I. S. Plotnikov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
I. S. Plotnikov has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
N. I. Bozhko
National Research Centre Kurchatov Institute
5 shared publicationsA. S. Kozhin
Institute for High Energy Physics
4 shared publications- A. V. Kozelov
Institute for High Energy Physics, Protvino, Moscow region 142281, Russia
4 shared publications N. A. Shalanda
National Research Centre Kurchatov Institute
4 shared publicationsR. M. Fakhrutdinov
National Research Centre Kurchatov Institute
4 shared publicationsA. A. Borisov
National Research Centre Kurchatov Institute
3 shared publications
Latest Publications
- 1 January 2017
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 60 (1) , 35-38
The data-acquisition system of a muon tomograph based on on-chamber electronics
The data-acquisition system of a muon tomograph based on the on-chamber electronics is described. Its advantages over the previously used system based on the electronics made to the VME-9U standard...
- 1 January 2017
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 60 (1) , 35-38
The data-acquisition system of a muon tomograph based on on-chamber electronics
The data-acquisition system of a muon tomograph based on the on-chamber electronics is described. Its advantages over the previously used system based on the electronics made to the VME-9U standard...
- 15 November 2016
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 59 (6) , 794-801
The on-chamber electronic system based on an MT-48 module for the triggerless operation mode of the cosmic-muon tomograph
The on-chamber electronic system of a muon tomograph is described. The system is composed of an MT-48 48-channel front-end module and an RMT-48 fan-out module for the multiplication of control...
- 15 November 2016
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 59 (6) , 794-801
The on-chamber electronic system based on an MT-48 module for the triggerless operation mode of the cosmic-muon tomograph
The on-chamber electronic system of a muon tomograph is described. The system is composed of an MT-48 48-channel front-end module and an RMT-48 fan-out module for the multiplication of control...
- 1 July 2014
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 57 (4) , 410-416
A chamber composed of precision Mylar drift tubes
The design of a drift chamber composed of three layers of thin-walled (0.125 mm) precision Mylar tubes is described. Twenty six chambers of this type with areas from 1 × 1 to 2.5 × 2 m2comprising...
- 1 July 2014
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 57 (4) , 410-416
A chamber composed of precision Mylar drift tubes
The design of a drift chamber composed of three layers of thin-walled (0.125 mm) precision Mylar tubes is described. Twenty six chambers of this type with areas from 1 × 1 to 2.5 × 2 m2comprising...
- 1 March 2013
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 56 (2) , 134-139
A precision drift tube with a Mylar body
The design and assembling procedure of a precision drift tube housed in a Mylar pipe are described. The technology for manufacturing drift tube bodies from a 125-μm-thick Mylar film with an aluminum...
- 1 March 2013
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 56 (2) , 134-139
A precision drift tube with a Mylar body
The design and assembling procedure of a precision drift tube housed in a Mylar pipe are described. The technology for manufacturing drift tube bodies from a 125-μm-thick Mylar film with an aluminum...
- 1 March 2013
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 56 (2) , 156-164
A data acquisition and control system in the MISS electronics standard for the detector on drift tubes
A structure of the data acquisition and control system (DAQC) in the MISS electronics standard for a multichannel detector on drift tubes is described. Its special feature is the use of the...
- 1 March 2013
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 56 (2) , 156-164
A data acquisition and control system in the MISS electronics standard for the detector on drift tubes
A structure of the data acquisition and control system (DAQC) in the MISS electronics standard for a multichannel detector on drift tubes is described. Its special feature is the use of the...
- 1 March 2012
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 55 (2) , 151-160
A Muon Tomograph setup with a 3 × 3 m2 area of overlapping
The Muon Tomograph setup with a 3 × 3 m2area of overlapping is described. This setup has been designed to investigate the feasibility of detecting hidden objects with different densities using...
- 1 March 2012
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 55 (2) , 151-160
A Muon Tomograph setup with a 3 × 3 m2 area of overlapping
The Muon Tomograph setup with a 3 × 3 m2area of overlapping is described. This setup has been designed to investigate the feasibility of detecting hidden objects with different densities using...
- 1 October 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10823654,p. 296-298
IHEP (Protvino) 3×3 m2 cosmic ray muon tomograph
Muon tomography, based on the measurement of multiple scattering of cosmic ray muons traversing a volume to be investigated, is an attractive technique for detecting hidden high-Z materials. A cosmic ray muon tomograph with sensitive volume of 3m × 3m × 2.5m has been constructed at IHEP (Protvino) and is under producing first data and results. The description and characteristics of the setup are presented. The tomograph is built of 30 mm drift tubes operating in trigger-less mode. Tubes are filled with an Ar-CO 2 mixture and can operate for about one year without refreshing of the gas-mixture. Specialized track reconstruction, tomographic reconstruction and visualization tools were developed. Image reconstruction examples are presented.
- 1 October 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10823654,p. 296-298
IHEP (Protvino) 3×3 m2 cosmic ray muon tomograph
Muon tomography, based on the measurement of multiple scattering of cosmic ray muons traversing a volume to be investigated, is an attractive technique for detecting hidden high-Z materials. A cosmic ray muon tomograph with sensitive volume of 3m × 3m × 2.5m has been constructed at IHEP (Protvino) and is under producing first data and results. The description and characteristics of the setup are presented. The tomograph is built of 30 mm drift tubes operating in trigger-less mode. Tubes are filled with an Ar-CO 2 mixture and can operate for about one year without refreshing of the gas-mixture. Specialized track reconstruction, tomographic reconstruction and visualization tools were developed. Image reconstruction examples are presented.