Fabrício Borges de Oliveira
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Fabrício Borges de Oliveira has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Markus Bartscher
Physikalisch-Technische Bundesanstalt (PTB)
3 shared publications Ulrich Neuschaefer-Rube
3 shared publications- David Plotzki
Bundesanstalt für Materialforschung und -prüfung (BAM), Unter den Eichen 87, 12205 Berlin, Germany
2 shared publications Florian Wohlgemuth
HEITEC PTS GmbH, Kuchen, Germany
2 shared publicationsMarkus Bartscher
2 shared publicationsRainer Tutsch
2 shared publications
Latest Publications
- 27 March 2023
- Published by Elsevier in Precision Engineering
- Vol. 82, 184-198
On the importance of multi-material acceptance testing for CT-based CMSs
- 27 March 2023
- Published by Elsevier in Precision Engineering
- Vol. 82, 184-198
On the importance of multi-material acceptance testing for CT-based CMSs
- Open Access
- 21 March 2023
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 34 (6) , 064005
Assessment of 2D-based tests for the qualification of simulation software for dXCT
The interest in using computer simulations of dimensional x-ray computed tomography (dXCT) for various metrological purposes—such as measurement planning, performance prediction, performance optimisation and, finally, measurement uncertainty estimation—is increasing along with the ever-growing demand for more reliable measurements with dXCT. However, before a piece of simulation software can be used for tasks related to coordinate metrology, it has to be ensured that it is able to simulate physical laws, characteristic effects and basic CT system functionalities correctly and with sufficient accuracy. In short, the software must be qualified for dimensional metrology tasks. As one part of such a qualification process, a method is presented here for determining conformity intervals of 2D tests (projection-based tests) based on 3D tests (testing based on dimensional evaluations in a reconstructed volume) for the assessment of dXCT simulation software. The method consists of varying relevant parameter values in order to verify their influence on 3D measurement results. The results of the 3D tests with varied parameter values are then transferred to the quantities tested in the 2D tests and used as the basis for determining conformity intervals. Two approaches are applied for determining whether or not a variation of a parameter value is significant: (a) statistical and (b) heuristic. Two examples are presented, each based on simulated images, which show the application of the two different approaches for determining conformity intervals for the results of the 2D tests.
- 21 March 2023
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 34 (6) , 064005
Open AccessAssessment of 2D-based tests for the qualification of simulation software for dXCT
The interest in using computer simulations of dimensional x-ray computed tomography (dXCT) for various metrological purposes—such as measurement planning, performance prediction, performance optimisation and, finally, measurement uncertainty estimation—is increasing along with the ever-growing demand for more reliable measurements with dXCT. However, before a piece of simulation software can be used for tasks related to coordinate metrology, it has to be ensured that it is able to simulate physical laws, characteristic effects and basic CT system functionalities correctly and with sufficient accuracy. In short, the software must be qualified for dimensional metrology tasks. As one part of such a qualification process, a method is presented here for determining conformity intervals of 2D tests (projection-based tests) based on 3D tests (testing based on dimensional evaluations in a reconstructed volume) for the assessment of dXCT simulation software. The method consists of varying relevant parameter values in order to verify their influence on 3D measurement results. The results of the 3D tests with varied parameter values are then transferred to the quantities tested in the 2D tests and used as the basis for determining conformity intervals. Two approaches are applied for determining whether or not a variation of a parameter value is significant: (a) statistical and (b) heuristic. Two examples are presented, each based on simulated images, which show the application of the two different approaches for determining conformity intervals for the results of the 2D tests.
- 4 May 2022
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 89 (10) , 671-686
Numerical measurement uncertainty evaluation for X-ray computed tomography using simulations – A first approach to build a digital twin
The ability of industrial X-ray computed tomography (CT) to scan an object with several internal and external features at once causes increasing adoption in dimensional metrology. In order to evaluate the quality of a measurement value, the task-specific measurement uncertainty has to be determined. Currently, VDI/VDE 2630 part 2.1 gives a guideline to determine the uncertainty of CT measurements experimentally by conducting repeated measurements. This is costly and time-consuming. Thus, the aim is to determine the task-specific measurement uncertainty numerically by simulations (e. g. according to the guide to expression of uncertainty in measurement (GUM) Supplement 1). To achieve that, a digital twin is necessary. This contribution presents a simple first approach how a digital twin can be built. In order to evaluate this approach, a study comparing measurements and simulations of different real CT systems was carried out by determining the differences between the measurement results of the digital twin and of the measurement results of the real-world CT systems. The results have shown a moderate agreement between real and simulated data. To improve on this aspect, a standardized method to characterize CT systems and methods to implement CT parameters into the simulation with sufficient accuracy will be developed.
- 4 May 2022
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 89 (10) , 671-686
Numerical measurement uncertainty evaluation for X-ray computed tomography using simulations – A first approach to build a digital twin
The ability of industrial X-ray computed tomography (CT) to scan an object with several internal and external features at once causes increasing adoption in dimensional metrology. In order to evaluate the quality of a measurement value, the task-specific measurement uncertainty has to be determined. Currently, VDI/VDE 2630 part 2.1 gives a guideline to determine the uncertainty of CT measurements experimentally by conducting repeated measurements. This is costly and time-consuming. Thus, the aim is to determine the task-specific measurement uncertainty numerically by simulations (e. g. according to the guide to expression of uncertainty in measurement (GUM) Supplement 1). To achieve that, a digital twin is necessary. This contribution presents a simple first approach how a digital twin can be built. In order to evaluate this approach, a study comparing measurements and simulations of different real CT systems was carried out by determining the differences between the measurement results of the digital twin and of the measurement results of the real-world CT systems. The results have shown a moderate agreement between real and simulated data. To improve on this aspect, a standardized method to characterize CT systems and methods to implement CT parameters into the simulation with sufficient accuracy will be developed.
- 4 May 2019
- Published by Springer Nature
- p. 131-154
Multi-material Acceptance Testing for CT-Based Coordinate Measurement Systems
- 4 May 2019
- Published by Springer Nature
- p. 131-154
Multi-material Acceptance Testing for CT-Based Coordinate Measurement Systems
- Open Access
- 12 December 2018
- Published by Springer Nature in Journal of Nondestructive Evaluation
- Vol. 38 (1) , 10
Case Study of Empirical Beam Hardening Correction Methods for Dimensional X-ray Computed Tomography Using a Dedicated Multi-material Reference Standard
- 12 December 2018
- Published by Springer Nature in Journal of Nondestructive Evaluation
- Vol. 38 (1) , 10
Open AccessCase Study of Empirical Beam Hardening Correction Methods for Dimensional X-ray Computed Tomography Using a Dedicated Multi-material Reference Standard
- Open Access
- 1 November 2016
- Published by Elsevier in Case Studies in Nondestructive Testing and Evaluation
- Vol. 6, 93-103
Experimental investigation of surface determination process on multi-material components for dimensional computed tomography
- 1 November 2016
- Published by Elsevier in Case Studies in Nondestructive Testing and Evaluation
- Vol. 6, 93-103
Open AccessExperimental investigation of surface determination process on multi-material components for dimensional computed tomography