Chengchao Lu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chengchao Lu has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Yang Yu
Department of Control Science and Engineering, Tongji University, Shanghai, China
2 shared publicationsZhongjie Wang
Department of Control Science and Engineering, Tongji University, Shanghai, China
2 shared publications- Zhongjie Wang
College of Electronics and Information Engineering, Tongji University, Shanghai, China
2 shared publications Ming Ma
Department of Control Science and Engineering, Tongji University, Shanghai, China
1 shared publicationRunjie Shen
Department of Control Science and Engineering, Tongji University, Shanghai, China
1 shared publication- Yang Yu
College of Information Engineering, Zhejiang University of Water Resources and Electric Power, Hangzhou, China
1 shared publication
Latest Publications
- Open Access
- 20 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 6, 54417-54426
An Optimal PMU Placement With Reliable Zero Injection Observation
Zero injection (ZI) is an inherent characteristic of a power grid. The effect of ZI (ZI effect) is usually utilized as an auxiliary measurement termed ZI observation for simplification. We discover that the ZI observation can transmit. The reliability of ZI observation becomes weaker, as ZI observation transmits “deeper.” In this paper, a unified phasor measurement unit (PMU) placement model is proposed with considering the reliability of ZI observation. To improve the reliability of ZI observation, the depth of ZI observation is limited, and the ZI utilization rate is minimized. The optimality problem which considers reliable ZI observation is studied, which has not been discussed before. Five working conditions, i.e., base case, $N-1$ PMU outage, $N-1$ line outage, $N-1$ PMU outage, or $N-1$ line outage, and the PMU measurement channel limitation are studied. The proposed method is tested on six IEEE test systems, i.e., IEEE 14-, 30-, 39-, 57-, 118-, and 300-bus systems, the Polish 2383-bus test system, and a practical power system in China. Results indicate that the proposed method not only reduces the number of PMUs by employing ZI effect but also ensures the reliability of ZI observation while making full observation of the power system.
- 20 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 6, 54417-54426
Open AccessAn Optimal PMU Placement With Reliable Zero Injection Observation
Zero injection (ZI) is an inherent characteristic of a power grid. The effect of ZI (ZI effect) is usually utilized as an auxiliary measurement termed ZI observation for simplification. We discover that the ZI observation can transmit. The reliability of ZI observation becomes weaker, as ZI observation transmits “deeper.” In this paper, a unified phasor measurement unit (PMU) placement model is proposed with considering the reliability of ZI observation. To improve the reliability of ZI observation, the depth of ZI observation is limited, and the ZI utilization rate is minimized. The optimality problem which considers reliable ZI observation is studied, which has not been discussed before. Five working conditions, i.e., base case, $N-1$ PMU outage, $N-1$ line outage, $N-1$ PMU outage, or $N-1$ line outage, and the PMU measurement channel limitation are studied. The proposed method is tested on six IEEE test systems, i.e., IEEE 14-, 30-, 39-, 57-, 118-, and 300-bus systems, the Polish 2383-bus test system, and a practical power system in China. Results indicate that the proposed method not only reduces the number of PMUs by employing ZI effect but also ensures the reliability of ZI observation while making full observation of the power system.
- 7 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 68 (1) , 87-94
A Joint Filter Approach for Reliable Power System State Estimation
Accurate power system state estimation facilitates power system control, optimization, and security analysis. In this paper, a joint filter approach is proposed to estimate both the static states (voltage magnitude and phase angle of bus) and the dynamic states (rotor angle, rotor speed, and transient voltages of generator) utilizing the measurements of phasor measurement unit. First, due to the complexity and dynamics of power system, the power system model is usually not known accurately. The uncertainties include both model uncertainty and noise statistics uncertainty. Therefore, H∞ filter is applied to reliable estimation of the static states. As a link between the static state estimation and the dynamic state estimation, the estimated static states are fed to dynamic state estimation. Next, to deal with the nonlinearity of synchronous generator model, an extended Kalman particle filter is employed to accurately estimate the dynamic states. The numerical tests on IEEE 30-bus system show that the proposed method is into both the static state estimation and the dynamic state estimation.
- 7 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 68 (1) , 87-94
A Joint Filter Approach for Reliable Power System State Estimation
Accurate power system state estimation facilitates power system control, optimization, and security analysis. In this paper, a joint filter approach is proposed to estimate both the static states (voltage magnitude and phase angle of bus) and the dynamic states (rotor angle, rotor speed, and transient voltages of generator) utilizing the measurements of phasor measurement unit. First, due to the complexity and dynamics of power system, the power system model is usually not known accurately. The uncertainties include both model uncertainty and noise statistics uncertainty. Therefore, H∞ filter is applied to reliable estimation of the static states. As a link between the static state estimation and the dynamic state estimation, the estimated static states are fed to dynamic state estimation. Next, to deal with the nonlinearity of synchronous generator model, an extended Kalman particle filter is employed to accurately estimate the dynamic states. The numerical tests on IEEE 30-bus system show that the proposed method is into both the static state estimation and the dynamic state estimation.
- Open Access
- 18 April 2018
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 12 (10) , 2231-2237
Optimal PMU placement for pessimistic dynamic vulnerability assessment
This study proposes a novel optimal phasor measurement unit (PMU) placement method for dynamic vulnerability assessment with minimum number of PMUs. PMU measurements should reflect the change of power system status as earlier as possible when a contingency occurs. Therefore, those buses which are sensitive to the change of power system status have to be equipped with PMUs to monitor the fragile areas of power systems. First, a large power system is partitioned into several coherent clusters. Next, a probabilistic vulnerability index defined as the objective function and a binary quadratic programming model are proposed for this purpose. Finally, the proposed method is tested on IEEE 9‐, 39‐, and 145‐bus systems. Results show that this method results in a PMU configuration with minimum number of devices and high vulnerability index. Such a PMU placement is able to estimate the vulnerability of power systems.
- 18 April 2018
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 12 (10) , 2231-2237
Open AccessOptimal PMU placement for pessimistic dynamic vulnerability assessment
This study proposes a novel optimal phasor measurement unit (PMU) placement method for dynamic vulnerability assessment with minimum number of PMUs. PMU measurements should reflect the change of power system status as earlier as possible when a contingency occurs. Therefore, those buses which are sensitive to the change of power system status have to be equipped with PMUs to monitor the fragile areas of power systems. First, a large power system is partitioned into several coherent clusters. Next, a probabilistic vulnerability index defined as the objective function and a binary quadratic programming model are proposed for this purpose. Finally, the proposed method is tested on IEEE 9‐, 39‐, and 145‐bus systems. Results show that this method results in a PMU configuration with minimum number of devices and high vulnerability index. Such a PMU placement is able to estimate the vulnerability of power systems.
- 23 January 2018
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modeling, Simulation, and Scientific Computing
- Vol. 09 (01)
A cluster-autonomous partitioning algorithm in electrical power grid using Monte Carlo simulation
Power grid partitioning decomposes a large power grid into several clusters. Most of the existing partitioning methods suffer from a limitation that the buses within a cluster are severely topologically disconnected after partitioning in some cases. As a result, a cluster will inevitably be assigned to two or more power grid corporations. This assignment obstructs inner-cluster monitoring and control applications of the transmission system. To overcome the limitation, this paper proposes a multi-index power grid partitioning approach using Monte Carlo simulation guaranteeing cluster connectivity to ensure the cluster autonomy. A line-based binary coding technique is developed to ensure the cluster connectivity. Three partitioning indices are considered: the coherency, the cluster connectivity, and the number of clusters. Finally, the proposed partitioning method is applied to IEEE 9-bus system, IEEE 39-bus system and IEEE 145-bus system and compared with Fuzzy C-medoid (FCMdd) algorithm.
- 23 January 2018
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modeling, Simulation, and Scientific Computing
- Vol. 09 (01)
A cluster-autonomous partitioning algorithm in electrical power grid using Monte Carlo simulation
Power grid partitioning decomposes a large power grid into several clusters. Most of the existing partitioning methods suffer from a limitation that the buses within a cluster are severely topologically disconnected after partitioning in some cases. As a result, a cluster will inevitably be assigned to two or more power grid corporations. This assignment obstructs inner-cluster monitoring and control applications of the transmission system. To overcome the limitation, this paper proposes a multi-index power grid partitioning approach using Monte Carlo simulation guaranteeing cluster connectivity to ensure the cluster autonomy. A line-based binary coding technique is developed to ensure the cluster connectivity. Three partitioning indices are considered: the coherency, the cluster connectivity, and the number of clusters. Finally, the proposed partitioning method is applied to IEEE 9-bus system, IEEE 39-bus system and IEEE 145-bus system and compared with Fuzzy C-medoid (FCMdd) algorithm.