E. Bryn Pitt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
E. Bryn Pitt has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Eric John Barth
Vanderbilt University
8 shared publications Brian D. Sierawski
Department of Electrical Engineering and Computer Science, Vanderbilt University, Nashville, TN, USA
4 shared publications- Gabor Karsai
Vanderbilt University Vanderbilt University Vanderbilt University Vanderbilt University Vanderbilt University
4 shared publications Michael L. Alles
Department of Electrical Engineering and Computer Science, Vanderbilt University, Nashville, TN, USA
4 shared publicationsNagabhushan Mahadevan
Department of Electrical Engineering and Computer Science, Vanderbilt University, Nashville, TN, USA
4 shared publicationsRobert A. Reed
Department of Electrical Engineering and Computer Science, Vanderbilt University, Nashville, TN, USA
4 shared publications
Latest Publications
- Open Access
- 1 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Engineering in Medicine and Biology
- Vol. 5, 133-139
A Safe Framework for Quantitative In Vivo Human Evaluation of Image Guidance
Goal: We present a new framework for in vivo image guidance evaluation and provide a case study on robotic partial nephrectomy. Methods: This framework (called the “bystander protocol”) involves two surgeons, one who solely performs the therapeutic process without image guidance, and another who solely periodically collects data to evaluate image guidance. This isolates the evaluation from the therapy, so that in-development image guidance systems can be tested without risk of negatively impacting the standard of care. We provide a case study applying this protocol in clinical cases during robotic partial nephrectomy surgery. Results: The bystander protocol was performed successfully in 6 patient cases. We find average lesion centroid localization error with our IGS system to be 6.5 mm in vivo compared to our prior result of 3.0 mm in phantoms. Conclusions: The bystander protocol is a safe, effective method for testing in-development image guidance systems in human subjects.
- 1 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Engineering in Medicine and Biology
- Vol. 5, 133-139
Open AccessA Safe Framework for Quantitative In Vivo Human Evaluation of Image Guidance
Goal: We present a new framework for in vivo image guidance evaluation and provide a case study on robotic partial nephrectomy. Methods: This framework (called the “bystander protocol”) involves two surgeons, one who solely performs the therapeutic process without image guidance, and another who solely periodically collects data to evaluate image guidance. This isolates the evaluation from the therapy, so that in-development image guidance systems can be tested without risk of negatively impacting the standard of care. We provide a case study applying this protocol in clinical cases during robotic partial nephrectomy surgery. Results: The bystander protocol was performed successfully in 6 patient cases. We find average lesion centroid localization error with our IGS system to be 6.5 mm in vivo compared to our prior result of 3.0 mm in phantoms. Conclusions: The bystander protocol is a safe, effective method for testing in-development image guidance systems in human subjects.
- 1 September 2020
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 16 (6) , 1-10
Comparing the accuracy of the da Vinci Xi and da Vinci Si for image guidance and automation
Background Current laparoscopic surgical robots are teleoperated, which requires high fidelity differential motions but does not require absolute accuracy. Emerging applications, including image guidance and automation, require absolute accuracy. The absolute accuracy of the da Vinci Xi robot has not yet been characterized or compared to the Si system, which is now being phased out. This paper compares the accuracy of the two. Methods We measure robot tip positions and encoder values assessing accuracy with and without robot calibration. Results: The Si is accurate if the setup joints are not moved but loses accuracy otherwise. The Xi is always accurate. Conclusion The Xi can achieve submillimetric average error. Calibration improves accuracy, but excellent baseline accuracy of the Xi means that calibration may not be needed for some applications. Importantly, the external tracking systems needed to account for setup joint error in the Si are no longer required with the Xi.
- 1 September 2020
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 16 (6) , 1-10
Comparing the accuracy of the da Vinci Xi and da Vinci Si for image guidance and automation
Background Current laparoscopic surgical robots are teleoperated, which requires high fidelity differential motions but does not require absolute accuracy. Emerging applications, including image guidance and automation, require absolute accuracy. The absolute accuracy of the da Vinci Xi robot has not yet been characterized or compared to the Si system, which is now being phased out. This paper compares the accuracy of the two. Methods We measure robot tip positions and encoder values assessing accuracy with and without robot calibration. Results: The Si is accurate if the setup joints are not moved but loses accuracy otherwise. The Xi is always accurate. Conclusion The Xi can achieve submillimetric average error. Calibration improves accuracy, but excellent baseline accuracy of the Xi means that calibration may not be needed for some applications. Importantly, the external tracking systems needed to account for setup joint error in the Si are no longer required with the Xi.
- Open Access
- 10 April 2017
- Published by ASME International
Treating Epilepsy via Thermal Ablation: Initial Experiments With an MRI-Guided Concentric Tube Robot
Epilepsy is a prevalent neurological disorder affecting 65 million people globally [1]. Anti-epileptic medications fail to provide effective seizure control for 30% of patients, placing them at a 7–17% risk of Sudden Unexplained Death in Epilepsy and recurrent seizures. Surgical resection of the seizure focus is a potentially curative treatment for patients with seizures that electrophysiologically correlate to a focal lesion. For these patients, focal surgical resection can result in 60–70% seizure-freedom rates [2]. However, open resection carries the risk of cognitive impairment or focal neurologic deficit [3]. Recent innovations in MRI enable high resolution soft tissue visualization, and real-time temperature monitoring, making MR-guided ablation therapy a promising minimally invasive technique to restrict the tissue destruction to just the seizure focus. Commercial products (e.g., Visualase, Medtronic Inc.; ClearPoint, MRI Interventions Inc.; NeuroBlate, Monteris Inc.) have recently been introduced for MR-guided laser-based thermal ablation. These products require the physician drill a hole into the skull for ablation probe placement, and may not always be able to ablate the entire seizure focus when the structure has a curved shape (such as the hippocampus) [4]. Incomplete ablation of the seizure focus would lead to seizure recurrence. We have recently proposed concentric-tube steerable needles as a means to address these challenges [4–7]. They enable nonlinear trajectories and offer the potential to enter the brain through the patient’s cheek via a natural opening in the skull base (i.e. the foramen ovale). We have designed and fabricated an MR-compatible robotic system to provide high resolution actuation for helical needle deployment [5]. We have shown in simulation that the curved medial axis of hippocampus can be accessed via a helical needle that delivers the ablation probe into the brain [4]. These preliminary results suggest that MR-guided robotic transforamenal thermal therapy could potentially provide a less invasive approach for potentially curative epilepsy treatment. In this paper we present our first results delivering heat along curved paths in brain phantoms and imaging the resulting treatment zones using MRI.
- 10 April 2017
- Published by ASME International
Open AccessTreating Epilepsy via Thermal Ablation: Initial Experiments With an MRI-Guided Concentric Tube Robot
Epilepsy is a prevalent neurological disorder affecting 65 million people globally [1]. Anti-epileptic medications fail to provide effective seizure control for 30% of patients, placing them at a 7–17% risk of Sudden Unexplained Death in Epilepsy and recurrent seizures. Surgical resection of the seizure focus is a potentially curative treatment for patients with seizures that electrophysiologically correlate to a focal lesion. For these patients, focal surgical resection can result in 60–70% seizure-freedom rates [2]. However, open resection carries the risk of cognitive impairment or focal neurologic deficit [3]. Recent innovations in MRI enable high resolution soft tissue visualization, and real-time temperature monitoring, making MR-guided ablation therapy a promising minimally invasive technique to restrict the tissue destruction to just the seizure focus. Commercial products (e.g., Visualase, Medtronic Inc.; ClearPoint, MRI Interventions Inc.; NeuroBlate, Monteris Inc.) have recently been introduced for MR-guided laser-based thermal ablation. These products require the physician drill a hole into the skull for ablation probe placement, and may not always be able to ablate the entire seizure focus when the structure has a curved shape (such as the hippocampus) [4]. Incomplete ablation of the seizure focus would lead to seizure recurrence. We have recently proposed concentric-tube steerable needles as a means to address these challenges [4–7]. They enable nonlinear trajectories and offer the potential to enter the brain through the patient’s cheek via a natural opening in the skull base (i.e. the foramen ovale). We have designed and fabricated an MR-compatible robotic system to provide high resolution actuation for helical needle deployment [5]. We have shown in simulation that the curved medial axis of hippocampus can be accessed via a helical needle that delivers the ablation probe into the brain [4]. These preliminary results suggest that MR-guided robotic transforamenal thermal therapy could potentially provide a less invasive approach for potentially curative epilepsy treatment. In this paper we present our first results delivering heat along curved paths in brain phantoms and imaging the resulting treatment zones using MRI.
- 15 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 17 (4) , 1132-1143
Radiation Response and Adaptive Control-Based Degradation Mitigation of MEMS Accelerometers in Ionizing Dose Environments
This paper investigates the effects of gamma radiation on the operation of commercially available capacitive microelectromechanical accelerometers intended for use in robotic systems deployed for nuclear disaster remediation. Radiation-induced accelerometer degradation is examined in terms of its effects on the input-output relationship of ADXL325 accelerometers (Analog Devices, Inc., Norwood, Massachusetts, USA) prior to sensor failure. Results show a moderate increase in sensor nonlinearity as well as significant, non-monotonic changes to accelerometer axis sensitivity and zero-g bias. Both part-to-part variation and axis-to-axis variation within individual accelerometers are observed. The effects of the observed accelerometer degradation on the performance of a simple robotic manipulator that relies on acceleration feedback are evaluated in simulation. Additionally, using tools derived from adaptive control theory, this paper presents a real-time recalibration technique for mitigating the effects of the measured accelerometer degradation on the performance of robotic systems that can be applied in-field, without the knowledge of the degradation mechanisms. An example implementation of this technique is also evaluated. Results suggest that control-based strategies for mitigating hardware degradation may be able to extend the useful operating lifetime of non-radiation-hardened sensors in robotic systems deployed in extreme radiation environments.
- 15 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 17 (4) , 1132-1143
Radiation Response and Adaptive Control-Based Degradation Mitigation of MEMS Accelerometers in Ionizing Dose Environments
This paper investigates the effects of gamma radiation on the operation of commercially available capacitive microelectromechanical accelerometers intended for use in robotic systems deployed for nuclear disaster remediation. Radiation-induced accelerometer degradation is examined in terms of its effects on the input-output relationship of ADXL325 accelerometers (Analog Devices, Inc., Norwood, Massachusetts, USA) prior to sensor failure. Results show a moderate increase in sensor nonlinearity as well as significant, non-monotonic changes to accelerometer axis sensitivity and zero-g bias. Both part-to-part variation and axis-to-axis variation within individual accelerometers are observed. The effects of the observed accelerometer degradation on the performance of a simple robotic manipulator that relies on acceleration feedback are evaluated in simulation. Additionally, using tools derived from adaptive control theory, this paper presents a real-time recalibration technique for mitigating the effects of the measured accelerometer degradation on the performance of robotic systems that can be applied in-field, without the knowledge of the degradation mechanisms. An example implementation of this technique is also evaluated. Results suggest that control-based strategies for mitigating hardware degradation may be able to extend the useful operating lifetime of non-radiation-hardened sensors in robotic systems deployed in extreme radiation environments.
- Open Access
- 25 July 2016
- Published by Wolters Kluwer Health in Operative Neurosurgery
- Vol. 13 (1) , 15-22
Optimization of Curvilinear Needle Trajectories for Transforamenal Hippocampotomy
BACKGROUND: The recently developed magnetic resonance imaging–guided laser-induced thermal therapy offers a minimally invasive alternative to craniotomies performed for tumor resection or for amygdalohippocampectomy to control seizure disorders. Current laser-induced thermal therapies rely on linear stereotactic trajectories that mandate twist-drill entry into the skull and potentially long approaches traversing healthy brain. The use of robotically driven, telescoping, curved needles has the potential to reduce procedure invasiveness by tailoring trajectories to the curved shape of the ablated structure and by enabling access through natural orifices. OBJECTIVE: To investigate the feasibility of using a concentric tube robot to access the hippocampus through the foramen ovale to deliver thermal therapy and thereby provide a percutaneous treatment for epilepsy without drilling the skull. METHODS: The skull and both hippocampi were segmented from dual computed tomography/magnetic resonance image volumes for 10 patients. For each of the 20 hippocampi, a concentric tube robot was designed and optimized to traverse a trajectory from the foramen ovale to and through the hippocampus from head to tail. RESULTS: Across all 20 cases, the mean distances (errors) between the hippocampus medial axis and backbone of the needle were 0.55, 1.11, and 1.66 mm for the best, mean, and worst case, respectively. CONCLUSION: These curvilinear trajectories would provide accurate transforamenal delivery of an ablation probe to typical hippocampus volumes. This strategy has the potential both to decrease the invasiveness of the procedure and to increase the completeness of hippocampal ablation.
- 25 July 2016
- Published by Wolters Kluwer Health in Operative Neurosurgery
- Vol. 13 (1) , 15-22
Open AccessOptimization of Curvilinear Needle Trajectories for Transforamenal Hippocampotomy
BACKGROUND: The recently developed magnetic resonance imaging–guided laser-induced thermal therapy offers a minimally invasive alternative to craniotomies performed for tumor resection or for amygdalohippocampectomy to control seizure disorders. Current laser-induced thermal therapies rely on linear stereotactic trajectories that mandate twist-drill entry into the skull and potentially long approaches traversing healthy brain. The use of robotically driven, telescoping, curved needles has the potential to reduce procedure invasiveness by tailoring trajectories to the curved shape of the ablated structure and by enabling access through natural orifices. OBJECTIVE: To investigate the feasibility of using a concentric tube robot to access the hippocampus through the foramen ovale to deliver thermal therapy and thereby provide a percutaneous treatment for epilepsy without drilling the skull. METHODS: The skull and both hippocampi were segmented from dual computed tomography/magnetic resonance image volumes for 10 patients. For each of the 20 hippocampi, a concentric tube robot was designed and optimized to traverse a trajectory from the foramen ovale to and through the hippocampus from head to tail. RESULTS: Across all 20 cases, the mean distances (errors) between the hippocampus medial axis and backbone of the needle were 0.55, 1.11, and 1.66 mm for the best, mean, and worst case, respectively. CONCLUSION: These curvilinear trajectories would provide accurate transforamenal delivery of an ablation probe to typical hippocampus volumes. This strategy has the potential both to decrease the invasiveness of the procedure and to increase the completeness of hippocampal ablation.
- 12 May 2016
- Published by ASME International in Journal of Medical Devices
- Vol. 10 (2) , 020945
Follow-the-Leader Deployment of Steerable Needles Using a Magnetic Resonance-Compatible Robot With Stepper Actuators1
- 12 May 2016
- Published by ASME International in Journal of Medical Devices
- Vol. 10 (2) , 020945
Follow-the-Leader Deployment of Steerable Needles Using a Magnetic Resonance-Compatible Robot With Stepper Actuators1
- 17 December 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 62 (6) , 2517-2524
Bayesian Inference Modeling of Total Ionizing Dose Effects on System Performance
A probabilistic Bayesian modeling method for determining the effects of radiation-induced component-level parameter shifts on system-level performance is described. The modeling method incorporates information about the system design and component-level degradation into a Bayesian network and performs inference on the constructed network using Markov chain Monte Carlo approaches, producing distributions for the range of component responses. Deterministic simulations use the results of the Bayesian inference to determine the combined impact of multiple degraded components on system performance quantities. The goal of the modeling approach is to turn uncertain information into actionable knowledge. The utility of this approach is demonstrated using a case study based on total ionizing dose degradation of line-sensor components in a simple line-tracking robot system.
- 17 December 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 62 (6) , 2517-2524
Bayesian Inference Modeling of Total Ionizing Dose Effects on System Performance
A probabilistic Bayesian modeling method for determining the effects of radiation-induced component-level parameter shifts on system-level performance is described. The modeling method incorporates information about the system design and component-level degradation into a Bayesian network and performs inference on the constructed network using Markov chain Monte Carlo approaches, producing distributions for the range of component responses. Deterministic simulations use the results of the Bayesian inference to determine the combined impact of multiple degraded components on system performance quantities. The goal of the modeling approach is to turn uncertain information into actionable knowledge. The utility of this approach is demonstrated using a case study based on total ionizing dose degradation of line-sensor components in a simple line-tracking robot system.
- 12 October 2015
- Published by ASME International
An Investigation of Stiffness Modulation Limits in a Pneumatically Actuated Parallel Robot With Actuation Redundancy
Actuation redundancy in parallel mechanisms has been predominantly investigated assuming electromechanical actuators. Pneumatic actuation offers new alternatives to achieving stiffness modulation in parallel robots. This paper investigates the limits of stiffness modulation using two alternatives: modulation of joint-level stiffness using antagonistic pneumatic actuators (passive stiffness modulation) and stiffness modulation using antagonistic actuation at the structure level (active stiffness modulation). A surrogate translational parallel robot architecture, which is a variant of the Delta robot with one redundant kinematic chain, is used in this investigation. A simplified model of a pneumatic double-acting piston actuator is used to establish upper and lower bounds for attainable joint-level stiffness. A kinematic model of the parallel robot is presented along with its passive and active stiffness models. A simulation study is carried out assuming attainable joint-level stiffness based on the simplified pneumatic actuator model. The simulations show that, due to the achievable low pneumatic actuator stiffness, the active stiffness contribution can be as high as 65% of the passive stiffness within the robot workspace. This preliminary investigation suggests that pneumatic actuators are uniquely suited for robot interaction tasks (e.g. assembly or rehabilitation) where stiffness control and modulation can offer increased safety and task-specific end-effector stiffness.
- 12 October 2015
- Published by ASME International
An Investigation of Stiffness Modulation Limits in a Pneumatically Actuated Parallel Robot With Actuation Redundancy
Actuation redundancy in parallel mechanisms has been predominantly investigated assuming electromechanical actuators. Pneumatic actuation offers new alternatives to achieving stiffness modulation in parallel robots. This paper investigates the limits of stiffness modulation using two alternatives: modulation of joint-level stiffness using antagonistic pneumatic actuators (passive stiffness modulation) and stiffness modulation using antagonistic actuation at the structure level (active stiffness modulation). A surrogate translational parallel robot architecture, which is a variant of the Delta robot with one redundant kinematic chain, is used in this investigation. A simplified model of a pneumatic double-acting piston actuator is used to establish upper and lower bounds for attainable joint-level stiffness. A kinematic model of the parallel robot is presented along with its passive and active stiffness models. A simulation study is carried out assuming attainable joint-level stiffness based on the simplified pneumatic actuator model. The simulations show that, due to the achievable low pneumatic actuator stiffness, the active stiffness contribution can be as high as 65% of the passive stiffness within the robot workspace. This preliminary investigation suggests that pneumatic actuators are uniquely suited for robot interaction tasks (e.g. assembly or rehabilitation) where stiffness control and modulation can offer increased safety and task-specific end-effector stiffness.
- 18 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 21 (2) , 717-726
Analytical Tools for Investigating Stability and Power Generation of Electromagnetic Vibration Energy Harvesters
This paper presents a general linear methodology for analyzing how the choice of electrical load affects stability and average power generation of an electromagnetic vibration energy harvester. Using bond graph techniques, the entire electromechanical harvesting system is modeled as a dynamically equivalent electrical circuit and ultimately recast as a feedback control system. This modeling approach enables the use of well-established linear control tools to assess the overall stability of the energy harvesting system. These tools are used to show: 1) why the load which would result in maximum power transfer from the harvester to the load, as established by the maximum power transfer theorem (MPTT), can only be achieved at a single frequency, and 2) how to ensure the system will always remain stable if the harvester is used in conjunction with an active load. Moreover, the presented modeling approach enables development of the power harvesting ratio-an analytical method for quantifying the harvester's power generation when multi-frequency excitation is involved. A custom harvester was constructed for experimental evaluation of the power harvesting ratio when varying: 1) the electrical load attached across the harvester leads and 2) the multifrequency vibrations used to excite the harvester.
- 18 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 21 (2) , 717-726
Analytical Tools for Investigating Stability and Power Generation of Electromagnetic Vibration Energy Harvesters
This paper presents a general linear methodology for analyzing how the choice of electrical load affects stability and average power generation of an electromagnetic vibration energy harvester. Using bond graph techniques, the entire electromechanical harvesting system is modeled as a dynamically equivalent electrical circuit and ultimately recast as a feedback control system. This modeling approach enables the use of well-established linear control tools to assess the overall stability of the energy harvesting system. These tools are used to show: 1) why the load which would result in maximum power transfer from the harvester to the load, as established by the maximum power transfer theorem (MPTT), can only be achieved at a single frequency, and 2) how to ensure the system will always remain stable if the harvester is used in conjunction with an active load. Moreover, the presented modeling approach enables development of the power harvesting ratio-an analytical method for quantifying the harvester's power generation when multi-frequency excitation is involved. A custom harvester was constructed for experimental evaluation of the power harvesting ratio when varying: 1) the electrical load attached across the harvester leads and 2) the multifrequency vibrations used to excite the harvester.
- 10 July 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 62 (4) , 1674-1681
System Health Awareness in Total-Ionizing Dose Environments
Understanding the relationship between the impact of radiation at the component and system levels is challenging. This paper discusses a hierarchical approach, based on Bayesian theory, to establish a mechanism for determining system health based on the status of, and interactions between, the radiation response of component parts. When the Bayesian network is trained with a combination of experimental data, data from similar parts, simulations, and expert estimates, a quantitative estimate of the Total-Ionizing Dose (TID) response of a system can be obtained. Bayesian networks enable inference about system-level functional performance, the dose exposure, and the sensitivity of different components to TID, thus providing a framework for TID awareness in design and operation of systems. A case study of a robotic system consisting of commercial components is presented.
- 10 July 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 62 (4) , 1674-1681
System Health Awareness in Total-Ionizing Dose Environments
Understanding the relationship between the impact of radiation at the component and system levels is challenging. This paper discusses a hierarchical approach, based on Bayesian theory, to establish a mechanism for determining system health based on the status of, and interactions between, the radiation response of component parts. When the Bayesian network is trained with a combination of experimental data, data from similar parts, simulations, and expert estimates, a quantitative estimate of the Total-Ionizing Dose (TID) response of a system can be obtained. Bayesian networks enable inference about system-level functional performance, the dose exposure, and the sensitivity of different components to TID, thus providing a framework for TID awareness in design and operation of systems. A case study of a robotic system consisting of commercial components is presented.