RNRyo Nagaoka

Ryo Nagaoka

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ryo Nagaoka has a total of 74 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • One-transmission harmonic imaging with high spatial resolutions using probe consisting of two piezoelectric layer elements

    by Ryo Nagaoka, Shin-Ichiro Umemura, Masaaki Omura, Hideyuki Hasegawa

    Pulse inversion (PI) harmonic imaging has been commonly used because of its contrast and spatial resolution superior to conventional fundamental imaging. However, it requires two transmissions with opposite phases, which reduces the imaging frame rate by half. This study aimed to solve this problem METHOD: An ultrasonic array probe consisting of piezoelectric elements with two polarization-inverted layers, which requires only one transmission to extract the second harmonic components, was developed. Its characteristics, such as electric impedance and its phase, were predicted by solving piezoelectric as well as wave equations, and then compared with measurement. The acoustic pressures produced from the developed probe, when excited at the lower and higher resonant frequencies, were measured using a hydrophone. Finally, imaging of wires in water and phantoms containing wires and a cyst model were performed using the developed probe RESULT: The spatial resolution, especially in the axial direction, was significantly improved with the developed probe consisting of the two piezoelectric layer elements in comparison with the conventional second harmonic imaging (HI) using a band pass filter. It was almost comparable to that of conventional PI imaging despite only one transmission being required CONCLUSION: A probe consisting of two piezoelectric layer elements enabling one-transmission HI was developed. The spatial resolution obtained using the developed probe was slightly worse but almost comparable to that of conventional PI imaging even with only one transmission.

  • Blood flow visualization using a ConvLSTM-based deep learning clutter filter

    by Hongpeng Wang, Jiayi Li, Masaaki Omura, Ryo Nagaoka, Shangce Gao, Hideyuki Hasegawa

    The convolutional long short-term memory (ConvLSTM) model applied to high-frame-rate ultrasound data in this study visualized blood flow better than singular value decomposition (SVD) clutter filtering and closely followed the temporal velocity trends of the SVD results. The proposed two-layer ConvLSTM model was trained with Gaussian masking and masked mean square error (MSE) losses to emphasize vascular regions and suppress tissue clutter. Experiments showed that ConvLSTM effectively separated blood-flow and tissue components, achieving higher contrast than conventional SVD filtering. Velocity estimation using block-matching indicated that ConvLSTM closely tracked the temporal velocity trends of the SVD results. A slight increase in mean velocity during high-flow phases was attributed to delayed temporal accumulation caused by long-term memory. Designed to capture long-term temporal dependencies, the ConvLSTM model can extract hemodynamic features from sequential ultrasound data, enabling effective clutter suppression and stable visualization of blood flow in high-frame-rate imaging.

  • Investigation of effects from spatial coherence information on estimation of 2D velocity vectors using speckle tracking technique

    by Ryo Nagaoka, Liao Jing, Kei Kaneko, Muhammad Shiddiq Sayyid Hashuro, Masaaki Omura, Hitomi Anzai, Makoto Ohta, Hideyuki Hasegawa

    Applying the spatial coherence information (CI) to beamformed signals can improve the spatial resolution. This advantage of improvement has been taken to enhance the estimation accuracy of 2D velocity vectors using speckle tracking (ST) technique. In this paper, we performed more detailed numerical simulations taking distribution of scatterers for ultrasound and characteristics of the CI into consideration. As a result, there was few significant differences of the estimation accuracy of the vectors between the distribution of scatterers (2D or 3D) relating to all the CI at the fixed scatterer density. Also, when the density of the scatterers was altered, we investigated effects on the accuracy, and the results can be separated mainly into two different types. Consequently, in this paper, the results of the numerical simulation indicated that the ST technique without the CI had the best estimation accuracy.

  • Singular value decomposition–based suppression of undesired signals in multi-angle compound ultrasound imaging

    by Hideyuki Hasegawa, Masaaki Omura, Ryo Nagaoka, Kozue Saito

    Singular value decomposition (SVD) has been reported to effectively extract weak echoes from blood cells in biological tissues and has since been used as a signal decomposition filter for various purposes. This study examines the application of SVD to ultrasound beamforming. Beamforming was conducted at multiple receive-aperture positions, and an SVD filter was applied to the beamformed signals over all aperture positions. The reconstructed image obtained with SVD exhibited effective suppression of undesired signals compared with the multi-angle compound image without SVD filtering.

  • Open Access

    Preliminary Study on an Anti-Aliasing Approach for the Phase-Sensitive Motion Estimator

    by Hideyuki Hasegawa, Masaaki Omura, Ryo Nagaoka, Kozue Saito

    The autocorrelation method is widely used to estimate axial velocities in medical ultrasound imaging, such as color flow imaging, owing to its computational simplicity and robustness. However, its applicability is significantly limited by aliasing, whereby velocities exceeding the Nyquist limit are wrapped and may appear with reversed polarity. In this study, we propose an alternative approach in which the phases of received echo signals at multiple frequencies are analyzed using the Fourier transform. By evaluating the slope of the phase spectrum across frequencies, the target velocity corresponding to the displacement between successive transmissions can be estimated with increased tolerance to aliasing. Phase unwrapping becomes feasible as long as the phase difference between adjacent frequency components remains less than $\boldsymbol {\pi }$ , providing a theoretical basis for the proposed method. Consequently, the proposed phase-spectrum approach extends the aliasing limit compared with the conventional autocorrelation method, which relies only on the phase at the ultrasonic center frequency. A proof-of-concept numerical simulation clearly demonstrated a significant extension of the aliasing limit. In addition, the feasibility of the method was evaluated through an in vivo measurement of the human carotid artery, in which echo signals were acquired using non-steered single-angle plane wave imaging. While the conventional autocorrelation method exhibited clear aliasing effects, the proposed method successfully corrected velocity estimates with opposite polarity, thereby improving the applicability of blood flow assessment.

  • Open Access

    Investigation of Ultrasound Transmit–Receive Sequence That Enables Both High-Frame-Rate Vascular Wall Velocity Estimation and High-Contrast B-Mode Images

    by Hitoshi Hirano, Rikuto Suzuki, Masaaki Omura, Ryo Nagaoka, Kozue Saito, Hideyuki Hasegawa

    In this study, we designed an ultrasound transmit–receive sequence to achieve high-frame-rate vascular wall velocity estimation and high-contrast B-mode imaging. The proposed sequence extends conventional dual-transmission schemes by incorporating a third transmission with 180° phase inversion, enabling harmonic imaging via the pulse inversion (PI) method. To mitigate the frame rate reduction caused by the additional transmission, the number of simultaneously transmitted focused beams was increased from two to four, resulting in a frame rate of 231 Hz. A two-dimensional phase-sensitive motion estimator was employed for motion estimation. In vitro experiments using a chicken thigh moving in two dimensions yielded RMSE values of 3% (vertical) and 16% (horizontal). In vivo experiments on a human carotid artery demonstrated that the PI method achieved a lumen-to-tissue contrast improvement of 0.96 dB and reduced artifacts. Velocity estimation of the posterior vascular wall showed generally robust performance. These findings suggest that the proposed method has strong potential to improve atherosclerosis diagnostics by combining artifact-suppressed imaging with accurate motion analysis.


  • Estimation of velocity vectors and evaluation of accuracy using two types of multi-angle Doppler methods on improved stenotic vessel models

    by Kohei Suzuki, Masaaki Omura, Ryo Nagaoka, Kozue Saito, Hideyuki Hasegawa

    Carotid artery stenosis is a major risk factor for cerebrovascular disease, requiring accurate and early diagnosis. In this study, we propose an improved stenotic blood vessel model that accounts for in vivo vascular geometry. Using two transmit center frequencies, we evaluated accuracy in estimation of blood flow velocity vectors with a multi-angle Doppler method implemented via plane wave imaging (PWI) and multi-line transmission imaging (MLTI). Among the tested conditions, MLTI at 6.94 MHz achieved the lowest root mean square error excluding bias error (RMSEexBE). However, it exhibited the highest bias error (BE), and its lower aliasing limit led to velocity folding under severe stenosis. In contrast, while the RMSEexBE in PWI was slightly higher than that in MLTI, the BE was significantly lower.


  • Study on the effects of motion on an estimation method of average speed of sound

    by Miku Iida, Ryo Nagaoka, Muhammad Shiddiq Sayyid Hashuro, Kei Kaneko, Riko Hasegawa, Masaaki Omura, Makoto Ohta, Hideyuki Hasegawa

    In the image reconstruction of ultrasound B-mode images, an average speed of sound (SoS) in living tissue is assumed to be a constant value. However, the assumed value may be different with the true values because the SoS varies depending on the properties of the tissue. The error between the true and assumed SoS causes degradation of ultrasound B-mode images. We have proposed a method for estimating an average SoS distribution. In this study, we conducted numerical simulations and evaluated the effects of motion on the average SoS estimation method. Furthermore, we conducted phantom experiments. In both the numerical simulation and phantom experiment, when a B-mode image was reconstructed using the estimated average SoS distribution, the contrast value was improved regardless of the motions.


  • Comparison of singular value decomposition filter frameworks for pre- and post-beamformed data of blood flow echo signals

    by Masahiro Matsuzaki, Masaaki Omura, Ryo Nagaoka, Hideyuki Hasegawa

    Singular value decomposition (SVD)-based clutter filters effectively separate tissue, blood flow, and noise components. This study compares post-beamformed (conventional) and pre-beamformed (proposed) data with SVD-based filters to enhance the blood flow echo. Using simulation, experimental, and in vivo data, the image contrast was evaluated in the blood flow against different locations in near- and far-tissues, and blood flow itself. The suppression of the tissue component was more improved in the proposed method while the conventional method achieved comparable or higher contrast in blood flow itself. This improvement was attributed to better suppression of tissue signals in the pre-beamformed processing.


  • Open Access

    Multiple reflections in three-dimensional images of scanning acoustic microscopy indicate fine cell-cell spatial interrelationship

    by Maki Shibata, Yuki Kawaguchi, Naohiro Hozumi, Kazuki Tamura, Ryo Nagaoka, Kazuto Kobayashi, Sachiko Yoshida

    Scanning acoustic microscopy is an effective tool for non-invasive observation of living cells’ elasticity based on acoustic impedance (AI). This tool allows the visualization of intracellular three-dimensional structures in the depth direction. Here, we investigated the mechanism of the appearance of artifactual AI images in three-dimensional tomography using various cellular conditions. These ghost AI images were derived from prolonged reflection waves in the time domain, and multiple reflections between cell-cell gap structure and intracellular elastic materials were synthesized, causing complex ghost images. Synthesized reflection waves contained information on specific intracellular spaces and the distribution of intracellular elastic components. The ghost images derived from reflection waves were weak in non-biological interactions. Our result suggests complex reflections of AI would not only be a ghost-image maker but also transfer information about invisible delicate structures in cultured cells. This reflection analysis would be useful for detecting artificial organs’ differentiation and cell-cell connection.