Andre Nicklas
Research Subjects
Andre Nicklas has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Udo Nagele
Department of Urology and Andrology, General Hospital Hall in Tirol, Milser Str. 10, 6060, Hall in Tirol, Austria.
4 shared publications David Schilling
Department of Urology and Pediatric Urology, University Hospital Frankfurt , Frankfurt, Germany
2 shared publicationsA. S. Merseburger
Department of Urology and Urooncology, Hannover Medical School, Hannover, Germany
1 shared publicationAristotelis G. Anastasiadis
Eilenriede Clinic Hannover
1 shared publicationAxel Haferkamp
Department of Urology and Pediatric Urology, University Hospital Frankfurt , Frankfurt, Germany
1 shared publicationAxel S. Merseburger
Hannover Medical School
1 shared publication
Latest Publications
- 1 April 2016
- Published by SAGE Publications in Journal of Endourology
- Vol. 30 (4) , 441-446
Clearance of Stone Fragments and Stone Dust by Continuous Flow Hydrodynamics in Percutaneous Renal Surgery: An In Vitro Study
Purpose: To investigate the capacity of stone clearance in common percutaneous nephrolithotomy (PCNL) systems achieved solely by hydrodynamic effects in an in vitro setting. Methods: A watertight cylindrical cast with a caliceal void served as an in vitro model. Various instruments for percutaneous renal surgery working with both continuous flow (fCF) and open Rutner sidearm (fCO) were tested. The model was loaded with standardized artificial stone material (2 mm in diameter) to examine stone removal by the vacuum cleaner effect and with sand (0.1–0.5 mm in diameter) to measure the washout effect caused by irrigation backflow. The association between washout of gravel and irrigation pressure was analyzed using ANOVA. Regression analysis was performed to assess the influence of the instruments' hydrodynamic characteristics—effective cross section of the outflow and irrigation flow volume. Results: Provoking the vacuum cleaner effect removal of stones was only effective in fCF but not in fCO instruments. Depending on irrigation pressure, the volumetric flow rate and effective cross section of the outflow clearance of sand could be observed in various medium- and large-sized fCF and fCO instruments, whereas in small-sized systems, clearance effects were negligible. Regression analysis showed clearance of stone dust strongly associated with an instrument's volumetric flow rate. Conclusions: This in vitro study demonstrated that the application of medium- and large-sized fCF PCNL systems removes both “insignificant” stones and dust solely by hydrodynamic effects. Further studies have to show if these effects also occur in the in vivo situation.
- 1 April 2016
- Published by SAGE Publications in Journal of Endourology
- Vol. 30 (4) , 441-446
Clearance of Stone Fragments and Stone Dust by Continuous Flow Hydrodynamics in Percutaneous Renal Surgery: An In Vitro Study
Purpose: To investigate the capacity of stone clearance in common percutaneous nephrolithotomy (PCNL) systems achieved solely by hydrodynamic effects in an in vitro setting. Methods: A watertight cylindrical cast with a caliceal void served as an in vitro model. Various instruments for percutaneous renal surgery working with both continuous flow (fCF) and open Rutner sidearm (fCO) were tested. The model was loaded with standardized artificial stone material (2 mm in diameter) to examine stone removal by the vacuum cleaner effect and with sand (0.1–0.5 mm in diameter) to measure the washout effect caused by irrigation backflow. The association between washout of gravel and irrigation pressure was analyzed using ANOVA. Regression analysis was performed to assess the influence of the instruments' hydrodynamic characteristics—effective cross section of the outflow and irrigation flow volume. Results: Provoking the vacuum cleaner effect removal of stones was only effective in fCF but not in fCO instruments. Depending on irrigation pressure, the volumetric flow rate and effective cross section of the outflow clearance of sand could be observed in various medium- and large-sized fCF and fCO instruments, whereas in small-sized systems, clearance effects were negligible. Regression analysis showed clearance of stone dust strongly associated with an instrument's volumetric flow rate. Conclusions: This in vitro study demonstrated that the application of medium- and large-sized fCF PCNL systems removes both “insignificant” stones and dust solely by hydrodynamic effects. Further studies have to show if these effects also occur in the in vivo situation.
- 2 April 2015
- Published by Springer Nature in World Journal of Urology
- Vol. 33 (11) , 1847-1853
The vacuum cleaner effect in minimally invasive percutaneous nephrolitholapaxy
Percutaneous stone removal increasingly plays an important role among the different approaches of interventional stone therapy, particularly since the development of miniaturized instruments is resulting in lower morbidity for the patients. One major drawback of smaller instruments is the increased difficulty of stone retrieval after disintegration due to the reduced tract diameter. This results in longer operation time and the need of additional tools such as disposable retrieval baskets. One of the key factors in the development of minimally invasive percutaneous nephrolitholapaxy (MIP) was the design of an Amplatz sheath which provides a built-in vacuum cleaner effect for stone retrieval. A series of flow analyses with the gauges and shapes of the most commonly used nephroscopes and sheaths in percutaneous nephrolitholapaxy was performed by computational fluid dynamics. Flow velocity and direction in front of the nephroscope were computed and visualized by the software. In our study, the vacuum cleaner effect developed exclusively when a round-shaped nephroscope was used (Nagele Miniature Nephroscope System, Karl Storz GmbH & Co. KG) and depended on the relation between nephroscope diameter and inner sheath diameter. The strongest effect was observed with a 12 F nephroscope and an inner sheath diameter of 15 F. It did not develop when an oval- or crescent-shaped nephroscope was used. In front of the distal end of the round-shaped nephroscope, a slipstream develops, induced by the excursive change of width of the fluid flow on the outlet of the flushing canal. This allows the adhesion of a stone fragment in the eddy while the fluid flow is circulating around the stone. This study illustrates and explains the vacuum cleaner effect which has been detected in the development of the Nagele Miniature Nephroscope System used in MIP. It combines the reduced morbidity of smaller kidney puncture diameters with the benefit of quick and complete stone removal.
- 2 April 2015
- Published by Springer Nature in World Journal of Urology
- Vol. 33 (11) , 1847-1853
The vacuum cleaner effect in minimally invasive percutaneous nephrolitholapaxy
Percutaneous stone removal increasingly plays an important role among the different approaches of interventional stone therapy, particularly since the development of miniaturized instruments is resulting in lower morbidity for the patients. One major drawback of smaller instruments is the increased difficulty of stone retrieval after disintegration due to the reduced tract diameter. This results in longer operation time and the need of additional tools such as disposable retrieval baskets. One of the key factors in the development of minimally invasive percutaneous nephrolitholapaxy (MIP) was the design of an Amplatz sheath which provides a built-in vacuum cleaner effect for stone retrieval. A series of flow analyses with the gauges and shapes of the most commonly used nephroscopes and sheaths in percutaneous nephrolitholapaxy was performed by computational fluid dynamics. Flow velocity and direction in front of the nephroscope were computed and visualized by the software. In our study, the vacuum cleaner effect developed exclusively when a round-shaped nephroscope was used (Nagele Miniature Nephroscope System, Karl Storz GmbH & Co. KG) and depended on the relation between nephroscope diameter and inner sheath diameter. The strongest effect was observed with a 12 F nephroscope and an inner sheath diameter of 15 F. It did not develop when an oval- or crescent-shaped nephroscope was used. In front of the distal end of the round-shaped nephroscope, a slipstream develops, induced by the excursive change of width of the fluid flow on the outlet of the flushing canal. This allows the adhesion of a stone fragment in the eddy while the fluid flow is circulating around the stone. This study illustrates and explains the vacuum cleaner effect which has been detected in the development of the Nagele Miniature Nephroscope System used in MIP. It combines the reduced morbidity of smaller kidney puncture diameters with the benefit of quick and complete stone removal.
- 8 July 2011
- Published by Springer Nature in World Journal of Urology
- Vol. 30 (5) , 625-631
Natural orifice (NOTES) transurethral sutureless radical prostatectomy with thulium laser support: first patient report
The aim of this descriptive study was to demonstrate the feasibility and safety of the first true transurethral sutureless radical prostatectomy for prostate cancer in humans using the NOTES technique. A 77-year-old man with clinically localized bilateral prostate cancer (Gleason 3 + 4 = 7 in 80% of 12 biopsy cores) and a serum PSA level of 2.1 ng/ml underwent our first natural orifice transurethral radical thulium laser prostatectomy within toto organ retrieval via sectio alta. The surgical procedure is described. The procedure was completed successfully. Overall operation time was 312 min; laser time was 46 min with 151 KJ. Postoperative hemoglobin was 9.4 g/dl, and the hematocrit was 28%. A cystogram on the 7th postoperative day showed no signs of extravasation and the transurethral catheter was removed, and a flexible cystoscopy on the 9th day demonstrated a sufficient arbitrarily sphincter closure against irrigation flow. The presented descriptive report demonstrates that natural orifice transurethral radical thulium laser prostatectomy for prostate cancer is feasible and safe. Potential candidates include older patients with low-risk cancers and urinary obstruction. Further prospective reports are necessary to evaluate functional and oncological outcome for this innovative technique.
- 8 July 2011
- Published by Springer Nature in World Journal of Urology
- Vol. 30 (5) , 625-631
Natural orifice (NOTES) transurethral sutureless radical prostatectomy with thulium laser support: first patient report
The aim of this descriptive study was to demonstrate the feasibility and safety of the first true transurethral sutureless radical prostatectomy for prostate cancer in humans using the NOTES technique. A 77-year-old man with clinically localized bilateral prostate cancer (Gleason 3 + 4 = 7 in 80% of 12 biopsy cores) and a serum PSA level of 2.1 ng/ml underwent our first natural orifice transurethral radical thulium laser prostatectomy within toto organ retrieval via sectio alta. The surgical procedure is described. The procedure was completed successfully. Overall operation time was 312 min; laser time was 46 min with 151 KJ. Postoperative hemoglobin was 9.4 g/dl, and the hematocrit was 28%. A cystogram on the 7th postoperative day showed no signs of extravasation and the transurethral catheter was removed, and a flexible cystoscopy on the 9th day demonstrated a sufficient arbitrarily sphincter closure against irrigation flow. The presented descriptive report demonstrates that natural orifice transurethral radical thulium laser prostatectomy for prostate cancer is feasible and safe. Potential candidates include older patients with low-risk cancers and urinary obstruction. Further prospective reports are necessary to evaluate functional and oncological outcome for this innovative technique.
- 9 February 2011
- Published by Springer Nature in World Journal of Urology
- Vol. 29 (4) , 423-427
Waterjet hydrodissection: first experiences and short-term outcomes of a novel approach to bladder tumor resection
- 9 February 2011
- Published by Springer Nature in World Journal of Urology
- Vol. 29 (4) , 423-427
Waterjet hydrodissection: first experiences and short-term outcomes of a novel approach to bladder tumor resection