Yoichi Tamagawa
Yoichi Tamagawa has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
Akira Yamamoto
University of Fukui
1 shared publicationAtsushi Kawamura
University of Fukui
1 shared publication- Daisuke Tanaka
School of Science, Kwansei Gakuin University, 1 Gakuen Uegahara, Sanda, Hyogo 669-1330, Japan
1 shared publication G Ito
Osaka University
1 shared publicationGoro Fujita
University of Fukui
1 shared publicationH Kakubata
Osaka University
1 shared publication
Latest Publications
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Timing Performance of Cherenkov-Radiator-Integrated MCP-PMT
Coincidence time resolution (CTR) of 10 ps is an ultimate goal toward reconstruction-less positron emission tomography (PET). One of the ways to enhance the timing performance of the PET detector is to make use of Cherenkov photons which is promptly emitted on the order of picosecond. A Cherenkov detector composed of a Cherenkov radiator and a fast photo-detector, such as a microchannel plate photomultiplier tube (MCP-PMT) can reach the CTR better than 100 ps full width at half maximum (FWHM). Previously, we have developed the Cherenkov detector where the Cherenkov radiator is integrated with the MCP-PMT to enhance the timing performance, and the CTR of 41.9 ps FWHM was obtained. In this study, we performed two types of experiments; (1) increasing statistics roughly ten times larger than the previous study to precisely determine the timing performance of the detector, (2) stepping a 22 Na point source and validating transitions of timing histograms according to the source positions. As a result, the CTR of 41.7 ps FWHM was obtained. Moreover, the CTR between the radiator and the MCP direct interaction was also investigated and approximately 55 ps FWHM was obtained. The transitions of the timing histograms according to the source positions were successfully observed. Finally, we show physical components affecting the CTR and potential capability toward the ultimate goal of 10 ps CTR is discussed.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Timing Performance of Cherenkov-Radiator-Integrated MCP-PMT
Coincidence time resolution (CTR) of 10 ps is an ultimate goal toward reconstruction-less positron emission tomography (PET). One of the ways to enhance the timing performance of the PET detector is to make use of Cherenkov photons which is promptly emitted on the order of picosecond. A Cherenkov detector composed of a Cherenkov radiator and a fast photo-detector, such as a microchannel plate photomultiplier tube (MCP-PMT) can reach the CTR better than 100 ps full width at half maximum (FWHM). Previously, we have developed the Cherenkov detector where the Cherenkov radiator is integrated with the MCP-PMT to enhance the timing performance, and the CTR of 41.9 ps FWHM was obtained. In this study, we performed two types of experiments; (1) increasing statistics roughly ten times larger than the previous study to precisely determine the timing performance of the detector, (2) stepping a 22 Na point source and validating transitions of timing histograms according to the source positions. As a result, the CTR of 41.7 ps FWHM was obtained. Moreover, the CTR between the radiator and the MCP direct interaction was also investigated and approximately 55 ps FWHM was obtained. The transitions of the timing histograms according to the source positions were successfully observed. Finally, we show physical components affecting the CTR and potential capability toward the ultimate goal of 10 ps CTR is discussed.
- Open Access
- 20 March 2014
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 66, 08008
CANDLES
CANDLES is the project to search for neutrino-less double beta decay (0νββ) of 48Ca. The observation of 0νββ will prove existence of a massive Majorana neutrino. For the 0νββ measurement, we need a low background condition because of a low decay rate of 0νββ. Now we installed the CANDLES III system at the Kamioka underground laboratory. The CANDLES III system realizes the low background condition by a characteristic structure and data analyses for background rejection. Here we report performances of the CANDLES III system.
- 20 March 2014
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 66, 08008
Open AccessCANDLES
CANDLES is the project to search for neutrino-less double beta decay (0νββ) of 48Ca. The observation of 0νββ will prove existence of a massive Majorana neutrino. For the 0νββ measurement, we need a low background condition because of a low decay rate of 0νββ. Now we installed the CANDLES III system at the Kamioka underground laboratory. The CANDLES III system realizes the low background condition by a characteristic structure and data analyses for background rejection. Here we report performances of the CANDLES III system.