Hye Young Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Hye Young Lee has a total of 162 co-authors. Here are the top co-authors by number of shared publications:
- Sean Andrew Kuvin
Los Alamos National Laboratory
11 shared publications - Panagiotis Gastis
Los Alamos National Laboratory
6 shared publications - Brad DiGiovine
Los Alamos National Laboratory
5 shared publications - Christiaan Vermeulen
Los Alamos National Laboratory
5 shared publications - D. Votaw
Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA
5 shared publications S. Mosby
Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA
5 shared publications
Latest Publications
- 3 June 2026
- Published by Office of Scientific and Technical Information (OSTI)
Possible paths for the production of 73As
Inelastic scattering reactions including (n,2n) are particularly difficult to measure. Hardly any measurements on radioactive nuclei exist. The reason is that traditional methods require the detection of gammas or neutrons in a background of elastically scattered neutrons, which can interact with the detector or other materials. The 73As(n,2n) and the 73As(n,2n) reaction cross sections are the only neutron removal cross sections that can be measured with current methods. The corresponding cross sections for the short-lived isotopes 71,72,74As can only be directly measured in inverse kinematics. Since 75As is the only stable isotope of this element, the sample production is no problem at all. This report is therefore focused on the sample production for a possible 73As(n,2n) campaign.
- 3 June 2026
- Published by Office of Scientific and Technical Information (OSTI)
Possible paths for the production of 73As
Inelastic scattering reactions including (n,2n) are particularly difficult to measure. Hardly any measurements on radioactive nuclei exist. The reason is that traditional methods require the detection of gammas or neutrons in a background of elastically scattered neutrons, which can interact with the detector or other materials. The 73As(n,2n) and the 73As(n,2n) reaction cross sections are the only neutron removal cross sections that can be measured with current methods. The corresponding cross sections for the short-lived isotopes 71,72,74As can only be directly measured in inverse kinematics. Since 75As is the only stable isotope of this element, the sample production is no problem at all. This report is therefore focused on the sample production for a possible 73As(n,2n) campaign.
- Open Access
- 22 January 2026
- Published by Office of Scientific and Technical Information (OSTI)
Study of neutron-induced charged particle reactions relevant to the synthesis of 40K in massive stars
- 22 January 2026
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessStudy of neutron-induced charged particle reactions relevant to the synthesis of 40K in massive stars
- 5 November 2025
- Published by American Physical Society (APS) in Physical Review C
- Vol. 112 (5)
Cross section measurements for the Zn 68 ( n , p ) Cu 68 and Zn 68 ( n , α ) Ni 65 reactions at neutron energies from 4 to 12 MeV
- 5 November 2025
- Published by American Physical Society (APS) in Physical Review C
- Vol. 112 (5)
Cross section measurements for the Zn 68 ( n , p ) Cu 68 and Zn 68 ( n , α ) Ni 65 reactions at neutron energies from 4 to 12 MeV
- Open Access
- 26 June 2025
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 327, 01006
Practical considerations for radioactive target fabrication for neutron-induced reaction studies at LANSCE
High quality nuclear reaction data for radionuclides is lacking, which can be best rectified by performing direct measurements of neutron-induced reactions on the target nuclei of interest. Two instruments at the Los Alamos Neutron Science Center, the Low Energy (n,Z) (LENZ) instrument and the Device for Indirect Capture Experiments on Radionuclides (DICER), can perform such measurements on radioactive targets. This manuscript covers the target requirements for such experiments and provides examples of how defects in the targets manifests in the measured data.
- 26 June 2025
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 327, 01006
Open AccessPractical considerations for radioactive target fabrication for neutron-induced reaction studies at LANSCE
High quality nuclear reaction data for radionuclides is lacking, which can be best rectified by performing direct measurements of neutron-induced reactions on the target nuclei of interest. Two instruments at the Los Alamos Neutron Science Center, the Low Energy (n,Z) (LENZ) instrument and the Device for Indirect Capture Experiments on Radionuclides (DICER), can perform such measurements on radioactive targets. This manuscript covers the target requirements for such experiments and provides examples of how defects in the targets manifests in the measured data.
- 11 June 2025
- Published by American Physical Society (APS) in Physical Review C
- Vol. 111 (6)
-matrix analysis of the system- 11 June 2025
- Published by American Physical Society (APS) in Physical Review C
- Vol. 111 (6)
-matrix analysis of the system- Open Access
- 1 May 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (5)
Gallium nitride (GaN) scintillation response to fast neutrons and flash gamma rays and associated broadband photoluminescence
Gallium nitride (GaN), a wide-bandgap semiconductor (3.45 eV), has emerged as a promising material for radiation detection due to its exceptional radiation tolerance, high thermal stability, and ultrafast scintillation response. This study investigates the energy-dependent scintillation response of bulk and thin GaN crystals to fast neutrons and flash gamma rays. Experiments were conducted at the Los Alamos Neutron Science Center using neutron time-of-flight techniques and a fast-gated intensified CCD camera. GaN crystals were exposed to neutron energies ranging from 0.1 to 400 MeV, including the 14.1 MeV relevant to deuterium–tritium fusion. Results indicate a pronounced gamma-induced scintillation signal with prompt full width-at-half-maximum values of 4.27 ns for thin GaN and 3.60 ns for bulk GaN. Rise times were modeled at 90 ps for thin GaN and 662 ps for bulk GaN, confirming rapid response characteristics. Neutron energy-dependent scintillation was observed, and efficiency per millimeter of material was quantified. Broadband photoluminescence observation revealed emission peaks, which are associated with defect states within the crystal structure. Unlike conventional scintillator materials, GaN offers the unique advantage of integration into semiconductor-based circuits, making it highly suitable for radiation-hard diagnostics in fusion power, nuclear reactors, aerospace, and biomedical applications. These findings demonstrate the viability of GaN as a next-generation integrated scintillation material, paving the way for multi-modal, multi-mode-readout diagnostic platforms in high-radiation environments.
- 1 May 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (5)
Open AccessGallium nitride (GaN) scintillation response to fast neutrons and flash gamma rays and associated broadband photoluminescence
Gallium nitride (GaN), a wide-bandgap semiconductor (3.45 eV), has emerged as a promising material for radiation detection due to its exceptional radiation tolerance, high thermal stability, and ultrafast scintillation response. This study investigates the energy-dependent scintillation response of bulk and thin GaN crystals to fast neutrons and flash gamma rays. Experiments were conducted at the Los Alamos Neutron Science Center using neutron time-of-flight techniques and a fast-gated intensified CCD camera. GaN crystals were exposed to neutron energies ranging from 0.1 to 400 MeV, including the 14.1 MeV relevant to deuterium–tritium fusion. Results indicate a pronounced gamma-induced scintillation signal with prompt full width-at-half-maximum values of 4.27 ns for thin GaN and 3.60 ns for bulk GaN. Rise times were modeled at 90 ps for thin GaN and 662 ps for bulk GaN, confirming rapid response characteristics. Neutron energy-dependent scintillation was observed, and efficiency per millimeter of material was quantified. Broadband photoluminescence observation revealed emission peaks, which are associated with defect states within the crystal structure. Unlike conventional scintillator materials, GaN offers the unique advantage of integration into semiconductor-based circuits, making it highly suitable for radiation-hard diagnostics in fusion power, nuclear reactors, aerospace, and biomedical applications. These findings demonstrate the viability of GaN as a next-generation integrated scintillation material, paving the way for multi-modal, multi-mode-readout diagnostic platforms in high-radiation environments.
- 2 October 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1069
Low Energy Neutron-induced Charged-particle (Z) (LENZ) instrument development with a focus on pulse shape discrimination for low-energy charged particles
- 2 October 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1069
Low Energy Neutron-induced Charged-particle (Z) (LENZ) instrument development with a focus on pulse shape discrimination for low-energy charged particles