Christian-George Bénar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Christian-George Bénar has a total of 295 co-authors. Here are the top co-authors by number of shared publications:
Fabrice Bartolomei
INSERM, INS, Institut de Neurosciences Des Systèmes, Aix Marseille University, 13005 Marseille, France; APHM, Timone Hospital, Epileptology and Cerebral Rhythmology, 13005 Marseille, France
21 shared publicationsJean-Michel Badier
18 shared publications- Fabrice Bartolomei
Epileptology and Cerebral Rhythmology, APHM, Timone Hospital, Marseille, France
15 shared publications Samuel Medina Villalon
INSERM, INS, Institut de Neurosciences Des Systèmes, Aix Marseille University, 13005 Marseille, France; APHM, Timone Hospital, Epileptology and Cerebral Rhythmology, 13005 Marseille, France
12 shared publications- Francesca Pizzo
Aix Marseille Univ, INSERM, INS, Inst Neurosci Syst, Marseille, France
11 shared publications - Patrick Chauvel
Epilepsy Center Neurological Institute, Cleveland Clinic Cleveland Ohio USA
10 shared publications
Latest Publications
- 19 September 2026
- Published by Elsevier in Clinical Neurophysiology
- Vol. 192, 2112409
Revealing hidden epileptic networks beyond SEEG sampling using simultaneous MEG and SEEG: a case study
- 19 September 2026
- Published by Elsevier in Clinical Neurophysiology
- Vol. 192, 2112409
Revealing hidden epileptic networks beyond SEEG sampling using simultaneous MEG and SEEG: a case study
- Open Access
- 19 August 2026
- Published by Elsevier in Neuroscience Informatics
- Vol. 6 (4)
Identifying the irritative network in magnetoencephalography based on clustering and independent component analysis
- 19 August 2026
- Published by Elsevier in Neuroscience Informatics
- Vol. 6 (4)
Open AccessIdentifying the irritative network in magnetoencephalography based on clustering and independent component analysis
- Open Access
- 13 July 2026
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
What Do the Intracerebral Electrodes See and Do Not See?
Summary: Stereoelectroencephalography (SEEG) is a powerful technique for delineating the epileptogenic zone network in patients with drug-resistant epilepsy, providing direct access to both superficial and deep brain structures. However, its clinical value depends critically on the accurate interpretation of the recorded signals—which requires clear understanding of what we are actually recording, and what we are not. In this review, we examine the fundamental biophysical principles underlying SEEG signal generation, mainly the anatomical organization of brain structures and their distance from SEEG contacts. We address the types of epileptic patterns that SEEG can detect and how their interpretation depends on the referencing montage. Building on these concepts, we discuss the types of activity that may be missed or misrepresented. Finally, we explore emerging strategies to extend the field of view of SEEG electrodes. This review is intended both as an introduction for newcomers to the origin of SEEG signals and as an update for experienced users, reaffirming key concepts and presenting new methodological perspectives.
- 13 July 2026
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
Open AccessWhat Do the Intracerebral Electrodes See and Do Not See?
Summary: Stereoelectroencephalography (SEEG) is a powerful technique for delineating the epileptogenic zone network in patients with drug-resistant epilepsy, providing direct access to both superficial and deep brain structures. However, its clinical value depends critically on the accurate interpretation of the recorded signals—which requires clear understanding of what we are actually recording, and what we are not. In this review, we examine the fundamental biophysical principles underlying SEEG signal generation, mainly the anatomical organization of brain structures and their distance from SEEG contacts. We address the types of epileptic patterns that SEEG can detect and how their interpretation depends on the referencing montage. Building on these concepts, we discuss the types of activity that may be missed or misrepresented. Finally, we explore emerging strategies to extend the field of view of SEEG electrodes. This review is intended both as an introduction for newcomers to the origin of SEEG signals and as an update for experienced users, reaffirming key concepts and presenting new methodological perspectives.
- Open Access
- 9 July 2026
- Published by Springer Nature in Research Square
Sustained pulvinar activity and early thalamic responses reveal dual temporal dynamics of human attention
The thalamus is increasingly recognized as a hub in cortico-subcortical networks supporting cognition, but its temporal contribution to higher-order processing remains unclear. We recorded intracranial thalamic activity during a visual oddball task in 54 patients with drug-resistant focal epilepsy undergoing stereoelectroencephalography with thalamic implantation including the pulvinar. We identified two distinct response components: an early transient response in the P300 time range and a later sustained response emerging after ~ 500 ms with plateau-like dynamics. In the pulvinar, sustained responses dominated (67%), whereas early P300-like responses were less frequent (18%). The dissociation suggests distinct thalamic roles in rapid stimulus detection and sustained activity maintenance. We propose that the late pulvinar-dominant activity reflects prolonged stabilization of task-relevant representations and recurrent processing supporting sustained attentional states. These findings provide intracranial evidence for temporally distinct cognitive dynamics within the human thalamus and highlight a specific role of the pulvinar in sustained cognition.
- 9 July 2026
- Published by Springer Nature in Research Square
Open AccessSustained pulvinar activity and early thalamic responses reveal dual temporal dynamics of human attention
The thalamus is increasingly recognized as a hub in cortico-subcortical networks supporting cognition, but its temporal contribution to higher-order processing remains unclear. We recorded intracranial thalamic activity during a visual oddball task in 54 patients with drug-resistant focal epilepsy undergoing stereoelectroencephalography with thalamic implantation including the pulvinar. We identified two distinct response components: an early transient response in the P300 time range and a later sustained response emerging after ~ 500 ms with plateau-like dynamics. In the pulvinar, sustained responses dominated (67%), whereas early P300-like responses were less frequent (18%). The dissociation suggests distinct thalamic roles in rapid stimulus detection and sustained activity maintenance. We propose that the late pulvinar-dominant activity reflects prolonged stabilization of task-relevant representations and recurrent processing supporting sustained attentional states. These findings provide intracranial evidence for temporally distinct cognitive dynamics within the human thalamus and highlight a specific role of the pulvinar in sustained cognition.
- Open Access
- 4 June 2026
- Published by The Open Journal in Journal of Open Source Software
- Vol. 11 (122)
sEEG-Suite: An Interactive Pipeline for Semi-Automated Contact Localization and Anatomical Labeling with Brainstorm
- 4 June 2026
- Published by The Open Journal in Journal of Open Source Software
- Vol. 11 (122)
Open AccesssEEG-Suite: An Interactive Pipeline for Semi-Automated Contact Localization and Anatomical Labeling with Brainstorm
- 7 November 2025
- Published by Springer Nature in Journal of Neurology
- Vol. 272 (12) , 1-14
Performance of blind source separation in localizing seizure onset from routine scalp-EEG
Objective Blind source separation (BSS), decomposing signals into mixed sources, remains underexplored in ictal source imaging. We evaluated its ability to extract ictal components localizing the seizure onset zone (SOZ) using routine low-density scalp EEG across multiple settings. Methods We analyzed 20 seizures from ten patients with stereo-EEG-defined SOZs, all seizure-free after surgery or RF-thermocoagulation. BSS was computed over 10-, 30-, and 300-s periods preceding clinically and EEG-defined seizure onsets, using FastICA, InfoMax, and SOBI algorithms. Components were visually categorized as ictal or non-ictal. For each computation, the clearest ictal component was labeled best-of-BSS; one per seizure was further labeled unique when enhancing the ictal discharge. We estimated distances between components’ localization and the SOZ and assessed sublobar concordance. Results Across 360 BSS computations (8164 components), sublobar SOZ localization occurred in 38.5% of ictal components (mean distance: 44.4 mm), 48.2% of best-of-BSS (36.8 mm), 56.7% of unique (28.9 mm), versus 17.9% of non-ictal components (62.9 mm). InfoMax computed on 300-s periods preceding clinical onset achieved the highest F-scores. Conclusions Under these settings, best-of-BSS components localized the SOZ in 13/20 seizures (8/10 patients), with a median distance of 29.9 mm. Significance InfoMax algorithm incorporating longer time windows improves SOZ localization from routine scalp-EEG.
- 7 November 2025
- Published by Springer Nature in Journal of Neurology
- Vol. 272 (12) , 1-14
Performance of blind source separation in localizing seizure onset from routine scalp-EEG
Objective Blind source separation (BSS), decomposing signals into mixed sources, remains underexplored in ictal source imaging. We evaluated its ability to extract ictal components localizing the seizure onset zone (SOZ) using routine low-density scalp EEG across multiple settings. Methods We analyzed 20 seizures from ten patients with stereo-EEG-defined SOZs, all seizure-free after surgery or RF-thermocoagulation. BSS was computed over 10-, 30-, and 300-s periods preceding clinically and EEG-defined seizure onsets, using FastICA, InfoMax, and SOBI algorithms. Components were visually categorized as ictal or non-ictal. For each computation, the clearest ictal component was labeled best-of-BSS; one per seizure was further labeled unique when enhancing the ictal discharge. We estimated distances between components’ localization and the SOZ and assessed sublobar concordance. Results Across 360 BSS computations (8164 components), sublobar SOZ localization occurred in 38.5% of ictal components (mean distance: 44.4 mm), 48.2% of best-of-BSS (36.8 mm), 56.7% of unique (28.9 mm), versus 17.9% of non-ictal components (62.9 mm). InfoMax computed on 300-s periods preceding clinical onset achieved the highest F-scores. Conclusions Under these settings, best-of-BSS components localized the SOZ in 13/20 seizures (8/10 patients), with a median distance of 29.9 mm. Significance InfoMax algorithm incorporating longer time windows improves SOZ localization from routine scalp-EEG.
- 4 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (6) , 2313-2325
Combining Spatial Wavelets and Sparse Bayesian Learning for Extended Brain Sources Reconstruction
Objective: The accurate reconstruction of extended cortical activity from M/EEG data is a difficult, ill-conditioned problem. This work proposes to model distributed sources through spectral graph wavelets on the cortical surface, and addresses resulting numerical optimization problems. The objective is accurate localization, especially for extended sources, together with quantitatively relevant amplitude and time course. Approach: Unknown sources are expanded on a system of spectral graph wavelets (SGW) defined on the cortical surface. Unknown wavelet coefficients are estimated using either variational or Bayesian formulations, involving priors that favor extended sources through sparsity in the wavelet domain: sparsity-inducing regularization, or sparse Bayesian learning (SBL). These approaches are tested and compared with concurrent approaches on real (open-access) data and numerical simulations. The quality of reconstructions is assessed using complementary metrics. Results: SGW-based approaches are able to identify accurately extended sources. The combination with SBL is particularly attractive, as it doesn't involve hyperparameter tuning and automatically adapts to the signal to noise ratio (SNR). It yields accurate and robust results with respect to all considered metrics, and performs remarkably well in terms of depth bias. Conclusion: This paper demonstrates the usefulness of spectral graph cortical wavelets for reconstructing cortical activity from M/EEG data, especially when coupling spatial wavelets with SBL. Significance: Being able to identify localization, depth, amplitude and time course of brain activity from M/EEG data is important in clinical applications such as epilepsy, as it can improve the detection of potential sources of seizures.
- 4 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (6) , 2313-2325
Combining Spatial Wavelets and Sparse Bayesian Learning for Extended Brain Sources Reconstruction
Objective: The accurate reconstruction of extended cortical activity from M/EEG data is a difficult, ill-conditioned problem. This work proposes to model distributed sources through spectral graph wavelets on the cortical surface, and addresses resulting numerical optimization problems. The objective is accurate localization, especially for extended sources, together with quantitatively relevant amplitude and time course. Approach: Unknown sources are expanded on a system of spectral graph wavelets (SGW) defined on the cortical surface. Unknown wavelet coefficients are estimated using either variational or Bayesian formulations, involving priors that favor extended sources through sparsity in the wavelet domain: sparsity-inducing regularization, or sparse Bayesian learning (SBL). These approaches are tested and compared with concurrent approaches on real (open-access) data and numerical simulations. The quality of reconstructions is assessed using complementary metrics. Results: SGW-based approaches are able to identify accurately extended sources. The combination with SBL is particularly attractive, as it doesn't involve hyperparameter tuning and automatically adapts to the signal to noise ratio (SNR). It yields accurate and robust results with respect to all considered metrics, and performs remarkably well in terms of depth bias. Conclusion: This paper demonstrates the usefulness of spectral graph cortical wavelets for reconstructing cortical activity from M/EEG data, especially when coupling spatial wavelets with SBL. Significance: Being able to identify localization, depth, amplitude and time course of brain activity from M/EEG data is important in clinical applications such as epilepsy, as it can improve the detection of potential sources of seizures.
- Open Access
- 9 October 2025
- Published by Elsevier in Clinical Neurophysiology
- Vol. 180, 2111377
Classification of magnetoencephalographic independent components in epilepsy by machine learning
- 9 October 2025
- Published by Elsevier in Clinical Neurophysiology
- Vol. 180, 2111377
Open AccessClassification of magnetoencephalographic independent components in epilepsy by machine learning
- 27 September 2025
- Published by Springer Nature in Brain Topography
- Vol. 38 (6) , 1-30
Pre-attentive Pitch Processing of Harmonic Complex Sounds at Sensor and Source Levels: Comparing Simultaneously Recorded EEG and MEG Data
Electroencephalography (EEG) and magnetoencephalography (MEG), two of the most widely used tools for studying human brain dynamics, are thought to have varying spatial resolutions. Here, we simultaneously recorded EEG and MEG data from 14 participants to directly compare their sensitivities — at both the sensor and source levels — to the auditory Mismatch Negativity (MMN in EEG and MMNm in MEG) elicited by pitch deviants. At the sensor level, we observed that negative components emerged in early (100–190 ms) and late (260–420 ms) latency windows. These responses displayed a fronto-central distribution in EEG and a centro-parietal distribution in MEG. MEG also yielded larger effect sizes than EEG, likely reflecting differences in signal-to-noise ratio between MEG and EEG. At the source level, our findings support the involvement of a fronto-temporal auditory MMN network. Both EEG and MEG identified generators in the superior temporal gyrus, Heschl’s gyrus, interior frontal gyrus, and insular regions. Notably, EEG source localization revealed additional generators in the left superior temporal sulcus not detected by MEG, whereas MEG identified late components generators in the right hemisphere that were not observed with EEG. Taken together, these results suggest that EEG and MEG may provide complementary perspectives on auditory processing. However, given the inherent complexity of comparing data acquired with different methodologies and the limited sample size, our conclusions should be regarded as preliminary.
- 27 September 2025
- Published by Springer Nature in Brain Topography
- Vol. 38 (6) , 1-30
Pre-attentive Pitch Processing of Harmonic Complex Sounds at Sensor and Source Levels: Comparing Simultaneously Recorded EEG and MEG Data
Electroencephalography (EEG) and magnetoencephalography (MEG), two of the most widely used tools for studying human brain dynamics, are thought to have varying spatial resolutions. Here, we simultaneously recorded EEG and MEG data from 14 participants to directly compare their sensitivities — at both the sensor and source levels — to the auditory Mismatch Negativity (MMN in EEG and MMNm in MEG) elicited by pitch deviants. At the sensor level, we observed that negative components emerged in early (100–190 ms) and late (260–420 ms) latency windows. These responses displayed a fronto-central distribution in EEG and a centro-parietal distribution in MEG. MEG also yielded larger effect sizes than EEG, likely reflecting differences in signal-to-noise ratio between MEG and EEG. At the source level, our findings support the involvement of a fronto-temporal auditory MMN network. Both EEG and MEG identified generators in the superior temporal gyrus, Heschl’s gyrus, interior frontal gyrus, and insular regions. Notably, EEG source localization revealed additional generators in the left superior temporal sulcus not detected by MEG, whereas MEG identified late components generators in the right hemisphere that were not observed with EEG. Taken together, these results suggest that EEG and MEG may provide complementary perspectives on auditory processing. However, given the inherent complexity of comparing data acquired with different methodologies and the limited sample size, our conclusions should be regarded as preliminary.
- Open Access
sEEG-Suite: An Interactive Pipeline for Semi-Automated Contact Localization and Anatomical Labeling with Brainstorm
Summary: Stereoelectroencephalography (sEEG) is a critical tool for mapping epileptic networks in patients with drug-resistant epilepsy. Accurate localization and labeling of sEEG contacts are essential for identifying the seizure onset zone (SOZ) and ensuring optimal resective surgery. Traditional methods for localizing and labeling sEEG contacts rely on manual processing, which is prone to human error and variability. To address these challenges, we developed and integrated a semi-automatic sEEG contact localization and labeling pipeline within Brainstorm 1 , an open-source software platform for multimodal brain imaging analysis 2–8 , widely adopted in the neuroscience community with over 50,000 registered users and an active online user forum . The software has been supported by the National Institute of Health (NIH) for over two decades. The pipeline presented in this paper performs three key steps: (1) import and apply rigid co-registration of post-implantation Computed Tomography (CT) or post-CT with pre-implantation Magnetic Resonance Imaging (pre-MRI), (2) post-CT image segmentation and semi-automatic detection of sEEG contacts using GARDEL 9 , which has been integrated as a Brainstorm plugin, and (3) automatic anatomical labeling of contacts using standard and commonly used brain anatomy templates and atlases. Integrating this pipeline into Brainstorm brings the best of both worlds: GARDEL’s automation and Brainstorm’s multimodal data compatibility, and rich library of visualization and advanced analysis tools at both sensor and source level 6 . This sEEG-Suite tool facilitates reproducible research, supports clinical workflows, and accelerates sEEG-based investigations of invasive brain recordings.
Open AccesssEEG-Suite: An Interactive Pipeline for Semi-Automated Contact Localization and Anatomical Labeling with Brainstorm
Summary: Stereoelectroencephalography (sEEG) is a critical tool for mapping epileptic networks in patients with drug-resistant epilepsy. Accurate localization and labeling of sEEG contacts are essential for identifying the seizure onset zone (SOZ) and ensuring optimal resective surgery. Traditional methods for localizing and labeling sEEG contacts rely on manual processing, which is prone to human error and variability. To address these challenges, we developed and integrated a semi-automatic sEEG contact localization and labeling pipeline within Brainstorm 1 , an open-source software platform for multimodal brain imaging analysis 2–8 , widely adopted in the neuroscience community with over 50,000 registered users and an active online user forum . The software has been supported by the National Institute of Health (NIH) for over two decades. The pipeline presented in this paper performs three key steps: (1) import and apply rigid co-registration of post-implantation Computed Tomography (CT) or post-CT with pre-implantation Magnetic Resonance Imaging (pre-MRI), (2) post-CT image segmentation and semi-automatic detection of sEEG contacts using GARDEL 9 , which has been integrated as a Brainstorm plugin, and (3) automatic anatomical labeling of contacts using standard and commonly used brain anatomy templates and atlases. Integrating this pipeline into Brainstorm brings the best of both worlds: GARDEL’s automation and Brainstorm’s multimodal data compatibility, and rich library of visualization and advanced analysis tools at both sensor and source level 6 . This sEEG-Suite tool facilitates reproducible research, supports clinical workflows, and accelerates sEEG-based investigations of invasive brain recordings.