ASAlexandros A. Sklavounos

Alexandros A. Sklavounos

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Alexandros A. Sklavounos has a total of 83 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A combined digital microfluidic test for assessing infection and immunity status for viral disease in saliva

    by N. Sathishkumar, Jose Gilberto Camacho Valenzuela, Nguyen H. Le, Anthony K. C. Yong, Martin A. Rossotti, Joshua Dahmer, Alexandros A. Sklavounos, Martin Plante, Daniel Brassard, Lidija Malic, et al.

    Population assessments of infection and immunity status are critical for public health response to infectious disease. Most microfluidic tools are developed to assess one or the other – few assess both. This study introduces a multiplexed, fully automated digital microfluidic (DMF) platform designed to detect viral protein as a proxy for infection status and host IgG and IgA antibodies as a marker for immunity status. SARS-CoV-2 and patient saliva were used as a model system to evaluate the concept. Specifically, the infection assay relied on nanobody-based capture and detection agents specific to SARS-CoV-2 trimeric spike protein, with a limit of detection (LOD) of 3.8 ng mL−1 in saliva. And the immunity relied on monoclonal antibodies for host IgG and IgA specific to SARS-CoV-2 spike S1 domain, with LODs of 4.8 ng mL−1 and 13.3 ng mL−1 in saliva, respectively. Clinical validation in saliva samples from human subjects experiencing symptoms (n = 14) showed strong correlation with PCR and commercial ELISA, achieving 100% sensitivity and 100% specificity for infection detection and 100% sensitivity with 91.7% and 90.9% specificity for host IgG and IgA, respectively. These results highlight potential applications for the new system as a portable diagnostic tool for outbreak surveillance and public health management, as a step toward preparing for the next global pandemic.


  • Open Access

    A digital microfluidic approach to increasing sample volume and reducing bead numbers in single molecule array assays

    by Alinaghi Salari, Jose Gilberto Camacho Valenzuela, Nguyen Le, Joshua Dahmer, Alexandros A. Sklavounos, Cheuk W. Kan, Ryan Manning, David C. Duffy, Nira R. Pollock, Aaron R. Wheeler

    Digital microfluidics enables processing of large sample volumes (up to 100 μL) with low bead counts (as few as 5000) in single molecule array assays.


  • A multimodal digital microfluidic testing platform for antibody-producing cell lines

    by Jeremy T. Lant, Jurgen Frasheri, Taehong Kwon, Camille M. N. Tsang, Bingyu B. Li, Sheldon Decombe, Alexandros A. Sklavounos, Samin Akbari, Aaron R. Wheeler

    In recent years, monoclonal antibodies (mAbs) have become a powerful tool in the treatment of human diseases. Currently, over 100 mAbs have received approval for therapeutic use in the US, with wide-ranging applications from cancer to infectious diseases. The predominant method of producing antibodies for therapeutics involves expression in mammalian cell lines. In the mAb production process, significant optimization is typically done to maximize antibody titres from cells grown in bioreactors. Therefore, systems that can miniaturize and automate cell line testing (e.g., viability and antibody production assays) are valuable in reducing therapeutic mAb development costs. Here we present a novel platform for cell line optimization for mAb production using digital microfluidics. The platform enables testing of cell culture samples in 6–8 μL droplets with semi-automated viability, media pH, and antibody production assays. This system provides a unique bridge between cell growth and productivity metrics, while minimizing culture volume requirements for daily testing. We propose that this technology and its future iterations has the potential to help reduce the time-to-market and development costs of antibody-producing cell lines.


  • Open Access

    WITHDRAWN: Digital microfluidics as an emerging tool for bacterial protocols

    by Carine R. Nemr, Alexandros A. Sklavounos, Aaron R. Wheeler, Shana O. Kelley

  • Open Access

    Digital microfluidics with distance-based detection – a new approach for nucleic acid diagnostics

    by Man Ho, N. Sathishkumar, Alexandros A. Sklavounos, Jianxian Sun, Ivy Yang, Kevin P. Nichols, Aaron R. Wheeler

    There is great enthusiasm for using loop-mediated isothermal amplification (LAMP) in point-of-care nucleic acid amplification tests (POC NAATs), as an alternative to PCR. While isothermal amplification techniques like LAMP eliminate the need for rapid temperature cycling in a portable format, these systems are still plagued by requirements for dedicated optical detection apparatus for analysis and manual off-chip sample processing. Here, we developed a new microfluidic system for LAMP-based POC NAATs to address these limitations. The new system combines digital microfluidics (DMF) with distance-based detection (DBD) for direct signal readout. This is the first report of the use of (i) LAMP or (ii) DMF with DBD – thus, we describe a number of characterization steps taken to determine optimal combinations of reagents, materials, and processes for reliable operation. For example, DBD was found to be quite sensitive to background signals from low molecular weight LAMP products; thus, a Capto™ adhere bead-based clean-up procedure was developed to isolate the desirable high-molecular-weight products for analysis. The new method was validated by application to detection of SARS-CoV-2 in saliva. The method was able to distinguish between saliva containing no virus, saliva containing a low viral load (104 genome copies per mL), and saliva containing a high viral load (108 copies per mL), all in an automated system that does not require detection apparatus for analysis. We propose that the combination of DMF with distance-based detection may be a powerful one for implementing a variety of POC NAATs or for other applications in the future.


  • Digital Microfluidics for Microproteomic Analysis of Minute Mammalian Tissue Samples Enabled by a Photocleavable Surfactant

    by Calvin Chan, Jiaxi Peng, Vigneshwar Rajesh, Erica Y. Scott, Alexandros A. Sklavounos, Maryam Faiz, Aaron R. Wheeler

    Proteome profiles of precious tissue samples have great clinical potential for accelerating disease biomarker discovery and promoting novel strategies for early diagnosis and treatment. However, tiny clinical tissue samples are often difficult to handle and analyze with conventional proteomic methods. Automated digital microfluidic (DMF) workflows facilitate the manipulation of size-limited tissue samples. Here, we report the assessment of a DMF microproteomics workflow enabled by a photocleavable surfactant for proteomic analysis of minute tissue samples. The surfactant 4-hexylphenylazosulfonate (Azo) was found to facilitate fast droplet movement on DMF and enhance the proteomics analysis. Comparisons of Azo and n-Dodecyl beta-D-maltoside (DDM) using small samples of HeLa digest standards and MCF-7 cell digests revealed distinct differences at the peptide level despite similar results at the protein level. The DMF microproteomics workflow was applied for the sample preparation of similar to 3 mu g biopsies from murine brain tissue. A total of 1969 proteins were identified in three samples, including established neural biomarkers and proteins related to synaptic signaling. Going forward, we propose that the Azo-enabled DMF workflow has the potential to advance the practical clinical application of DMF for the analysis of size-limited tissue samples.


  • Open Access

    All-in-One digital microfluidics pipeline for proteomic sample preparation and analysis

    by Jiaxi Peng, Calvin Chan, Shuailong Zhang, Alexandros A. Sklavounos, Maxwell E. Olson, Erica Y. Scott, Yechen Hu, Vigneshwar Rajesh, Bingyu B. Li, M. Dean Chamberlain, et al.

    The All-in-One digital microfluidic pipeline allows for end-to-end automation of processing and analysis of mass-limited proteomic samples.


  • Antifouling Properties of Pluronic and Tetronic Surfactants in Digital Microfluidics

    by Man Ho, Aaron Au, Robert Flick, Thu V. Vuong, Alexandros A. Sklavounos, Ian Swyer, Christopher M. Yip, Aaron R. Wheeler

    Fouling at liquid-solid interfaces is a pernicious problem for a wide range of applications, including those that are implemented by digital microfluidics (DMF). There are several strategies that have been used to combat surface fouling in DMF, the most common being inclusion of amphiphilic surfactant additives in the droplets to be manipulated. Initial studies relied on Pluronic additives, and more recently, Tetronic additives have been used, which has allowed manipulation of complex samples like serum and whole blood. Here, we report our evaluation of 19 different Pluronic and Tetronic additives, with attempts to determine (1) the difference in antifouling performance between the two families, (2) the structural similarities that predict exceptional antifouling performance, and (3) the mechanism of the antifouling behavior. Our analysis shows that both Pluronic and Tetronic additives with modest molar mass, poly(propylene oxide) (PPO) ≥50 units, poly(ethylene oxide) (PEO) mass percentage ≤50%, and hydrophilic-lipophilic balance (HLB) ca. 13-15 allow for exceptional antifouling performance in DMF. The most promising candidates, P104, P105, and T904, were able to support continuous movement of droplets of serum for more than 2 h, a result (for devices operating in air) previously thought to be out of reach for this technique. Additional results generated using device longevity assays, intrinsic fluorescence measurements, dynamic light scattering, asymmetric flow field flow fractionation, supercritical angle fluorescence microscopy, atomic force microscopy, and quartz crystal microbalance measurements suggest that the best-performing surfactants are more likely to operate by forming a protective layer at the liquid-solid interface than by complexation with proteins. We propose that these results and their implications are an important step forward for the growing community of users of this technique, which may provide guidance in selecting surfactants for manipulating biological matrices for a wide range of applications.


  • Open Access

    Digital microfluidics as an emerging tool for bacterial protocols

    by Carine R. Nemr, Alexandros A. Sklavounos, Aaron R. Wheeler, Shana O. Kelley


  • Translating diagnostics and drug delivery technologies to low-resource settings

    by Erin M. Euliano, Alexandros A. Sklavounos, Aaron R. Wheeler, Kevin J. McHugh

    Diagnostics and drug delivery technologies engineered for low-resource settings aim to meet their technical design specifications using strategies that are compatible with limited equipment, infrastructure, and operator training. Despite many preclinical successes, very few of these devices have been translated to the clinic. Here, we identify factors that contribute to the clinical success of diagnostics and drug delivery systems for low-resource settings, including the need to engage key stakeholders at an early stage, and provide recommendations for the clinical translation of future medical technologies.