KCKinon Chen

Kinon Chen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Kinon Chen has a total of 52 co-authors. Here are the top co-authors by number of shared publications:

  • James David Weiland

    University of Michigan, Ann Arbor, USA

    5 shared publications
  • Jingchao Wang

    Key Laboratory of Biomechanics and Mechanobiology, Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100083, China

    4 shared publications
  • Yuan He

    Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Key Laboratory of Innovation and Transformation of Advanced Medical Devices, Ministry of Industry and Information Technology, National Medical Innovation Platform for Industry‐Education Integration in Advanced Medical Devices (Interdiscipline of Medicine and Engineering), School of Biological Science and Medical Engineering, Beihang University Beijing China

    3 shared publications
  • Yue Guo

    School of Biological Science and Medical Engineering, Beihang University (BUAA) - Yifu Science Hall, 37 Xueyuan Road, Haidian, Beijing, 100191, China; Beijing Advanced Innovation Center for Biomedical Engineering, BUAA, Beijing, 100191, China

    3 shared publications
  • Hai Hu

    School of Biological Science and Medical Engineering, Beihang University (BUAA)-Yifu Science Hall, Beijing, China

    2 shared publications
  • Meiyan Zhang

    School of Biological Science and Medical Engineering, Beihang University (BUAA)-Yifu Science Hall, Beijing, China

    2 shared publications

Latest Publications

  • Open Access

    A biomechanical optimized Zr 58 Cu 25 Al 14 Nb 3 bulk metallic glass dental implant improves peri‐implant stress distribution and bone quality under physiological loading

    by Yunshu Wu, Feifei Wang, Yuan He, Yaopeng Zhang, Yuhao Zeng, Fu Zheng, Zhanqi Wei, Sukun Tian, Kinon Chen, Baoan Sun, et al.

    While implant materials with bone‐mimetic elastic moduli are theoretically advantageous for reducing the stress shielding effect, the underlying mechanism remains incompletely understood, particularly in alveolar bone applications. In this study, we investigate the mechanism of excellent peri‐implant bone quality of a Zr 58 Cu 25 Al 14 Nb 3 bulk metallic glass (Nb3) dental implant in terms of its lower elastic modulus than commercial pure titanium (cpTi) and the stress distribution under masticatory mechanical loading. In vitro, Nb3 exhibited enhanced osteogenic potential over cpTi. In vivo, rat maxillary molar implants are subjected to a controllable cyclic loading program (10 N, 3 Hz, 0.12 s duration, 1800 cycles/day). The animal model coupled finite element analysis confirms that the lower elastic modulus of Nb3 implants promotes the more physiological stress distribution, and thus reduces stress concentration while increasing strain energy density in peri‐implant bone. Histomorphometry reveals that loaded Nb3 implants significantly accelerate mineral apposition rate, upregulate collagen III, and increase osteoblast density while reducing osteocyte number, demonstrating improved mechano‐adaptation. Transcriptomics identify coordinated upregulation of osteogenic, angiogenic, and mechanosensitive markers in Nb3‐loaded bone. Immunohistochemistry validates elevated expression of osteopontin and periostin, key mediators of mechanical signaling. These findings establish that Nb3's optimal elastic modulus enhances peri‐implant bone quality through biomechanical optimization of stress transfer that further activates mechanotransductive osteogenesis, providing a material‐based solution to stress shielding.

  • In-situ mineralized homogeneous collagen-based scaffolds for potential guided bone regeneration

    by Zhengwei Li, Tianming Du, Chongjian Gao, Lan Tang, Kinon Chen, Juan Liu, Jirong Yang, Xiaoli Zhao, Xufeng Niu, Changshun Ruan

    For guided bone regeneration (GBR) in clinical orthopedics, the importance of a suitable scaffold which can provide the space needed for bone regeneration and simultaneously promotes the new bone formation cannot be overemphasized. Due to its excellent biocompatibility, mechanical strength, and similarity in structure and composition to natural bone, the mineralized collagen-based scaffolds have been increasingly considered as promising GBR scaffolds. Herein, we propose a novel method to fabricate an in-situ mineralized homogeneous collagen-based scaffold (IMHCS) with excellent osteogenic capability for GBR by electrospinning the collagen solution in combination with essential mineral ions. The IMHCS exhibited homogeneous distribution of apatite crystals in electrospun fibers, which helped to achieve a significantly higher tensile strength than the pure collagen scaffold (CS) and the scaffold with directly added nano-hydroxyapatite particles (HAS). Furthermore, the IMHCS had significantly better cell compatibility, cell migration ratio, and osteogenic differentiation property than the HAS and CS. Therefore, the IMHCS not only retains traditional function of inhibiting fibroblast invasion, but also possesses excellent osteogenic differentiation property, indicating a robust alternative for GBR applications.


  • Pediatric spinal cord injury with radiographic abnormality: the Beijing experience

    by Zhewei Zou, Shaoyang Kang, Yuxin Hou, Kinon Chen


  • Open Access

    A histological study of atherosclerotic characteristics in age-related macular degeneration

    by Jingchao Wang, Hongpeng Zhang, Jing Ji, Lixuan Wang, Wenxin Lv, Yuan He, Xuan Li, Guangyu Feng, Kinon Chen


  • Pediatric Spinal Cord Injury without Radiographic Abnormality

    by Zhewei Zou, Anna Teng, Liuyi Huang, Xiuyuan Luo, Xinhao Wu, Haocheng Zhang, Kinon Chen

    Study Design.: Retrospective study. Objective.: To describe the epidemiology and clinical outcomes of pediatric patients with spinal cord injury (SCI) without radiographic abnormality (SCIWORA) in mainland China for the first time. Summary of Background Data.: SCIWORA is a syndrome that often occurs in children mainly due to the unique biomechanics of the pediatric spine. Although there have been numerous retrospective studies on pediatric SCIWORA, and mainland China has more patients with SCI than anywhere else, pediatric patients with SCIWORA in mainland China has not been described in any study. Methods.: Review of all cases with SCIWORA at Beijing Children's Hospital between July 2007 and December 2019. Results.: Of the 189 pediatric patients with SCI 140 had SCIWORA (age: 5.65 ± 2.60 years, male-to-female ratio: 2:5). Main causes of injuries were sports (41%, mostly backbend), falls (27%), traffic accidents (10%), and violence (8%). Lesions were located at the thoracic (77%), cervical (10%), multiple (5%), and lumbar (4%) levels. Incubation period was 2 ± 6 hours. Pathological characteristics of SCI were detected in 96% patients by magnetic resonance imaging (MRI). Based on the American Spinal Injury Association impairment scale (AIS), many patients had complete impairment (50% AIS A, 45% AIS B/C/D, 1% AIS E). Particularly, the five patients with normal MRI tended to have mild injury (AIS D) (P < 0.001), but they still showed abnormal reflex. In the one patient who could not be graded at all by AIS, his only functional deficits were abnormal upper and lower limb muscle tones. A total of 59% patients were treated with methylprednisolone, dexamethasone, or both. Out of 76 patients 59 showed neurological improvement before discharge. The only association among age, cause of injury, level of lesion, incubation period, AIS grade, type of corticosteroid therapy, and neurological improvement was between level of lesion and AIS grade (P < 0.001). Conclusion.: Demographic and clinical differences exist in patients with SCIWORA. MRI and detailed neurological examinations should both be performed for proper diagnosis. There is still a need to develop better treatment strategy for these patients. Level of Evidence: 4


  • Open Access

    Walking Function After Cervical Contusion and Distraction Spinal Cord Injuries in Rats

    by Yue Guo, Hai Hu, Jingchao Wang, Meiyan Zhang, Kinon Chen

    This study examines and compares the walking function in contusion and distraction spinal cord injury (SCI) mechanisms. Moderate contusion and distraction SCIs were surgically induced between C5 and C6 in Sprague-Dawley male rats. The CatWalk system was used to perform gait analysis of walkway walking. The ladder rung walking test was used to quantify skilled locomotor movements of ladder rung walking. It was found that the inter-paw coordination, paw support, front paw kinematics, hind paw kinematics, and skilled movements were significantly different before and after contusion and distraction. Step sequence duration, diagonal support, forelimb intensity, forelimb duty cycle, forelimb paw angle, and forelimb swing speed were more greatly affected in distraction than in contusion at 2 weeks post-injury, whereas hindlimb stand was more greatly affected in contusion than in distraction at 8 weeks post-injury. After 8 weeks post-injury, diagonal coupling—variation, girdle coupling—variation, ipsilateral coupling—mean, forelimb maximum contact at, forelimb intensity, forelimb paw angle, and number of forelimb misplacements recovered to normal in contusion but not in distraction, whereas step sequence duration, ipsilateral coupling—variation, forelimb stand, forelimb duty cycle, hindlimb swing duration, hindlimb swing speed, and number of forelimb slips recovered to normal in distraction but not in contusion. Some of the behavioral outcomes, but not the others, were linearly correlated with the histological outcomes. In conclusion, walking deficits and recovery can be affected by the type of common traumatic SCI.


  • Open Access

    Quantification of surviving neurons after contusion, dislocation, and distraction spinal cord injuries using automated methods

    by Jingchao Wang, Meiyan Zhang, Yue Guo, Hai Hu, Kinon Chen

    This study proposes and validates an automated method for counting neurons in spinal cord injury (SCI) and then uses it to examine and compare the surviving cells in common types of SCI mechanisms. Moderate contusion, dislocation, and distraction SCIs were surgically induced in Sprague Dawley male rats (n = 6 for each type of injury). Their spinal cords were harvested 8 weeks post injury with 5 normal weight-matched rats. The spinal cords were cut, stained with anti-NeuN antibody and fluorescent Nissl, and imaged in the dorsal and ventral horns at various distances to the epicenter. Neurons in the images were automatically counted using an algorithm that was designed to filter non-soma-like objects based on morphological characteristics (size, solidity, circular pattern) and check the remaining objects for the double-stained nucleus/cell body features (brightness variation, brightness distribution, color). To validate the automated method, some of the images were randomly selected for manual counting. The number of surviving cells that were automatically measured by the algorithm was found to be correlated with the values that were manually measured by 2 observers (P < .001) with similar differences (P > .05). Neurons in the dorsal and ventral horns were reduced after the SCIs (P < .05). Dislocation and distraction, respectively, caused the most severe damage to the ventral horn neurons especially near the epicenter and the most extensive and uniform damage to the dorsal horn neurons (P < .05). Our method was proved to be reliable, which is suitable for studying different types of SCI.


  • Open Access

    Mechanical Evaluation of Retinal Damage Associated With Blunt Craniomaxillofacial Trauma: A Simulation Analysis

    by Xiaoqi Geng, Xiaoyu Liu, Wei Wei, Yawei Wang, Lizhen Wang, Kinon Chen, Hongqiang Huo, Yuanjie Zhu, Yubo Fan

    Purpose: To evaluate retinal damage as the result of craniomaxillofacial trauma and explain its pathogenic mechanism using finite element (FE) simulation. Methods: Computed tomography (CT) images of an adult man were obtained to construct a FE skull model. A FE skin model was built to cover the outer surface of the skull model. A previously validated FE right eye model was symmetrically copied to create a FE left eye model, and both eye models were assembled to the skull model. An orbital fat model was developed to fill the space between the eye models and the skull model. Simulations of a ball-shaped object striking the frontal bone, temporal bone, brow, and cheekbones were performed, and the resulting absorption of the impact energy, intraocular pressure (IOP), and strains on the macula and ora serrata were analyzed to evaluate retinal injuries. Results: Strain was concentrated in the macular regions (0.18 in average) of both eyes when the frontal bone was struck. The peak strain on the macula of the struck-side eye was higher than that of the other eye (>100%) when the temporal bone was struck, whereas there was little difference (r > 0.8 and P = 0.000 in all simulation cases). Conclusions: The risk of retinal damage is variable in craniomaxillofacial trauma depending on the struck region, and the damage is highly related to IOP variation caused by indirect blunt eye trauma. Translational Relevance: This finite element eye model allows us to evaluate and understand the indirect ocular injury mechanisms in craniomaxillofacial trauma for better clinical diagnosis and treatment.


  • Viscoelastic properties of the posterior eye of normal subjects, patients with age‐related macular degeneration, and pigs

    by Zhen Huan Zhang, Meng Xin Pan, Jia Tong Cai, James D. Weiland, Kinon Chen

    The purpose of this study is to measure, characterize, and compare the viscoelastic properties of the posterior eye of advanced dry age‐related macular degeneration (AMD) patients, age‐matched normal subjects, and pigs (3 groups). Ten horizontal and ten vertical strips of the macula retina and the underneath choroid and sclera were obtained for each group, respectively. They were examined by incremental stress‐relaxation cycles in body‐temperature saline. Mechanical response was characterized by the quasi‐linear viscoelastic model. All the tissues were shown to be nonlinear viscoelastic. Stiffening and isotropization, increased relaxation, and softening and isotropization were found in AMD retina, choroid, and sclera, respectively, which are the mechanical features of the atherosclerotic process. The patients’ medical records were in accordance with epidemiological studies indicating a relationship between the advanced AMD and atherosclerotic vascular disease (ASVD). Moreover, many differences were found between the viscoelastic properties of porcine and normal human retina, choroid, and sclera. The results suggest that AMD is associated with ASVD through a mechanism involving abnormal retinal, choroidal, and scleral mechanics similar to those seen in the atherosclerotic process. Moreover, researchers should be aware of mechanical differences when using porcine posterior eyes as a substitute for human posterior eyes. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 2151‐2157, 2018.