Yongtian He
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yongtian He has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Jose Luis Contreras-Vidal
University of Houston
14 shared publications - Sho Nakagome
Meta, United States
6 shared publications Trieu Phat Luu
Noninvasive Brain-Machine Interface System Laboratory, University of Houston, Houston, TX 77004, USA
6 shared publicationsKevin Nathan
Noninvasive Brain-Machine Interface System Laboratory, University of Houston, Houston, TX 77004, USA
5 shared publications- Trieu Phat Luu
Baker Hughes, United States
5 shared publications Sho Nakagome
Noninvasive Brain-Machine Interface System Laboratory, University of Houston, Houston, TX 77004, USA
4 shared publications
Latest Publications
- 21 January 2022
- Published by Springer Nature
- p. 1-39
Deep Learning Methods for EEG Neural Classification
- 21 January 2022
- Published by Springer Nature
- p. 1-39
Deep Learning Methods for EEG Neural Classification
- Open Access
- 12 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Engineering in Medicine and Biology
- Vol. 2, 84-90
A Roadmap Towards Standards for Neurally Controlled End Effectors
The control and manipulation of various types of end effectors such as powered exoskeletons, prostheses, and ‘neural’ cursors by brain-machine interface (BMI) systems has been the target of many research projects. A seamless “plug and play” interface between any BMI and end effector is desired, wherein similar user's intent cause similar end effectors to behave identically. This report is based on the outcomes of an IEEE Standards Association Industry Connections working group on End Effectors for Brain-Machine Interfacing that convened to identify and address gaps in the existing standards for BMI-based solutions with a focus on the end-effector component. A roadmap towards standardization of end effectors for BMI systems is discussed by identifying current device standards that are applicable for end effectors. While current standards address basic electrical and mechanical safety, and to some extent, performance requirements, several gaps exist pertaining to unified terminologies, data communication protocols, patient safety and risk mitigation.
- 12 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Engineering in Medicine and Biology
- Vol. 2, 84-90
Open AccessA Roadmap Towards Standards for Neurally Controlled End Effectors
The control and manipulation of various types of end effectors such as powered exoskeletons, prostheses, and ‘neural’ cursors by brain-machine interface (BMI) systems has been the target of many research projects. A seamless “plug and play” interface between any BMI and end effector is desired, wherein similar user's intent cause similar end effectors to behave identically. This report is based on the outcomes of an IEEE Standards Association Industry Connections working group on End Effectors for Brain-Machine Interfacing that convened to identify and address gaps in the existing standards for BMI-based solutions with a focus on the end-effector component. A roadmap towards standardization of end effectors for BMI systems is discussed by identifying current device standards that are applicable for end effectors. While current standards address basic electrical and mechanical safety, and to some extent, performance requirements, several gaps exist pertaining to unified terminologies, data communication protocols, patient safety and risk mitigation.
- Open Access
- 9 March 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-17
An empirical comparison of neural networks and machine learning algorithms for EEG gait decoding
Previous studies of Brain Computer Interfaces (BCI) based on scalp electroencephalography (EEG) have demonstrated the feasibility of decoding kinematics for lower limb movements during walking. In this computational study, we investigated offline decoding analysis with different models and conditions to assess how they influence the performance and stability of the decoder. Specifically, we conducted three computational decoding experiments that investigated decoding accuracy: (1) based on delta band time-domain features, (2) when downsampling data, (3) of different frequency band features. In each experiment, eight different decoder algorithms were compared including the current state-of-the-art. Different tap sizes (sample window sizes) were also evaluated for a real-time applicability assessment. A feature of importance analysis was conducted to ascertain which features were most relevant for decoding; moreover, the stability to perturbations was assessed to quantify the robustness of the methods. Results indicated that generally the Gated Recurrent Unit (GRU) and Quasi Recurrent Neural Network (QRNN) outperformed other methods in terms of decoding accuracy and stability. Previous state-of-the-art Unscented Kalman Filter (UKF) still outperformed other decoders when using smaller tap sizes, with fast convergence in performance, but occurred at a cost to noise vulnerability. Downsampling and the inclusion of other frequency band features yielded overall improvement in performance. The results suggest that neural network-based decoders with downsampling or a wide range of frequency band features could not only improve decoder performance but also robustness with applications for stable use of BCIs.
- 9 March 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-17
Open AccessAn empirical comparison of neural networks and machine learning algorithms for EEG gait decoding
Previous studies of Brain Computer Interfaces (BCI) based on scalp electroencephalography (EEG) have demonstrated the feasibility of decoding kinematics for lower limb movements during walking. In this computational study, we investigated offline decoding analysis with different models and conditions to assess how they influence the performance and stability of the decoder. Specifically, we conducted three computational decoding experiments that investigated decoding accuracy: (1) based on delta band time-domain features, (2) when downsampling data, (3) of different frequency band features. In each experiment, eight different decoder algorithms were compared including the current state-of-the-art. Different tap sizes (sample window sizes) were also evaluated for a real-time applicability assessment. A feature of importance analysis was conducted to ascertain which features were most relevant for decoding; moreover, the stability to perturbations was assessed to quantify the robustness of the methods. Results indicated that generally the Gated Recurrent Unit (GRU) and Quasi Recurrent Neural Network (QRNN) outperformed other methods in terms of decoding accuracy and stability. Previous state-of-the-art Unscented Kalman Filter (UKF) still outperformed other decoders when using smaller tap sizes, with fast convergence in performance, but occurred at a cost to noise vulnerability. Downsampling and the inclusion of other frequency band features yielded overall improvement in performance. The results suggest that neural network-based decoders with downsampling or a wide range of frequency band features could not only improve decoder performance but also robustness with applications for stable use of BCIs.
- Top Cited PapersOpen Access
- 9 April 2019
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 16 (3) , 031001
Deep learning for electroencephalogram (EEG) classification tasks: a review
Electroencephalography (EEG) analysis has been an important tool in neuroscience with applications in neuroscience, neural engineering (e.g. Brain-computer interfaces, BCI's), and even commercial applications. Many of the analytical tools used in EEG studies have used machine learning to uncover relevant information for neural classification and neuroimaging. Recently, the availability of large EEG data sets and advances in machine learning have both led to the deployment of deep learning architectures, especially in the analysis of EEG signals and in understanding the information it may contain for brain functionality. The robust automatic classification of these signals is an important step towards making the use of EEG more practical in many applications and less reliant on trained professionals. Towards this goal, a systematic review of the literature on deep learning applications to EEG classification was performed to address the following critical questions: (1) Which EEG classification tasks have been explored with deep learning? (2) What input formulations have been used for training the deep networks? (3) Are there specific deep learning network structures suitable for specific types of tasks? A systematic literature review of EEG classification using deep learning was performed on Web of Science and PubMed databases, resulting in 90 identified studies. Those studies were analyzed based on type of task, EEG preprocessing methods, input type, and deep learning architecture. For EEG classification tasks, convolutional neural networks, recurrent neural networks, deep belief networks outperform stacked auto-encoders and multi-layer perceptron neural networks in classification accuracy. The tasks that used deep learning fell into five general groups: emotion recognition, motor imagery, mental workload, seizure detection, event related potential detection, and sleep scoring. For each type of task, we describe the specific input formulation, major characteristics, and end classifier recommendations found through this review. This review summarizes the current practices and performance outcomes in the use of deep learning for EEG classification. Practical suggestions on the selection of many hyperparameters are provided in the hope that they will promote or guide the deployment of deep learning to EEG datasets in future research.
- 9 April 2019
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 16 (3) , 031001
Top Cited PapersOpen AccessDeep learning for electroencephalogram (EEG) classification tasks: a review
Electroencephalography (EEG) analysis has been an important tool in neuroscience with applications in neuroscience, neural engineering (e.g. Brain-computer interfaces, BCI's), and even commercial applications. Many of the analytical tools used in EEG studies have used machine learning to uncover relevant information for neural classification and neuroimaging. Recently, the availability of large EEG data sets and advances in machine learning have both led to the deployment of deep learning architectures, especially in the analysis of EEG signals and in understanding the information it may contain for brain functionality. The robust automatic classification of these signals is an important step towards making the use of EEG more practical in many applications and less reliant on trained professionals. Towards this goal, a systematic review of the literature on deep learning applications to EEG classification was performed to address the following critical questions: (1) Which EEG classification tasks have been explored with deep learning? (2) What input formulations have been used for training the deep networks? (3) Are there specific deep learning network structures suitable for specific types of tasks? A systematic literature review of EEG classification using deep learning was performed on Web of Science and PubMed databases, resulting in 90 identified studies. Those studies were analyzed based on type of task, EEG preprocessing methods, input type, and deep learning architecture. For EEG classification tasks, convolutional neural networks, recurrent neural networks, deep belief networks outperform stacked auto-encoders and multi-layer perceptron neural networks in classification accuracy. The tasks that used deep learning fell into five general groups: emotion recognition, motor imagery, mental workload, seizure detection, event related potential detection, and sleep scoring. For each type of task, we describe the specific input formulation, major characteristics, and end classifier recommendations found through this review. This review summarizes the current practices and performance outcomes in the use of deep learning for EEG classification. Practical suggestions on the selection of many hyperparameters are provided in the hope that they will promote or guide the deployment of deep learning to EEG datasets in future research.
- Open Access
- 24 April 2018
- Published by Springer Nature in Scientific Data
- Vol. 5 (1) , 180074
A mobile brain-body imaging dataset recorded during treadmill walking with a brain-computer interface
We present a mobile brain-body imaging (MoBI) dataset acquired during treadmill walking in a brain-computer interface (BCI) task. The data were collected from eight healthy subjects, each having three identical trials. Each trial consisted of three conditions: standing, treadmill walking, and treadmill walking with a closed-loop BCI. During the BCI condition, subjects used their brain activity to control a virtual avatar on a screen to walk in real-time. Robust procedures were designed to record lower limb joint angles (bilateral hip, knee, and ankle) using goniometers synchronized with 60-channel scalp electroencephalography (EEG). Additionally, electrooculogram (EOG), EEG electrodes impedance, and digitized EEG channel locations were acquired to aid artifact removal and EEG dipole-source localization. This dataset is unique in that it is the first published MoBI dataset recorded during walking. It is useful in addressing several important open research questions, such as how EEG is coupled with gait cycle during closed-loop BCI, how BCI influences neural activity during walking, and how a BCI decoder may be optimized.
- 24 April 2018
- Published by Springer Nature in Scientific Data
- Vol. 5 (1) , 180074
Open AccessA mobile brain-body imaging dataset recorded during treadmill walking with a brain-computer interface
We present a mobile brain-body imaging (MoBI) dataset acquired during treadmill walking in a brain-computer interface (BCI) task. The data were collected from eight healthy subjects, each having three identical trials. Each trial consisted of three conditions: standing, treadmill walking, and treadmill walking with a closed-loop BCI. During the BCI condition, subjects used their brain activity to control a virtual avatar on a screen to walk in real-time. Robust procedures were designed to record lower limb joint angles (bilateral hip, knee, and ankle) using goniometers synchronized with 60-channel scalp electroencephalography (EEG). Additionally, electrooculogram (EOG), EEG electrodes impedance, and digitized EEG channel locations were acquired to aid artifact removal and EEG dipole-source localization. This dataset is unique in that it is the first published MoBI dataset recorded during walking. It is useful in addressing several important open research questions, such as how EEG is coupled with gait cycle during closed-loop BCI, how BCI influences neural activity during walking, and how a BCI decoder may be optimized.
- Top Cited PapersOpen Access
- 14 February 2018
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 15 (2) , 021004
Brain–machine interfaces for controlling lower-limb powered robotic systems
Lower-limb, powered robotics systems such as exoskeletons and orthoses have emerged as novel robotic interventions to assist or rehabilitate people with walking disabilities. These devices are generally controlled by certain physical maneuvers, for example pressing buttons or shifting body weight. Although effective, these control schemes are not what humans naturally use. The usability and clinical relevance of these robotics systems could be further enhanced by brain-machine interfaces (BMIs). A number of preliminary studies have been published on this topic, but a systematic understanding of the experimental design, tasks, and performance of BMI-exoskeleton systems for restoration of gait is lacking. To address this gap, we applied standard systematic review methodology for a literature search in PubMed and EMBASE databases and identified 11 studies involving BMI-robotics systems. The devices, user population, input and output of the BMIs and robot systems respectively, neural features, decoders, denoising techniques, and system performance were reviewed and compared. Results showed BMIs classifying walk versus stand tasks are the most common. The results also indicate that electroencephalography (EEG) is the only recording method for humans. Performance was not clearly presented in most of the studies. Several challenges were summarized, including EEG denoising, safety, responsiveness and others. We conclude that lower-body powered exoskeletons with automated gait intention detection based on BMIs open new possibilities in the assistance and rehabilitation fields, although the current performance, clinical benefits and several key challenging issues indicate that additional research and development is required to deploy these systems in the clinic and at home. Moreover, rigorous EEG denoising techniques, suitable performance metrics, consistent trial reporting, and more clinical trials are needed to advance the field.
- 14 February 2018
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 15 (2) , 021004
Top Cited PapersOpen AccessBrain–machine interfaces for controlling lower-limb powered robotic systems
Lower-limb, powered robotics systems such as exoskeletons and orthoses have emerged as novel robotic interventions to assist or rehabilitate people with walking disabilities. These devices are generally controlled by certain physical maneuvers, for example pressing buttons or shifting body weight. Although effective, these control schemes are not what humans naturally use. The usability and clinical relevance of these robotics systems could be further enhanced by brain-machine interfaces (BMIs). A number of preliminary studies have been published on this topic, but a systematic understanding of the experimental design, tasks, and performance of BMI-exoskeleton systems for restoration of gait is lacking. To address this gap, we applied standard systematic review methodology for a literature search in PubMed and EMBASE databases and identified 11 studies involving BMI-robotics systems. The devices, user population, input and output of the BMIs and robot systems respectively, neural features, decoders, denoising techniques, and system performance were reviewed and compared. Results showed BMIs classifying walk versus stand tasks are the most common. The results also indicate that electroencephalography (EEG) is the only recording method for humans. Performance was not clearly presented in most of the studies. Several challenges were summarized, including EEG denoising, safety, responsiveness and others. We conclude that lower-body powered exoskeletons with automated gait intention detection based on BMIs open new possibilities in the assistance and rehabilitation fields, although the current performance, clinical benefits and several key challenging issues indicate that additional research and development is required to deploy these systems in the clinic and at home. Moreover, rigorous EEG denoising techniques, suitable performance metrics, consistent trial reporting, and more clinical trials are needed to advance the field.
- 1 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Risk and adverse events related to lower-limb exoskeletons
Since the marketing clearance from the U.S. Food and Drug Administration (FDA), powered lower-limb exoskeletons have been proposed as a promising tool in gait assistance and rehabilitation. However, previous studies often overlooked the potential risk and adverse events related to the device. Without a clear understanding and comprehensive knowledge of adverse events and the risks users face, it is difficult to evaluate the risk-to-benefit ratio of powered exoskeletons. We reviewed all publically available exoskeleton-related adverse events, and compared the result to the risks that were identified by the FDA. Results showed that bone fracture is a serious risk that was not considered in previous literatures. Additionally, skin and soft tissue damage is common across subjects, studies, and devices. It was often treated as an incidental minor event and overlooked. We encourage more effort at keeping the safety of exoskeleton users in future studies.
- 1 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Risk and adverse events related to lower-limb exoskeletons
Since the marketing clearance from the U.S. Food and Drug Administration (FDA), powered lower-limb exoskeletons have been proposed as a promising tool in gait assistance and rehabilitation. However, previous studies often overlooked the potential risk and adverse events related to the device. Without a clear understanding and comprehensive knowledge of adverse events and the risks users face, it is difficult to evaluate the risk-to-benefit ratio of powered exoskeletons. We reviewed all publically available exoskeleton-related adverse events, and compared the result to the risks that were identified by the FDA. Results showed that bone fracture is a serious risk that was not considered in previous literatures. Additionally, skin and soft tissue damage is common across subjects, studies, and devices. It was often treated as an incidental minor event and overlooked. We encourage more effort at keeping the safety of exoskeleton users in future studies.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 3054-3057
EEG-based brain-computer interface to a virtual walking avatar engages cortical adaptation
Recent advances in brain-computer interface (BCI) technologies have shown the feasibility of neural decoding for both users' gait intent and continuous kinematics. However, the cortical adaptation and the dynamics of cortical involvement in human upright walking with a closed-loop BCI in virtual environment (VE) have yet to be demonstrated. To address explore this possibility, we designed a closed-loop BCI to allow users to control a virtual avatar to walk using their encephalography (EEG). Delta band EEG (0.1-3 Hz) was used as the main feature in prediction. Our results demonstrate the feasibility of using a closed-loop BCI to learn to control a walking avatar. The average decoding accuracies (Pearson's r values) across all subjects increased from (Hip: 0.18 ± 0.31; Knee: 0.23 ± 0.33; Ankle: 0.14 ± 0.22) on Day 1 to (Hip: 0.40 ± 0.24; Knee: 0.55 ± 0.20; Ankle: 0.29 ± 0.22) on Day 8. Source localization revealed significant differences in cortical network activity between walking with and without closed-loop BCI control of the virtual avatar. This current study demonstrates the feasibility of using a closed-loop EEG-based BCI-VR to trigger cortical adaptation, promoting cortical involvement, and monitoring cortical activity from non-invasive EEG. Our system may be relevant for neurological gait rehabilitation as a clinical tool for post-stroke physical training and clinical assessment.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 3054-3057
EEG-based brain-computer interface to a virtual walking avatar engages cortical adaptation
Recent advances in brain-computer interface (BCI) technologies have shown the feasibility of neural decoding for both users' gait intent and continuous kinematics. However, the cortical adaptation and the dynamics of cortical involvement in human upright walking with a closed-loop BCI in virtual environment (VE) have yet to be demonstrated. To address explore this possibility, we designed a closed-loop BCI to allow users to control a virtual avatar to walk using their encephalography (EEG). Delta band EEG (0.1-3 Hz) was used as the main feature in prediction. Our results demonstrate the feasibility of using a closed-loop BCI to learn to control a walking avatar. The average decoding accuracies (Pearson's r values) across all subjects increased from (Hip: 0.18 ± 0.31; Knee: 0.23 ± 0.33; Ankle: 0.14 ± 0.22) on Day 1 to (Hip: 0.40 ± 0.24; Knee: 0.55 ± 0.20; Ankle: 0.29 ± 0.22) on Day 8. Source localization revealed significant differences in cortical network activity between walking with and without closed-loop BCI control of the virtual avatar. This current study demonstrates the feasibility of using a closed-loop EEG-based BCI-VR to trigger cortical adaptation, promoting cortical involvement, and monitoring cortical activity from non-invasive EEG. Our system may be relevant for neurological gait rehabilitation as a clinical tool for post-stroke physical training and clinical assessment.
- Open Access
- 21 August 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1-12
Real-time EEG-based brain-computer interface to a virtual avatar enhances cortical involvement in human treadmill walking
Recent advances in non-invasive brain-computer interface (BCI) technologies have shown the feasibility of neural decoding for both users’ gait intent and continuous kinematics. However, the dynamics of cortical involvement in human upright walking with a closed-loop BCI has not been investigated. This study aims to investigate the changes of cortical involvement in human treadmill walking with and without BCI control of a walking avatar. Source localization revealed significant differences in cortical network activity between walking with and without closed-loop BCI control. Our results showed sustained α/µ suppression in the Posterior Parietal Cortex and Inferior Parietal Lobe, indicating increases of cortical involvement during walking with BCI control. We also observed significant increased activity of the Anterior Cingulate Cortex (ACC) in the low frequency band suggesting the presence of a cortical network involved in error monitoring and motor learning. Additionally, the presence of low γ modulations in the ACC and Superior Temporal Gyrus may associate with increases of voluntary control of human gait. This work is a further step toward the development of a novel training paradigm for improving the efficacy of rehabilitation in a top-down approach.
- 21 August 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1-12
Open AccessReal-time EEG-based brain-computer interface to a virtual avatar enhances cortical involvement in human treadmill walking
Recent advances in non-invasive brain-computer interface (BCI) technologies have shown the feasibility of neural decoding for both users’ gait intent and continuous kinematics. However, the dynamics of cortical involvement in human upright walking with a closed-loop BCI has not been investigated. This study aims to investigate the changes of cortical involvement in human treadmill walking with and without BCI control of a walking avatar. Source localization revealed significant differences in cortical network activity between walking with and without closed-loop BCI control. Our results showed sustained α/µ suppression in the Posterior Parietal Cortex and Inferior Parietal Lobe, indicating increases of cortical involvement during walking with BCI control. We also observed significant increased activity of the Anterior Cingulate Cortex (ACC) in the low frequency band suggesting the presence of a cortical network involved in error monitoring and motor learning. Additionally, the presence of low γ modulations in the ACC and Superior Temporal Gyrus may associate with increases of voluntary control of human gait. This work is a further step toward the development of a novel training paradigm for improving the efficacy of rehabilitation in a top-down approach.
- Open Access
- 20 June 2017
- Published by Frontiers Media SA in Frontiers in Human Neuroscience
- Vol. 11, 320
Multi-Trial Gait Adaptation of Healthy Individuals during Visual Kinematic Perturbations
Optimizing rehabilitation strategies requires understanding the effects of contextual cues on adaptation learning. Prior studies have examined these effects on the specificity of split-belt walking adaptation, showing that contextual visual cues can be manipulated to modulate the magnitude, transfer, and washout of split-belt-induced learning in humans. Specifically, manipulating the availability of vision during training or testing phases of learning resulted in differences in adaptive mechanisms for temporal and spatial features of walking. However, multi-trial locomotor training has been rarely explored when using visual kinematic gait perturbations. In this study, we investigated multi-trial locomotor adaptation in ten healthy individuals while applying visual kinematic perturbations. Subjects were instructed to control a moving cursor, which represented the position of their heel, to follow a prescribed heel path profile displayed on a monitor. The perturbations were introduced by scaling all of the lower limb joint angles by a factor of 0.7 (i.e., a gain change), resulting in visual feedback errors between subjects’ heel trajectories and the prescribed path profiles. Our findings suggest that, with practice, the subjects learned, albeit with different strategies, to reduce the tracking errors and showed faster response time in later trials. Moreover, the gait symmetry indices, in both the spatial and temporal domains, changed significantly during gait adaptation (P < 0.001). After-effects were present in the temporal gait symmetry index when the visual perturbations were removed in the post-exposure period (P < 0.001), suggesting adaptation learning. These findings may have implications for developing novel gait rehabilitation interventions.
- 20 June 2017
- Published by Frontiers Media SA in Frontiers in Human Neuroscience
- Vol. 11, 320
Open AccessMulti-Trial Gait Adaptation of Healthy Individuals during Visual Kinematic Perturbations
Optimizing rehabilitation strategies requires understanding the effects of contextual cues on adaptation learning. Prior studies have examined these effects on the specificity of split-belt walking adaptation, showing that contextual visual cues can be manipulated to modulate the magnitude, transfer, and washout of split-belt-induced learning in humans. Specifically, manipulating the availability of vision during training or testing phases of learning resulted in differences in adaptive mechanisms for temporal and spatial features of walking. However, multi-trial locomotor training has been rarely explored when using visual kinematic gait perturbations. In this study, we investigated multi-trial locomotor adaptation in ten healthy individuals while applying visual kinematic perturbations. Subjects were instructed to control a moving cursor, which represented the position of their heel, to follow a prescribed heel path profile displayed on a monitor. The perturbations were introduced by scaling all of the lower limb joint angles by a factor of 0.7 (i.e., a gain change), resulting in visual feedback errors between subjects’ heel trajectories and the prescribed path profiles. Our findings suggest that, with practice, the subjects learned, albeit with different strategies, to reduce the tracking errors and showed faster response time in later trials. Moreover, the gait symmetry indices, in both the spatial and temporal domains, changed significantly during gait adaptation (P < 0.001). After-effects were present in the temporal gait symmetry index when the visual perturbations were removed in the post-exposure period (P < 0.001), suggesting adaptation learning. These findings may have implications for developing novel gait rehabilitation interventions.