Vaibhav Jain
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Vaibhav Jain has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Gulshan Sachdeva
19 shared publications- Surendra Singh Kachhwaha
Pandit Deendayal Energy University
14 shared publications Ashu Singhal
3 shared publications- Anuradha Parinam
Department of Mechanical Engineering University Institute of Engineering and Technology, Kurukshetra University Kurukshetra India
2 shared publications Bhavesh Patel
2 shared publicationsHarsh Joshi
Maharaja Agrasen Institute of Technology
2 shared publications
Latest Publications
- Open Access
- 6 October 2026
- Published by Springer Nature in International Journal of Air-Conditioning and Refrigeration
- Vol. 34 (1) , 24
Design and performance assessment of a modular carbon capture-algal utilization retrofit for residential heating
Rising carbon emissions from fossil-fuel-based space heating highlight the need for retrofit solutions deployed at scale. This study presents a modular carbon capture and utilization (CCU) system designed for integration with residential and light-commercial HVAC&R infrastructure. The system captures post-combustion CO₂ using a multi-stage filtration and pressure swing adsorption (PSA) unit, then feeds the captured gas to a photobioreactor (PBR) cultivating Chlorella vulgaris. The resulting algal biomass is processed into biodiesel, enabling on-site conversion of emissions into usable fuel. Modelled for a standard 20-kW natural gas boiler, the system demonstrates the capacity to capture over 7 metric tons of CO₂ per heating season while generating appreciable quantities of biomass and renewable fuel. This biodiesel production contributes significantly to reducing the annual heating energy demand. The biodiesel provides 10,798.4 kWh of fuel energy, contributing 8638.86 kWh to heating demand at 80% boiler efficiency. While the system displaces 1.74 tCO₂e/year of fossil natural gas through fuel substitution, the ~ 7.78 t of CO₂ captured per season is cycled through the biological loop rather than permanently sequestered. Techno-economic analysis, estimates a capital cost of approximately $5,900, a simple payback period of approximately 22 years, and a 10-year present value of the net-benefit stream of approximately $1,660. These results demonstrate the technical feasibility of small-scale CCU retrofits for reducing emissions from existing heating systems, while showing that single-household economics are not yet cost-competitive; centralized, cluster-scale deployment is identified as a promising direction for closing this gap.
- 6 October 2026
- Published by Springer Nature in International Journal of Air-Conditioning and Refrigeration
- Vol. 34 (1) , 24
Open AccessDesign and performance assessment of a modular carbon capture-algal utilization retrofit for residential heating
Rising carbon emissions from fossil-fuel-based space heating highlight the need for retrofit solutions deployed at scale. This study presents a modular carbon capture and utilization (CCU) system designed for integration with residential and light-commercial HVAC&R infrastructure. The system captures post-combustion CO₂ using a multi-stage filtration and pressure swing adsorption (PSA) unit, then feeds the captured gas to a photobioreactor (PBR) cultivating Chlorella vulgaris. The resulting algal biomass is processed into biodiesel, enabling on-site conversion of emissions into usable fuel. Modelled for a standard 20-kW natural gas boiler, the system demonstrates the capacity to capture over 7 metric tons of CO₂ per heating season while generating appreciable quantities of biomass and renewable fuel. This biodiesel production contributes significantly to reducing the annual heating energy demand. The biodiesel provides 10,798.4 kWh of fuel energy, contributing 8638.86 kWh to heating demand at 80% boiler efficiency. While the system displaces 1.74 tCO₂e/year of fossil natural gas through fuel substitution, the ~ 7.78 t of CO₂ captured per season is cycled through the biological loop rather than permanently sequestered. Techno-economic analysis, estimates a capital cost of approximately $5,900, a simple payback period of approximately 22 years, and a 10-year present value of the net-benefit stream of approximately $1,660. These results demonstrate the technical feasibility of small-scale CCU retrofits for reducing emissions from existing heating systems, while showing that single-household economics are not yet cost-competitive; centralized, cluster-scale deployment is identified as a promising direction for closing this gap.
- Open Access
- 19 March 2024
- Published by Springer Nature in International Journal of Air-Conditioning and Refrigeration
- Vol. 32 (1) , 1-17
Performance analysis of a novel ejector-assisted condenser outlet split dual-evaporator refrigeration system
The performance of an ejector-assisted condenser outlet split dual-evaporator cycle is compared with a conventional dual-evaporator cycle albeit consisting a pressure reducing valve. The cycles do not employ any separator due to its inability to efficiently separate the liquid and the vapor phases. The comparison of both the cycles has been made for the same cooling capacity in low-temperature evaporator and unit flow rate of R134a and R1234yf as refrigerants. The impacts of changing the operating temperatures of evaporator and condenser have been examined in the current investigation. The study reveals that with the increase in temperature of the high-temperature evaporator, the cooling capacity of the high-temperature evaporator yields, while that of the low-temperature evaporator plummets in both the cycles. Further, the compressor work is allayed in the ejector-assisted cycle; thus, the COP is enhanced considerably. The percentage COP improvement over the basic cycle is obtained from 14.7 to 17.53% for the refrigerant R1234yf and from 14.45 to 17.32% for R134a; however, the COP of both the cycles with R12134yf is slightly lower than with R134a. The ejector has been modeled assuming a constant pressure theory. The observed trend indicates that the entrainment ratio is improved with the rise in the temperature of low-temperature evaporator, whereas it is decreased with the rise in the temperature of high-temperature evaporator.
- 19 March 2024
- Published by Springer Nature in International Journal of Air-Conditioning and Refrigeration
- Vol. 32 (1) , 1-17
Open AccessPerformance analysis of a novel ejector-assisted condenser outlet split dual-evaporator refrigeration system
The performance of an ejector-assisted condenser outlet split dual-evaporator cycle is compared with a conventional dual-evaporator cycle albeit consisting a pressure reducing valve. The cycles do not employ any separator due to its inability to efficiently separate the liquid and the vapor phases. The comparison of both the cycles has been made for the same cooling capacity in low-temperature evaporator and unit flow rate of R134a and R1234yf as refrigerants. The impacts of changing the operating temperatures of evaporator and condenser have been examined in the current investigation. The study reveals that with the increase in temperature of the high-temperature evaporator, the cooling capacity of the high-temperature evaporator yields, while that of the low-temperature evaporator plummets in both the cycles. Further, the compressor work is allayed in the ejector-assisted cycle; thus, the COP is enhanced considerably. The percentage COP improvement over the basic cycle is obtained from 14.7 to 17.53% for the refrigerant R1234yf and from 14.45 to 17.32% for R134a; however, the COP of both the cycles with R12134yf is slightly lower than with R134a. The ejector has been modeled assuming a constant pressure theory. The observed trend indicates that the entrainment ratio is improved with the rise in the temperature of low-temperature evaporator, whereas it is decreased with the rise in the temperature of high-temperature evaporator.
- 9 December 2023
- Published by Elsevier in Energy Conversion and Management
- Vol. 300
Experimental analysis of an ejector assisted dual-evaporator vapor compression system
- 9 December 2023
- Published by Elsevier in Energy Conversion and Management
- Vol. 300
Experimental analysis of an ejector assisted dual-evaporator vapor compression system
- Open Access
- 7 August 2023
- Published by Springer Nature in International Journal of Air-Conditioning and Refrigeration
- Vol. 31 (1) , 1-16
Comparative performance investigation of a dual evaporator cycle using an ejector with the conventional cycle using a pressure reducing valve
The performance of a dual evaporator cycle using ejector is compared with a conventional cycle employing pressure reducing valve. In both the systems, high temperature evaporator is considered as a flooded evaporator, thus a separator is employed after the high temperature evaporator. However, low temperature evaporator is a kind of conventional dry evaporator. The comparison of both systems, i.e., conventional and ejector assisted, is done for the same cooling capacities and same dryness fraction at the exit of high temperature evaporator with R134a, R152a, and R1234yf refrigerants. The effects of varying the states of refrigerant at the exit of flooded evaporator, and temperatures of both the evaporators and the condenser are analyzed using Engineering Equation Solver. It is found that the compressor work is reduced in both the cycles with the rise in low temperature evaporator temperature; however, a little variation is observed in the total cooling effect. The cooling effect in high temperature evaporator is increased with the increase in dryness fraction at the exit of the high temperature flooded evaporator, but it is decreased in low temperature evaporator.
- 7 August 2023
- Published by Springer Nature in International Journal of Air-Conditioning and Refrigeration
- Vol. 31 (1) , 1-16
Open AccessComparative performance investigation of a dual evaporator cycle using an ejector with the conventional cycle using a pressure reducing valve
The performance of a dual evaporator cycle using ejector is compared with a conventional cycle employing pressure reducing valve. In both the systems, high temperature evaporator is considered as a flooded evaporator, thus a separator is employed after the high temperature evaporator. However, low temperature evaporator is a kind of conventional dry evaporator. The comparison of both systems, i.e., conventional and ejector assisted, is done for the same cooling capacities and same dryness fraction at the exit of high temperature evaporator with R134a, R152a, and R1234yf refrigerants. The effects of varying the states of refrigerant at the exit of flooded evaporator, and temperatures of both the evaporators and the condenser are analyzed using Engineering Equation Solver. It is found that the compressor work is reduced in both the cycles with the rise in low temperature evaporator temperature; however, a little variation is observed in the total cooling effect. The cooling effect in high temperature evaporator is increased with the increase in dryness fraction at the exit of the high temperature flooded evaporator, but it is decreased in low temperature evaporator.
- 19 December 2020
- Published by Springer Nature in International Journal of Air-Conditioning and Refrigeration
- Vol. 28 (04)
Multi-Objective Optimization of Cascade Refrigeration System Using the Concept of Modified and Advanced Exergy, Risk Level and Thermal Inventory
This work conceives the performance of vapor compression cascaded refrigeration system (CRS) from the exergy, safety and thermal inventory points of view employing the theory of effective temperature ([ ] than environment temperature ([ ] in Gouy–Stodola equation. Comparative results show that the actual irreversible loss in CRS is 8.1% higher. Further, advanced exergy analysis results showed that 17.985[ ]kW irreversible loss (out of 33.737[ ]kW irreversible loss) in the system is evadable with improvement in the system design. Besides, the vulnerability of toxic fluid R717 is reported in terms of the total risk level. Moreover, the economy matter is expressed in terms of its total thermal inventory. At the base case, total risk level and total thermal inventory are determined to be 454.3 US$ and 48.86[ ]kW/K, respectively. First, sensitivity analysis is carried out to evaluate the variation in irreversible loss, total risk level and thermal inventory at different evaporator and condenser temperatures with different degrees of overlap (decision variables). A total of nine simulations are designed using the Taguchi technique. Later, multi-objective optimization is employed. The optimization process reduced the total irreversibility and annual risk level of CRS by 10.2% and 8.9%, respectively, with 6.8% increase in thermal inventory.
- 19 December 2020
- Published by Springer Nature in International Journal of Air-Conditioning and Refrigeration
- Vol. 28 (04)
Multi-Objective Optimization of Cascade Refrigeration System Using the Concept of Modified and Advanced Exergy, Risk Level and Thermal Inventory
This work conceives the performance of vapor compression cascaded refrigeration system (CRS) from the exergy, safety and thermal inventory points of view employing the theory of effective temperature ([ ] than environment temperature ([ ] in Gouy–Stodola equation. Comparative results show that the actual irreversible loss in CRS is 8.1% higher. Further, advanced exergy analysis results showed that 17.985[ ]kW irreversible loss (out of 33.737[ ]kW irreversible loss) in the system is evadable with improvement in the system design. Besides, the vulnerability of toxic fluid R717 is reported in terms of the total risk level. Moreover, the economy matter is expressed in terms of its total thermal inventory. At the base case, total risk level and total thermal inventory are determined to be 454.3 US$ and 48.86[ ]kW/K, respectively. First, sensitivity analysis is carried out to evaluate the variation in irreversible loss, total risk level and thermal inventory at different evaporator and condenser temperatures with different degrees of overlap (decision variables). A total of nine simulations are designed using the Taguchi technique. Later, multi-objective optimization is employed. The optimization process reduced the total irreversibility and annual risk level of CRS by 10.2% and 8.9%, respectively, with 6.8% increase in thermal inventory.
- 1 November 2020
- Published by Elsevier in Energy Conversion and Management
- Vol. 224
Advanced exergy analysis and risk estimation of novel NH3-H2O and H2O-LiBr integrated vapor absorption refrigeration system
- 1 November 2020
- Published by Elsevier in Energy Conversion and Management
- Vol. 224
Advanced exergy analysis and risk estimation of novel NH3-H2O and H2O-LiBr integrated vapor absorption refrigeration system
- 1 November 2020
- Published by Elsevier in Energy Conversion and Management
- Vol. 224
Thermoeconomic and feasibility analysis of novel transcritical vapor compression-absorption integrated refrigeration system
- 1 November 2020
- Published by Elsevier in Energy Conversion and Management
- Vol. 224
Thermoeconomic and feasibility analysis of novel transcritical vapor compression-absorption integrated refrigeration system
- 25 September 2020
- Published by Springer Nature
- p. 47-59
Exergy Analysis of Novel Combined Absorption Refrigeration System
- 25 September 2020
- Published by Springer Nature
- p. 47-59
Exergy Analysis of Novel Combined Absorption Refrigeration System
- 29 August 2019
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 16 (13) , 1024-1045
Performance analysis and multi-objective optimization of cooling tower assisted vapor compression-absorption cascaded and hybrid refrigeration systems
Present work compares and optimizes the performance of cooling tower assisted cascaded and hybrid configurations of vapor compression-absorption integrated refrigeration system. Both the sy...
- 29 August 2019
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 16 (13) , 1024-1045
Performance analysis and multi-objective optimization of cooling tower assisted vapor compression-absorption cascaded and hybrid refrigeration systems
Present work compares and optimizes the performance of cooling tower assisted cascaded and hybrid configurations of vapor compression-absorption integrated refrigeration system. Both the sy...
- 25 January 2019
- Published by Taylor & Francis in International Journal of Ambient Energy
- Vol. 42 (5) , 576-585
Thermodynamic analysis of ejector-assisted vapour compression–absorption hybrid refrigeration system
The vapor compression-absorption hybrid refrigeration system (VCAHRS) is a potential alternative refrigeration technology as it economizes the use of energy resources. The main issues observed with VCAHRS are low overall COP and large size of system which is mainly due to the poor performance of absorption section. Absorption section while assisted by ejector can improve the overall performance of VCAHRS. It is shown that at low generator temperatures, the ejector assisted absorption section provides better performance than the conventional absorption system adapted in VCAHRS. Simulation results show that the overall COP of VCAHRS is improved by 22.6%; whereas, the COP improvement of 25.2% is observed in the absorption section. The total irreversibility of the system is reduced by 38.8% using ejector at optimum generator temperature which is found to be 92.1°C while varying it from 117.9 °C. Therefore, ejector assisted VCAHRS also permits the utilization of low temperature heat source.
- 25 January 2019
- Published by Taylor & Francis in International Journal of Ambient Energy
- Vol. 42 (5) , 576-585
Thermodynamic analysis of ejector-assisted vapour compression–absorption hybrid refrigeration system
The vapor compression-absorption hybrid refrigeration system (VCAHRS) is a potential alternative refrigeration technology as it economizes the use of energy resources. The main issues observed with VCAHRS are low overall COP and large size of system which is mainly due to the poor performance of absorption section. Absorption section while assisted by ejector can improve the overall performance of VCAHRS. It is shown that at low generator temperatures, the ejector assisted absorption section provides better performance than the conventional absorption system adapted in VCAHRS. Simulation results show that the overall COP of VCAHRS is improved by 22.6%; whereas, the COP improvement of 25.2% is observed in the absorption section. The total irreversibility of the system is reduced by 38.8% using ejector at optimum generator temperature which is found to be 92.1°C while varying it from 117.9 °C. Therefore, ejector assisted VCAHRS also permits the utilization of low temperature heat source.