Miguel Goncalves
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Miguel Goncalves has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
Heinrich Iro
University of Erlangen-Nuremberg, FAU Medical School, Department of Otorhinolaryngology, Head and Neck Surgery, Erlangen, Germany
6 shared publicationsKonstantinos Mantsopoulos
University of Erlangen-Nuremberg, FAU Medical School, Department of Otorhinolaryngology, Head and Neck Surgery, Erlangen, Germany
5 shared publicationsMichael Koch
University of Erlangen-Nuremberg, FAU Medical School, Department of Otorhinolaryngology, Head and Neck Surgery, Erlangen, Germany
5 shared publications- Konstantinos Mantsopoulos
Department of Otorhinolaryngology and Head and Neck Surgery, University of Erlangen–Nuremberg, 91054 Erlangen, Germany
3 shared publications Mirco Schapher
Department of Otorhinolaryngology and Head and Neck Surgery, University of Erlangen-Nuremberg, Erlangen, Germany
3 shared publicationsH. Iro
Department of Otorhinolaryngology, Head and Neck Surgery, Friedrich-Alexander-Universität Erlangen-Nürnberg, University Hospital, Erlangen, Germany
2 shared publications
Latest Publications
- 1 August 2020
- Published by Elsevier in Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology
- Vol. 130 (2) , e24-e28
Papillary stenosis of the submandibular gland caused by dental prostheses
- 1 August 2020
- Published by Elsevier in Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology
- Vol. 130 (2) , e24-e28
Papillary stenosis of the submandibular gland caused by dental prostheses
- Open Access
- 1 May 2020
- Published by Georg Thieme Verlag KG
- Vol. 99 (S 02)
Wertigkeit der Sonographie bei Sialodochitis und Gangstenosen der Glandula parotidea
Einleitung Gangstenosen (GS) und Sialodochitis (SD) sind die wichtigsten nicht steinbedingten obstruktiven Sialopathien, davon sind ca. 75 % in der Gl. Parotis (GP) lokalisiert. Diese derzeit meist mittels Sialographie und MR-Sialographie diagnostiziert. Ziel Evaluierung des diagnostischen Wertes des Ultraschalls (US) bei SD und GS. Methoden Retrospektive Evaluierung der Befunde aller Patienten, welche sich von 2011-2017 wegen V.a. obstruktive Sialopathie der GP vorgestellt haben. Patienten mit Sialolithiasis wurden ausgeschlossen. 525 Patienten (691 GP) wurden untersucht. Alle Patienten erhielten einen US und anschließend eine SE. US-Parameter waren die Parenchym-Textur (PT) und der Gangdurchmesser (GDM). Diese wurden mit den Befunden nach SE als diagnostischer Referenzstandard verglichen. Ergebnisse Die SE zeigte eine SD in 223 (32,9 %), eine GS in 315 (45,6 %, davon 21.6 % mit Ganganomalien assoziiert) und ein unauffälliger Befund in 149 (21,6 %) der Fälle. GP mit unauffälligen Befunden zeigten GDM von 0.3 mm (0-2.7mm) und eine echoreiche PT in 98.7 %. Im Vergleich dazu zeigte eine SD einen größeren GDM (0.7 mm, 0-4.3mm, p<0.001) und ein echoarme PT in 78.0 % der Fälle (p<0.001). Bei GS zeigte sich in 52.6 % eine echoarme PT und ein GDM von 4.1mm (0-19mm), bei Assoziation mit Ganganomalien war die PT jedoch in 85.3 % echoreich, der GDM betrug 8.9mm (4.0-19mm). Ab einem GDM von 2,7mm im US lag eine GS in 96.1 % der Fälle vor (AUC 0.886, p<0.001). Ein GDM von 5.2 mm identifiziert eine GS mit Ganganomalie mit 92.6 % Sensitivität und 97,0 % Spezifität (AUC: 0.986, p<0.001). Schlussfolgerungen Die Daten deuten an, dass der US als alleinige Bildgebung bei V. a. auf SD oder GS der GP in den meisten Fällen eine valide Diagnose ermöglichen und einen Beitrag zur Therapie-Planung leisten kann. Poster-PDF A-1135.PDF Publication Date: 10 June 2020 (online) © . © Georg Thieme Verlag KG Stuttgart · New York
- 1 May 2020
- Published by Georg Thieme Verlag KG
- Vol. 99 (S 02)
Open AccessWertigkeit der Sonographie bei Sialodochitis und Gangstenosen der Glandula parotidea
Einleitung Gangstenosen (GS) und Sialodochitis (SD) sind die wichtigsten nicht steinbedingten obstruktiven Sialopathien, davon sind ca. 75 % in der Gl. Parotis (GP) lokalisiert. Diese derzeit meist mittels Sialographie und MR-Sialographie diagnostiziert. Ziel Evaluierung des diagnostischen Wertes des Ultraschalls (US) bei SD und GS. Methoden Retrospektive Evaluierung der Befunde aller Patienten, welche sich von 2011-2017 wegen V.a. obstruktive Sialopathie der GP vorgestellt haben. Patienten mit Sialolithiasis wurden ausgeschlossen. 525 Patienten (691 GP) wurden untersucht. Alle Patienten erhielten einen US und anschließend eine SE. US-Parameter waren die Parenchym-Textur (PT) und der Gangdurchmesser (GDM). Diese wurden mit den Befunden nach SE als diagnostischer Referenzstandard verglichen. Ergebnisse Die SE zeigte eine SD in 223 (32,9 %), eine GS in 315 (45,6 %, davon 21.6 % mit Ganganomalien assoziiert) und ein unauffälliger Befund in 149 (21,6 %) der Fälle. GP mit unauffälligen Befunden zeigten GDM von 0.3 mm (0-2.7mm) und eine echoreiche PT in 98.7 %. Im Vergleich dazu zeigte eine SD einen größeren GDM (0.7 mm, 0-4.3mm, p<0.001) und ein echoarme PT in 78.0 % der Fälle (p<0.001). Bei GS zeigte sich in 52.6 % eine echoarme PT und ein GDM von 4.1mm (0-19mm), bei Assoziation mit Ganganomalien war die PT jedoch in 85.3 % echoreich, der GDM betrug 8.9mm (4.0-19mm). Ab einem GDM von 2,7mm im US lag eine GS in 96.1 % der Fälle vor (AUC 0.886, p<0.001). Ein GDM von 5.2 mm identifiziert eine GS mit Ganganomalie mit 92.6 % Sensitivität und 97,0 % Spezifität (AUC: 0.986, p<0.001). Schlussfolgerungen Die Daten deuten an, dass der US als alleinige Bildgebung bei V. a. auf SD oder GS der GP in den meisten Fällen eine valide Diagnose ermöglichen und einen Beitrag zur Therapie-Planung leisten kann. Poster-PDF A-1135.PDF Publication Date: 10 June 2020 (online) © . © Georg Thieme Verlag KG Stuttgart · New York
- Open Access
- 1 December 2019
- Published by Pacini Editore in Acta Otorhinolaryngologica Italica
- Vol. 39 (6) , 389-395
Probe-based confocal laser endomicroscopy in detecting malignant lesions of vocal folds
Probe-based confocal laser endomicroscopy (CLE) is an innovative technique for real-time, non-invasive analysis of the surface epithelium.While being successfully used for diagnosis by experts, this method has not yet been established in clinical routine, partly due to the lack of standards and criteria for classifying various lesions. Our aim was to determine the diagnostic value and inter-rater reliability of CLE in detecting malignant lesions of the vocal cords. 58 video sequences were extracted from the probe-based CLE (GastroFlex probe with a Cellvizio® laser system) examinations of 3 patients with squamous cell carcinomas and 4 patients with benign alterations of the vocal folds. Two ENT surgeons, who were blinded to the histological result, were asked to identify the sequences representing a carcinoma. We showed an accuracy, sensitivity, specificity, PPV and NPV of 91.38-96.55%, 100%, 87.8-95.2%, 77.27-89.47% and 100%, respectively, with an inter-rater reliability of k = 0.89 (“almost perfect agreement”). Probe-based CLE is a promising method for diagnosis and assessment of vocal fold lesions in vivo. Our results suggest that, with adequate training, the diagnostic value of this technique can be improved and potentially provide important information during oncological surgery.
- 1 December 2019
- Published by Pacini Editore in Acta Otorhinolaryngologica Italica
- Vol. 39 (6) , 389-395
Open AccessProbe-based confocal laser endomicroscopy in detecting malignant lesions of vocal folds
Probe-based confocal laser endomicroscopy (CLE) is an innovative technique for real-time, non-invasive analysis of the surface epithelium.While being successfully used for diagnosis by experts, this method has not yet been established in clinical routine, partly due to the lack of standards and criteria for classifying various lesions. Our aim was to determine the diagnostic value and inter-rater reliability of CLE in detecting malignant lesions of the vocal cords. 58 video sequences were extracted from the probe-based CLE (GastroFlex probe with a Cellvizio® laser system) examinations of 3 patients with squamous cell carcinomas and 4 patients with benign alterations of the vocal folds. Two ENT surgeons, who were blinded to the histological result, were asked to identify the sequences representing a carcinoma. We showed an accuracy, sensitivity, specificity, PPV and NPV of 91.38-96.55%, 100%, 87.8-95.2%, 77.27-89.47% and 100%, respectively, with an inter-rater reliability of k = 0.89 (“almost perfect agreement”). Probe-based CLE is a promising method for diagnosis and assessment of vocal fold lesions in vivo. Our results suggest that, with adequate training, the diagnostic value of this technique can be improved and potentially provide important information during oncological surgery.
- 1 September 2019
- Published by Elsevier in Journal of Cranio-Maxillofacial Surgery
- Vol. 47 (9) , 1356-1362
Parotid pleomorphic adenomas: Factors influencing surgical techniques, morbidity, and long-term outcome relative to the new ESGS classification in a retrospective study
- 1 September 2019
- Published by Elsevier in Journal of Cranio-Maxillofacial Surgery
- Vol. 47 (9) , 1356-1362
Parotid pleomorphic adenomas: Factors influencing surgical techniques, morbidity, and long-term outcome relative to the new ESGS classification in a retrospective study
- 22 August 2019
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 40 (05) , 658
Response to Letter to the editor: Interrater Reliability of Ultrasound in the Diagnosis of Sialolithiasis: Methodological Issues. Interrater Reliability of Ultrasound: Methodological Issues
Thank you for your constructive comments on our manuscript. In our study [1], we evaluated 100 consecutive patients with signs of obstructive sialadenopathy. The patients all underwent ultrasound examinations in a standardized manner conducted by one specialist (E1) with extensive experience in the management of salivary gland disorders and proficiency in head and neck ultrasonography. The video recordings were sent to six colleagues (E2–E7) with comparable experience without providing any further information about the patients’ medical history and physical examination. We used Cohen’s kappa coefficient (κ) to evaluate the interrater agreement between the different pairs of examiners. Using Cohen’s kappa test for the observer pairs E2–E7, we obtained an overall agreement of k = 0.751, ranging between 0.663 and 0.878. For E1–E7 we obtained an overall agreement of k = 0.765, ranging between 0.663–0.878. According to Landis and Koch [2], this is substantial to almost perfect agreement between the different pairs. The percentage agreement as well as the diagnostic metrics for every examiner was information that was additionally provided. The author of the letter to the editor criticized the absence of the Fleiss-Kappa test in our publication and recommended applying it. This test is used to test the overall interobserver agreement between more than two observers at the same time. We did not consider including this in our original publication, because the values obtained after applying Cohen’s Kappa test were above the relevant threshold of 0.6 (minimum 0.663) in all calculations performed, but we would like to present these results now in our answer letter. Here are our results from the Fleiss-kappa test for the overall agreement [3] [4]: We obtained a Fleiss kappa value of 0.751 for E2–E7 and 0.764 for E1–E7. When these results are compared with those presented in our original publication, no differences with respect to the results and conclusions could be noted. In conclusion, we confirm the high levels of interrater agreement for Cohen’s and Fleiss Kappa, even in the absence of additional clinical patient information, thus further underscoring the importance of ultrasound as the examination of first choice in sialolithiasis. Sincerely, Miguel Goncalves and Michael Koch
- 22 August 2019
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 40 (05) , 658
Response to Letter to the editor: Interrater Reliability of Ultrasound in the Diagnosis of Sialolithiasis: Methodological Issues. Interrater Reliability of Ultrasound: Methodological Issues
Thank you for your constructive comments on our manuscript. In our study [1], we evaluated 100 consecutive patients with signs of obstructive sialadenopathy. The patients all underwent ultrasound examinations in a standardized manner conducted by one specialist (E1) with extensive experience in the management of salivary gland disorders and proficiency in head and neck ultrasonography. The video recordings were sent to six colleagues (E2–E7) with comparable experience without providing any further information about the patients’ medical history and physical examination. We used Cohen’s kappa coefficient (κ) to evaluate the interrater agreement between the different pairs of examiners. Using Cohen’s kappa test for the observer pairs E2–E7, we obtained an overall agreement of k = 0.751, ranging between 0.663 and 0.878. For E1–E7 we obtained an overall agreement of k = 0.765, ranging between 0.663–0.878. According to Landis and Koch [2], this is substantial to almost perfect agreement between the different pairs. The percentage agreement as well as the diagnostic metrics for every examiner was information that was additionally provided. The author of the letter to the editor criticized the absence of the Fleiss-Kappa test in our publication and recommended applying it. This test is used to test the overall interobserver agreement between more than two observers at the same time. We did not consider including this in our original publication, because the values obtained after applying Cohen’s Kappa test were above the relevant threshold of 0.6 (minimum 0.663) in all calculations performed, but we would like to present these results now in our answer letter. Here are our results from the Fleiss-kappa test for the overall agreement [3] [4]: We obtained a Fleiss kappa value of 0.751 for E2–E7 and 0.764 for E1–E7. When these results are compared with those presented in our original publication, no differences with respect to the results and conclusions could be noted. In conclusion, we confirm the high levels of interrater agreement for Cohen’s and Fleiss Kappa, even in the absence of additional clinical patient information, thus further underscoring the importance of ultrasound as the examination of first choice in sialolithiasis. Sincerely, Miguel Goncalves and Michael Koch
- 24 March 2019
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 38 (11) , 2935-2943
Ultrasound in the Assessment of Parotid Duct Stenosis
Objectives: Parotid duct stenosis may occur with or without accompanying ductal anomalies, with associated differences in their pathogenesis and management. By identifying the characteristics of a stenosis, ultrasound (US) can assist in tailored management of parotid duct stenosis. The objective of this study was therefore to describe the US characteristics of parotid duct stenoses and to evaluate criteria for whether and in what ways these can be distinguished from each other by using US.Methods: A total of 108 patients who presented with parotid duct stenoses (130 parotid glands) were examined with high‐resolution US between 2014 and 2017. The stenoses were assessed for duct dilatation, location, signs of ductal anomalies (circular encroachments/webs, duct bending/kinking, and presence of a megaduct) and the echogenicity of the gland parenchyma.Results: Ultrasound was able to distinguish between stenoses associated with ductal anomalies and those without anomalies. Webs (82.5% versus 7.8%; P < .001), kinking (75.0% versus 3.3%; P < .001), and a megaduct (87.50% versus 15.63%; P < .001) and a tendency toward normal echogenicity in the gland parenchyma (77.5% versus 25.6%; P < .001) were significantly associated with ductal anomalies. Stenoses associated with ductal anomalies also had significantly larger duct diameters in comparison with those without anomalies (mean ± SD, 9.19 ± 3.65 versus 3.27 ± 2.17 mm; P < .001).Conclusions: This study describes US parameters that allow more detailed characterization of parotid stenoses with or without accompanying ductal anomalies. Differentiating between these at an early stage may be helpful for decision making on the further management in these patients.
- 24 March 2019
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 38 (11) , 2935-2943
Ultrasound in the Assessment of Parotid Duct Stenosis
Objectives: Parotid duct stenosis may occur with or without accompanying ductal anomalies, with associated differences in their pathogenesis and management. By identifying the characteristics of a stenosis, ultrasound (US) can assist in tailored management of parotid duct stenosis. The objective of this study was therefore to describe the US characteristics of parotid duct stenoses and to evaluate criteria for whether and in what ways these can be distinguished from each other by using US.Methods: A total of 108 patients who presented with parotid duct stenoses (130 parotid glands) were examined with high‐resolution US between 2014 and 2017. The stenoses were assessed for duct dilatation, location, signs of ductal anomalies (circular encroachments/webs, duct bending/kinking, and presence of a megaduct) and the echogenicity of the gland parenchyma.Results: Ultrasound was able to distinguish between stenoses associated with ductal anomalies and those without anomalies. Webs (82.5% versus 7.8%; P < .001), kinking (75.0% versus 3.3%; P < .001), and a megaduct (87.50% versus 15.63%; P < .001) and a tendency toward normal echogenicity in the gland parenchyma (77.5% versus 25.6%; P < .001) were significantly associated with ductal anomalies. Stenoses associated with ductal anomalies also had significantly larger duct diameters in comparison with those without anomalies (mean ± SD, 9.19 ± 3.65 versus 3.27 ± 2.17 mm; P < .001).Conclusions: This study describes US parameters that allow more detailed characterization of parotid stenoses with or without accompanying ductal anomalies. Differentiating between these at an early stage may be helpful for decision making on the further management in these patients.
- 7 February 2019
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 40 (04) , 481-487
Interrater Reliability of Ultrasound in the Diagnosis of Sialolithiasis
Purpose The aim of this study was to assess the interrater reliability of ultrasound for diagnosing sialolithiasis. Materials and Methods A total of 100 consecutive patients with signs of obstructive sialadenopathy were evaluated. The patients all underwent ultrasound examinations in a standardized manner conducted by one specialist with extensive experience in the management of salivary gland disorders and proficiency in head and neck ultrasonography. The video recordings were sent to six colleagues with comparable experience without providing any further information about the patients’ medical history and physical examination. Results The overall agreement between the seven observers was substantial, with a κ of 0.765 for the 100 cases and a percentage agreement level of 88.29 ± 3.01 % (range: 83 – 94 %). The range of agreement on this video set for observer pairs varied from substantial to almost perfect agreement (0.663 to 0.878). Among the few false-negative findings (5.4 %), 71.8 % were due to distal sialolithiasis. Two-thirds of the false-positive findings (3.7 %) were due to fibrotic stenosis. Conclusion The study confirmed the diagnostic value of ultrasound in sialolithiasis and demonstrated a very high level of interrater agreement, even in the absence of additional clinical patient information, thus further underscoring the importance of ultrasound as the examination of first choice in sialolithiasis. Ziel Das Ziel dieser Studie war die Beurteilung der Interrater-Reliabilität der Sonografie in der Diagnose der Sialolithiasis. Material und Methoden Insgesamt wurden 100 konsekutive Patienten mit Anzeichen einer obstruktiven Sialadenopathie untersucht. Die Patienten unterzogen sich einer standardisierten sonografischen Untersuchung, die von einem HNO- Arzt mit umfangreicher Erfahrung in der Sonographie und in der Behandlung von Speicheldrüsenerkrankungen durchgeführt wurde. Die Videoaufnahmen wurden an 6 Kollegen mit vergleichbarer Erfahrung gesendet, ohne weitere Informationen über die Krankengeschichte und die körperliche Untersuchung der Patienten zu geben. Ergebnisse Die Gesamtübereinstimmung zwischen den 7 Beobachtern war substanziell, mit einem κ von 0,765 für die 100 Fälle und einem prozentualen Übereinstimmungsgrad von 88,29 ± 3,01 % (Bereich 83 – 94 %). Die Bandbreite der Übereinstimmung in diesem Video-Set für Beobachterpaare variierte von substanziell bis nahezu perfekt (0,663 bis 0,878). Unter den wenigen falsch negativen Befunden (5,4 %) waren 71,8 % auf distale Sialolithiasis zurückzuführen. 2 Drittel der falsch positiven Befunde (3,7 %) waren auf eine fibrotische Stenose zurückzuführen. Schlussfolgerung Die Studie bestätigte den diagnostischen Wert von Ultraschall bei Sialolithiasis und zeigte eine sehr hohe Interrater-Übereinstimmung, auch ohne zusätzliche klinische Patienteninformationen. Dies unterstreicht die Bedeutung von Ultraschall für die Untersuchung der ersten Wahl bei Sialolithiasis. * These authors contributed equally to the article.
- 7 February 2019
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 40 (04) , 481-487
Interrater Reliability of Ultrasound in the Diagnosis of Sialolithiasis
Purpose The aim of this study was to assess the interrater reliability of ultrasound for diagnosing sialolithiasis. Materials and Methods A total of 100 consecutive patients with signs of obstructive sialadenopathy were evaluated. The patients all underwent ultrasound examinations in a standardized manner conducted by one specialist with extensive experience in the management of salivary gland disorders and proficiency in head and neck ultrasonography. The video recordings were sent to six colleagues with comparable experience without providing any further information about the patients’ medical history and physical examination. Results The overall agreement between the seven observers was substantial, with a κ of 0.765 for the 100 cases and a percentage agreement level of 88.29 ± 3.01 % (range: 83 – 94 %). The range of agreement on this video set for observer pairs varied from substantial to almost perfect agreement (0.663 to 0.878). Among the few false-negative findings (5.4 %), 71.8 % were due to distal sialolithiasis. Two-thirds of the false-positive findings (3.7 %) were due to fibrotic stenosis. Conclusion The study confirmed the diagnostic value of ultrasound in sialolithiasis and demonstrated a very high level of interrater agreement, even in the absence of additional clinical patient information, thus further underscoring the importance of ultrasound as the examination of first choice in sialolithiasis. Ziel Das Ziel dieser Studie war die Beurteilung der Interrater-Reliabilität der Sonografie in der Diagnose der Sialolithiasis. Material und Methoden Insgesamt wurden 100 konsekutive Patienten mit Anzeichen einer obstruktiven Sialadenopathie untersucht. Die Patienten unterzogen sich einer standardisierten sonografischen Untersuchung, die von einem HNO- Arzt mit umfangreicher Erfahrung in der Sonographie und in der Behandlung von Speicheldrüsenerkrankungen durchgeführt wurde. Die Videoaufnahmen wurden an 6 Kollegen mit vergleichbarer Erfahrung gesendet, ohne weitere Informationen über die Krankengeschichte und die körperliche Untersuchung der Patienten zu geben. Ergebnisse Die Gesamtübereinstimmung zwischen den 7 Beobachtern war substanziell, mit einem κ von 0,765 für die 100 Fälle und einem prozentualen Übereinstimmungsgrad von 88,29 ± 3,01 % (Bereich 83 – 94 %). Die Bandbreite der Übereinstimmung in diesem Video-Set für Beobachterpaare variierte von substanziell bis nahezu perfekt (0,663 bis 0,878). Unter den wenigen falsch negativen Befunden (5,4 %) waren 71,8 % auf distale Sialolithiasis zurückzuführen. 2 Drittel der falsch positiven Befunde (3,7 %) waren auf eine fibrotische Stenose zurückzuführen. Schlussfolgerung Die Studie bestätigte den diagnostischen Wert von Ultraschall bei Sialolithiasis und zeigte eine sehr hohe Interrater-Übereinstimmung, auch ohne zusätzliche klinische Patienteninformationen. Dies unterstreicht die Bedeutung von Ultraschall für die Untersuchung der ersten Wahl bei Sialolithiasis. * These authors contributed equally to the article.
- Open Access
- 16 October 2017
- Published by Wiley in Laryngoscope Investigative Otolaryngology
- Vol. 2 (6) , 369-372
Long‐term oncologic and functional outcome in pleomorphic adenomas of the submandibular gland
Objectives: The aim of the study was to evaluate the oncologic and functional long‐term outcome after surgical therapy of pleomorphic adenomas of the submandibular gland.Methods: The medical charts of all patients treated for pleomorphic adenomas of the submandibular gland by means of submandibulectomy between 2000 and 2016 were studied retrospectively. Patients who had had revision after external primary surgery, as well as patients with insufficient data were excluded from our study sample.Results: A total of 75 patients formed our study sample (28 men, 47 women, male:female ratio 0.59:1). Their mean age was 48 years (14–78 years). Mean follow‐up was 82 months (12–170 months). No recurrences of a pleomorphic adenoma could be detected in our study cases. Normal facial nerve function (House‐Brackmann grade I) in the direct postoperative phase was shown in 54/75 cases (72%). In the remaining 21/75 cases (28%), mild paresis of the marginal mandibular branch of the facial nerve (House‐Brackmann II) could be detected in the direct postoperative phase. All cases with facial palsy had recovered with normal facial nerve function (House‐Brackmann I) in 3–6 months.Conclusion: Our study was able to show oncologic and consistently acceptable oncologic and functional outcomes after submandibulectomy for pleomorphic adenomas of the submandibular gland.Level of Evidence: 4.
- 16 October 2017
- Published by Wiley in Laryngoscope Investigative Otolaryngology
- Vol. 2 (6) , 369-372
Open AccessLong‐term oncologic and functional outcome in pleomorphic adenomas of the submandibular gland
Objectives: The aim of the study was to evaluate the oncologic and functional long‐term outcome after surgical therapy of pleomorphic adenomas of the submandibular gland.Methods: The medical charts of all patients treated for pleomorphic adenomas of the submandibular gland by means of submandibulectomy between 2000 and 2016 were studied retrospectively. Patients who had had revision after external primary surgery, as well as patients with insufficient data were excluded from our study sample.Results: A total of 75 patients formed our study sample (28 men, 47 women, male:female ratio 0.59:1). Their mean age was 48 years (14–78 years). Mean follow‐up was 82 months (12–170 months). No recurrences of a pleomorphic adenoma could be detected in our study cases. Normal facial nerve function (House‐Brackmann grade I) in the direct postoperative phase was shown in 54/75 cases (72%). In the remaining 21/75 cases (28%), mild paresis of the marginal mandibular branch of the facial nerve (House‐Brackmann II) could be detected in the direct postoperative phase. All cases with facial palsy had recovered with normal facial nerve function (House‐Brackmann I) in 3–6 months.Conclusion: Our study was able to show oncologic and consistently acceptable oncologic and functional outcomes after submandibulectomy for pleomorphic adenomas of the submandibular gland.Level of Evidence: 4.
- 1 September 2017
- Published by Elsevier in British Journal of Oral and Maxillofacial Surgery
- Vol. 55 (7) , 709-713
Extracapsular dissection in the parapharyngeal space: benefits and potential pitfalls
- 1 September 2017
- Published by Elsevier in British Journal of Oral and Maxillofacial Surgery
- Vol. 55 (7) , 709-713
Extracapsular dissection in the parapharyngeal space: benefits and potential pitfalls
- 1 September 2017
- Vol. 21 (18) , 3990-3997
Value of confocal laser endomicroscopy in the diagnosis of vocal cord lesions.
The aim of this study was to assess the reliability and limitations of confocal laser endomicroscopy (CLE) for diagnosing lesions of the vocal cords and differentiating malignant from non-malignant lesions. During microlaryngoscopy, the vocal cords were scanned by probe-based CLE (pCLE: a GastroFlex probe with the Cellvizio® laser system, Mauna Technologies, Paris, France). The video recordings were analyzed and compared with the histological results. Thirty-one representative images were extracted and presented to four medical professionals (blinded examiners) for assessment. The accuracy for the category malignant/nonmalignant ranged between 58.1% and 87.1%. Overall interrater reliability was 0.29. Sensitivity ranged between 45.5 and 100%, specificity between 60.0 and 100%, PPV between 38.5% and 100% and NPV between 66.7 and 100%. CLE is a promising method for the non-invasive diagnosis of vocal cord lesions in vivo, but factors such as small penetration depth, not available contrast media for the nuclei and subjective analyses of the images limit, at the moment, its diagnostic value.
- 1 September 2017
- Vol. 21 (18) , 3990-3997
Value of confocal laser endomicroscopy in the diagnosis of vocal cord lesions.
The aim of this study was to assess the reliability and limitations of confocal laser endomicroscopy (CLE) for diagnosing lesions of the vocal cords and differentiating malignant from non-malignant lesions. During microlaryngoscopy, the vocal cords were scanned by probe-based CLE (pCLE: a GastroFlex probe with the Cellvizio® laser system, Mauna Technologies, Paris, France). The video recordings were analyzed and compared with the histological results. Thirty-one representative images were extracted and presented to four medical professionals (blinded examiners) for assessment. The accuracy for the category malignant/nonmalignant ranged between 58.1% and 87.1%. Overall interrater reliability was 0.29. Sensitivity ranged between 45.5 and 100%, specificity between 60.0 and 100%, PPV between 38.5% and 100% and NPV between 66.7 and 100%. CLE is a promising method for the non-invasive diagnosis of vocal cord lesions in vivo, but factors such as small penetration depth, not available contrast media for the nuclei and subjective analyses of the images limit, at the moment, its diagnostic value.