump speeds to evaluate the pulsatility.ResultsThe aortic pulse pressure increased from the baseline (without pump) in all simulated hemodynamic conditions. The PAF ranged from 17%-35% in healthy, left HF, right HF, and mild BHF conditions, with the highest PAF of 90% being observed in the severe BHF condition. The EEP correlated with LVAD flow in all groups (R2 = 0.87-0.97) and increased from the baseline in all cases. The SHE peaked at approximately 5-6 L/min of LVAD support and was likely to decrease at higher LVAD pump flow. The largest decrease in SHE from the baseline, 53%, was observed in the mild BHF conditions with the highest LVAD and RVAD support.ConclusionsThe UVAD successfully demonstrated the ability to preserve pulsatility in vitro, and to optimize the cardiac output, as an isolated circulatory support device option (RVAD or LVAD) and when used for BVAD support. Biventricular support with UVAD amplified the aortic pulse pressure. The biventricular UVAD also preserved the EEP and the SHE.image
- 3 October 2023
- Published by Wiley in Artificial Organs
- Vol. 48 (2) , 182-190
Preservation of pulsatility with universal ventricular assist device: In vitro assessment for biventricular support
BackgroundThe objective of this study was to assess the pulsatility preservation capability of the universal ventricular assist device (UVAD) when used as a biventricular assist device (BVAD). This evaluation was conducted through an in vitro experiment, utilizing a pulsatile biventricular circulatory mock loop.MethodsTwo UVAD pumps were tested in a dual setup (BVAD) in the circulatory model with the simulated conditions of left heart failure (HF), right HF, and moderate/severe biventricular HF (BHF). The total flow, aortic pulse pressure, the pulse augmentation factor (PAF), the energy-equivalent pressure (EEP), and the surplus hemodynamic energy (SHE) were observed at various pump speeds to evaluate the pulsatility.ResultsThe aortic pulse pressure increased from the baseline (without pump) in all simulated hemodynamic conditions. The PAF ranged from 17%-35% in healthy, left HF, right HF, and mild BHF conditions, with the highest PAF of 90% being observed in the severe BHF condition. The EEP correlated with LVAD flow in all groups (R2 = 0.87-0.97) and increased from the baseline in all cases. The SHE peaked at approximately 5-6 L/min of LVAD support and was likely to decrease at higher LVAD pump flow. The largest decrease in SHE from the baseline, 53%, was observed in the mild BHF conditions with the highest LVAD and RVAD support.ConclusionsThe UVAD successfully demonstrated the ability to preserve pulsatility in vitro, and to optimize the cardiac output, as an isolated circulatory support device option (RVAD or LVAD) and when used for BVAD support. Biventricular support with UVAD amplified the aortic pulse pressure. The biventricular UVAD also preserved the EEP and the SHE.image