Fernanda Coutinho
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Fernanda Coutinho has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Jorge Barreiros
Polytechnic University of Coimbra, Rua da Misericórdia, Lagar dos Cortiços, S. Martinho do Bispo, 3045-093 Coimbra, Portugal
8 shared publications - Rui Cortesao
University of Coimbra
6 shared publications - Joao Paulo Ferreira
Polytechnic University of Coimbra, Rua da Misericórdia, Lagar dos Cortiços, S. Martinho do Bispo, 3045-093 Coimbra, Portugal
4 shared publications - Jose Alberto Fonseca
Universidade de Aveiro
4 shared publications - João Durães
Polytechnic University of Coimbra, Rua da Misericórdia, Lagar dos Cortiços, S. Martinho do Bispo, 3045-093 Coimbra, Portugal
3 shared publications - Marco Silva
Coimbra Institute of Engineering, Polytechnic University of Coimbra, 3030-199 Coimbra, Portugal
3 shared publications
Latest Publications
- Open Access
- 25 August 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (17) , 8453
Facial Tracking Algorithms for Medication Intake Verification: A Scoping Review
Background: Medication non-adherence is a major driver of poor therapeutic outcomes, and computer vision methods that observe facial movements offer a non-contact route to verifying oral medication intake. Objective: To map and synthesize the existing literature on computer vision techniques applicable to the monitoring of medication intake, focusing on face tracking methods, oral movement detection and deglutition recognition, and to assess their potential in supporting automatic medication adherence verification systems. Eligibility criteria: Peer-reviewed articles, conference papers, patents, theses and preprints published from 2016 onward, written in English or Portuguese, applying facial landmark tracking or face analysis to ingestion-related movements (mouth opening, hand-to-mouth motion, pill placement, mastication or deglutition); studies confined to object/pill detection without facial analysis, or to general food intake without transferability to medication, were excluded. Sources of evidence: A systematic screening of 362 initial records was conducted across six main electronic databases and repositories: Google Scholar, PubMed, ScienceDirect, arXiv, IEEE Xplore, and Espacenet. Charting methods: Data were charted with a standardized, pilot-tested extraction form capturing bibliographic attributes, dataset type, experimental environment, face tracking approach, tools/models, and target movements; extraction was performed by a single reviewer. Following the screening process, a final selection of 34 relevant studies was included for detailed analysis and mapping. Results: Among the 34 included studies, 14 employ facial landmarks, 11 utilize temporal deep learning models, 6 apply facial action models and 3 rely on hybrid multimodal approaches that combine video analysis, object detection and temporal modeling. Tasks such as detecting mouth opening or tracking pill-to-mouth movement show promising results, while accurately detecting deglutition remains a technical challenge due to high sensitivity and individual variability. Limitations: The majority of the literature relies on private or institutional datasets (31 studies) and operates in controlled laboratory environments (22 studies); only 2 studies evaluated their methods via independent external datasets, which limits the generalization of current solutions to real-world telemonitoring scenarios. Conclusions: The literature indicates the existence of solid technical foundations for developing automated medication intake verification systems. To advance the field toward practical deployment, future research must address the need for more diverse datasets, real-world validation and more robust, adaptable modeling frameworks.
- 25 August 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (17) , 8453
Open AccessFacial Tracking Algorithms for Medication Intake Verification: A Scoping Review
Background: Medication non-adherence is a major driver of poor therapeutic outcomes, and computer vision methods that observe facial movements offer a non-contact route to verifying oral medication intake. Objective: To map and synthesize the existing literature on computer vision techniques applicable to the monitoring of medication intake, focusing on face tracking methods, oral movement detection and deglutition recognition, and to assess their potential in supporting automatic medication adherence verification systems. Eligibility criteria: Peer-reviewed articles, conference papers, patents, theses and preprints published from 2016 onward, written in English or Portuguese, applying facial landmark tracking or face analysis to ingestion-related movements (mouth opening, hand-to-mouth motion, pill placement, mastication or deglutition); studies confined to object/pill detection without facial analysis, or to general food intake without transferability to medication, were excluded. Sources of evidence: A systematic screening of 362 initial records was conducted across six main electronic databases and repositories: Google Scholar, PubMed, ScienceDirect, arXiv, IEEE Xplore, and Espacenet. Charting methods: Data were charted with a standardized, pilot-tested extraction form capturing bibliographic attributes, dataset type, experimental environment, face tracking approach, tools/models, and target movements; extraction was performed by a single reviewer. Following the screening process, a final selection of 34 relevant studies was included for detailed analysis and mapping. Results: Among the 34 included studies, 14 employ facial landmarks, 11 utilize temporal deep learning models, 6 apply facial action models and 3 rely on hybrid multimodal approaches that combine video analysis, object detection and temporal modeling. Tasks such as detecting mouth opening or tracking pill-to-mouth movement show promising results, while accurately detecting deglutition remains a technical challenge due to high sensitivity and individual variability. Limitations: The majority of the literature relies on private or institutional datasets (31 studies) and operates in controlled laboratory environments (22 studies); only 2 studies evaluated their methods via independent external datasets, which limits the generalization of current solutions to real-world telemonitoring scenarios. Conclusions: The literature indicates the existence of solid technical foundations for developing automated medication intake verification systems. To advance the field toward practical deployment, future research must address the need for more diverse datasets, real-world validation and more robust, adaptable modeling frameworks.
- 25 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 165-168
A Feature Survey on Instrumented Cane
Instrumented canes can offer more features than traditional canes. With this in mind, a survey was conducted on the characteristics this walking aid should have from the standpoint of both healthcare professionals and walking cane users. Collecting, analyzing and interpreting this data allowed us to identify the main features and functionalities that should be on an instrumented cane and on a companion smartphone app.
- 25 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 165-168
A Feature Survey on Instrumented Cane
Instrumented canes can offer more features than traditional canes. With this in mind, a survey was conducted on the characteristics this walking aid should have from the standpoint of both healthcare professionals and walking cane users. Collecting, analyzing and interpreting this data allowed us to identify the main features and functionalities that should be on an instrumented cane and on a companion smartphone app.
- 25 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 161-164
Operational and Regulatory Aspects of Sphygmomanometer Use in Healthcare
This paper explores several pertinent aspects of the sphygmomanometer, a Class IIa medical device, used in every healthcare facility for non-invasive blood pressure measurement. The scope of this exploration ranges from the fundamental principles of the device's operation to the regulatory frameworks, best-practice guidelines for its maintenance and calibration, and discusses the relevant regulatory standards and legal guidelines at the national and European levels that apply to this device. The study also includes a survey of the leading manufacturers of sphygmomanometers, highlighting the primary features that distinguish their products. This comparative analysis of manufacturers sheds light on the key technical characteristics and innovations that separate each brand in the market. Furthermore, the paper presents a case study conducted in a medium-sized Portuguese hospital. The primary objectives of this case study were to identify the total number of sphygmomanometers used, determine the average acquisition, maintenance and calibration costs, assess the maintenance and calibration schedules adopted by the hospital, and determine who holds technical responsibility for carrying out these maintenance and calibration procedures. The findings from this case study provide practical insights into device management, budgeting, and accountability within a healthcare setting, illustrating how sphygmomanometer assets are tracked and maintained in real-world conditions.
- 25 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 161-164
Operational and Regulatory Aspects of Sphygmomanometer Use in Healthcare
This paper explores several pertinent aspects of the sphygmomanometer, a Class IIa medical device, used in every healthcare facility for non-invasive blood pressure measurement. The scope of this exploration ranges from the fundamental principles of the device's operation to the regulatory frameworks, best-practice guidelines for its maintenance and calibration, and discusses the relevant regulatory standards and legal guidelines at the national and European levels that apply to this device. The study also includes a survey of the leading manufacturers of sphygmomanometers, highlighting the primary features that distinguish their products. This comparative analysis of manufacturers sheds light on the key technical characteristics and innovations that separate each brand in the market. Furthermore, the paper presents a case study conducted in a medium-sized Portuguese hospital. The primary objectives of this case study were to identify the total number of sphygmomanometers used, determine the average acquisition, maintenance and calibration costs, assess the maintenance and calibration schedules adopted by the hospital, and determine who holds technical responsibility for carrying out these maintenance and calibration procedures. The findings from this case study provide practical insights into device management, budgeting, and accountability within a healthcare setting, illustrating how sphygmomanometer assets are tracked and maintained in real-world conditions.
- Open Access
- 27 June 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (13) , 7235
Integrated Fleet Management of Mobile Robots for Enhancing Industrial Efficiency: A Case Study on Interoperability in Multi-Brand Environments Within the Automotive Sector
This paper presents the development of fleet management software for mobile robots, including AGV and AMR technologies, within the scope of a case study from the GreenAuto project. The system was designed to integrate position and status data from different robots, unifying this information into a single map. To achieve this, a web-based platform was developed to allow the simultaneous, real-time visualization of all robots in operation. However, the main challenge of this research lies in the heterogeneity of the fleet, which comprises robots of different makes and models from various manufacturers, each using distinct data formats. The proposed approach addresses this by facilitating fleet monitoring and management, ensuring a greater efficiency and coordination in the robot movement. The results demonstrate that the platform improves the traceability and operational supervision, promoting the optimized management of mobile robots. It is concluded that the proposed solution contributes to industrial automation by providing an intuitive and centralized interface, enabling future expansions for new functionalities and the integration with other emerging technologies. The proposed system demonstrated efficiency in updating and supervising operations, with an average latency of 120 ms for task status updates and an interface refresh rate of less than 1 s, enabling near real-time supervision and facilitating operational decision-making.
- 27 June 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (13) , 7235
Open AccessIntegrated Fleet Management of Mobile Robots for Enhancing Industrial Efficiency: A Case Study on Interoperability in Multi-Brand Environments Within the Automotive Sector
This paper presents the development of fleet management software for mobile robots, including AGV and AMR technologies, within the scope of a case study from the GreenAuto project. The system was designed to integrate position and status data from different robots, unifying this information into a single map. To achieve this, a web-based platform was developed to allow the simultaneous, real-time visualization of all robots in operation. However, the main challenge of this research lies in the heterogeneity of the fleet, which comprises robots of different makes and models from various manufacturers, each using distinct data formats. The proposed approach addresses this by facilitating fleet monitoring and management, ensuring a greater efficiency and coordination in the robot movement. The results demonstrate that the platform improves the traceability and operational supervision, promoting the optimized management of mobile robots. It is concluded that the proposed solution contributes to industrial automation by providing an intuitive and centralized interface, enabling future expansions for new functionalities and the integration with other emerging technologies. The proposed system demonstrated efficiency in updating and supervising operations, with an average latency of 120 ms for task status updates and an interface refresh rate of less than 1 s, enabling near real-time supervision and facilitating operational decision-making.
- Open Access
- 20 February 2025
- Published by MDPI AG in Automation
- Vol. 6 (1) , 8
Enhancing Nut-Tightening Processes in the Automotive Industry: Integration of 3D Vision Systems with Collaborative Robots
This paper presents a method for position correction in collaborative robots, applied to a case study in an industrial environment. The case study is aligned with the GreenAuto project and aims to optimize industrial processes through the integration of various hardware elements. The case study focuses on tightening a specific number of nuts onto bolts located on a partition plate, referred to as “Cloison”, which is mounted on commercial vans produced by Stellantis, to secure the plate. The main challenge lies in deviations that may occur in the plate during its assembly process, leading to uncertainties in its fastening to the vehicles. To address this and optimize the process, a collaborative robot was integrated with a 3D vision system and a screwdriving system. By using the 3D vision system, it is possible to determine the bolts’ positions and adjust them within the robot’s frame of reference, enabling the screwdriving system to tighten the nuts accurately. Thus, the proposed method aims to integrate these different systems to tighten the nuts effectively, regardless of the deviations that may arise in the plate during assembly.
- 20 February 2025
- Published by MDPI AG in Automation
- Vol. 6 (1) , 8
Open AccessEnhancing Nut-Tightening Processes in the Automotive Industry: Integration of 3D Vision Systems with Collaborative Robots
This paper presents a method for position correction in collaborative robots, applied to a case study in an industrial environment. The case study is aligned with the GreenAuto project and aims to optimize industrial processes through the integration of various hardware elements. The case study focuses on tightening a specific number of nuts onto bolts located on a partition plate, referred to as “Cloison”, which is mounted on commercial vans produced by Stellantis, to secure the plate. The main challenge lies in deviations that may occur in the plate during its assembly process, leading to uncertainties in its fastening to the vehicles. To address this and optimize the process, a collaborative robot was integrated with a 3D vision system and a screwdriving system. By using the 3D vision system, it is possible to determine the bolts’ positions and adjust them within the robot’s frame of reference, enabling the screwdriving system to tighten the nuts accurately. Thus, the proposed method aims to integrate these different systems to tighten the nuts effectively, regardless of the deviations that may arise in the plate during assembly.
- Open Access
- 14 December 2023
- Published by MDPI AG in Preprints.org
Analysis of AGVs Routes Considering Disturbances and Unexpected Events
Automated Guided Vehicles are self-guided vehicles used in manufacturing and warehouses for material transport. They play a vital role in just-in-time material delivery, ensuring smooth production lines. However, disruptions in their fixed routes can lead to efficiency losses. This paper studies unexpected disruptions in mobile robot routes, assessing the costs of rectification using the E* analysis. The study highlights the significant additional cost of such disruptions, underscoring the importance of their consideration in AGV route planning to enhance system resilience.
- 14 December 2023
- Published by MDPI AG in Preprints.org
Open AccessAnalysis of AGVs Routes Considering Disturbances and Unexpected Events
Automated Guided Vehicles are self-guided vehicles used in manufacturing and warehouses for material transport. They play a vital role in just-in-time material delivery, ensuring smooth production lines. However, disruptions in their fixed routes can lead to efficiency losses. This paper studies unexpected disruptions in mobile robot routes, assessing the costs of rectification using the E* analysis. The study highlights the significant additional cost of such disruptions, underscoring the importance of their consideration in AGV route planning to enhance system resilience.
- 22 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 195-198
Hospital Reprocessing Procedures - Challenges and Good Practices
The main purpose of this paper is to discuss the Reprocessing Units for Medical Devices (RUMEDs) of hospitals in order identify procedures and potential points to improve that will benefit the overall quality of service in target hospitals. We also examine key failures associated with this units. It will mainly focus on the mechanical washing and steam sterilization processes because they're the most often used. General considerations on the design of RUMED units, and its impact on the overall quality of the process, are also made.
- 22 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 195-198
Hospital Reprocessing Procedures - Challenges and Good Practices
The main purpose of this paper is to discuss the Reprocessing Units for Medical Devices (RUMEDs) of hospitals in order identify procedures and potential points to improve that will benefit the overall quality of service in target hospitals. We also examine key failures associated with this units. It will mainly focus on the mechanical washing and steam sterilization processes because they're the most often used. General considerations on the design of RUMED units, and its impact on the overall quality of the process, are also made.
- 22 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 179-182
Cardiac Surgery Equipment - Operation Principles and Maintenance Procedures
Cardiac surgery equipment assists healthcare professionals in the surgical treatment of pathologies of the heart and blood vessels. This equipment is considered critical as the patient's life depends on it. Therefore, it is crucial that the equipment manager ensures it is always in the best operating conditions and in compliance with the applicable regulatory requirements (e.g., electrical safety requirements). Three of the most used cardiac surgery devices are the intra-aortic balloon pump, the extracorporeal circulation machine and the heat exchanger. This paper presents a compilation of relevant information about this equipment, including maintenance procedures and enumeration of the most common malfunctions, based on the analysis of maintenance reports covering the lifecycle of these devices.
- 22 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 179-182
Cardiac Surgery Equipment - Operation Principles and Maintenance Procedures
Cardiac surgery equipment assists healthcare professionals in the surgical treatment of pathologies of the heart and blood vessels. This equipment is considered critical as the patient's life depends on it. Therefore, it is crucial that the equipment manager ensures it is always in the best operating conditions and in compliance with the applicable regulatory requirements (e.g., electrical safety requirements). Three of the most used cardiac surgery devices are the intra-aortic balloon pump, the extracorporeal circulation machine and the heat exchanger. This paper presents a compilation of relevant information about this equipment, including maintenance procedures and enumeration of the most common malfunctions, based on the analysis of maintenance reports covering the lifecycle of these devices.
- 22 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 187-190
Instrumented Canes for Parkinson's Disease: a Survey of Commercial and Research Solutions
Instrumented canes have capabilities that allow them to provide functionalities beyond what a traditional cane can offer its user. This study presents a survey of existing instrumented canes, both of commercial and research nature. We identify the major types of features and functionalities offered by these canes, and also focus with particular interest on those offering capabilities aimed at improving the gait of Parkinson's patients, namely the provision of visual, auditory and tactile cues. We find that although special-purpose features dedicated to Parkinson's patients specific needs are commonly experimented with in research contexts, they are usually absent from commercially available solutions, which focus mainly on utility and emergency management features.
- 22 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 187-190
Instrumented Canes for Parkinson's Disease: a Survey of Commercial and Research Solutions
Instrumented canes have capabilities that allow them to provide functionalities beyond what a traditional cane can offer its user. This study presents a survey of existing instrumented canes, both of commercial and research nature. We identify the major types of features and functionalities offered by these canes, and also focus with particular interest on those offering capabilities aimed at improving the gait of Parkinson's patients, namely the provision of visual, auditory and tactile cues. We find that although special-purpose features dedicated to Parkinson's patients specific needs are commonly experimented with in research contexts, they are usually absent from commercially available solutions, which focus mainly on utility and emergency management features.
- 1 January 2023
- Published by Springer Nature
- p. 577-587
Gait Patterns Analysis Using Pressure Plataforms
- 1 January 2023
- Published by Springer Nature
- p. 577-587
Gait Patterns Analysis Using Pressure Plataforms