SNStephanie J. Nisbet

Stephanie J. Nisbet

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Stephanie J. Nisbet has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Single application of lamellar moisturizers provides significantly increased hydration of the stratum corneum for up to 24 hours in a randomized trial

    by Stephanie J. Nisbet, Peter Dykes, Jane Snatchfold

    Background: Some moisturizing formulations can help restore and maintain the barrier function of the skin.Objectives: This study was designed to assess the hydration potential of three lamellar moisturizers relative to a control (nonlamellar) moisturizer.Methods: Healthy adults aged 18 to 65 years with self‐reported sensitive skin, dry or very dry skin and Corneometry values of ≤40 a.u. on the lower legs, entered this randomized, evaluator‐blind study. Products A and B together with a control product (Control X) were applied to one leg, while Product C and Control Y were applied to the other leg; with an untreated control site in both cases. The primary efficacy variable was the change from baseline in Corneometer assessments at 24 hours (Products A and B) or 12 hours (Product C) postapplication.Results: At all timepoints (n = 30), Products A and B showed higher mean Corneometer readings compared to baseline and changes from baseline were statistically significant when compared to untreated sites. Higher mean readings relative to baseline were seen at sites treated with Control X (smaller magnitude than Product A and B) and with Product C. These changes were significant compared to the untreated site at 30 minutes and 2 hours (Control X), and at 30 minutes and 12 hours (Product C). Additionally, Control Y increased significantly at 12 hours.Conclusion: A single application of a lamellar moisturizer significantly increased hydration of the stratum corneum for up to 24 hours (Products A and B) or 12 hours (Product C).


  • Open Access

    Clinical and in vitro evaluation of new anti‐redness cosmetic products in subjects with winter xerosis and sensitive skin

    by S. J. Nisbet, D. Targett, A. V. Rawlings, K. Qian, X. Wang, C. B. Lin, M. A. Thompson, P. A. Bulsara, D. J. Moore

    Objective: To demonstrate the in vitro activities of panthenol, palmitoylethanolamide (PEA), and niacinamide (NAM) and determine the biophysical properties, clinical safety, tolerability together with efficacy of two developmental anti‐redness (AR) formulations containing these ingredients, in alleviating facial redness associated with winter xerosis in healthy volunteers with sensitive skin.Methods: The anti‐inflammatory and skin protective properties of panthenol, PEA and NAM were evaluated in vitro. The physical properties of the AR formulations were analysed using measurement of water vapour transport rate (WVTR) and infrared spectroscopy. Clinical studies were performed between the months of December and April (2014–2015) with efficacy assessed during the winter. Facial redness, irritation, sensitization potential, photo‐irritation, and photo‐sensitization were evaluated. Self‐assessed adverse reactions were reported in diaries of use.Results: Panthenol and PEA reduced prostaglandin E2, interleukin‐6, and thymic stromal lymphopoietin levels in vitro, while NAM induced nicotinamide adenine dinucleotide (NAD) levels and the keratinocyte differentiation markers: filaggrin (2‐fold increase, P < 0.001), loricrin (2‐fold increase, P < 0.05), involucrin (2 fold increase, P < 0.001) & peroxisomal proliferator activated receptor‐alpha (1.5 fold increase, P < 0.05). The two AR products exhibited low WVTR vs. no treatment (P < 0.001) and displayed an ordered lipid structure. The day cream formulation protected against ultraviolet B radiation in vitro. A total of 382 participants were included in clinical studies which showed the AR formulations significantly improved facial redness associated with winter xerosis (Day 29 mean change from baseline: AR day cream 0.77 (P < 0.001); AR serum 0.67 (P < 0.001)). No irritation, sensitization, photo‐irritation, photo‐sensitization or product‐related adverse reactions were observed or reported in the clinical studies.Conclusion: The new products significantly improved skin redness associated with winter xerosis in participants with self‐perceived sensitive skin. Both products were well tolerated with a suitable safety profile for topical use in subjects with sensitive skin.


  • Open Access

    Cosmetic benefit of a biomimetic lamellar cream formulation on barrier function or the appearance of fine lines and wrinkles in randomized proof‐of‐concept clinical studies

    by Stephanie Nisbet, Harish Mahalingam, Christoph F. Gfeller, Emma Biggs, Siobhan Lucas, Michael Thompson, Matthew R. Cargill, David Moore, Stephan Bielfeldt

    Objective: Two studies were designed to evaluate the potential cosmetic benefit of a biomimetic, niacinamide‐containing moisturizing cream for the first time in humans.Methods: In both studies, healthy women were randomized to use two treatments, one for the left side of the body and one for the right, from three options: the test cream, a positive control or no treatment (use of standard cleanser only). Treatments were applied twice daily for 4 weeks to the face and forearms (Study 1) or the face only (Study 2). Instrumental and clinical skin assessments were performed by trained technicians. Study 1 involved tape stripping and a 5‐day no‐treatment (‘regression’) period at the end of the 4 weeks. Independent lay graders were asked to grade the skin texture of subjects in Study 2 from high‐resolution photographs.Results: In Study 1 (n = 66), the test cream significantly decreased the transepidermal water loss (TEWL) values on the forearm, and in the cheek area of the face, relative to baseline and compared to no treatment, and increased skin Corneometer values. The improvements were partially retained during a subsequent 5‐day period of no treatment. Increases in TEWL values on skin subjected to tape stripping were significantly lower after 4 weeks of using the test cream compared to no treatment. In Study 2 (n = 72 subjects with visible signs of ageing), there was a favourable trend in the change from baseline of a skin roughness parameter, Ra, for the test cream compared to no treatment. There were statistically significant improvements in the Fitzpatrick wrinkle score compared to no treatment, decreases in TEWL and increased Corneometer values and Cutometer values (R5 elasticity parameter). Grading of high‐resolution images failed to detect the improvements in skin texture (defined as pores, smoothness and unevenness) for the test cream vs. no treatment. No treatment‐related serious or severe adverse events were reported.Conclusion: Twice daily application of the test cream over 4 weeks had beneficial effects on skin barrier function, moisturization, wrinkle dimensions and elasticity compared to no treatment. These studies provide proof‐of‐concept evidence and highlight the cosmetic benefit of the biomimetic lamellar cream formulation. Study registration: NCT03216265, NCT03180645.


  • Open Access

    Absence of human skin irritation and allergenic potential after repeated patch applications of a lamellar moisturizer

    by Stephanie J Nisbet

    Summary: Background: New cosmetic products should undergo clinical evaluation for skin sensitization potential.Objectives: To assess the irritation and sensitization potential of a moisturizer containing lamellar structured lipids after repeated patch application in humans, using human repeated insult patch test methodology.Methods: This 6‐week, single‐center, open‐label study compared a lamellar moisturizer with negative saline control in human subjects aged 18‐70 years and skin phototype (Fitzpatrick) classification I–IV. During an initial induction phase, semi‐occlusive multi‐test patches were applied to the skin of participants’ backs three times per week for 3 consecutive weeks; clinical assessments were performed per International Contact Dermatitis Research Group criteria. Participants subsequently underwent a challenge phase, where a new patch was applied to a contact‐naïve area of the skin to assess sensitization to the moisturizer.Results: The study commenced with 233 voluntary participants, 214 of whom completed the study and underwent the final dermatological assessment. Most participants (232/233; 99.6%) demonstrated negative patch test results. One participant had a positive reaction at the lamellar moisturizer application site, with visible erythema and edema (classified as an adverse event [AE]); however, this reaction was observed 24 hours after a reaction to another product in the patch test panel (a prototype cleanser). Importantly, no skin reactions were detected during the challenge phase. Two participants had AEs of mild contact dermatitis in the area of patch adhesive application during the induction phase. No serious AEs occurred during the study.Conclusions: These findings suggest that the lamellar moisturizer has low irritant and allergenic potential.


  • Open Access

    Skin acceptability of a cosmetic moisturizer formulation in female subjects with sensitive skin

    by Stephanie J Nisbet

    Purpose: This 3-week, open-label, noncomparative clinical study evaluated the skin acceptability of a cosmetic moisturizer in subjects with sensitive skin, by monitoring adverse events (AEs) and cutaneous discomfort related to normal usage. Materials and methods: Female subjects aged between 18–60 years, with Fitzpatrick phototype classification I–IV and sensitive skin, verified by a positive reaction on the stinging test at screening, were included. Subjects applied the moisturizer to their face and body twice daily for 21±2 days at home and recorded study product usage and feelings of cutaneous discomfort (eg, dryness, prickling, stinging, and itching) in a diary; any AEs were reported to the clinic. At study end, skin acceptability of the moisturizer was investigator-assessed based on the nature of AEs and subjects’ self-reported feelings of discomfort, and by clinical evaluation of skin reactions in the area of moisturizer application (appearance of erythema, formation of edema, and skin desquamation; scored according to an adapted Draize and Kligman scale). Only subjects with a treatment compliance of ≥80% were included in the final analysis. Results: In total, 35 subjects initiated and completed the study; all were compliant to the minimum study product usage. Per investigator clinical dermatological assessment at study end, none of the 35 subjects had skin reactions in the area of moisturizer application and there were no reported AEs. One subject reported sensations of mild prickling and itching immediately after applying the moisturizer (not classified as AEs), which spontaneously remitted after complete absorption of the product and were noted only in exposed areas. These events were considered by the investigator as being possibly/probably related to the use of study product; however, no clinical signs of skin reaction were observed in the exposed areas. Conclusion: This cosmetic moisturizer appears generally well tolerated and suitable for topical use in subjects with sensitive skin.


    • 1 January 2018
      • Vol. 69  (1) , 1-8

    A Prototype Lip Balm: Summary of Three Dermatological Studies Demonstrating Safety and Acceptability for Sensitive Skin

    by Stephanie Nisbet

    Synopsis Data were generated from three studies to assess the tolerability and acceptability of a prototype cosmetic lip balm. Dermatological assessments of topical compatibility (primary and cumulative irritability and sensitization), photoirritant and topical photosensitizer potential, and acceptability for safe use of a prototype cosmetic lip balm on sensitive skin are summarized. In Study 1, the product was applied to the volunteers' backs under a semiocclusive patch followed by patch removal/reapplication over 6 weeks to assess the irritant and allergic potential of the product. Dermatological assessments were performed at the beginning and end of the study or when there was evidence of positivity or adverse event. Study 2 was conducted by applying the product to the volunteers' backs under a semiocclusive patch, followed by patch removal/reapplication and irradiation of the test area with ultraviolet A (UVA) radiation at various intervals over 5 weeks. Dermatological assessments were performed to assess the product's role in the induction of photoirritancy and photosensitization. Clinical and subjective assessments for acceptability were obtained during Study 3 in volunteers with a diagnosis of sensitive skin and those who used the product as per instructions for use during the study period. The data generated from the three studies demonstrated no evidence of primary or cumulative dermal irritation or of dermal sensitization. In addition, no photoirritation potential or photosensitization potential was observed. As assessed by dermatologic monitoring and subject diary entries, the prototype lip balm did not cause irritation or sensitization reactions wdien used for 28 days in volunteers with a diagnosis of sensitive skin. Based on these findings, the prototype lip balm can be considered suitable for use for people with sensitive skin.