CHClemens Honeder

Clemens Honeder

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Clemens Honeder has a total of 72 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The Bonebridge BCI 602 Safety and Performance 1 Year Post-Implantation in Adults and Children: A Multicentric Post-Market Study

    by Stefan K. Plontke, Thomas Lenarz, Joseph Toner, Thomas Keintzel, Georg Sprinzl, Wolf-Dieter Baumgartner, Assen Koitschev, Joachim Schmutzhard, Gerrit Götze, Torsten Rahne, et al.

    Objective: To confirm the long-term safety and performance of the Bonebridge BCI 602 in patients suffering from conductive or mixed hearing loss (CMHL) or single-sided deafness (SSD) over a 12-month period post-implantation. Study design: Multicentric, multinational, ambidirectional, observational Post-Market Clinical Follow-Up (PMCF) study. Setting: Eight tertiary referral hospitals. Participants: Fifty-two participants in 3 categories: adults CMHL (N=24), children CMHL (N=17), and SSD (N=11; 9 adults and 2 children). Intervention: Participants were implanted with the Bonebridge BCI 602 device. Main outcome measure(s): Outcome measures focused on sound field thresholds (SF), word recognition scores (WRS), speech reception thresholds (SRT) in both quiet and noise, adverse events, and subjective satisfaction (SSQ and AQoL questionnaires) at initial activation and at 3-month and 12-month post-implantation. Results: Safety was established by stable bone conduction (BC) thresholds and a low adverse event rate with no unanticipated events. Safety was underlined by clinically relevant improvements in the health-related assessment of Quality of Life (AQoL) questionnaire of mean+0.1 (adults and children CMHL) and +0.07 (SSD). Hearing significantly improved in sound field thresholds with mean functional gains of 24.05±8.68 dB (adults CMHL), 21.34±25.43 dB (children CMHL), and 32.89±25.87 dB (SSD). Mean word recognition scores improved by 65.83±28.62 percent points (PP) for adult CMHL and 65.77±27.53 PP for children CMHL and speech reception thresholds (SRT) in quiet by 15.4±9.34 dB and 19.96±14.66 dB, respectively. SRT in noise improved by −5.57±4.23 dB (adults; S 0° N 0° ), −5.12±5.08 dB (children, S 0° N 0° ), and −3.05±3.06 dB (SSD, S SSD N NH ). Subjective hearing ability tested with the Speech, Spatial, and Qualities (SSQ) of Hearing questionnaire improved and was clinically relevant for the adult (+2.23) and children (+1.51) CMHL groups. Conclusions: The Bonebridge BCI 602 demonstrates significant enhancements in hearing and speech understanding 12 months postoperatively, showing high user satisfaction and safety.


  • Open Access

    A Novel Preparation Technique for Human Nasal Respiratory Mucosa to Disclose Its Glycosylation Pattern for Bioadhesive Drug Delivery

    by Julia Clara Gausterer, Michael Schlager, Navid Ahmadi, Michael Nieratschker, Valerie Dahm, Michael Wirth, Christoph Arnoldner, Clemens Honeder, Franz Gabor

    To shed some light on glycotargeting as a potential strategy for nasal drug delivery, a reliable preparation method for human nasal mucosa samples and a tool to investigate the carbohydrate building blocks of the glycocalyx of the respiratory epithelium are required. Applying a simple experimental setup in a 96-well plate format together with a panel of six fluorescein-labeled lectins with different carbohydrate specificities allowed for the detection and quantification of accessible carbohydrates in the mucosa. As confirmed by binding experiments at 4 °C, both quantitatively by fluorimetry and qualitatively by microscopy, the binding of wheat germ agglutinin exceeded that of the others by 150% on average, indicating a high content of N-acetyl-D-glucosamine and sialic acid. Providing energy by raising the temperature to 37 °C revealed uptake of the carbohydrate-bound lectin into the cell. Moreover, repeated washing steps during the assay gave a slight hint as to the influence of mucus renewal on bioadhesive drug delivery. All in all, the experimental setup reported here for the first time is not only a suitable approach to estimating the basics and potential of nasal lectin-mediated drug delivery but also meets the needs for answering a broad variety of scientific questions involving the use of ex vivo tissue samples.


  • Open Access

    Multicentric study on surgical information and early safety and performance results with the Bonebridge BCI 602: an active transcutaneous bone conduction hearing implant

    by Georg Sprinzl, Joseph Toner, Assen Koitschev, Nadine Berger, Thomas Keintzel, Thomas Rasse, Wolf-Dieter Baumgartner, Clemens Honeder, Astrid Magele, Stefan Plontke, et al.

    Aim: This European multicentric study aimed to prove safety and performance of the Bonebridge BCI 602 in children and adults suffering from either conductive hearing loss (CHL), mixed hearing loss (MHL), or single-sided sensorineural deafness (SSD). Methods: 33 patients (13 adults and 10 children with either CHL or MHL and 10 patients with SSD) in three study groups were included. Patients were their own controls (single-subject repeated measures), comparing the unaided or pre-operative to the 3-month post-operative outcomes. Performance was evaluated by sound field thresholds (SF), word recognition scores (WRS) and/or speech reception thresholds in quiet (SRT) and in noise (SNR). Safety was demonstrated with a device-specific surgical questionnaire, adverse event reporting and stable pure-tone measurements. Results: The Bonebridge BCI 602 significantly improved SF thresholds (+ 25.5 dB CHL/MHL/SSD), speech intelligibility in WRS (+ 68.0% CHL/MHL) and SRT in quiet (− 16.5 dB C/MHL) and in noise (− 3.51 dB SNR SSD). Air conduction (AC) and bone conduction (BC) thresholds remained stable over time. All adverse events were resolved, with none unanticipated. Mean audio processor wearing times in hours [h] per day for the CHL/MHL group were ~ 13 h for adults, ~ 11 h for paediatrics and ~ 6 h for the SSD group. The average surgical length was 57 min for the CHL/MHL group and 42 min for the SSD group. The versatility of the BCI 602 (reduced drilling depth and ability to bend the transition for optimal placement) allows for treatment of normal, pre-operated and malformed anatomies. All audiological endpoints were reached. Conclusions: The Bonebridge BCI 602 significantly improved hearing thresholds and speech understanding. Since implant placement follows the patient’s anatomy instead of the shape of the device and the duration of surgery is shorter than with its predecessor, implantation is easier with the BCI 602. Performance and safety were proven for adults and children as well as for the CHL/MHL and SSD indications 3 months post-operatively.


  • Intratympanic application of poloxamer 407 hydrogels results in sustained N-acetylcysteine delivery to the inner ear

    by Julia Clara Gausterer, Nodir Saidov, Navid Ahmadi, Chengjing Zhu, Michael Wirth, Gottfried Reznicek, Christoph Arnoldner, Franz Gabor, Clemens Honeder


  • Long-term effects and potential limits of intratympanic dexamethasone-loaded hydrogels combined with dexamethasone-eluting cochlear electrodes in a low-insertion trauma Guinea pig model

    by Navid Ahmadi, Julia Clara Gausterer, Clemens Honeder, Marlene Mötz, Hanna Schöpper, Chengjing Zhu, Nodir Saidov, Franz Gabor, Christoph Arnoldner


  • Sustained-Release Triamcinolone Acetonide Hydrogels Reduce Hearing Threshold Shifts in a Model for Cochlear Implantation with Hearing Preservation

    by Clemens Honeder, Chengjing Zhu, Julia Clara Gausterer, Hanna Schöpper, Navid Ahmadi, Nodir Saidov, Michael Nieratschker, Franz Gabor, Christoph Arnoldner

    Introduction: In recent years, the preservation of residual hearing has become a major factor in patients undergoing cochlear implantation (CI). In studies attempting to pharmaceutically improve hearing preservation rates, glucocorticoids (GCs) applied perioperatively in many institutions have emerged as a promising treatment regimen. Although dexamethasone is most commonly used and has been applied successfully by various research groups, recently pharmacological properties have been reported to be relatively unsuitable for topical delivery to the inner ear. Consequently other glucocorticoids merit further evaluation. The aim of this study was therefore to evaluate the otoprotective effects of the topical application of a sustained-release triamcinolone acetonide (TAAC) hydrogel in CI with hearing preservation. Methods: Normal-hearing pigmented guinea pigs were randomized into a group receiving a single dose of a 6% TAAC poloxamer 407 hydrogel, a group receiving a 30% TAAC hydrogel and a control group. All hydrogel applications were performed 1 day prior to CI. After a cochleostomy was drilled, a specifically designed silicone electrode was inserted into the scala tympani for 5 mm. Frequency-specific compound action potentials of the auditory nerve (0.5–32 kHz) were measured pre- and directly postoperatively as well as on days 3, 7, 14, 21, and 28. Finally, temporal bones were harvested for histological evaluation. Results: Application of the TAAC hydrogels resulted in significantly reduced hearing threshold shifts in low, middle and high frequencies and improved spiral ganglion cell survival in the second turn of the cochlea. Outer hair cell numbers in the basal and second turn of the cochlea were slightly reduced after TAAC application. Conclusion: In summary, we were able to demonstrate functional benefits of a single preoperative application of a TAAC hydrogel in a guinea pig model for CI, which persisted until the end of the observational period, that is, 28 days after surgery.


  • Single Sided Deaf Cochlear Implant Users in the Difficult Listening Situation: Speech Perception and Subjective Benefit

    by David A. Prejban, Jafar-Sasan Hamzavi, Christoph Arnoldner, Rudolfs Liepins, Clemens Honeder, Alexandra Kaider, Wolfgang Gstöttner, Wolf-Dieter Baumgartner, Dominik Riss

    Objectives: Patients with single-sided deafness (SSD) have great difficulties in listening situations which rely on binaural auditory processing. The purpose of this study was to examine to which extent a cochlear implant (CI) can improve speech perception outcomes in various noisy listening environments. Additionally, the ability to use interaural level differences for sound localization and subjective benefit with the CI were assessed. Methods: Ten single-sided deaf patients with CI were tested in different loudspeaker configurations with and without the CI. A multi-source noise field (MSNF) with uncorrelated noise from four different directions was used in addition to a setup with the signal from the CI side and noise from the normal-hearing side (SCINNH, azimuth of ±45 degrees). Ten normal-hearing subjects were used as a control for the setup. Speech understanding was measured by an adaptive sentence test (Oldenburg Sentence Test, OLSA) in stationary speech shaped noise and temporally modulated noise to assess the benefit in each listening situation. Sensitivity to interaural level differences was measured in a lateralization experiment. Furthermore, patients completed the Bern Benefit in Single-Sided Deafness (BBSS) questionnaire to assess subjective benefit with the CI. Results: An overall average benefit in speech reception threshold (SRT) of 1.6 dB (±0.6 dB standard error of the mean [SEM]) was observed in the binaural listening condition (with CI) in all conditions. In the MSNF setup thresholds improved by 0.4 dB (±0.5 dB SEM) and in the SCINNH configuration by 2.7 dB (±0.7 dB SEM). The choice of masking noise effect also had a significant effect on the SRT outcome. The lateralization performance of the SSD users was on a par with the normal hearing group. BBSS scores reflect the overall benefit with the CI apparent in the speech test results. Conclusion: Patients with single-sided deafness do benefit from a CI in difficult listening environments and are able to localize sound based on interaural level differences. Considering these outcomes, cochlear implantation represents a promising treatment option for patients with single-sided deafness.


  • Evaluation of Sustained-Release Steroid Hydrogels in a Guinea Pig Model for Noise-Induced Hearing Loss

    by Chengjing Zhu, Julia Clara Gausterer, Hanna Schöpper, Michael Nieratschker, Nodir Saidov, Navid Ahmadi, Clemens Honeder, Franz Gabor, Christoph Arnoldner

    The otoprotective effects of thermoreversible poloxamer 407 hydrogels containing dexamethasone or triamcinolone acetonide were evaluated in an animal model of noise-induced hearing loss. Seven days after noise exposure, hearing threshold shifts at 16 kHz were significantly reduced in the 6% dexamethasone group (p < 0.05). Even though no significant differences in hair cell counts were found, histological analysis revealed a significantly higher spiral ganglion cell density in the first turn of the cochlea in this group (p < 0.05). No otoprotective effects were observed after the application of the triamcinolone acetonide hydrogels. As the findings of this study indicate potential otoprotective effects of sustained topical dexamethasone delivery in the setting of noise-induced hearing loss, this strategy merits further evaluation.


  • Open Access

    Cochlear Implantation in the Guinea Pig

    by Clemens Honeder, Navid Ahmadi, Anne-Margarethe Kramer, Chengjing Zhu, Nodir Saidov, Christoph Arnoldner

    Cochlear implants are highly efficient devices that can restore hearing in subjects with profound hearing loss. Due to improved speech perception outcomes, candidacy criteria have been expanded over the last few decades. This includes patients with substantial residual hearing that benefit from electrical and acoustical stimulation of the same ear, which makes hearing preservation during cochlear implantation an important issue. Electrode impedances and the related issue of energy consumption is another major research field, as progress in this area could pave the way for fully implantable auditory prostheses. To address these issues in a systematic way, adequate animal models are essential. Therefore, the goal of this protocol is to provide an animal model of cochlear implantation, which can be used to address various research questions. Due to its large tympanic bulla, which allows easy surgical access to the inner ear, as well as its hearing range which is relatively similar to the hearing range of humans, the guinea pig is a commonly used species in auditory research. Cochlear implantation in the guinea pig is performed via a retroauricular approach. Through the bullostomy a cochleostomy is drilled and the cochlear implant electrode is inserted into the scala tympani. This electrode can then be used for electrical stimulation, determination of electrode impedances and the measurement of compound action potentials of the auditory nerve. In addition to these applications, cochlear implant electrodes can also be used as drug delivery devices, if a topical delivery of pharmaceutical agents to the cells or fluids of the inner ear is intended.


  • Open Access

    Cochlear Implantation in the Guinea Pig

    by Clemens Honeder, Navid Ahmadi, Anne-Margarethe Kramer, Chengjing Zhu, Nodir Saidov, Christoph Arnoldner

    Cochlear implants are highly efficient devices that can restore hearing in subjects with profound hearing loss. Due to improved speech perception outcomes, candidacy criteria have been expanded over the last few decades. This includes patients with substantial residual hearing that benefit from electrical and acoustical stimulation of the same ear, which makes hearing preservation during cochlear implantation an important issue. Electrode impedances and the related issue of energy consumption is another major research field, as progress in this area could pave the way for fully implantable auditory prostheses. To address these issues in a systematic way, adequate animal models are essential. Therefore, the goal of this protocol is to provide an animal model of cochlear implantation, which can be used to address various research questions. Due to its large tympanic bulla, which allows easy surgical access to the inner ear, as well as its hearing range which is relatively similar to the hearing range of humans, the guinea pig is a commonly used species in auditory research. Cochlear implantation in the guinea pig is performed via a retroauricular approach. Through the bullostomy a cochleostomy is drilled and the cochlear implant electrode is inserted into the scala tympani. This electrode can then be used for electrical stimulation, determination of electrode impedances and the measurement of compound action potentials of the auditory nerve. In addition to these applications, cochlear implant electrodes can also be used as drug delivery devices, if a topical delivery of pharmaceutical agents to the cells or fluids of the inner ear is intended.