JGJulian Guerrero

Julian Guerrero

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Julian Guerrero has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    P-575 Follicle-stimulating hormone receptor genotype and its influence on the results of ovarian stimulation using corifollitropin alfa

    by M Hortal Foronda, A Cascales, J.A Ortiz, B Lledo, J Guerrero, A Bernabeu, R Bernabeu

    Study question: Does the follicle-stimulating hormone receptor (FSHR) genotype influence the results of the ovarian stimulation treatment using corifollitropin alfa? Summary answer: The use of collifolitropin alfa in SS genotype patients appears to be associated with the obtention of a lower number of oocytes and MII. What is known already: Previous studies suggest that FSH receptor polymorphism in position 680 influences the response to ovarian stimulation: patients with SS genotype perform better with urinary FSH and need a higher dose of FSH to obtain similar results to the SN and NN genotypes. These differences could be explained by the longer half-life of urinary gonadotropins, which might compensate for the lower affinity of the receptor in SS genotype patients. Our aim was to elucidate whether corifollitropin alfa, a long-acting recombinant FSH, has the same impact with respect to FSH receptor genotypes as recombinant FSH used habitually. Study design, size, duration: One hundred and fifty-two egg donors were included in a retrospective cohort study between September 2019 and September 2020. In 80 of them, ovarian stimulation treatment was carried out using a single dose of Elonva 150 micrograms (Group 1). In 72 of them, in addition to the 150 microgram dose of Elonva, stimulation was continued with a daily dose of Puregon 225 UI from the eighth day of controlled ovarian stimulation (Group 2). Participants/materials, setting, methods: To genotype the 680 position of the FSH receptor, a real-time PCR for allelic discrimination was carried out using StepOnePlus™ Real-Time PCR System (Applied Biosystems™). Linear regression analysis was performed to study the differences between the groups doing a correction for the variables anti-müllerian hormone, age and BMI. The statistical analysis was made with Software Statistical Product and Service Solutions, version 20.0 (SPSS, Chicago, IL, EE.UU.). Main results and the role of chance: Regarding the whole set of patients, the results of ovarian stimulation using corifollitropin alfa are better in egg donors with SN and NN genotypes compared to those with SS genotype. Statistically significant differences were found in the number of retrieved oocytes (15.78 versus 10.83; p = 0.007) and retrieved MII (12.34 versus 9.00; p = 0.026). There were no statistically significant differences between both groups of genotypes (SN-NN versus SS) in terms of age (24.04 versus 26.44; p = 0.514), BMI (22.22 versus 22.83; p = 0.781), anti-müllerian hormone levels (26.40 versus, 23.58; p = 0.495), antral follicle count (15.57 versus 14.97; p = 0.567) and the number of previous ovarian stimulations (2.71 versus 2.53; p = 0.812). Studying both treatment groups separately, in Group 2, we find significant differences in the number of retrieved oocytes (17.55 versus 13.06, p = 0.012) and retrieved MII (14.25 versus 11.39; p = 0.031), between SN-NN versus SS, respectively. On the other hand, in Group 1, we observe a trend towards statistical significance in the number of retrieved oocytes (13.83 versus 7.50, p = 0.089) and retrieved MII (10.24 versus 5.42; p = 0.120) comparing the same groups of genotypes. Limitations, reasons for caution: The group of egg donors with the SS genotype barely represents 20% of the donors included in the study. This percentage is similar to its prevalence in the general population, so it is necessary to have a large sample size to be able to carry out studies regarding this genotype. Wider implications of the findings: Despite the fact that corifollitropin alfa has a longer half-life, the results of SS patients do not match the rest of genotypes, so other factors must influence. Therefore, it would be advisable to genotype patients for 680 position of FSHR in order not to treat SS patients with this gonadotropin. Trial registration number: -

  • Open Access

    O-099 The use of cumulus cells (CCs) to select spermatozoa for intracytoplasmic sperm injection improves blastocyst development and quality

    by L Marti, J Ten, M Herreros, N Diaz, A Rodriguez-Arnedo, J Guerrero, J.A Ortiz, A Bernabeu, R Bernabeu

    Study question: Is there a role for sperm selection based on the capacity to pass through cumulus oophorous column in improving the laboratory outcomes in ICSI cycles? Summary answer: A higher rate of blastocyst formation and quality are obtained with the use of CCs to select spermatozoa for ICSI compared to conventional density gradients. What is known already: The sperm selection for ICSI is an operator-dependent procedure based on sperm morphology and motility. ICSI bypasses all natural barriers of sperm selection, which may impact embryo development. During natural fertilization, only the spermatozoa that pass-through cumulus cells will have the chance to fertilize the egg. Spermatozoa capable of traverse COCs have better morphology, higher chromatin integrity and greater acrosomal reaction. Hyaluronic acid is an important component of these cells and plays a key role in the selection of spermatozoa with intact DNA. However, there is scarce data regarding this selection method for ICSI on the development of the embryo. Study design, size, duration: This is a prospective randomized sibling oocyte pilot study (February-December 2021). A total of 996 metaphase II (MII) oocytes were randomized into two groups. In the control group (Group 0, n = 489 MII), ICSI was performed with sperm selected by conventional density gradients. In the study group (Group 1, n = 507 MII) the oocytes were microinjected with sperm selected through CCs. The main outcome was blastocyst formation rate and quality. Reproductive results were analyzed as secondary outcomes. Participants/materials, setting, methods: Ninety-eight couples undergoing ICSI (private center) with ≥6 fresh own MII obtained after ovarian stimulation, embryo culture until blastocyst stage and ejaculated sperm samples were included in the study. All seminal samples were processed using density gradients and those in the study group were additionally passed through CCs (the patient's own CCs were used in all cases). Fertilization and day 5 blastocyst formation rates were assessed. Embryo quality was scored according to Gardner's criteria. Main results and the role of chance: Data was similar with regards to cause of infertility, maternal age (36.47 vs 36.63 y.o.), sperm count (60.53 vs 58.25 mill/ml) and progressive motility (57.45 vs 57.50%) between group 0 vs 1, respectively. Fertilization rate was similar between groups (74.0% vs 78.7%; p = 0.419. Group 0 vs 1, respectively). However, the blastocyst formation rate was significantly higher in the study group compared to control (70.9% vs 60.1%; p = 0.002). In addition, high-quality blastocyst rate was significantly higher in the CCs compared to the control group (49.6% vs 38.5%; p = 0.003). After the analysis of 145 treatments (131 frozen vs 14 fresh transfers) the cumulative clinical pregnancy rate in the study group was 47.2%, higher than in the control group (32.1%), but without reaching statistical difference (p = 0.07). Limitations, reasons for caution: This is an exploratory study, aimed to evaluate the effectiveness of CCs as a more “physiologic” selection of spermatozoa for ICSI treatments in terms of laboratory outcomes (blastocyst formation rate and quality). Albeit not reaching statistical significance, the higher cumulative pregnancy rate in the study group seems clinically relevant. Wider implications of the findings: Our results suggest that CCs can select more competent sperm for ICSI. This “physiologic-resembling”, operator-independent selection method has the potential of increasing pregnancy outcomes in ICSI cycles, pending of confirmation in larger studies including cumulative embryo-transfer cycles. Trial registration number: NA


  • Deep venous thrombosis identification from analysis of ultrasound data

    by Julian Guerrero, James A. McEwen, Bassam A. Masri, Savvakis Nicolaou, Septimiu E. Salcudean

    The purpose of this research was to determine whether combined ultrasound- and sensor-based compressibility and augmented blood flow measures yielded better results for DVT detection than for the individual measures alone. Twenty-six limbs from 19 patients were scanned using a sensorized ultrasound DVT screening system, and compressibility and flow measures were obtained at 125 locations. Results from conventional compression ultrasound examination were used as gold standard, with seven vessels (four patients) positive for DVT. A classification approach was used to combine the individual DVT measures per vessel and generate an optimal feature for every possible combination of individual measures. Sensitivity and specificity were calculated for the individual measures and for all combined measures, as was a usefulness criteria \(J\) for measuring class separability. Seven optimal combined features were found with 100 % sensitivity and 100 % specificity, with the best combined feature having a \(J\) value over two orders of magnitude greater than the best individual DVT measure. The proposed approach for DVT detection combines different aspects of thrombus detection in a novel way generating a quantifiable measure and outperforms any of the individual measures when used independently. All of the combined measures included the flow measure as well as the slope compressibility measure, which uses the magnitude of the force applied by the ultrasound probe, suggesting that these measurements provide important information when characterizing DVT.


  • Open Access

    Integrating SOMs and a Bayesian Classifier for Segmenting Diseased Plants in Uncontrolled Environments

    by Deny Lizbeth Hernández-Rabadán, Fernando Ramos-Quintana, Julian Guerrero Juk

    This work presents a methodology that integrates a nonsupervised learning approach (self-organizing map (SOM)) and a supervised one (a Bayesian classifier) for segmenting diseased plants that grow in uncontrolled environments such as greenhouses, wherein the lack of control of illumination and presence of background bring about serious drawbacks. During the training phase two SOMs are used: one that creates color groups of images, which are classified into two groups usingK-means and labeled as vegetation and nonvegetation by using rules, and a second SOM that corrects classification errors made by the first SOM. Two color histograms are generated from the two color classes and used to estimate the conditional probabilities of the Bayesian classifier. During the testing phase an input image is segmented by the Bayesian classifier and then it is converted into a binary image, wherein contours are extracted and analyzed to recover diseased areas that were incorrectly classified as nonvegetation. The experimental results using the proposed methodology showed better performance than two of the most used color index methods.


  • Statistical unit root test for edge detection in ultrasound images of vessels and cysts

    by Mehdi Moradi, S. Sara Mahdavi, Julian Guerrero, Robert Rohling, Septimiu E. Salcudean

    A new approach is proposed for edge detection in ultrasound. The technique examines the image intensity profile for unit roots based on the Dickey–Fuller statistical test of stationarity. The existence of the unit root is a sign of nonstationarity and a possible edge. A simple algorithm to build a segmentation method based on this edge detection approach is also proposed, which is capable of delineating the perimeter of hollow structures such as blood vessels and cysts. In this approach, the radial edge profiles originating from the center of the object of interest are scanned for the change from stationary to nonstationary status. The algorithm treats the radial intensity profiles as a time series and uses the Dickey–Fuller statistical test along the radii to find the location at which the profile becomes nonstationary. A priori criteria for edge continuity, shape, and size of the object of interest are applied to enhance the stability of the algorithm. The accuracy is demonstrated on simulated ultrasound. Further, the method is examined on two different image sets of blood vessels and validated based on contours marked by experts. The worst case distance from expert contours is 1.8±0.3  mm. The average area difference between the expert and the extracted contours is ∼6% and ∼4% of the vessel area in the two datasets. The proposed segmentation method is also compared to segmentation using active contours on ultrasound images of breast and ovarian cysts and shown to be accurate and stable.


  • Preliminary results of an ultrasound segmentation method based on statistical unit-root test of B-scan radial intensity profiles

    by Mehdi Moradi, Julian Guerrero, Robert Rohling, Septimiu E. Salcudean

    Delineation of the perimeter of hollow structures, such as veins and arteries, from ultrasound images is an important step in US-based medical interventions. A simple and efficient approach is proposed for edge detection in ultrasound images. The technique examines the radial edge profiles for ¿unit root¿ based on the Dickey-Fuller test. The existence of the unit root is a sign of a trend, and hence non-stationarity, in the statistics of the edge profile. The method is applied to simulated data and clinical images of human arteries and veins. The outcomes are validated based on the average of the Hausdorff distance between the automatically derived vessel contours and vessel contours marked by five experts. The proposed edge detection method provides accurate segmentations (average Hausdorff distance from expert segmentation of 1.5 mm in vessel images and 0.4 mm in simulated data).

  • Real-Time Vessel Segmentation and Tracking for Ultrasound Imaging Applications

    by Julian Guerrero, Septimiu E. Salcudean, James A. McEwen, Bassam A. Masri, Savvakis Nicolaou

    A method for vessel segmentation and tracking in ultrasound images using Kalman filters is presented. A modified Star-Kalman algorithm is used to determine vessel contours and ellipse parameters using an extended Kalman filter with an elliptical model. The parameters can be used to easily calculate the transverse vessel area which is of clinical use. A temporal Kalman filter is used for tracking the vessel center over several frames, using location measurements from a handheld sensorized ultrasound probe. The segmentation and tracking have been implemented in real-time and validated using simulated ultrasound data with known features and real data, for which expert segmentation was performed. Results indicate that mean errors between segmented contours and expert tracings are on the order of 1%-2% of the maximum feature dimension, and that the transverse cross-sectional vessel area as computed from estimated ellipse parameters a, b as determined by our algorithm is within 10% of that determined by experts. The location of the vessel center was tracked accurately for a range of speeds from 1.4 to 11.2 mm/s.


  • Deep venous thrombosis screening system using numerical measures

    by J. Guerrero, S.E. Salcudean, J.A. McEwen, B.A. Masri, S. Nicolaou

    An experimental system and interface that indicate the likelihood of deep venous thrombosis using objective numerical measures was developed, based on the conventional compression ultrasound examination. A sensorized ultrasound probe is used to acquire force, location and image data to assess a vessel segment for compression. Ultrasound image data is segmented using a modified Star-Kalman algorithm. A user interface displays the results using a 3-D representation. A tissue phantom was developed for testing and validation. Initial results with this phantom and healthy volunteers are presented.


  • Measurement-Based Deep Venous Thrombosis Screening System

    by Julian Guerrero, S. E. Salcudean, James A. McEwen, Bassam A. Masri, Savvas Nicolaou